Delfield N225, N227, N225L, N227L, 203 Service Manual

...
200 & 300 SERIES
CA
UTION
Delfield
®
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
Drop In and Undercounter Products
IMPORTANT INFORMATION
READ BEFORE USE
March 2009
200 and 300 Series Service and Installation Manual
Delfield
®
Contents
Serial Number Information ........................................................ 2
Receiving And Inspecting Equipment ........................................ 2
Specifications ............................................................................. 2
Installation ...............................................................................3-4
Operation ....................................................................................5
Maintenance ............................................................................... 5
Serial Number Information
Models Serial Tag Location
N225, N227 On the compressor stand next to the temperature control
203, 204, 204P, 248, 250, 305 On the bottom of the ice chests
240 On the back
242 On the bottom of the sink
307 Underneath the top
Replacement Parts ..................................................................6-8
Wiring Diagram ..........................................................................8
Standard Labor Guidelines ........................................................9
Standard Warranty ..............................................................10-11
Always have the serial number of your unit available when calling for parts or service.
©2009 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. “Delfield” is a registered trademarks of The Delfield Company.
Receiving And Inspecting The Equipment
Even though most equipment is shipped packaged, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment
4. Request an inspection by the shipping company of the
5. Visually inspect the refrigeration package. Be sure lines
6. Freight carriers can supply the necessary damage forms
7. Retain all crating material until an inspection has been
notify the carrier. Notification should be made verbally as well as in written form.
damaged equipment. This should be done within 10 days from receipt of the equipment.
are secure and base is still intact.
upon request.
made or waived.
Specifications
MODEL L D H SHIP
DROP-IN FREEZERS
N225
N227
DROP-IN REEZERS WITH LEXAN® LID
N225L
N227L
DROP-IN WATER STATIONS AND ICE STORAGE
ice chest 20.25”
203
water and ice
204
station water and ice
204P
station ice chest with
240
cover water and ice
248
station ice chest with
305
cover glass filler 12”
307
UNDERCOUNTER SINKS, WATER STATIONS AND ICE STORAGE
UC sink & faucet 18”
242
UC sink, ice chest
250
and water station
16.56” (42.1cm)
30” (76.2cm)
16.56” (42.1cm)
30” (76.2cm)
(51.4cm) 24”
(61.0cm) 24”
(61.0cm) 21”
(53.3cm) 31”
(78.7cm)
21.25” (54.0cm)
(30.5cm)
(45.7cm) 46”
(116.8cm)
27.87” (70.8cm)
27.87” (70.8cm)
27.87” (70.8cm)
27.87” (70.8cm)
20.25” (51.4cm)
21” (53.3cm)
21” (53.3cm)
17.5” (44.5cm)
15” (38.1cm)
15.25” (38.7cm)
12” (30.5cm)
13.5” (34.3cm)
14.12” (35.9cm)
26.75” (67.9cm)
26.75” (67.9cm)
26.75” (67.9cm)
26.75” (67.9cm)
23.25” (59.1cm)
23.5” (59.1cm)
27” (68.6cm)
17” (43.2cm)
22.5” (57.2cm)
13” (33.0cm)
9.5” (24.1cm)
12.75” (32.4cm)
22.75” (57.8cm)
WEIGHT
115lbs (52kg)
191lbs (87kg)
115lbs (52kg)
191lbs (87kg)
52lbs (24kg)
47.5lbs (22kg)
47.5lbs (22kg)
36lbs (16kg)
28lbs (13kg)
18lbs (8kg)
7lbs (3kg)
20lbs (9kg)
81lbs (37kg)
CUTOUT SIZE CABINET
25.75” x 14.62” (65.4cm x 37.1cm)
25.75” x 28.00” (65.4cm x 71.1cm)
25.75” x 14.62” (65.4cm x 37.1cm)
25.75” x 28.00” (65.4cm x 71.1cm)
19.25” x 19.25” (48.9cm x 48.9cm)
21” x 17.75” (53.3cm x 45.1cm)
21” x 17.75” (53.3cm x 45.1cm)
75lbs
28” x 12.5” (71.1cm x 31.8cm)
12.5” x 17.75” (31.8cm x 45.1cm)
9.00” x 9.00” (23cm x 23cm)
17” x 12.5” (43.2cm x 31.8cm)
45” x 13” (114.3cm x 33.0cm)
CAPACITY
6 gal. 1/5 5.3 115 5-15P 292 411 20/20°/-23°
12 gal. 1/5 5.3 115 5-15P 473 532 28/19°/-22
6 gal. 1/5 5.3 115 5-15P 292 411 20/20°/-23°
12 gal. 1/5 5.3 115 5-15P 473 532 28/19°/-22
90lbs (41kg)
45lbs (20kg)
45lbs (20kg)
(34kg) 45lbs
(20kg) 45lbs
(20kg) — N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
45lbs (20kg)
H.P. AMP VOLT NEMA
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A
PLUG
DESIGN LOAD BTU
SYSTEM CAP. BTU
EVAP BTU/ TD/TEMP
2
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
200 and 300 Series Service and Installation Manual
Delfield
®
TYPICAL
COUNTER
CABINET
LOUVER
13.00" x 25.00"
33.0cm x 63.5cm
LOUVER CUTOUT SIZE
12.00" x 23.50"
30.5cm x 59.7cm (typical installation)
NOTE: A second cutout (without louver) must also be made to allow proper air flow.
N225 N225L N227 or N227L DROP-IN
25.75"
65.4cm
28.0"
71.1cm
CUTOUT
.75"/1.9cm radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
25.75"
65.4cm
14.62"
37.1cm
CUTOUT
.75"/1.9cm radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
Installation - Models N225, N225L, N227 And N227L
Location
Units in this manual are intended for indoor use only. The refrigeration system has been factory tested and should require no further adjustment during installation.
For the most efficient refrigeration, be sure to provide good air circulation inside and outside the unit.
Outside Cabinet: Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens.
Counter Cutouts
For installation provide a cutout in the counter as shown (see illustration 1 or 2). The counter must be sturdy enough to hold the combined weight up to 300 pounds of the drop-in and the product stored inside.
The louver provided must be installed in front of the condensing unit’s finned coil (see illustration 3). A second cutout must be made at the rear or end of the equipment to allow air flow through the unit. No louver is provided for the second cutout. Any restriction to the proper air flow, total or partial, will void the compressor warranty.
Illustration 1. Model N225 & N225L cutout dimensions
Illustration 2. Model N227 & N227L cutout dimensions
Illustration 3. N225 N225L N227 & N227L louver installation
Electrical Connection
Refer to the amperage data on page 2, the serial tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord.
If the unit does not operate after it is plugged in, check the thermostat to see if it was inadvertently turned OFF during installation.
The unit must be disconnected from the power source whenever performing service or maintenance functions.
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
3
200 and 300 Series Service and Installation Manual
Delfield
®
22.00” (55.9cm)
204/204P Stud Location
19.25” (48.9cm)
204/204P Stud Location
29.50” (74.9cm)
248 Stud Location
13.50” (34.3cm)
13.25” (33.7cm)
305 Stud Location
19.375” (49.2cm)
305 Stud Location
10.12” (25.7cm)
307 Stud Location
10.12” (25.7cm) 307 Stud Location
Installation - Models 203, 204, 204P, 240, 242, 248, 250, 305 And 307
Location
Units in this manual are intended for indoor use only.
Avoid hot corners and locations near stoves and ovens.
Counter Cutouts
For installation, provide a cutout in the counter sized according to the chart below. The counter must be sturdy enough to hold the combined weight up to 300 pounds of the drop-in and the product stored inside.
Drain
Provided 1” (2.5cm) drain, nut and washer must be field installed to an appropriate container or floor drain following local code requirements. Sinks come standard with 1-1/2” basket strainer assemblies.
Water Connection
All 1/2” (1.3cm) IPS water inlets must be field connected following local code requirements.
Model Cutout Size Mounting
ice chest 19.25” x 19.25”
203
water and ice
204
station water and ice
204P
station ice chest with cover N/A N/A N/A (1) 1”
240
UC sink & faucet 17” x 12.5”
242
water and ice
248
station UC sink, ice chest
250
and water station ice chest with cover 12.5” x 17.75”
305
glass filler 9.00” x 9.00”
307
(48.9cm x 48.9cm) 21” x 17.75”
(53.3cm x 45.1cm) 21” x 17.75”
(53.3cm x 45.1cm)
(43.2cm x 31.8cm) 28” x 12.5”
(71.1cm x 31.8cm) 45” x 13”
(114.3cm x 33.0cm)
(31.8cm x 45.1cm)
(23cm x 23cm)
Studs
N/A N/A (1) 1”
4 1 (2) 1”
4 1 (2) 1”
N/A 2 (1) 1-1/2”
4 1 (2) 1”
N/A 3 (2) 1”
4 N/A (1) 1”
4 1 (1) 1”
1/2” IPS Water Hookup
Drain
(1) 1-1/2”
Mounting Studs
Equipment with mounting studs are pictured below. Mark the stud locations according to the measurements or place the equipment in the cutout to mark the stud locations. Drill 0.37” (1.0cm) diameter holes through the counter for the studs.
4
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com