Delfield DCCS-SD, DCCS-SDW, DCCS-SDWL, DCCS-SDWR, DCCS-DD Operation Manual

...
Concepts Serving Systems
Use & Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
Effective June 2010
Concepts Use & Care Manual
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing
Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage,
Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The
Vicinity Of This Or Any Other Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do
Not Operate This Equipment.
WARNING Do Not Clean With Water Jet.
CAUTION Observe the following:
Minimum clearances must be maintained from all walls and combustible
• materials.
Keep the equipment area free and clear of combustible material.
Adequate clearance for air openings.
Operate equipment only on the type of electricity indicated on the
• specification plate.
Retain this manual for future reference.
2
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Concepts Use & Care Manual
Contents Serial Number Information
Receiving & Inspecting The Equipment ....................................4
Specifications ..........................................................................5-7
If your unit is heated, the serial tag is located above the louvered panel near the on/off switch.
Installation
Heated Units ...........................................................................8
Refrigerated Units ...................................................................8
Operation
Heated Units ............................................................................9
Mechanically Cooled Serving Counters ..................................9
LiquiTec Units .......................................................................10
Frost Top Serving Counters ..................................................10
Maintenance .............................................................................11
Wiring Diagrams
Heated Serving Counter ........................................................12
Mechanically Cooled Serving Counter ..................................13
LiquiTec Units .......................................................................13
Refrigerated units have the serial tag located in the compressor area near the on/off switch.
Understorage units often have the serial tag located on the left inside the storage area.
All purpose counters, utility equipment or delivery carts do not require serial numbers but a model tag is placed at the top of the pylon on the back of the unit.
Always have the serial number of your unit available when calling for parts or service.
This manual covers standard units only. If you have a custom unit, consult the customer service department at the number listed below.
Frost Top Serving Counters ..................................................13
Standard Labor Guidelines ......................................................14
Replacement Parts List ............................................................15
Standard Warranty ..............................................................16-17
Notes ...................................................................................18-19
©2010 The Delfield Company. All rights reserved. Reproduction without writ­ten permission is prohibited.
“Delfield” is a registered trademarks of The Delfield Company.
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
3
Concepts Use & Care Manual
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
Visually inspect the exterior of the package and skid or
1. container. Any damage should be noted and reported to the delivering carrier immediately.
If damaged, open and inspect the contents with the
2. carrier.
In the event that the exterior is not damaged, yet upon
3. opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
Request an inspection by the shipping company of the
4. damaged equipment. This should be done within 10 days from receipt of the equipment.
Check the lower portion of the unit to be sure legs or
5. casters are not bent.
Also open the compressor compartment housing and
6. visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
Freight carriers can supply the necessary damage forms
7. upon request.
Retain all crating material until an inspection has been
8. made or waived.
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.
The units with LiquiTec technology cold pans contain a non-toxic eutectic fluid within a sealed inner liner. This fluid may leak if the tank is punctured so care must be taken when uncrating and setting in place. The eutectic fluid is non-toxic and may be flushed down a disposal drain. If the LiquiTec unit cold pans leak, immediately call the Delfield service department directly at 1-800-733-8821 not your local service agent.
4
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Concepts Use & Care Manual
Specifications
This manual covers standard units only. If you have a custom unit, consult the customer service department at the number listed below.
Cashier Counter
Model Length Width Height Ship Weight
DCCS-SD 45.00” 36.00” 36.00” 270lbs/122kg
DCCS-SDW 45.00” 54.00” 36.00” 320lbs/145kg
DCCS-SDWL 45.00” 54.00” 36.00” 295lbs/134kg
DCCS-SDWR 45.00” 54.00” 36.00” 295lbs/134kg
DCCS-DD 72.00” 36.00” 36.00” 540lbs/245kg
DCCS-DDW 72.00” 54.00” 36.00” 590lbs/268kg
DCCS-DDWL 72.00” 54.00” 36.00” 565lbs/256kg
DCCS-DDWR 72.00” 54.00” 36.00” 565lbs/256kg
Flexi Shield™ Food Shields Radial Glass Fro nt, Single Tier with Glass Shelf, Singl e Serv ice, Inside & Outside
Model L W H Ship Weight Model L W H Ship Weight
DCFSRIG-2 38.47” 18.00” 18.00” Contact Factor y DCFSROG-2 43.09” 18.00” 18.00” Contact Factor y
DCFSRIG-3 53.43” 18.00” 18.00” Contact Factor y DCFSROG-3 59.85” 18.00” 18.00” Contact Factor y
DCFSRIG-4 68.17” 18.00” 18.00” Contact Factor y DCFSROG-4 76.35” 18.00” 18.00” Contact Factor y
DCFSRIG-5 82.61” 18.00” 18.00” Contact Factor y DCFSROG-5 92.53” 18.00” 18.00” Contact Factor y
Flexi Shield™ Food Shields Radial Single Tier, Fixed S neeze Guard Front, Dual S er vice
Model L W H Ship Weight
DCFSRKD-2 40.78” 35.50” 14.75” Contact Factor y
DCFSRKD-3 56.64” 35.50” 14.75” Contact Factor y
DCFSRKD-4 72.26” 35.50” 14.75” Contact Factor y
DCFSRKD-5 87.57” 35.50” 14.75” Contact Factor y
Flexi Shield™ Food Shields Radial Single Tier, Fixed S neeze Guard Front, Sing le Ser vice, Inside & Outside
Model L W H Ship Weight Model L W H Ship Weight
DCFSRIKS-2 38.47” 18.00” 14.75” Contact Factory DCFSROKS-2 43.09” 18.00” 14.75” Contact Factor y
DCFSRIKS-3 53.43” 18.00” 14.75” Contact Factory DCFSROKS-3 59.85” 18.00” 14.75” Contact Factor y
DCFSRIKS-4 68.17” 18.00” 14.75” Contact Factory DCFSROKS-4 76.35” 18.00” 14.75” Contact Factor y
DCFSRIKS-5 82.61” 18.00” 14.75” Contact Factory DCFSROKS-5 92.53” 18.00” 14.75” Contact Factor y
Specifications
Model Length Depth Height Ship Weight Model Length Depth Height Ship Weight
DCBU-38 38.00” 36.00” 36.00” 171lbs/78kg DCBU-T38 38.00” 36.00” 36.00” 171lbs/78kg
DCBU-52 52.00” 36.00” 36.00” 234lbs/106kg DCBU-T52 52.00” 36.00” 36.00” 234lbs/106kg
DCBU-66 66.00” 36.00” 36.00” 297lbs/135kg DCBU-T66 66.00” 36.00” 36.00” 297lbs/135kg
DCBU-80 80.00” 36.00” 36.00” 360lbs/163kg DCBU-T80 80.00” 36.00” 36.00” 360lbs/163kg
DCBU-94 94.00” 36.00” 36.00” 423lbs/192kg DCBU-T94 94.00” 36.00” 36.00” 423lbs/192kg
DCBU-120 120.00” 36.00” 36.00” 540lbs/245kg DCBU-T120 120.00” 36.00” 36.00” 540lbs/245kg
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
5
Concepts Use & Care Manual
Specifications, continued
Self-Contained Frost Top Serving Counter
Model Length Depth Height H.P. V/Hz/Ph Amps Ship Weight
DC-FT2 38.00” 36.00” 36.00” 1/4 115/60/1 7.5 399lbs/181kg
DC-FT3 52.00” 36.00” 36.00” 1/4 115/60/1 7.5 546lbs/248kg
DC-FT4 66.00” 36.00” 36.00” 1/4 115/60/1 7.5 693lbs/314kg
DC-FT5 80.00” 36.00” 36.00” 1/4 115/60/1 7.5 840lbs/381kg
DC-FT6 94.00” 36.00” 36.00” 1/3 115/60/1 8.0 987lbs/448kg
Heated Serving Counter
Model Length Depth Height Watts
DC-H2 38.00” 36.00” 36.00” 2000 2 115/60/1 16.6 228lbs/103kg
DC-H3 52.00” 36.00” 36.00” 3000/4000 3 208230/60/1 15.0/16.0 312lbs/142kg
DC-H4 66.00” 36.00” 36.00” 4000/4800 4 208230/60/1 20.0/22.0 396lbs/180kg
DC-H5 80.00” 36.00” 36.00” 5000/6000 5 208230/60/1 24.0/27.0 480lbs/218kg
DC-H6 94.00” 36.00” 36.00” 6000/7200 6 208230/60/1 29.0/32.0 564lbs/256kg
# of 12x20
Pans Held
V/Hz/Ph Amps Ship Weight
Ice Cooled Serving Counter
Model Length Depth Height
DC-IC2 38.00” 36.00” 36.00” 2 209lbs/95kg
DC-IC3 52.00” 36.00” 36.00” 3 286lbs/130kg
DC-IC4 66.00” 36.00” 36.00” 4 363lbs/165kg
DC-IC5 80.00” 36.00” 36.00” 5 440lbs/200kg
DC-IC6 94.00” 36.00” 36.00” 6 517lbs/235kg
Self-Contained LiquiTec® Cold Pan Serving Counter
Model Length Depth Height
DC-L2 38.00” 36.00” 36.00” 2 1/4 115/60/1 7.5 379 342lbs/155kg
DC-L3 52.00” 36.00” 36.00” 3 1/4 115/60/1 7.5 569 468lbs/212kg
DC-L4 66.00” 36.00” 36.00” 4 1/4 115/60/1 7.5 758 594lbs/269kg
DC-L5 80.00” 36.00” 36.00” 5 1/4 115/60/1 7.5 948 720lbs/327kg
DC-L6 94.00” 36.00” 36.00” 6 1/4 115/60/1 7.5 1138 846lbs/384kg
Self-Contained Mechanically Cooled Serving Counter
Model Length Depth Height
DC-MC2 38.00” 36.00” 36.00” 2 1/4 115/60/1 7.5 379 323lbs/147kg
DC-MC3 52.00” 36.00” 36.00” 3 1/4 115/60/1 7.5 569 442lbs/200kg
DC-MC4 66.00” 36.00” 36.00” 4 1/4 115/60/1 7.5 758 561lbs/254kg
DC-MC5 80.00” 36.00” 36.00” 5 1/4 115/60/1 7.5 948 680lbs/308kg
DC-MC6 94.00” 36.00” 36.00” 6 1/3 115/60/1 8.0 1138 799lbs/362kg
# of 12x20 Pans Held
# of 12x20 Pans Held
# of 12x20
Pans Held
H.P. V/Hz/Ph Amps BTU Ship Weight
H.P. V/Hz/Ph Amps BTU Load Ship Weight
Ship Weight
6
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
Loading...