Congratulations on choosing a De Dietrich product, a product of quality. We strongly recommend that you read the following instructions in
order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your
expectations.
1Used symbols
Caution danger
Risk of injury and damage to equipment. Attention must be
paid to the warnings on safety of persons and equipment
Specific information
Information must be kept in mind to maintain comfort
Refer to another manual or other pages in this instruction
Z
manual
DHW: Domestic hot water
MIT: Indoor module fitted with a Diematic 3 control panel
HP or PAC: Heat pump.
2Important recommendations
For a proper operating of the boiler, follow carefully the
instructions.
Any intervention on the appliance and heating equipment
must be carried out by a qualified technician.
The manufacturer is not liable for any improper use of the
appliance or failure to maintain or install the unit correctly
(the user shall take care to ensure that the system is
installed by a qualified fitter).
To take advantage of the pump cleaning function, do not switch
off the appliance in summer. Use the Summer mode for the
desired heating shutdown period.
See: Operating mode.
Z
If a remote control CDI 2 is connected, it will have no display
when the general switch is in the off position
2. Pressure gauge
* Depending on the model of the appliance, the pressure gauge
is manual (dial display) or automatic (pictogram display).
1Text and numerical display
2Graphic bar displaying the programme on circuit A or B (in
zone 9)
3Light area: Nighttime period
4Dark area: Daytime period
5Flashing cursor showing the current time
6Number display (current time, adjusted values, parameters,
etc.)
7Active programme display, P1, P2, P3, P4
or
E: Summer mode activated - heating OFF
8Flashing arrows when the
adjust the displayed parameter
9Circuit operation symbols
Opening the 3-way valve
>
=
Closing the 3-way valve
Displayed circuit pump on
:
A, BName of the circuit displayed
10Symbol displayed above the active operating mode
or keys should be used to
SUNDAY
bar
34567
A
BC
91011
11Symbols indicating that the following inputs/outputs are
D
X
Y
#
D
E
X
Y
8
active
ROE-II - ROE+ - SOLO - NAPO - ROI+ - ROE-H
PAC is operating in Hot or Cold mode
PAC is operating in Hot mode with additional electrical heating
at stage 1
PAC is operating in Hot mode with additional electrical heating
at stage 2
Additional electrical heating operating, stage 1. PAC off
Additional electrical heating operating, stage 2. PAC off
DHW production pending with the thermodynamic unit
Forced "summer" condition
ROE+ TH
PAC is operating in Hot mode with 1 compressor
PAC is operating in Hot mode with 2 compressor
PAC is operating in Hot mode with 2 compressors and 1 backup provision
PAC is operating in Hot mode with 2 compressors and 2 backup provision
Additional electrical heating operating, stage 1. PAC off
Additional electrical heating operating, stage 2. PAC off
DHW production pending with the thermodynamic unit
Input (per 1/2 hour) of the Daytime Temperature period
Input (per 1/2 hour) of the Nighttime Temperature period
Return key
Circuit display selection key
Active heating programme selection key (P1, P2, P3 or
P4)
3.5 Operating mode
0 2 4 6 8 1012141618202224
SUNDAY
A
Select the operating modes using the AUTO -%-$-. keys.
These keys simultaneously control all circuits connected.
To modify the operating mode (AUTO, Daytime
for only one of the heating circuits, use the remote control
corresponding to this circuit.
An override applied to the remote control takes priority over the
override selected on the central regulator.
`AUTO key = Automatic mode
Heating according to the time programme.
See: Programming.
Z
`Key
The heating operates according to the Daytime temperature,
independently of the timed programmes.
`Key
The heating operates according to the Nighttime temperature,
independently of the timed programmes.
`Key
Domestic hot water production is enabled, independently of the time
programme.
`Key
The heating is off but the installation is monitored and protected
against frost.
The antifreeze mode protects:
- The installation if the outside temperature is lower than 3°C
- The room temperature if a remote control is connected and the
= Daytime mode
%
= Night mode
$
= Tank load enabled mode
= Antifreeze mode
.
(factory setting).
room temperature is lower than 6 °C (factory setting).
or Nighttime $)
%
C000142_02
`Key
024681012141618202224
Key
function is activated, to switch to Cooling mode.
Z
This function is independent of the "automatic heating shutdown"
function in summer when the outside temperature exceeds the
outside temperature for "heating shutdown".
#
SUNDAY
is used to cut off the heating and, if the corresponding
#
See menu #HEAT PUMP, parameter REFR.:
When the heating is off during the "summer" mode, the pumps
are started up once a week for one minute in order to prevent
fouling.
The MIT interior hydraulic module operates in COOLING mode
only:
- During the
-
and
if the outside temperature is higher than the instruction
WIN
+
Do not use or modify this programme when operating with
the QUADROPAC domestic hot water tank.
-04
(Located under the flap) = SUMMER mode / Cooling
A
A
STANDARD
C000142_03
DAY
period on timed programmes A and B,
SUM/WIN BAND
(Factory setting: 22 + 4 = 26 °C).
-04
SUM/
Antifreeze protection is guaranteed for each heating circuit,
regardless of the setting on the corresponding room
temperature sensor. The room temperature in "antifreeze"
mode is preset to +6 °C. This value can be modified if a room
sensor is fitted.
Brief touchSeveral brief touches1 long touch (5 seconds)
AUTO keyDepending on the situation:
- Cancellation of the Daytime or Nighttime mode
- Confirmation of the antifreeze
setting (or after 2 minutes)
Key%/
Key
Key
Key # (Located
under the flap)
$
.
Temporary activation (Until midnight)
The arrow above the key flashes.
Temporary activation
Set the number of days' absence
(current day = 1) using keys
(up to 99 days).
The arrow above the key flashes.
Cancellation: The antifreeze mode is
cancelled when the number of
antifreeze days is reset to zero or when
the set time has elapsed.
Temporary activation (Until midnight)
The arrow above the key flashes.
__First press: Permanent activation
and
_
_
Deferred temporary activation:
- First brief touch: Set the number of
days' absence (current day = 1) using
keys
- Second brief touch: Set the start
month using keys
- Third brief touch: Set the start day
using keys
The arrow above the key flashes until
the start day and then becomes steady.
Cancellation: The antifreeze mode is
cancelled when the number of
antifreeze days is reset to zero or when
the set time has elapsed
Second depression: DeactivationPermanent activation
and (up to 99 days).
and .
and .
.
Cancels the message SHOW REM.
CTRL which signals the presence of an
override on a remote control.
The AUTO mode is forced on all
existing heating circuits.
Permanent activation
The arrow above the key is steady.
Permanent activation
The arrow above the key is steady.
The permanent "antifreeze"
mode can also be selected
using the TELCOM 2 remote
voice monitoring module
delivered as an option.
The arrow above the key is steady.
The heating is off.
The symbol SU appears.
Second depression: Deactivation