The symbols shown above are internationally accepted symbols that
warn of potential hazards with electrical products. The lightning flash
with arrowpoint in an equilateral triangle means that there are dangerous voltages present within the unit. The exclamation point in an
equilateral triangle indicates that it is necessary for the user to refer to
the owner’s manual.
These symbols warn that there are no user serviceable parts inside the
unit. Do not open the unit. Do not attempt to service the unit yourself.
Refer all servicing to qualified personnel. Opening the chassis for any
reason will void the manufacturer’s warranty. Do not get the unit wet.
If liquid is spilled on the unit, shut it off immediately and take it to
a dealer for service. Disconnect the unit during storms to prevent
damage.
Safety InStructIonS
NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.
WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A
PROTECTIVE EARTHING CONNECTION.
The cores in the mains lead are coloured in accordance with the following code:
GREEN and YELLOW - Earth BLUE - Neutral BROWN - Live
WARNING FOR YOUR PROTECTION
READ THE FOLLOWING:
KEEP THESE INSTRUCTIONS
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING
LIQUID AND NO OBJECT FILLED WITHI LIQUID, SUCH AS VASES, SHALL
BE PLACED ON THE APPARATUS.
CLEAN ONLY WITH A DRY CLOTH.
DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS,
HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT.
ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFACTURER.
UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN
UNUSED FOR LONG PERIODS OF TIME.
Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or third
prong are provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
Use only with the cart stand, tripod bracket, or table specified by the manufacture, or sold with the apparatus. When a cart is used, use caution when moving
the cart/apparatus combination to avoid injury from tip-over.
As colours of the cores in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
•
The core which is coloured green and yellow must be connected to the terminal in
the plug marked with the letter E, or with the earth symbol, or coloured green, or
green and yellow.
•
The core which is coloured blue must be connected to the terminal marked N or
coloured black.
•
The core which is coloured brown must be connected to the terminal marked L or
coloured red.
This equipment may require the use of a different line cord, attachment plug, or both,
depending on the available power source at installation. If the attachment plug needs
to be changed, refer servicing to qualified service personnel who should refer to the
table below. The green/yellow wire shall be connected directly to the units chassis.
CONDUCTOR
LLIVEBROWNBLACK
NNEUTRALBLUEWHITE
EEARTH GND
WIRE COLOR
NormalAlt
GREEN/
YEL
GREEN
WARNING: If the ground is defeated, certain fault conditions in the unit or in the system
to which it is connected can result in full line voltage between chassis and earth ground.
Severe injury or death can then result if the chassis and earth ground are touched
simultaneously.
Refer all servicing to to qualified service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord or plug
is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
POWER ON/OFF SWITCH: If the equipment has a Power switch, the Power
switch used in this piece of equipment DOES NOT break the connection from
the mains.
MAINS DISCONNECT: The plug shall remain readily operable. For rackmount or installation where plug is not accessible, an all-pole mains switch with
a contact separation of at least 3 mm in each pole shall be incorporated into
the electrical installation of the rack or building.
FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEPTACLE: Replace fuse with same type and rating only.
MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different
line cord, attachment plug, or both, depending on the available power source at
installation. Connect this equipment only to the power source indicated on the
equipment rear panel. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel or equivalent.
If connected to 240V supply, a suitable CSA/UL certified power cord shall be
used for this supply.
Page 3
IMPORTANT SAFETY INFORMATION
eLectroMaGnetIc
coMPatIBILIty
This device complies with part 15 of the FCC Rules and the Product
Specifications noted on the Declaration of Conformity. Operation is
subject to the following two conditions:
• this device may not cause harmful interference, and
• this device must accept any interference received,
including interference that may cause undesired
operation.
Operation of this unit within significant electromagnetic fields
should be avoided.
Use only shielded interconnecting cables.
u.K. MaInS PLuG WarnInG
DecLaratIon of
conforMIty
Manufacturer’s Name: dbx Professional Products
Manufacturer’s Address: 8760 S. Sandy Parkway
Sandy, Utah 84070, USA
declares that the product:
Product name: dbx SC32, SC64
Product option: Various Input / Output and Option Cards
conforms to the following Product Specifications:
Safety: IEC 60065 -01+Amd 1
EMC: EN 55022:2006
EN 55024:1998
FCC Part 15
Supplementary Information:
The product herewith complies with the requirements of
the:
A molded mains plug that has been cut off from the cord is
unsafe. Discard the mains plug at a suitable disposal facility.
NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU
INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13
AMP POWER SOCKET.
Do not use the mains plug without the fuse cover in place.
Replacement fuse covers can be obtained from your local
retailer. Replacement fuses are 13 amps and MUST be ASTA
approved to BS1362.
If you want to dispose this product, do not mix it with general household waste. There is a
separate collection system for used electronic products in accordance with legislation that
requires proper treatment, recovery and recycling.
Private household in the 25 member states of the EU, in Switzerland and Norway may return their used
electronic products free of charge to designated collection facilities or to a retailer (if you purchase a similar
new one).
For Countries not mentioned above, please contact your local authorities for a correct method of disposal.
By doing so you will ensure that your disposed product undergoes the necessary treatment, recovery and
recycling and thus prevent potential negative effects on the environment and human health.
With regard to Directive 2005/32/EC and EC Regulation
1275/2008 of 17 December 2008, this product is designed,
produced, and classified as Professional Audio Equipment
and thus is exempt from this Directive.
Roger Johnsen
Vice-President of Engineering
8760 S. Sandy Parkway Sandy, Utah 84070, USA
Date: October 11, 2010
European Contact: Your local dbx Sales and Service Office
or
Based on the principles of the dbx Zone Processing products, the SC 32 / SC 64 Digital
Matrix Processors are the new flagship products for Digital Matrix Processing. Wizard driven
configuration using HiQnet System Architect™ makes unprecedented DSP power, incredible
routing flexibility and a rich palette of processing tools accessible with the minimum of
training. The SC 32 / SC 64 represent the professional choice of foundation on which to build
even the most demanding integrated system.
With dedicated DSP for common processing functions and insert positions for specialized
processing, the SC 32 / SC 64 offer many processing functions including Advanced Feedback
Suppression (AFS™), Ambient Noise Compensation (ANC), priority ducking, parametric
equalization (PEQ), delay and dynamics. The SC 32 / SC 64 have a diverse range of control
options including HiQnet™ System Architect custom control panels, Ethernet, serial, contact
closure, the popular ZC wall controllers and even automatically scheduled events. With so
many methods of control, an SC system can truly be tailored to suit the needs and technical
expertise of even the most scrutinizing contractor.
Section 1
1.1 Defining the SC 32 / SC 64
The SC 32 has a maximum analog I/O count of 32 (the SC 64 has 64), configurable in banks
of eight. Eight card slots facilitate five different fully loaded configurations (nine in the SC
64). The analog input card accommodates a wide range of sources with mic/line switching and
phantom power per input. High-speed option slot(s) provide facility for adding forthcoming
high bandwidth audio transport I/O cards. All of these features are housed in a sleek 2U rack
chassis.
• 32/64 channels of analog I/O configurable in banks of 8
• Mic/Line and Phantom Power per channel on Analog Input Cards
• Ethernet/Serial Control
• Logic I/O
• Rich Palette of Processing Tools
• Wizard configuration
• Selectable DSP inserts on all inputs and outputs including Advanced Feedback Suppression
(AFSTM)
• Automatic Gain Compensation (AGC), Compression, De-Essing, Notch Filtering and
Parametric Equalization
• Complete routing flexibility
• Comprehensive configuration, control and monitoring from HiQnet System Architect
• Events Scheduler
• Optional ZC wall panel control
• Optional Media Engine
®
1
Page 6
Section 1
Introduction
SC 32 / SC 64
1.2 Service Contact Info
If you require technical support, contact dbx Technical Support. Be prepared to accurately
describe the problem. Know the serial number of your device - this is printed on a sticker
attached to the chassis. If you have not already taken the time to fill out your warranty
registration card and send it in, please do so now. You may also register online at www.
dbxpro.com.
Before you return a product to the factory for service, we recommend you refer to the manual.
Make sure you have correctly followed installation steps and operation procedures. For further
technical assistance or service, please contact our Technical Support Department at (801)
568-7660 or visit www.dbxpro.com. If you need to return a product to the factory for service,
you MUST first contact Technical Support to obtain a Return Authorization Number.
No returned products will be accepted at the factory without a Return Authorization Number.
Please refer to the Warranty information on the following page, which extends to the first
end-user. After expiration of the warranty, a reasonable charge will be made for parts, labor,
and packing if you choose to use the factory service facility. In all cases, you are responsible
for transportation charges to the factory. dbx will pay return shipping if the unit is still under
warranty.
Use the original packing material if it is available. Mark the package with the name of the
shipper and with these words in red: DELICATE INSTRUMENT, FRAGILE! Insure the package
properly. Ship prepaid, not collect. Do not ship parcel post.
®
2
Page 7
SC 32 / SC 64
Introduction
1.3 Warranty
This warranty is valid only for the original purchaser and only in the United States.
1. The warranty registration card that accompanies this product must be mailed within 30
days after purchase date to validate this warranty. You can also register online at
www.dbxpro.com. Proof-of-purchase is considered to be the responsibility of the consumer. A
copy of the original purchase receipt must be provided for any warranty service.
2. dbx warrants this product, when bought and used solely within the U.S., to be free from
defects in materials and workmanship under normal use and service.
3. dbx liability under this warranty is limited to repairing or, at our discretion, replacing
defective materials that show evidence of defect, provided the product is returned to dbx
WITH RETURN AUTHORIZATION from the factory, where all parts and labor will be covered up
to a period of two years. A Return Authorization number must first be obtained from dbx. The
company shall not be liable for any consequential damage as a result of the product’s use in
any circuit or assembly.
Section 1
4. dbx reserves the right to make changes in design or make additions to or improvements
upon this product without incurring any obligation to install the same additions or
improvements on products previously manufactured.
5. The foregoing is in lieu of all other warranties, expressed or implied, and dbx neither
assumes nor authorizes any person to assume on its behalf any obligation or liability in
connection with the sale of this product. In no event shall dbx or its dealers be liable for
special or consequential damages or from any delay in the performance of this warranty due to
causes beyond their control.
®
3
Page 8
Section 2
Getting Started
Section 2 - Getting Started
2.1 Front Panel
SC 32
SC 64
SC 32 / SC 64
SIGNAL
SIGNAL
SIGNAL
FRONT PANEL LED DISPLAY
Information relating to network configuration, current time and date, HiQnet™ Node Address,
SC firmware version and device status.
PAGE SELECT BUTTONS
Allow front panel navigation.
RS-232 LED
RS-232 connection indication.
CLIP LED
Global DSP clip indication.
LINK/ACT LED
Link/Activity indication. Lights steady when at least one of the Ethernet ports is linked to
an Ethernet switch; flashes when traffic activity is occurring on at least one of the Ethernet
ports.
®
4
Page 9
SC 32 / SC 64
Getting Started
POWER LED
Power present indication.
CARD POSITION LABELS - I/0 CARD TYPE INDICATION LEDS
Analog or digital, input or output indication per card position. Illuminate as shown below:
Section 2
IN
(Green)
X8 channels are analog in.
XXFuture feature.
OUT
(Orange)
X8 channels are analog out.
D-IN
(Blue)
XFuture feature.
XXFuture feature.
D-OUT
(Yellow)
DESCRIPTION
XFuture feature.
CARD POSITION LABELS - CLIP LED
Analog clip indication per channel for inputs (+19.9dB).
CARD POSITION LABELS - SYNC LED
Digital Sync indicator per card position for SC Digital Input / Ouptut Cards (coming soon).
CARD POSITION LABELS - PHANTOM POWER LED
Phantom Power indication per channel for SC Analog Input Cards.
CARD POSITION LABELS - SIGNAL LED
Signal present indication per channel for inputs (-40dB).
Allow up to eight contact closures to be used to control HiQnet™ parameters.
RELAY
Integrated relay with Normally Open (NO) and Normally Closed (NC) terminals driven from
HiQnet parameters.
®
6
Page 11
SC 32 / SC 64
Getting Started
OPTO
Opto-isolator conducts when device is powered and functioning correctly.
LOGIC OUTPUTS
Allow SC 32 / SC 64 to control up to six LEDs or relays.
ETHERNET CONNECTORS
Ethernet connectors for SC 32 / SC 64 configuration, control and monitoring. Also used for
integration with third party control systems using IP control (Integrated Ethernet switch
allows daisy-chaining of devices within a rack).
RS-232 PORT
Serial port for integration with third party control systems or for simple serial control of third
party devices such as projectors, displays and lighting controllers.
ZC PORTS
Allow connection of up to 12 ZC controllers (six per port) for control of HiQnet™ parameters.
AUDIO CONNECTOR
Balanced connections for installed I/O card. There are eight card slots in the SC 64 (slots
A-H), and four card slots in the SC 32 (slots A-D). Each I/O card uses Phoenix/Combicon
3.5mm connectors to provide balanced connections. A green LED next to a connector
indicates that it is an analog in connector, and an orange LED next to a connector indicates
that it is an analog out connector.
Section 2
I/O CARD TYPE INDICATION
Analog Input LED/Connector - Green
Analog Output LED/Connector - Orange
Digital* Input LED/Connector - Blue (coming soon)
Digital* Output LED/Connector - Yellow (coming soon)
*AES/EBU and S/PDIF
®
7
Page 12
Section 3
Wiring
Section 3 - Wiring
3.1 SC 32 and SC 64 Wiring
Audio Cable Wiring
All audio and control connections to the SC 64/32 are via 12 terminal female Phoenix
Combicon-style 3.5mm connectors, which are supplied for making these connections.
Audio Input and Output wiring convention
Balanced wiring - The convention for balanced wiring (2-wire plus shield) is:
Pin 3: Cold ‘–’
Pin 2: Hot ‘+’
Pin 1: Shield
SC 32 / SC 64SC 32 / SC 64
Unbalanced wiring - The convention for unbalanced wiring to the inputs (1-wire plus shield)
is:
Pin 1: Shield
Pin 2: Hot ‘+’
Pin 3: Link to Pin 1
Control Inputs
Used to connect switches. There are two common (ground) connections, labeled “C” to the
left of the eight CONTROL INPUTS, and two software assignable reference voltage outputs,
labeled “R” to the right of the eight CONTROL INPUTS.
Relay Contacts
Supports control of a voltage source and load that is AC, or supports control of a voltage
source and load that is higher-current DC than is supported by the logic outputs. A normally
open circuit or a normally closed circuit is available.
®
8
Page 13
SC 32 / SC 64SC 32 / SC 64
Wiring
OPTO Output
In addition to the six standard logic outputs, there is an isolated output, which fails safe
(open circuit) if the unit becomes faulty.
+supply
RELAY OPTO
LOGIC OUTPUTSCONTROL INPUTS
Section 3
1CC2 3 4 5 6
ground
7 8 R R
OPTO Output
NCCNO
+
C 1 2 3 4 5 6
-
Logic Outputs
Used to connect ‘tally’ indicator LED’s or relays. There are six standard LOGIC OUTPUTS which
produce 0V or +5V DC via an internal 440 Ohm resistor and one internally connected common
(ground) connection C. Each logic output pin can sink up to 60mA.
An LED connected between one output (Anode, A) and common (Cathode, K) will illuminate
when the logic output is activated, without requiring any external current limiting resistor.
A high sensitivity relay (such as a reed relay) may be driven by connecting four outputs in
parallel. This arrangement will develop 4V across a 500-Ohm coil, providing that all four
outputs are made logic 1 simultaneously.
1CC2 3 4 5 6
7 8 R R
RELAY OPTO
NCCNO
LOGIC OUTPUTSCONTROL INPUTS
C 1 2 3 4 5 6
+
-
LED
relay
Logic Outputs
®
9
Page 14
Section 3
Wiring
SC 32 / SC 64
3.2 Zone Controller Wiring and Installation
Zone Controller Wiring
All Zone Controllers can be wired serially or in parallel. To wire in series, each Zone Controller
must have an identification number (ID) chosen using the DIP switches on the side of the
controller (see diagram A). A single Zone Controller can be used to control multiple outputs.
Conversely, multiple Zone Controllers can be used to control a single zone (for example, a ZC1
and a ZC3 controlling volume and source in a single zone respectively). In every case, each
Zone Controller is given a unique ID.
To wire the Zone Controllers in parallel, a ZC-BOB must be used. Each Zone Controller must
have a unique identification or number chosen using the DIP switches on the side of the
controller (see diagram A). To wire in parallel, each controller must be wired into a port of the
ZC-BOB with a connecting wire going to the SC device (see diagram C).
ZC ID (1-6)ZC ID (7-12)DIP Switch Setting
17
28
39
410
511
612
To set up the Zone Controllers, the System Architect GUI must be used. Open the GUI and click
on Card Configuration within the Hardware Configuration section of the Tools menu. In this
window, Zone Controllers are assigned to ZC Inputs 1-12. The input numbers on the left side
of the window correspond to the ID number set using the DIP switches on the individual Zone
Controllers. To select ID#2 for example, simply flip the 2 switch into the on position. ID 1-6
are connected to the top ZC input on the rear panel and ID 7-12 are connected to the bottom
input. To create ID 7-12, add 6 to the ID # selected on the back of the ZC. For example, to get
an ID# of 10, connect to the bottom ZC Input (7-12) and set the ID# to 4.
10
Zone Controller Installation
The installation of the Zone Controllers MUST be accomplished with the use of cable which is
rated VW-1 or higher. Common NEC designations which meet this rating include: CMP, CMR,
CMG, CM and CMX.
®
Page 15
SC 32 / SC 64
ZC-1 - The ZC-1 is a programmable zone controller that allows input or output volume level
control from a wall panel.
ZC-2 - The ZC-2 is a programmable zone controller that allows input or output volume level and
mute control from a wall panel.
ZC-3 - The ZC-3 allows wall panel routing and Actions selection for the SC devices.
ZC-4 - The ZC-4 provides contact closure routing and Actions selection for room combining or
fire safety applications.
ZC-Fire - The ZC-Fire is the interface to generic fire alarm relays. When fire alarm activates, the
general purpose relay can typically be programmed to close if normally open or vices-versa. The
ZC-fire interface unit monitors the state of the relay (n.o. or n.c.) and upon the state of change,
notifies the SC 32/64, which then mutes its outputs.
ZC-6 - The ZC-6 is a push-button up and down input or output volume controller.
ZC-7 - The ZC-7 allows Actions selection for the SC devices.
Wiring
Section 3
ZC-8 - The ZC-8 is used for a combination of input or output volume up/down, and four position
source/program select.
ZC-9 - The ZC-9 allows wall panel routing and Actions selection for the SC devices.
ZC-BOB - The ZC-BOB allows parallel or home run cabling of the Zone Controllers.
®
11
Page 16
1
1
1
1
1
1
Section 3
Diagram A
Diagram B
Wiring
ID# 1ID# 4
SC 32 / SC 64
80-1342-A
Diagram C
80-1342-A
UL-6500
IEC60065
.
R
RJ45
INPUT
CONNECT ONLY TO
ZONE CONTRO LLE
UL-6500
IEC60065
.
R
RJ45
T
INPU
CONNECT ONLY TO
ZONE CONTRO LLE
A HARMAN INTERNATIONAL COMPANY
SALT LAKE CITY , UTAH
SC 64
FUSE REPLACEMENT RATINGS
100V-240V T 2.5A, H 250V
120 WATTS
100-240V 50/60Hz
A HARMAN INTERNATIONAL COMPANY
SALT LAKE CITY , UTAH
SC 64
FUSE REPLACEMENT RATINGS
100V-240V T 2.5A, H 250V
120 WATTS
100-240V 50/60Hz
1CC 2 3 4 5 6
7 8 R R+NCCNO-C 1 2 3 4 5 6
OPTION SLOT 2
OPTION SLOT 1
1CC 2 3 4 5 6
7 8 R R+NCCNO-C 1 2 3 4 5 6
OPTION SLOT 2
OPTION SLOT 1
RELAY OPTO
RELAY OPTO
ATTENTION:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
MOISTURE
RS-232
ATTENTION:
RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
MOISTURE
RS-232
ZC INPUTS 1 - 6
ZC INPUTS 7 - 12
ZC INPUTS 1 - 6
ZC INPUTS 7 - 12
UL60065
FOR
120V~,60Hz
INPUTS / OUTPUTS
UL60065
FOR
120V~,60Hz
INPUTS / OUTPUTS
IEC60065
ETHERNET
LOGIC OUTPUTSCONTROL INPUTS
IEC60065
ETHERNET
LOGIC OUTPUTSCONTROL INPUTS
HD
8 7 6 54321
GC
8 7 6 54321
FB
8 7 654321
EA
HD
8 7 6 54321
GC
8 7 6 54321
FB
8 7 654321
EA
8765432
8765432
8765432
8765432
8765432
8765432
12
®
Page 17
SC 32 / SC 64
Cable Specification: EIA/TIA 568A Standard (pin to pin) 24 AWG wire
Wiring
Section 3
Diagram A
RJ-45
(8-Position)
1
2
3
4
5
6
7
8
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
A HARMAN INTERNATIONAL COMPANY
SALT LAKE CITY , UTAH
SC 64
FUSE REPLACEMENT RATINGS
100V-240V T 2.5A, H 250V
120 WATTS
100-240V 50/60Hz
(8-Position)
OPTION SLOT 2
OPTION SLOT 1
1CC 2 3 4 56
7 8 R R+NCCNO-C 1 23 45 6
RJ-45
RELAY OPTO
1
3
4
5
6
7
8
LOGIC OUTPUTSCONTROL INPUTS
2
-VREF
-Dip 1
-Dip 2
-Dip 3
-Dip 4
-Dip 5
-Dip 6
-GND
RISQUE DE CHOC
ATTENTION:
ELECTRIQUE - NE PAS OUVRIR
IEC60065
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
MOISTURE
RS-232
ETHERNET
ZC INPUTS 7 - 12
INPUTS / OUTPUTS
HD
GC
FB
EA
876543218 7 6 5 4321
876543218 7 6 54321
876543218 7 654321
UL60065
FOR
120V~,60Hz
ZC INPUTS 1 - 6
Diagram B
Diagram C
A HARMAN INTERNATIONAL COMPANY
SALT LAKE CITY , UTAH
SC 64
FUSE REPLACEMENT RATINGS
100V-240V T 2.5A, H 250V
120 WATTS
100-240V 50/60Hz
A HARMAN INTERNATIONAL COMPANY
SALT LAKE CITY , UTAH
FUSE REPLACEMENT RATINGS
100V-240V T 2.5A, H 250V
100-240V 50/60Hz
INPUTS / OUTPUTS
UL60065
FOR
120V~,60Hz
INPUTS / OUTPUTS
HD
876543218 7 6 5 4321
GC
876543218 7 6 54321
FB
876543218 7 654321
EA
HD
876543218 7 6 5 4321
GC
876543218 7 6 54321
FB
876543218 7 654321
EA
OPTION SLOT 2
OPTION SLOT 1
RELAY OPTO
1CC 2 3 4 56
7 8 R R+NCCNO-C 1 23 45 6
1CC 2 3 4 56
OPTION SLOT 2
OPTION SLOT 1
RELAY OPTO
7 8 R R+NCCNO-C 1 23 45 6
SC 64
120 WATTS
RISQUE DE CHOC
ATTENTION:
ELECTRIQUE - NE PAS OUVRIR
UL60065
IEC60065
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
FOR
MOISTURE
120V~,60Hz
RS-232
ETHERNET
IEC60065
ETHERNET
ATTENTION:
ELECTRIQUE - NE PAS OUVRIR
WARNING:
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
MOISTURE
RS-232
RISQUE DE CHOC
TO REDUCE THE
ZC INPUTS 1 - 6
ZC INPUTS 7 - 12
ZC INPUTS 1 - 6
ZC INPUTS 7 - 12
LOGIC OUTPUTSCONTROL INPUTS
LOGIC OUTPUTSCONTROL INPUTS
®
13
Page 18
Section 3
Wiring
SC 32 / SC 64
SC 32 / 64.
14
®
Page 19
SC 32 / SC 64
Technical Specifications
Section 4
Section 4 - Technical Specifications
FRONT PANEL INDICATORS
Per channel: 48V (yellow), CLIP (red), SIGNAL (green)
Per 8 channel bank: IN (green), OUT (amber), D-IN (blue), D-OUT (yellow), SYNC (green)
Other: 16x2 LCD display, PAGE button (green), SELECT button (green), CLIP (red), LINK/ACT (green), RS-232 (green), POWER (green)
ANALOG INPUTS
Connectors: Phoenix/Combicon, 3.5mm pitch
Channels: Eight per card
Line/Mic Inputs: Nominal gain 0 dB
Electronically switchable to +6, +12, +18, +24, +30, +36, +42, +48 dB
Type: Electronically balanced, RF Filtered
Input Impedance: 3.5 kΩ
Maximum Input Level: +20 dBu
Noise Floor: -92 dBu “A” weighted
Dynamic Range: 110 dB “A”weighted
107 dB unweighted, 20 Hz to 20 kHz
Frequency Response: 20 Hz – 20 kHz, +0/-0.5 dB
THD+N: 0.0045% 0 dBu input, 1 kHz, 0 dB input gain
0.0065% 0 dBu input, 20 Hz – 20 kHz, 0 dB input gain
Inter-channel crosstalk: > 90 dB typically, 20 Hz - 20 kHz
Internal Processing: 32 bit floating point
Internal Sample Rate: 48 kHz
Latency: 1.82 msec analog input to analog output
2.25 msec analog input to analog output with a mono mid-mixer
CONTROL INPUTS
Connector: Phoenix/Combicon, 3.5mm pitch
Number: 8
Control Voltage Input: 0 to 4.5 VDC
Control Line Impedance: 4.7 kΩ to +5 VDC
®
15
Page 20
Section 4
ZONE CONTROLLER INPUTS
Connectors: RJ-45
Number: 2 connectors with 6 channels per connector for a total of 12 inputs
Useage: For use with dbx ZC wall controllers
LOGIC OUTPUTS
Connector: Phoenix/Combicon, 3.5mm pitch
Number: 6
Logic Output Voltage: 0 or +5 V unloaded
Logic Output Impedance: 440 Ω
Logic Output Current: 10 mA source, 60 mA sink
RELAY CONTACT CLOSURE
Connector: Phoenix/Combicon, 3.5mm pitch
Contacts: Common (C), Normally Open (NO), Normally Closed (NC)
Contact Rated Load: 0.3A at 125VAC, 1A at 30VDC
WATCHDOG OUTPUT
Connector: Phoenix/Combicon, 3.5mm pitch
Type: Opto-isolated
Output Current: 14 mA max
Withstanding Voltage: 80 V max (off)
Series Impedance: 220 Ω isolated
Technical Specifications
SC 32 / SC 64
MISCELLANEOUS
Power Requirements: 100 V to 240 VAC, 50/60 Hz
75 Watts for SC32, 120 Watts for SC64
BTU Rating: 256 BTUs maximum for SC 32, 409 BTUs maximum for SC 64
Dimensions: 3.5” tall x 19” wide x 15” deep
Weight: SC 32: 15.7 pounds (with all audio cards installed)
SC 64: 18.9 pounds (with all audio cards installed)
dbx® incorporates high quality mechanical fans in some products. All mechanical fans have a limited life expectancy. We
recommend annual inspection of fans for dust occlusion and excessive noise. Fan assemblies should be replaced after six to
ten years of use. Environmental factors such as elevated temperature, dust, and smoke can adversely affect fan life. Systems
exposed to these conditions should be inspected more frequently. Fan replacement can be performed either at the factory or by
an experienced technician in the field. Please contact dbx Technical Support for more information on purchasing replacement
parts or product service.
dbx has a policy of continued product improvement and accordingly reserves the right to change features and specifications
without prior notice.
®
8760 South Sandy Parkway • Sandy, Utah 84070
Phone: (801) 568-7660 • Fax (801) 568-7662
Int’l Fax: (801) 568-7583
Questions or comments?
Contact us at www.dbxpro.com
16
Printed in the USA
18-0616-D
®
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.