Davey UV70 Steriflo UV User Manual

Installation and Oper ating
Instructions for
Davey Steriflo
®
UV, Ultr a Violet
Water Treatment Systems
Models : UV50, UV70
Minimum operating pressure is 0kPa. Installation on a flooded suction is recommended. Installation under vacuum is not advised, any damage to persons or associated equipment will not be covered under this guarantee.
Maximum operating pressure for stainless steel UV chambers is 860kPa (125 psi). If this pressure can be exceeded or if operating close to this pressure fit a suitable pressure limiting valve in the supply to the UV chamber.
WARNING: The UV Chamber operates under pressure. Under no circumstances should the UV Chamber be disassembled unless the internal pressure of the unit has been relieved. Failure to observe this warning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property.
Ultra violet radiation is harmful to skin & eyes. DO NOT LOOK AT UV LAMP WHILE LAMP IS OPERATING.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
If any electrical supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Please pass these instructions onto the operator of this equipment.
Table of Contents
Introduction Page 3
Preparing your system Page 3
Choosing a Site Page 4
Housing your Steriflo
®
System Page 4
Power Connection Page 5
Electrical Power Surge Protection Page 5 - 6
Pipe Connections Page 6
Pre-treatment (drinking water) Page 6
Lamp Installation Page 7
Operation Page 7
Maintenance Page 8 - 9
Water Quality Page 9
Lamp Fail Alarm Page 9
Trouble Shooting Page 10
Specifications Page 10
Spare Parts Page 10
Warning - UV Radiation Page 11
After Sales Service Page 11
2
Congratulations on your purchase of a high quality, New Zealand made Steriflo
®
Ultra Violet water treatment system. All components have been designed and manufactured to give trouble free, reliable operation.
®
Your new Steriflo
system incorporates a lamp failure system design feature that
enables you to be warned of a lamp failure by :-
1. A lamp failure LED
2. An audible alarm
In addition when the alarm “beeps” on and off, the lamp is due to be changed so effective treatment is maintained. Flashing of the red LED indicates that the lamp countdown timer is operating.
Before installing your new Steriflo®, please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee. Your Ultra Violet water treatment system is designed to handle clean water free of particulate matter. The system should not be used for any other purpose without specific referral to Davey Water Products. The use of the system with flammable, corrosive and other materials of a hazardous nature is specifically excluded.
The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
NOTE: The quartz sleeve has been factory fitted, and there is no need to remove these endcaps or sleeve on first installation. Before removing sleeve, please read the Maintenance section of these instructions completely.
3
Preparing your system
On removing your Steriflo®system from its carton you should check all components, especially the lamp, to ensure all are present and have not been damaged in transportation. You should have:
1. Power supply control box with indicator light(s) and electrical flex.
2. UV lamp.
3. Treatment chamber with mounting bracket.
Choosing a Site
Choose a site with a firm mounting position. Allow room for removal of the lamp and sleeve during servicing. Leave a chamber lengths space at the lamp connector end for lamp removal. Installation can be horizontal (outlet facing upwards) or vertical (outlet horizontal).
Housing your Steriflo®System
To protect your Steriflo®system from the weather, make sure the site is water proof, frost free and has adequate ventilation. Allow for drainage, to avoid damage to flooring etc., that over time may occur from leaking pipe joints or seals.
WARNING: Some insects, such as small ants, find electrical devices attractive for various reasons. If your site or enclosure is susceptible to insect infestation you should implement a suitable pest control plan.
4
Loading...
+ 8 hidden pages