Davey TYPHOON T-Series Swimming Pool Pumps User Manual

WHISPER Series TYPHOON C-Series TYPHOON T-Series
Swimming Pool Pumps
Instruction manual
Safety precautions
This symbol together with one of the following words “Danger” or “Warning” indicates the risk level deriving from failure to observe the prescri­bed safety precautions:
DANGER risk of electric shock
DANGER
1. General
The purpose of these instructions is to ensure the correct installation and best performance of our pumps. These are single cell centrifugal pumps with built-in filter elements, especially designed for prefiltering and recirculation of water in swimming pools. They are designed to operate with clean water at a maximum temperature of 40°C. All materials used are of top quality; they are subjected to strict, controls and veri­fied to extremely demanding standards. Correct compliance with the installation and operation instructions, and with the electrical connection diagrams, will prevent motor overloads and the consequen­ces of all types that could otherwise result, consequences for which we decline all responsability.
The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
2. Installation
The installation of our electric pumps is only permitted in swimming pools or ponds that meet DIN standards VDE 0100 part 702/11.82. In case of doubt, inquire with an expert.
The pump should be installed as near as possible to water level, in horizontal position, in order to obtain a minimum suction path and reduce head losses.
It is not advisable to install the pump at more than 3 m geometrical height from water level. Independently of the geometrical height and the power of the model cho­sen, self-priming times may be up to 10 min. The pump must be fixed on a firm base, with screws of 6 or 8 mm diameter, through the prepared holes in the foot.
The pump should be protected from possible flooding and receive dry ventilation.The pump is to be installed in a manner consistent with the National Wiring Rules.
3. Installing the lines
The supports of the suction and discharge lines will be independent of those of the pump.
Warns that failure to observe the precautions involves a risk of electric shock.
Warns that failure to observe the precautions involves a risk of damage to persons and/or things.
Warns that failure to observe the precautions involves the risk of damaging the pump and/or the plant.
In the case of plastic lines, ensure tightness of joints and threads with TEFLON tape alone. Glue or similar products should not be used. The suction line should have a diameter equal to or greater than that of the suction mouth of the pump. The inside of the suction and discharge holes is threaded to a certain depth. This depth should not be exceeded when screwing on the respective lines. Only new or clean connectors should be used. The suction lines should be structured with a slight slant to prevent the formation of siphons.
4. Electrical connection
The electrical installation should have a multiple separation system with contact opening of a least 3 mm. The protection of the system will be based on an RCD (I fn = 30 mA). If outdoor operation is foreseen, the power supply cord should meet EEC standards (2) or be of type H07 RN-F as per VDE 0250.
Single-phase motors will be equipped with built-in thermal protection. In the case of three-phase motors, the user should provide thermal protection complying with the installation rules in force. The diagrams in Fig. (1) will allow correct electrical connection.
5. Verifications prior to initial start-up
After making the connections defined in the preceeding section, unscrew the filter cover and fill the pump prefilter with water to the bottom level of the suction line. Verify that the pump shaft turns freely. Verify that the mains voltage and frequency match those specified on the nameplate of the pump. Set the prefilter cover back in place and screw it to a suitable tightness. Check that the turning direction of the motor matches that specified on the fan cover. In threephase motors, if the turning direction is incorrect, reverse two supply phases on the protection panel. If the motor does not start, try to determine the cause of the irregularity by consulting the list of common faults and their possible solutions, provided in this manual. NEVER RUN THE PUMP DRY.
6. Starting
Open all the gate valves and put the motor under voltage. Wait a reasonable time to allow self-priming. Verify the breakaway current and suitable adjust the thermal relay.
7. Maintenance
Our pumps do not require any specific maintenance. It is advisable, however, to periodically clean the pump filter and to empty the pump housing in low-temperature periods through the blowoff plug. If the pump is to remain idle, it is advisable to empty and clean it, and then reinstall the filter cover with o ring lubricant on the rubber gasket, taking measures to ensure that the place where the pump is to be stored will remain dry and ventilated.
In the event of breakdown, the user must in no event handle the pump, but must contact an authorised technical service.
When the time comes to dispose of the pump, it contains no toxic or contaminating materials. The principal components are duly identified for selective breaking
If the supply cord is damaged, it must be replaced by the manufacturer or it’s service agent or a similarly qualified person in order to avoid a hazard.
.
1 - RED 2 - WHITE 3 - BLACK 4 - CAPACITOR 5 - LINE 6 - MOTOR RELAY
SINGLE PHASE SUPPLY
THREE PHASE SUPPLY
Fig. 1
L
N
1
2
3
4
6
5
M
1
~
L
N
1
2
3
4
5
M
1
~
Z
V
Y
U
415 V
W
240 V
ZXY
UVW
V/Hz esp.: See pump nameplate. Liquid Temperature: 4°C a 40°C. Storage temperature: -10°C a +50°C. Relative Air Humidity: 95% Max. Motor classe: I H max refers to the maximum total head in metres.
A
G
C
E
G
F
B
D
Q max.
H max.
230V 50Hz
WHISPER 500M 180 12.2 2 1.1 12 0.45 55 35 <70 475 115 301 108 212 312 Ø48 7.4
WHISPER 750M 230 13.5 2.9 1.2 12 0.65 55 42 <70 475 115 301 108 212 312 Ø48 7.7 WHISPER 1000M 290 14 3.8 1.5 12 0.85 55 50 <70 475 115 301 108 212 312 Ø48 8.5 TYPHOON C50M 280 13.5 3.7 1.5 16 0.8 55 45 <70 532 170 345 159 238 330 Ø48 9.4
TYPHOON C 75M 340 15 5.5 2.2 16 1.2 55 47 <70 532 170 345 159 238 330 Ø48 10.7 TYPHOON C100M 380 16.5 6.2 2.5 16 1.5 55 48 <70 532 170 345 159 238 330 Ø48 11.4 TYPHOON C150M 430 18.5 7.1 25 1.6 55 55 <80 560 170 345 159 238 330 Ø48 13.5
TYPHOON T75M 416 15 4.8 2 25 1 55 40 ---- 613 200 397 231 429 270 Ø63 15 TYPHOON T100M 435 17 7 2.8 25 1.6 55 55 70 613 200 397 231 429 270 Ø63 16.5 TYPHOON T150M 500 19 8.5 3.1 25 1.9 55 61 71 613 200 397 231 429 270 Ø63 18 TYPHOON T200M 550 19.5 9.7 3.8 30 2.2 55 64 72 613 200 397 231 429 270 Ø63 20.7 TYPHOON T300M 650 22.5 12.5 5 60 2.6 55 63 73 613 200 397 231 429 270 Ø63 20.6
(l/min)
(m)
A 1 230V
A 3 230V
C –
μF
P1
(kW)
IP
(%)
Dba
η
A
(mm)B (mm)C (mm) D (mm)E (mm) F (mm) G (mm)
± 1
Kg
+ 2 hidden pages