4
Location
The pump should be located as close to the water as practicable and mounted on a rm
base in a well-drained position, high enough to prevent any ooding. It is the installer’s
responsibility to locate the pump such that the nameplate can be easily read and it can
be readily accessed for service. The four holes in the base shall be xed on the ground
(alternatively, this can be with a rubber pad and/or mounting frame) after installing the pump.
Weather Protection
It is recommended that the pump is protected from the weather.
Power Connection
IMPORTANT INFORMATION: Your Davey pump is Double Insulated to Water Circuit. If
equipotential bonding structure is required, then a Equipotential Bonding Point is provided.
(Please refer to your local statutes and regulations for AS/NZ 3000 Wiring standards).
Davey SureFlo pool pumps are suitable for connection to a nominal 240 volt 50Hz power
supply and are equipped with a ex lead and 3 pin plug. If a power outlet is not available
within 3 metres of the pump, a 3 pin power point in a safe, dry place may need to be
provided by an electrician. Extension cords are unsafe around pools – and should be
avoided. If the supply cord of this product is damaged it must be replaced by the Dealer or
manufacturer, with genuine Davey spares.
Davey Water Products recommends that all installations are tted with
earth leakage or residual current protection devices.
CAUTION: In the interest of safety, we advise that all brands and types of pool
pumps must be installed in accordance with AS3000 wiring rules or equivalent.
In accordance with AS/NZS 60335.2.41 we are obliged to inform you that
this pump is not to be used by children or inrm persons and must not be
used as a toy by children.
Power supply to this pump needs to be through an isolating transformer
or RCD, having a rated operating current not exceeding 30mA.
If the pump and lter are located below pool water level, it is necessary to
t isolating valves in the pipe between the pump and the skimmer box and
in the return pipe between the pump and the lter.
The ttings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability
before use.
CAUTION: In order to avoid a hazard due to inadverdant resetting of the
thermal cut-out, this appliance must not be supplied through an external
switching device such as a timer, or connected to a circuit that is regularly
switched on and off by the utility.
WARNING! Ensure that an electrical isolation switch is located with easy
access so that the pump can be turned off in an emergency.