Davey SureFlo DSF750, SureFlo DSF900, SureFlo DSF1100, SureFlo DSF1350 Installation And Operating Instructions Manual

Please pass these instructions on to the operator of this equipment.
The installation of this product should be carried out by a person knowledgeable in swimming pool plumbing requirements following the installation instructions provided in this manual.
Installation and
Operating Instructions
WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage.
2
Prior to using this pump you must ensure that:
• The pump is installed in a safe environment
• The pump enclosure has adequate drainage in the event of leakage
• The pipe-work is correctly sealed and supported
• The pump is primed correctly
• The power supply is correctly connected
• All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation and Operating Instructions. Read these in their entirety before switching on this pump. If you are uncertain as to any of these Installation and Operating Instructions please contact your
Davey dealer or the appropriate Davey ofce as listed on the back of this document.
Your Davey SureFlo Pool Pump
Congratulations on your purchase of a quality product from the Davey range of Pool
equipment. You are assured of many years of reliable and efcient performance from your
Davey SureFlo pool pump backed by Davey’s three year guarantee.
The Davey SureFlo pool pump has been designed to circulate swimming pool water in conditions set out in the Australian Standard for swimming pool water quality (AS 3633)
or equivalent. They should not be used for any other purpose without rst consulting your
Davey Dealer or the Davey Customer Service Centre.
Every Davey SureFlo pool pump is thoroughly tested against a number of pressures, voltage, current and mechanical performance parameters. Davey`s advanced pump
manufacturing technology provides reliable and efcient pumping performance that lasts
and lasts.
3
Davey SureFlo Pool Pump – Hydraulic Performance:
0 50 100 150 200 250 300 350 4 00 450 500
20
24
16
12
8
4
0
DSF750
DSF900
DSF1100
DSF1350
TOTAL HEAD (m)
FLOW (lpm)
Model
Q
MAX
(L/min)
HMAX
(m)
Power (P
1
) Power (P2)
Amps
Net Weight
(kg)
kW HP kW HP
DSF750 325 12.5 0.75 1.0 0.55 0.75 3.8 10.0
DSF900 370 15.0 0.9 1.2 0.65 0.85 4.6 10.5
DSF1100 390 16.5 1.1 1.5 0.75 1.0 5.8 11.5
DSF1350 445 17.0 1.35 1.8 1.0 1.35 6.2 12.0
4
Location
The pump should be located as close to the water as practicable and mounted on a rm base in a well-drained position, high enough to prevent any ooding. It is the installer’s
responsibility to locate the pump such that the nameplate can be easily read and it can
be readily accessed for service. The four holes in the base shall be xed on the ground
(alternatively, this can be with a rubber pad and/or mounting frame) after installing the pump.
Weather Protection
It is recommended that the pump is protected from the weather.
Power Connection
IMPORTANT INFORMATION: Your Davey pump is Double Insulated to Water Circuit. If
equipotential bonding structure is required, then a Equipotential Bonding Point is provided. (Please refer to your local statutes and regulations for AS/NZ 3000 Wiring standards).
Davey SureFlo pool pumps are suitable for connection to a nominal 240 volt 50Hz power
supply and are equipped with a ex lead and 3 pin plug. If a power outlet is not available
within 3 metres of the pump, a 3 pin power point in a safe, dry place may need to be
provided by an electrician. Extension cords are unsafe around pools – and should be
avoided. If the supply cord of this product is damaged it must be replaced by the Dealer or manufacturer, with genuine Davey spares.
Davey Water Products recommends that all installations are tted with
earth leakage or residual current protection devices.
CAUTION: In the interest of safety, we advise that all brands and types of pool pumps must be installed in accordance with AS3000 wiring rules or equivalent.
In accordance with AS/NZS 60335.2.41 we are obliged to inform you that
this pump is not to be used by children or inrm persons and must not be
used as a toy by children.
Power supply to this pump needs to be through an isolating transformer or RCD, having a rated operating current not exceeding 30mA.
If the pump and lter are located below pool water level, it is necessary to t isolating valves in the pipe between the pump and the skimmer box and in the return pipe between the pump and the lter.
The ttings on this product are constructed of ABS. Some PVC jointing compounds are incompatible with ABS. Check compound suitability
before use.
CAUTION: In order to avoid a hazard due to inadverdant resetting of the thermal cut-out, this appliance must not be supplied through an external switching device such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
WARNING! Ensure that an electrical isolation switch is located with easy access so that the pump can be turned off in an emergency.