Davey RainBank KRB1NF, RainBank KRB2NF Setup Instructions

Floatless RainBank® (FL)
KRB1NF & KRB2NF
Set-up Instructions
AUSTRALIA
Davey Support Centre
6 Lakeview Drive, Scoresby, Australia 3179 Ph: 1300 367 866 Fax: 1300 369 119
Davey Water Products Pty Ltd Member of the GUD Group ABN 18 066 327 517
® Davey and RainBank are registered trademarks of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2014.
Website: davey.com.au
NEW ZEALAND
Davey Support Centre
7 Rockridge Avenue, Penrose, Auckland 1061 Ph: 0800 654 333 Fax: 09 527 7654 Website: daveynz.co.nz
2009 WINNER
P/N 402330
Save time, save a call back
Mains W
rT
ater Level
IMPORTANT: For trouble free function you MUST set up your RainBank in accordance with these instructions.
Why?
Here is how to get it right…
Make sure the top of the pump is LOWER than the discharge point.
TIP: This is easier if you have your pump and Rainbank close to the tank.
ü
Like this…
Not like this…
Trying to lift water from an in-ground tank.
ate
Air gets trapped and can’t be released. Pump loses prime and cannot pump water until reprimed.
o Toilets
and Laundry
W
Or this…
Tank water level is higher than top of the pump.
Pump is higher than the lowest level of the water in the tank.
Finally…
If you are encountering issues with your system how can you fix it?
1. Modify the installation so that top of the pump is below lowest water level
2. Fit and adjust a Davey Float Switch. (P/N 13961)
Refer to the full installation & operating instructions for advice on how to t an external oat switch.