Sensing range 20 ... 60 mm , optimal distance: 45 mm
Transducer frequency 255 kHz
Indicators/operating means
LED green indication: single sheet detected
LED yellow Indication: No sheet detected (Air)
LED red indication: double sheet detected
Electrical specifications
Model Number
UDC-18GM50-255-3E3
Features
• Ultrasonic system for reliable
detection of no, one, or two
overlapping sheet materials,
preferably papers
• Short version
• No TEACH-IN required
• Function indicators visible from all
directions
• Insensitive to printing, colors, and
shining surfaces
2
• Material weight from 10 g/m
over 2000 g/m
2
• Very wide material spectrum,
finest papers up to thin sheet
metals as well as plastic- and
metal foils
• Perpendicular or inclined sensor
mounting relative to the sheet
plane possible
• Programmable
up to
Operating voltage U
No-load supply current I
Time delay before availability t
Input
Input type Function input
Pulse length ≥ 100 ms
Impedance ≥ 4 kΩ
Output
Output type 3 switch outputs PNP, NC
Rated operating current I
Voltage drop U
Switch-on delay t
Switch-off delay t
Pulse extension min. 120 ms programmable
Ambient conditions
Ambient temperature 0 ... 60 °C (32 ... 140 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PVC , 2 m
Core cross-section 0.14 mm
Degree of protection IP67
Material
Supplementary information Switch settings of the external programming adapter:
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
CSA approval cCSAus Listed, General Purpose, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated ≤36 V
B
0
v
e
d
on
off
18 ... 30 V DC , ripple 10 %
< 50 mA
< 500 ms
0-level: -U
1-level: +U
3 x 100 mA , short-circuit/overload protected
≤ 2 V
approx. 15 ms (shorter response time on request)
approx. 15 ms (shorter response time on request)
"output load": pull-down
"output logic": inv
IEC 60947-5-2:2007 + A1:2012
... -UB + 1V
B
- 1 V ... +U
B
2
SS
B
Diagrams
Mounting/Adjustment
Recommended distances
a
= 5 ... 15 mm
b
≥ 10 mm
d
= 40 ... 45 mm
d
a
Release date: 2017-09-07 16:16 Date of issue: 2017-09-07 186657_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
b
1
Page 2
Double sheet sensorUDC-18GM50-255-3E3
Dimensions
wires 70 mm with
wire end ferrules
l = 2 m
l = 0.5 m
ø 15
70
LEDs
500
Additional Information
Mounting/Adjustment
Evaluation unit with
receiver unit
4
24
M18 x 1
30
50
53
Emitter unit
24
M18 x 1
22
(for very thick papers)
b
β
a
Angular misalignment
< +/- 1°
α
Sensor offset
s < +/- 1 mm
β = 35˚
d
α
s
Electrical Connection
Standard symbol/Connection:
Double sheet control
(BN)
(PK)
(WH)
(BK)
U
(GY)
(BU)
Accessories
UC-PROG1-USB
Programming adapter
UDB-Cable-2M
MH-UDB01
Mounting bracket for double sheet monitor
UDB-Cable-1M
+U
B
Function input
Output single sheet
Output double sheet
Output air
-U
B
V15S-G-0,3M-PUR-WAGO
Male cordset, M12, 5-pin, PUR cable with WAGO terminals
Ultraschall-Sensoren DTM
DTM devices for communication with cube style and UMC... sensors
PACTware 4.1
FDT Framework
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2017-09-07 16:16 Date of issue: 2017-09-07 186657_eng.xml
Page 3
Double sheet sensorUDC-18GM50-255-3E3
Description of sensor functions
The ultrasonic double-sheet sensor for the detection of double sheets is used in any situation, where it is essential that a means be
provided for the automatic distinction between double and single sheets, in order to protect machinery and/or to avoid waste. The double-sheet sensor is based on the ultrasonic single pass principle. The following situations can be detected:
- No sheet, i.e. air
- Single sheet
- Double sheet
The evaluation of the signal is carried out with a microprocessor system. As a consequence of the evaluation the corresponding switch
outputs are set. Changing ambient conditions, such as temperature and humidity, are automatically compensated. The evaluation electronics system is built into an evaluation unit, together with a sensor head, and contained in a compact M18 metal housing.
Interface
The sensor has 6 connections. The function of the connections is shown in the following table. The function input (PK) is used to parameterize the sensor. (see Output pulse expansion, alignment aids and program select). During operation, the function input must
always be permanently connected to +U
ColorInterfaceNote
BN+U
WHSwitching output, single sheet Pulse width corresponding to the event
BKSwitching output, double sheet Pulse width corresponding to the event
GYSwitching output airPulse width corresponding to the event
PK-U
BU-UB
B
B
/+U
B
or -UB to prevent possible faults or malfunctions.
B
Function input (PK) for parameterization/
pulse extension.
Normal mode
The sensor operates in normal mode if the function input (PK) is set to -UB or +UB when the supply voltage is applied (power on) as
specified in the output pulse expansion table (see below).
Display:
Yellow LED:Air detection
Green LED:Single sheet detection
Red LED:Double sheet detection
Switching outputs:
The switching outputs are only active in normal mode!
White:WHSingle sheet output
Black:BKDouble sheet output
Gray:GYAir output
Output pulse expansion
A minimum pulse width of 120 ms can be selected for all the output pulses of the three switching outputs by connecting the function
input (PK) to +U
Interface (PK)Switching behavior (after power on)
-U
+U
.
B
B
B
No output pulse expansion of switching outputs
Output pulse expansion of all switching outputs to a minimum of 120
ms
Caution!
This can lead to a situation where more than one switching output is switched through!
Programs
The sensor has 4 programs for different application areas which allow the detection of a wide range of materials. The user can select
the program most suited to the relevant application.
The default setting program 1 is selected so that the settings of the majority of applications do not need modifying.
Program numbers Notes*Material spectrum
1Default setting standard papers
2Thick papers, cardboard packaging, fine corru-
gated cardboard (DIN 55 468-1) and thin metal
sheeting**
3Thin papers
4Extra fine papers
*) Measurements were taken under the following conditions: d = 45 mm, a = 10 mm, β = 0°
**) Measurements were taken under the following conditions: d = 45 mm, a = 10 mm,
100 - 2000 g/m
β
= 35°
Adjustment options using the function input
The diagram below shows the adjustment options using the function input.
Release date: 2017-09-07 16:16 Date of issue: 2017-09-07 186657_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
> 300 g/m
50 – 350 g/m
< 100 g/m
2
2
2
2
3
Page 4
Double sheet sensorUDC-18GM50-255-3E3
a
... and set function input (PK)
to +U
or -U
B
Power ON
... and function input
(PK) unconnected
Programming
-U
Amplitude control
(yellow LED)
display
B
B
-U
B
Normal operation
Programming
display
Program select
(green LED)
-U
+U
B
B
Function input
(PK) unconnected
Activate/Deactiv
output pulse
expansion
+U
Programming mode
B
No functionToggle cyclically
+U
B
next program
Program display
The preset sensor program can be displayed by disconnecting the function input (PK) from the power supply during normal operation.
The green LED indicates the program number (number of flashing pulses (1...4) = program number).
The outputs are inactive during this time.
If the function input (PK) is disconnected from the power during operation due to a fault (cable break, vibrations), the program display
also serves as a fault display. Switching to programming mode is not possible.
Programming mode
To activate programming mode,
the function input (PK) must be disconnected from the power when the supply voltage is applied (power on). The flashing green LED
connected to the sensor indicates the preset program first (number of flashing pulses (1...4) = program number).
By briefly setting the function input (PK) to -Ub (>500ms), the system is able to toggle cyclically between the amplitude control and the
program select.
When you disconnect the supply voltage, you exit programming mode and the current selected program setting is applied.
The switching outputs are deactivated while the sensor is parameterized!
Amplitude control
During installation, the amplitude control can be used to check whether the ultrasonic amplitude at the receiver is sufficient.
If the transmitter is not aligned properly in relation to the receiver, maximum sound energy is not transmitted to the receiver, which
may result in the incorrect detection of materials.
If the sensor detects the air section (yellow LED lights up), the UDC begins to display the strength of the measured amplitude signal:
- if the signal is weak, the yellow LED flashes infrequently
- the flashing frequency increases in line with the signal strength
- the yellow LED lights up continuously when the signal strength is sufficient.
The single-sheet (green LED) and double-sheet (red LED) functions remain active so that the function of the double sheet control can
be checked.
Program select
In program select mode, briefly setting the (PK) to +Ub (>500ms) selects the next program cyclically (number of flashing pulses from
the green LED = program number). Program changes do not interrupt flashing sequences that have already started.
Note:
A complete device consists of one ultrasonic sensor and one evaluation unit with the ultrasonic receiver. The sensor heads are optimally matched to each other in the ex-works condition and should therefore not be used separately. The connector disconnection point
on the transmitter/receiver connection cable is merely provided to simplify assembly.
Very light papers (e.g. tissues) and paper with perforations are never suitable for double sheet detection for physical reasons.
On installation, care should be taken, that the ultrasonic signal cannot pass around the material to be detected due to multiple reflec-
tions. This can happen if, for example, there are large surfaces capable of reflecting the sound at right angles to the direction of propagation of the sound. This can be the case when unsuitable clamping devices are used, or may be due to plant components with large
surfaces. In the case of reflecting plant components, these must either be clad with sound-absorbing material, or an alternative mounting location found for the sensor.
If a number of double sheet sensors are used in close proximity to each other, mutual interference may occur, leading to device malfunction. Mutual interference can be avoided by suitable countermeasures implemented when planning the system.
Parameterization using PACTwar e DTM
The double sheet sensor can be connected using a V15S-G-0.3M-PUR-WAGO terminal adapter.
Release date: 2017-09-07 16:16 Date of issue: 2017-09-07 186657_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Page 5
Double sheet sensorUDC-18GM50-255-3E3
M12 socket for
the UC-PROG1
V15S-G-0.3M-PUR-WAGO
Connection cable for
the double sheet sensor
Connect the sensor to the terminal adapter according to the table below.
Terminal adapter wire colorSensor cable wire color
BrownBrown
BlueBlue
BlackBlack
GrayPink
The sensor features a time lock. If no communication request occurs, the time lock blocks parameterization of the sensor 30 seconds
after the supply voltage is connected. Start PACTware before switching on the sensor so that the communication request can be made
in time.
Release date: 2017-09-07 16:16 Date of issue: 2017-09-07 186657_eng.xml