Description
The MIM-93M1AKL is 37.9 KHZ miniaturized infrared
receivers for remote control and other appplications
requiring improved ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
Features
l Photo detector and preamplifier in one package
l Internal filter for PCM frequency
l High immunity against ambient light
l 5-Volt supply voltage; low power consumption
l TTL and CMOS compatibility
BLOCK DIAGRAM
ABLC
Unity Opto Technology Co., Ltd.
TRAP BPF
f
TRIMMING
unit : mm
V
S
Output
GND
07/06/2000

Absolute Maximum Ratings
Fig 2. Standard Transmitter Measurement circuit
: indicates horizontal and vertical directions
Item Symbol Ratings Unit Remark
Supply voltage V
Operating temperature T
Storage temperature T
Soldering temperature T
5.8 V
-10 ~ + 60 °C
-20 ~ + 75 °C
260 °C Maximum 5 seconds
Electro-optical characteristics (Vcc=5V)
(Ta=25°C , Vcc=5V)
Parameter Symbol Min. Typ. Max. Unit Remarks
Current consumption Icc 5.0 mA Under no signal
Response wavelength p 940 nm
Tuning frequency
f
0
37.9
KH
Z
Output form - - - - - active low output - - - - -
H level output voltage V0h 4.2 V
L level output voltage V0l 0.5 V
H level output pulse width Twh 400 800 s
L level output pulse width Twl 400 800 s
Distance between emitter & detector L 10.0 m Note 1
Half angle ±45 deg Horizonal direction
Test Method
A. Standard Transmitter
ON/OFF pulse width satisfied from 25 cm to detection limit
carrier frequency f
duty 50%
0
600µs
Fig 1. Burst Wave
600µs
600µs
Transmitter
Duty 50%
10µF
PD3516
10kΩ
Oscilloscope
GND
B. Detection Length Test
Transmitter output
Unity Opto Technology Co., Ltd.
V
out
D.U.T
L
7/6/00

B. Detection Length Test
Transmitter output
DUT output pulse
600µs
600µs
C. Pulse Width Test
MIE-544A2
CHARACTERISTIC CURVES (TA=25)
2.8
2.7
2.6
2.4
2.2
Supply Current Icc (mA)
2.0
2 3 4 5
Supply Voltage Vcc (V)
6
Twl
V0h
MIM-93M1AKL
3
V0l
Twh
1
2
*) only necessary to supress power supply disturbances.
**) tolerated supply voltage range : 4.1V < Vcc < 5.8V
900
s)
µ
(
800
PW
700
600
Output Pulse Width t
500
400
7 8
Input Level VIN (mV
0.1
Vcc **)
Decoder
GND
Burst length * 600µs, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
)
P-P
1 10 100
Input Level (mV
)
p-p
1000
SUPPLY VOLTAGE vs. SUPPLY CURRENT
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
Unity Opto Technology Co., Ltd.
INPUT LEVEL vs.OUTPUT PULSE WIDTH
07/06/2000

Reliability
Test item Test condition Standard
High temparature
High temp. & high humi. Ta=+40°C 90%RH Vcc=5.0V t=240H Note 2.
Low temparature Ta= -10°C Vcc=5.0V t=240H Note 2.
Heat cycle -20°C(0.5H) ~ +75°C(0.5H) 20cycle Note 2.
Dropping Test devices shall be dropped 3 times naturally Note 3.
NOTE 2. (electro-optical charactistics) shall be satisfied sfter leaving 2 hours in the
normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Ta=+60°C Vcc=5.0 V t=240H
onto hard wooden board from a 75cm height position.
Note 2.
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
MIM-93M1AKL
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Unity Opto Technology Co., Ltd.
7/6/00

Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
MIM-93M1AKL
Unity Opto Technology Co., Ltd.
7/6/00