Datasheet LPS40 Datasheet (ASTEC)

Page 1
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
80
Special Features
40 Watts
LPS40 Series
Electrical Specs
• Universal input
• 3” x 5” footprint
• Remote sense
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Input
Input range 85-264 VAC
120-300 VDC Frequency 47-440 Hz Inrush current <18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C Input current 1 A max. (RMS) @ 115 VAC Efficiency 70% typical at full load EMI filter FCC Class B conducted
CISPR 22 Class B conducted
EN55022 class B conducted
VDE 0878 PT3 class B conducted Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power 40 W for convection;
55 W with 30 CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms @40 W load, 115 VAC
nominal line Overload protection Short circuit protection on all
outputs. Case overload protected @
110-145% above peak rating Overvoltage protection 5 V output: 5.7 to 6.7 VDC. Other
outputs 10% to 25% above
nominal output Remote sense Compensates for 0.5 V lead drop
min. Will operate without remote
sense connected. Reverse
connection protected.
VDE 0805/EN60950 (IEC950) 11774-3336-1241
(LC# 84936)
UL UL1950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P94100375
(74-sec) 203
CB Certificate and report 1119,1125,1126,1127 CE Mark (LVD)
Environmental
Safety
Total Power: 40-55 Watts Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Page 2
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
81
www.astecpower.com
Ordering Information
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple Number Voltage Load Convection Cooling 30 CFM Forced Air Load1 P/P (PARD)3
LPS41 3.3 V 0 A 8 A 11 A 12 A ±2% 33 mV LPS42 5 V 0 A 8 A 11 A 12 A ±2% 50 mV LPS43 12 V 0 A 3.3 A 4.5 A 5 A ±2% 120 mV LPS44 15 V 0 A 2.6 A 3.6 A 4 A ±2% 150 mV LPS45 24 V 0 A 1.7 A 2.3 A 2.5 A ±2% 240 mV LPS48 48 V 0 A 0.9 A 1.2 A 1.3 A ±2% 480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Connector LPS41 LPS42 LPS43 LPS44 LPS45 LPS48
SK1-1 Neutral Neutral Neutral Neutral Neutral Natural SK1-3 Line Line Line Line Line Line
SK2-1 +3.3 V +5 V +12 V +15 V +24 V +48 V SK2-2 +3.3 V +5 V +12 V +15 V +24 V +48 V SK2-3 +3.3 V +5 V +12 V +15 V +24 V +48 V SK2-4 Common Common Common Common Common Common SK2-5 Common Common Common Common Common Common SK2-6 Common Common Common Common Common Common SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense
Mating Connectors
AC Input: Molex 09-50-8031 (USA)
09-91-0300 (UK) PINS: 08-58-0111
DC Outputs: Molex 09-50-8061 (USA)
09-91-0600 (UK) PINS: 08-58-0111
Remote Sense: Molex 22-01-2025
PINS: 08-50-0114
Astec Connector Kit #70-841-006, includes all of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated.
6. Warranty: 1 year
7. Weight: 0.5 lb. / 0.23 kg
Pin Assignments