Datasheet IHB60T480515, IHB60T480312, IHB60T240515, IHB60T240512, IHB60T240315 Datasheet (cdtechno)

...
Page 1
Corporate: www.cd techno.com
Corporate: www.cd techno.com
Product: www.cdpowerelectronics.com
IHB60T
60 Watt Triple Output Half Brick DC/DC Converter
18 - 40 & 33 - 75V Input
Range
Each Channel Independently
Current Limited
High Efficiency: 87% Typical1500VDC Isolation Between
Input and Output
Operation to 100°C Baseplate
Temperature
50µS Transient Recovery,
0-90% Load Step
Primary & Secondary Remote
On/Off
IHB60T48 Series Approved to
UL/CUL 1950, EN60950
The IHB60T series triple output standard half brick modules are de­signed for today’s demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output volt­ages and minimal need for minimum loading on main (V1) output.
PRODUCT SELECTION CHART
INPUT
VOLTAGE RATED VOUT (VDC) RATED MAXIMUM IOUT (A)
MODEL (VDC) V1 (±) V2 (±) V3 (±) V1(±) V2(±) V3(±)
IHB60T240312 24 (18-40) 3.3 12 12 18 2.5 2.5 IHB60T240315 24 (18-40) 3.3 15 15 18 2.0 2.0 IHB60T240512 24 (18-40) 5.1 12 12 12 2.5 2.5 IHB60T240515 24 (18-40) 5.0 15 15 12 2.0 2.0 IHB60T480312 48 (33-75) 3.3 12 12 18 2.5 2.5 IHB60T480315 48 (33-75) 3.3 15 15 18 2.0 2.0 IHB60T480512 48 (33-75) 5.1 12 12 12 2.5 2.5 IHB60T480515 48 (33-75) 5.0 15 15 12 2.0 2.0
ABSOLUTE MAX.
RA TINGS
Output Short-Circuit Duration Continuous
Baseplate Temperature +100°C Lead Temperature
(soldering, 10 seconds max) +300°C Storage Temperature +125°C Input to Output Isolation 1500 VDC
EFFICIENCY vs TEMPERATURE
T
= +40°C, nominal input voltage, nominal load, recommended external
CASE
components applied, unless otherwise specified.*
Change in Efficiency (%)
Case Temperature (°C)
Page 2
SPECIFICATIONS, ALL MODELS
Specifications are at T
PARAMETER CONDITIONS MIN TYP MAX UNITS
Voltage Range
IHB60T24XX Series 18 24 40 V
IHB60T48XX Series 33 48 75 VDC Reflected Ripple Current Peak - Peak 220 mA Input Ripple Rejection DC to 1KHz 50 60 dB Maximum Input Current Output Power = 60W
IHB60T24XX Series V
IHB60T48XX Series V
INPUT
No Load Power Dissipation P Inrush Charge
IHB60T24XX Series 0.29 mC
IHB60T48XX Series 0.165 mC Quiescent Operating Current Primary On/Off Disabled 7.5 10 mA
Secondary On/Off Disabled 15 25 mA
PARAMETER CONDITIONS MIN TYP MAX UNITS
ISOLATION
Input to Output Peak Test 1500 V Input to Baseplate 1500 VDC Channel to Channel Any Channel to Any Channel 500 VDC Resistance, Input - Output 10 M Capacitance, Input - Output 2000 pF
Leakage Current V
GENERAL
Set Point Accuracy V Turn-on Time Within 1% of Nominal V Remote On/Off Control Inputs Primary Open Collector/Drain Sink Current-Logic Low V Vlow 0.8 V Vhigh Open Collector Secondary Open Collector/Drain Sink Current-Logic Low 100 µA Vlow 0.4 V Vhigh Open Collector
GENERAL
External Synchronization Input Frequency 440 520 KHz Pulse Width 150 320 nSec Source Impedence 47 Input High Voltage 4 5 V Input Low Voltage 0 1 V Input Impedance 470 Switching Frequency 470 480 490 KHz
Weight 3 (85) oz (g)
TEMPERATURE Case Temperature
Operation/Specification -40 +100 °C Storage -55 +125 °C Shutdown +100 +115 °C
Thermal Inpedance Case to Ambient 8.2 °C/W
= +40°C nominal input voltage unless otherwise specified.
CASE
= 16V 6 A
IN
= 30V 3 A
IN
= 0, V
OUT
IN, Min<VIN<VIN, Max
= 240VAC, 60Hz 180 µA, rms
ISO
= Nominal, 50% Load 1 %
IN
= V
IN
OUT
MAX
6W
3.5 5 mSec
7mA
DC
DC
PARAMETER CONDITIONS
V1 V2 V3 UNITS
Min Nom Max Min Nom Max Min Nom Max
Output Power Total Combined O/P Power =
60 Watts Max. 30 60 15 30 15 30 W Set Point Voltage I Output Current, I Output Ripple, p-p DC to 20MHz
OUT
Output Adjust Range
O Nom
* 3.15 3.80 Dependent on V1 V
* 100 200 150 250 150 250 mV
3.3 12.2 12.2 V
0.5 9 18 0 1.25 2.5 0 1.25 2.5 A
Output Temperature Drift .02 .05 .02 .05 .02 .05 %/°C Line Regulation V
Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 23 5.0 5.0 A
IN, Min≤VIN≤VIN, Max
IO = I
O, Nom
0.05 1.0 1.0 2.0 1.0 2.0 % See Regulation Curves See Regulation Curves
Short-Circuit Current 19 25 4.0 5.0 4.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V
IHB60TX0312** OUTPUT
Overvoltage Limit 4.2 5.0 V Efficiency I
OUT1
, 1% of V
OUT
=9A, (I
F.L. V
OUT, Nom
)=2.5A 85 86 %
OUT2+IOUT3
=Nominal
IN
35 50 µSec
* See Application Notes available on the web at www.cdpowerelectronics.com **X = Either 24 or 48
Product: www.cdpowerelectronics.com
IHB60T REV A 10/01
2
Page 3
SPECIFICATIONS, ALL MODELS
Specifications are at T
PARAMETER CONDITIONS
Output Power Total Combined O/P Power =
Set Point Voltage I Output Current, I Output Ripple, p-p DC to 20MHz Output Adjust Range See Application Notes Output Temperature Drift .02 .05 .02 .05 .02 .05 %/°C Line Regulation V
Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 23 4.0 4.0 A Short-Circuit Current 19 25 3.2 4.0 3.2 4.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V Overvoltage Limit 4.2 5.0 V
IHB60TX0315** OUTPUT
Efficiency I
= +40°C nominal input voltage unless otherwise specified.
CASE
V1 V2 V3 UNITS
Min N o m Max Min N om Max Min Nom Max
60 Watts Max. 30 60 15 30 15 30 W
3.3 15.85 15.85 V
0.5 9 18 0 1 2 0 1 2 A
OUT
O Nom
* 100 200 125 250 125 250 mV
* 3.15 3.80 Dependent on V1 V
IN, Min≤VIN≤VIN, Max
OUT1
, 1% of V
OUT
=9A, (I
F.L. V
IO = I
OUT2+IOUT3
=Nominal
IN
O, Nom
OUT, Nom
)=2A 85 86 %
0.05 1.0 1.0 2.0 1.0 2.0 %
35 50 µSec
See Regulation Curves See Regulation Curves
PARAMETER CONDITIONS
V1 V2 V3 UNI TS
Min Nom Max Min Nom Max Min Nom Max
Output Power Total Combind O/P Power =
60 Watts Max 30 60 15 30 15 30 W Set Point Voltage I Output Current, I Output Ripple, p-p DC to 20MHz
OUT
Output Adjust Range
O Nom
* 4.75 5.50 Dependent on V1 V
* 125 200 150 250 150 250 mV
5.1 12 12 V
0.5 6.0 12 0 1.25 2.5 0 1.25 2.5 A
Output Temperature Drift .02 .05 .02 .05 .02 .05 %/°C Line Regulation V
Load Regulation Min Load to Rated Load 0.50 1.0 %
IN, Min≤VIN≤VIN, Max
IO = I
O, Nom
0.05 0.10 1.0 2.0 1.0 2.0 % See Regulation Curves
See Regulation Curves
Current Limit Inception Other Outputs Min Load 16 5.0 5.0 A Short-Circuit Current 12.6 16 4.0 5.0 4.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V Overvoltage Limit 6.0 6.8 V
IHB60TX0512** OUTPUT
Efficiency I
PARAMETER CONDITIONS
OUT1
, 1% of V
OUT
=6A, (I
F.L. V
OUT, Nom
)=2.5A 86 87 %
OUT2+IOUT3
=Nominal
IN
35 50 µSec
V1 V2 V3 UNITS
Min Nom Max Min Nom Max Min Nom Max
Output Power Total Combined O/P Power =
60 Watts Max 30 60 15 30 15 30 W Set Point Voltage I Output Current, I Output Ripple, p-p DC to 20MHz
OUT
Output Adjust Range
O Nom
* 4.60 5.50 Dependent on V1 V
* 100 200 125 250 125 250 mV
5.0 15.3 15.3 V
0.5 6 12 0 1 2 0 1 2 A
Output Temperature Drift .02 .05 .02 .05 .02 .05 %/°C Line Regulation V
Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 16 4.0 4.0 A
IN, Min≤VIN≤VIN, Max
IO = I
O, Nom
0.05 0.10 1.0 2.0 1.0 2.0 % See Regulation Curves See Regulation Curves
Short-Circuit Current 12.6 16 3.2 4.0 3.2 4.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V Overvoltage Limit 6.0 6.8 V
IHB60TX0515** OUTPUT
Efficiency I
OUT1
, 1% of V
OUT
=6A, (I
F.L. V
OUT, Nom
)=2A 86 87 %
OUT2+IOUT3
=Nominal
IN
35 50 µSec
* See Application Notes available on the web at www.cdpowerelectronics.com **X = Either 24 or 48
Product: www.cdpowerelectronics.com
IHB100T REV A 10/01
3
Page 4
MECHANICAL
PIN SIDE DOWN
PIN SIDE UP
SIDE VIEW
PIN CONNECTIONS
1 PRIMARY ON/OFF 2-VIN 3+VIN 4 SYNC IN 5 -V2 6 +V2 7 TRIM 8 +V1 9 -V1 10 SECONDARY ON/OFF 11 +V3 12 -V3
NOTES:
All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability.
C&D Technologies (Power Electronics) Ltd.
Shannon, Co. Clare, Ireland
T el: +353.61.474.133 Fax:+353.61.474.141
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
Product: www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.770.9369
IHB60T REV A 10/01
C&D Technologies, (NCL)
Milton Keynes MK14 5BU UK
T el: +44 (0)1908 615232 Fax: +44 (0)1908 617545
4
Loading...