High Efficiency: 87% Typical
1500VDC Isolation Between
Input and Output
Operation to 100°C Baseplate
Temperature
50µS Transient Recovery,
0-90% Load Step
Primary & Secondary Remote
On/Off
IHB60T48 Series Approved to
UL/CUL 1950, EN60950
The IHB60T series triple output standard half brick modules are designed for today’s demanding industrial applications. Available in two
wide range inputs, these isolated converters offer many features in the
standard models. With a complement of safety agency approvals and low
noise operations, the converters respond extremely fast to change in load
conditions. Inherent in the design are very well-controlled output voltages and minimal need for minimum loading on main (V1) output.
IHB60T48XX Series 3348 75VDC
Reflected Ripple Current Peak - Peak220mA
Input Ripple Rejection DC to 1KHz5060dB
Maximum Input CurrentOutput Power = 60W
IHB60T24XX SeriesV
IHB60T48XX SeriesV
INPUT
No Load Power DissipationP
Inrush Charge
IHB60T24XX Series0.29mC
IHB60T48XX Series0.165mC
Quiescent Operating Current
Primary On/Off Disabled7.510mA
Secondary On/Off Disabled1525mA
PARAMETERCONDITIONSMINTYPMAXUNITS
ISOLATION
Input to OutputPeak Test1500V
Input to Baseplate1500VDC
Channel to ChannelAny Channel to Any Channel500VDC
Resistance, Input - Output10MΩ
Capacitance, Input - Output2000pF
Leakage CurrentV
GENERAL
Set Point AccuracyV
Turn-on TimeWithin 1% of Nominal V
Remote On/Off Control Inputs
PrimaryOpen Collector/Drain
Sink Current-Logic LowV
Vlow0.8V
VhighOpen Collector
SecondaryOpen Collector/Drain
Sink Current-Logic Low100µA
Vlow0.4V
VhighOpen Collector
* See Application Notes available on the web at www.cdpowerelectronics.com
**X = Either 24 or 48
Product: www.cdpowerelectronics.com
IHB60T REV A 10/01
2
Page 3
SPECIFICATIONS, ALL MODELS
Specifications are at T
PARAMETERCONDITIONS
Output PowerTotal Combined O/P Power =
Set Point VoltageI
Output Current, I
Output Ripple, p-pDC to 20MHz
Output Adjust RangeSee Application Notes
Output Temperature Drift.02.05.02.05.02.05%/°C
Line RegulationV
Load RegulationMin Load to Rated Load0.501.0%
Current Limit InceptionOther Outputs Min Load234.04.0A
Short-Circuit Current19253.24.03.24.0A
Transient Response50 to 100% Load Step
Peak Deviation150250mV
Settling TimeV
Overvoltage Limit4.25.0V
IHB60TX0315** OUTPUT
EfficiencyI
= +40°C nominal input voltage unless otherwise specified.
CASE
V1V2 V3UNITS
MinN o mMaxMin N om MaxMinNomMax
60 Watts Max.306015301530W
3.315.8515.85V
0.5918012012A
OUT
O Nom
*100200125250125250mV
*3.153.80 Dependent on V1V
IN, Min≤VIN≤VIN, Max
OUT1
, 1% of V
OUT
=9A, (I
F.L. V
IO = I
OUT2+IOUT3
=Nominal
IN
O, Nom
OUT, Nom
)=2A8586%
0.051.01.02.01.02.0%
3550µSec
See Regulation Curves See Regulation Curves
PARAMETERCONDITIONS
V1V2 V3UNI TS
MinNomMaxMin Nom MaxMinNomMax
Output PowerTotal Combind O/P Power =
60 Watts Max306015301530W
Set Point VoltageI
Output Current, I
Output Ripple, p-pDC to 20MHz
OUT
Output Adjust Range
O Nom
*4.755.50 Dependent on V1V
*125200150250150250mV
5.11212V
0.56.01201.252.501.252.5A
Output Temperature Drift.02.05.02.05.02.05%/°C
Line RegulationV
Load RegulationMin Load to Rated Load0.501.0%
IN, Min≤VIN≤VIN, Max
IO = I
O, Nom
0.050.101.02.01.02.0%
See Regulation Curves
See Regulation Curves
Current Limit InceptionOther Outputs Min Load165.05.0A
Short-Circuit Current12.6164.05.04.05.0A
Transient Response50 to 100% Load Step
Peak Deviation200300mV
Settling TimeV
Overvoltage Limit6.06.8V
IHB60TX0512** OUTPUT
EfficiencyI
PARAMETERCONDITIONS
OUT1
, 1% of V
OUT
=6A, (I
F.L. V
OUT, Nom
)=2.5A8687%
OUT2+IOUT3
=Nominal
IN
3550µSec
V1V2 V3UNITS
MinNomMaxMin Nom MaxMinNomMax
Output PowerTotal Combined O/P Power =
60 Watts Max306015301530W
Set Point VoltageI
Output Current, I
Output Ripple, p-pDC to 20MHz
OUT
Output Adjust Range
O Nom
*4.605.50 Dependent on V1V
*100200125250125250mV
5.015.315.3V
0.5612012012A
Output Temperature Drift.02.05.02.05.02.05%/°C
Line RegulationV
Load RegulationMin Load to Rated Load0.501.0%
Current Limit InceptionOther Outputs Min Load164.04.0A
IN, Min≤VIN≤VIN, Max
IO = I
O, Nom
0.050.101.02.01.02.0%
See Regulation CurvesSee Regulation Curves
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific model ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal resistance molding
compound which has excellent chemical resistance and electrical
properties in high humidity environments and over a wide operating
temperature range. The encapsulant and outer shell of the unit have
UL94V-0 ratings. Lead material is solder plated to allow ease of
solderability.
C&D Technologies (Power Electronics) Ltd.
Shannon, Co. Clare, Ireland
T el: +353.61.474.133 Fax:+353.61.474.141
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to
be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from
any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and
in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace
applications.
Product: www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.770.9369
IHB60T REV A 10/01
C&D Technologies, (NCL)
Milton Keynes MK14 5BU UK
T el: +44 (0)1908 615232 Fax: +44 (0)1908 617545
4