Datalogic Scanning Jet User Manual

Datalogic Jet™
User’s Manual
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy
Datalogic Jet™ - User's Manual
Ed.: 11/2007
ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies.
© Datalogic Mobile S.r.l. 2004-2007

CONTENTS

REFERENCES ............................................................................................. v
Conventions .................................................................................................. v
Reference Documentation ............................................................................ v
Services and Support.................................................................................... v
SAFETY REGULATIONS............................................................................ vi
General Safety Rules....................................................................................vi
Bluetooth® Approval......................................................................................vi
Power Supply................................................................................................vi
Laser Safety.................................................................................................vii
Radio Compliance......................................................................................... x
FCC Compliance..........................................................................................xii
SAR Compliance..........................................................................................xii
WEEE Compliance .....................................................................................xiii
GENERAL VIEW ........................................................................................ xv
1
1.1
1.2
1.3
1.4
1.5
1.6
2
2.1
2.1.1 RS232/USB Direct Connection .....................................................................7
2.1.2 WLAN Connection ........................................................................................ 8
2.1.3 WPAN Connection ...................................................................................... 10
2.1.4 WWAN Connection ..................................................................................... 12
2.2
INTRODUCTION .......................................................................................... 1
Datalogic Jet™ PDA Description ..................................................................1
Available Models...........................................................................................2
Package Contents......................................................................................... 2
Inserting Mini SD Card..................................................................................3
Accessories...................................................................................................5
Operating System .........................................................................................6
CONNECTIONS ........................................................................................... 7
PDA Connection to the Host Computer ........................................................7
Connection Cables...................................................................................... 17
3
3.1
3.2
3.3
3.3.1 Laser Data Capture..................................................................................... 21
3.3.2 Imager Data Capture .................................................................................. 22
3.3.3 RFID Data Capture ..................................................................................... 23
3.4
3.4.1 System Control and Navigation Keys.......................................................... 24
3.4.2 Resetting the Jet......................................................................................... 28
USE AND FUNCTIONING.......................................................................... 18
PDA Startup................................................................................................ 18
Using the Stylus .......................................................................................... 19
Data Capture............................................................................................... 21
Description of the Keys ............................................................................... 24
iii
3.4.3 Key Selection.............................................................................................. 25
3.5
Status Indicators .........................................................................................31
3.5.1 LED Status.................................................................................................. 31
3.5.2 Taskbar....................................................................................................... 32
3.6
Data Capture Configuration ........................................................................34
3.6.1 Configure .................................................................................................... 34
3.6.2 Capture ....................................................................................................... 40
3.7
Control Panel ..............................................................................................41
3.7.1 Buttons........................................................................................................ 42
3.7.2 Registry....................................................................................................... 44
3.7.3 Files Admin ................................................................................................. 45
3.7.4 Wireless Communications........................................................................... 48
3.7.5 Ethernet Settings ........................................................................................ 50
3.7.6 Volume Settings.......................................................................................... 53
3.8
Windows Connections ................................................................................ 57
3.8.1 Microsoft® ActiveSync® ............................................................................. 57
3.8.2 Bluetooth® Manager Device Setup............................................................. 59
3.8.3 FTP Server Setup .......................................................................................68
3.9
Backup Directory File Management ............................................................ 69
4
4.1
4.2
4.3
5
5.1
5.2
MAINTENANCE .........................................................................................70
Charging the Battery Pack .......................................................................... 70
Replacing the Battery Pack.........................................................................72
Cleaning the PDA .......................................................................................75
TECHNICAL FEATURES........................................................................... 76
Technical Data ............................................................................................ 76
Reading Diagrams ......................................................................................79
6
iv
TEST CODES............................................................................................. 80
GLOSSARY................................................................................................ 83
INDEX......................................................................................................... 86

REFERENCES

CONVENTIONS

This manual uses the following conventions:
“User” refers to anyone using a Datalogic Jet™ PDA. “PDA” and " “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Datalogic Jet™ PDA.

REFERENCE DOCUMENTATION

For further information regarding

SERVICES AND SUPPORT

Datalogic provides several services as well as technical support through its website. Log on to www.mobile.datalogic.com and click on the information including:
-
PRODUCTS
Search through the links to arrive at your product page where you can download specific
Datalogic Jet™" refer to Datalogic Jet™ PDA.
Datalogic Jet™ refer to the SDK Help on-Line.
links indicated for further
Manuals and Software & Utilities
-
SERVICES & SUPPORT
-
Datalogic Services Warranty Extensions and Maintenance Agreements
-
Authorised Repair Centres
-
CONTACT US
E-mail form and listing of Datalogic Subsidiaries
v

SAFETY REGULATIONS

Read this manual carefully before performing any type of connection to the Datalogic Jet™ PDA. The user is responsible for any damages caused by incorrect use of
NOTE

GENERAL SAFETY RULES

Use only the components supplied by the manufacturer for the specific Datalogic Jet™ PDA being used.
Do not attempt to disassemble the Datalogic Jet™ PDA, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty.
When replacing the battery pack or at the end of the operative life of the Datalogic Jet™ PDA, disposal must be performed in compliance with the laws in force. See also par. 4.2.
Do not submerge the Datalogic Jet™ PDA in liquid products.

BLUETOOTH® APPROVAL

This product is equipped with the following certified Bluetooth module:
Product Name: Datalogic CE BLUETOOTH SUBSYSTEM
Bluetooth ID
Product ID

POWER SUPPLY

This device is intended to be supplied by a UL Listed/CSA Certified Power Unit marked "Class 2" or LPS power source rated 12-14 V DC, minimum 1 A which supplies power directly to the PDA.
the equipment or by inobservance of the indication supplied in this manual.
: B03071
: DLBTCE-02
vi

LASER SAFETY

The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both Laser models and the Datalogic Jet™ Imager Aiming System.
Laser output window
I D F E
La luce laser è visibile all'occhio umano e viene emessa dalla finestra indicata nella figura.
LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MINIMA POTENZA DI USCITA: LUNGHEZZA D'ONDA EMESSA: CONFORME A EN 60825-1 (2001)
AVOID EXPOSURE
LASER LIGHT
IS EMITTED FROM
THIS APERTURE
CAUTION-CLASS 2 LASER LIGHT WHEN OPEN - DO NOT STARE INTO BEAM
Die Laserstrahlung ist für das menschliche Auge sichtbar und wird am Strahlaustrittsfenster ausgesendet (siehe Bild).
LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG: WELLENLÄNGE: ENTSPR. EN 60825-1 (2001)
Le rayon laser est visible à l'œil nu et il est émis par la fenêtre désignée sur l'illustration dans la figure.
RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 PUISSANCE DE SORTIE: LONGUER D'ONDE EMISE: CONFORME A EN 60825-1 (2001)
This product complies wit h
21 CFR Subchapter J
LASER LIGHT - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1.4 mW
EMITTED WAVELENGTH 630~680 nm
EN60825-1:2001
La luz láser es visible al ojo humano y es emitida por la ventana indicada en la figura.
RAYO LÁSER NO MIRAR FIJO EL RAYO APARATO LÁSER DE CLASE 2 MÁXIMA POTENCIA DE SALIDA: LONGITUD DE ONDA EMITIDA: CONFORME A EN 60825-1 (2001)
vii
ENGLISH
The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your PDA.
STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous
WARNING
visible laser light.
The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
ITALIANO
Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e si riferiscono all’uso corretto del PDA.
NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 e EN 60825-1. Non si rende mai necessario aprire l’apparecchio per motivi di installazione, utilizzo o manutenzione.
L'utilizzo di procedure o regolazioni differenti da quelle descritte nella documentazione può provocare un'esposizione pericolosa
ATTENZIONE
a luce laser visibile.
Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dall’occhio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore, anche attraverso superfici riflettenti come gli specchi.
viii
DEUTSCH
Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom PDA.
NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs­Arbeiten zu öffnen.
Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, können ein
ACHTUNG
gefährliches Laserlicht verursachen.
Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschäden von kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden für längere Zeit in den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflächen zu richten.
FRANÇAIS
Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se réfèrent à une correcte utilisation du PDA.
NORMES DE SECURITE LASER Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de fabrication: CDRH 21 CFR 1040 et EN 60825-1. Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou l’entretien.
L'utilisation de procédures ou réglages différents de ceux donnés ici peut entraîner une dangereuse exposition à lumière laser
ATTENTION
visible.
Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été constaté à la suite d’une exposition au rayon laser. Eviter de regarder fixement le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi de diriger le rayon vers les yeux d’un observateur, même à travers des surfaces réfléchissantes (miroirs, par exemple).
ix
ESPAÑOL
Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del PDA.
NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una
ATENCIÓN
exposición peligrosa a la luz láser visible.
El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duración. Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa, por ejemplo el sol. Además, eviten de dirigir el rayo láser hacia los ojos de un observador, también a través de superficies reflectantes como los espejos.
LED Illuminator
The use of an illuminator in the Datalogic Jet™ Imager is a Class 1 LED product:
CLASS 1 LED PRODUCT ILLUMINATORE LED CLASSE 1 AUSLEUCHTER LED KLASSE 1 ILLUMINATEUR A LED DE CLASSE 1 ILUMINADOR LED DE CLASE 1

RADIO COMPLIANCE

In radio systems configured with PDAs and access points, the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place. Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country.
The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings.
x
The following shows the correspondence between the Datalogic Jet™ models and the Radio modules:
DLBJET™ 5XX-XXX-XXX 802.11b (Wi-Fi) radio card DLBJET ™ 7XX-XXX-XXX 802.11b/g (Wi-Fi) radio card DLBJET ™ X1X-XXX-XXX GSM/GPRS Tri-band (900, 1800, 1900 MHz) module
Information for the User
ENGLISH
Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required. Refer to the web site information.
Contatta l'autorità competente per la gestione degli apparati a radio frequenza del tuo paese, per verificare disponibili sul sito:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm.
Contactez l'autorité compétente en la gestion des appareils à radio fréquence de votre pays pour vérifier renseignement vous pouvez vous adresser au site web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm.
Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres Landes, um zu prüfen ob es Einschränkungen gibt, oder eine Lizenz erforderlich ist. Weitere Informationen finden Sie auf der Web Seite:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm.
Contacta la autoridad competente para la gestión de los dispositivos de radio frecuencia de tu país, para verificar cualesquiera restricciones o licencias posibles requerida. Además se puede encontrar mas información en el sitio web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm.
http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further
ITALIANO
eventuali restrizioni o licenze
FRANÇAIS
d'éventuelles restrictions ou licences
DEUTSCH
ESPAÑOL
. Ulteriori informazioni sono
. Pour tout
xi

FCC COMPLIANCE

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
FCC ID U4G0019. All DLBJET™ 5XX-XXX-XXX Wi-Fi models contain FCC ID H9PLA4137. All DLBJET™ 7XX-XXX-XXX Wi-Fi models contain FCC ID TWG-SDCCF10G. All DLBJET™ GSM models contain FCC ID QIPMC55. All DLBJET™ RFID models contain FCC ID U4G0023.

SAR COMPLIANCE

This product has been tested and found to comply with the following standards:
- EN50360: product standard to demonstrate the compliance of mobile phones with the
basic restrictions related to human exposure to electromagnetic fields (300 MHz – 3 GHz).
- EN50361: basic standard for the measurement of specific absorption rate related to
human exposure to electromagnetic fields from mobile phones (300 MHz – 3 GHz).
- OET BULLETIN 65 SUPPLEMENT C: evaluating compliance with FCC guidelines
for human exposure to radio frequency electromagnetic fields.
- Australian Radiation Protection And Nuclear Safety Agency (ARPANSA): radiation
protection series publication No. 3: maximum exposure levels to radio frequency fields 3 KHz TO 300 GHz.
xii

WEEE COMPLIANCE

Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC
L’apparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani.
Smaltire l’apparecchiatura in conformità alla presente Direttiva consente di:
evitare possibili conseguenze negative per l’ambiente e per la salute umana che
potrebbero invece essere causati dall’errato smaltimento dello stesso;
recuperare materiali di cui è composto al fine di ottenere un importante risparmio di
energia e di risorse.
Per maggiori dettagli sulle modalità di smaltimento, contattare il Fornitore dal quale è stata acquistata l’apparecchiatura o consultare la sezione dedicata sul sito www.mobile.datalogic.com.
Information for the user in accordance with the European Commission Directive 2002/96/EC
At the end of its useful life, the product marked with the crossed out wheeled wastebin must be disposed of separately from urban waste.
Disposing of the product according to this Directive:
avoids potentially negative consequences to the environment and human health
which otherwise could be caused by incorrect disposal
enables the recovery of materials to obtain a significant savings of energy and
resources.
For more detailed information about disposal, contact the supplier that provided you with the product in question or consult the dedicated section at the website www.mobile.datalogic.com.
Information aux utilisateurs concernant la Directive Européenne 2002/96/EC
Au terme de sa vie utile, le produit qui porte le symbole d'un caisson à ordures barré ne doit pas être éliminé avec les déchets urbains.
Éliminer ce produit selon cette Directive permet de:
xiii
éviter les retombées négatives pour l'environnement et la santé dérivant d'une
élimination incorrecte
récupérer les matériaux dans le but d'une économie importante en termes d'énergie
Pour obtenir des informations complémentaires concernant l'élimination, veuillez contacter le fournisseur auprès duquel vous avez acheté le produit ou consulter la section consacrée au site Web www.mobile.datalogic.com.
Información para el usuario de accuerdo con la Directiva Europea 2002/96/CE
Al final de su vida útil, el producto marcado con un simbolo de contenedor de bassura móvil tachado no debe eliminarse junto a los desechos urbanos.
Eliminar este producto de accuerdo con la Directiva permite de:
Para obtener una información más detallada sobre la eliminación, por favor, póngase en contacto con el proveedor donde lo compró o consultar la sección dedicada en el Web site www.mobile.datalogic.com.
Benutzerinformation bezüglich Richtlinie 2002/96/EC der europäischen Kommission
Am Ende des Gerätelebenszyklus darf das Produkt nicht über den städtischen Hausmüll entsorgt werden. Eine entsprechende Mülltrennung ist erforderlich.
Beseitigung des Produkts entsprechend der Richtlinie:
Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten über den sie das Produkt erworben haben, oder besuchen sie unsere Hompage unter www.mobile.datalogic.com.
et de ressources
evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas
de una eliminación inadecuada
recuperar los materiales obteniendo así un ahorro importante de energía y recursos
verhindert negative Auswirkungen für die Umwelt und die Gesundheit der Menschen ermöglicht die Wiederverwendung der Materialien und spart somit Energie und
Resourcen
xiv

GENERAL VIEW

J
A
B
I
C
D
E
H
G
F
Figure A – General View
A) Data capture/Laser output window B) Scan key(s) (3) C) Bluetooth®
LED D) Charging status LED E) Backlit keyboard F) External power supply connector G) Communication/Charger connector H) Headset jack
P
O
N
M
L
I) User programmable LED J) Backlit display K) Mini SD card SLOT L) Microphone M) Latch release button N) Battery latch O) Battery pack P) Speaker
K
xv
xvi

INTRODUCTION

1
1 INTRODUCTION
1.1 DATALOGIC JET™ PDA DESCRIPTION
The Datalogic Jet™, is the powerful Datalogic PDA. Thanks to the state-of the-art architecture and the most advanced technologies, it can provide the most suitable levels for capturing, computing and communicating data faster and easier.
In addition to the highest robustness and reliability in its class, other key features of the Datalogic Jet™ include fully integrated automatic data capture (barcodes, RFID tags and images) and superior wireless communication capabilities (WLAN, WWAN and WPAN). The PDA is equipped with a function-based keyboard for direct ERP transactions and with a web-based layout for HTML needs as well. These key requirements make the Datalogic JET perfect for use in field force automation, in­store and logistics applications.
The Datalogic Jet™ enables companies and organizations worldwide to make more effective use of people and tools for receiving, storage, and shipping activities. For example, extended mobility allows simultaneous real-time inventory management and control of all stock movements to increase precision while minimizing operating costs. Data on store shelves, inventory levels and storage bins are immediately available to permit greater coordination and cut flow times.
The Datalogic Jet™ provides mobile professionals with the most relevant features needed to operate in demanding environments: reliability, ruggedness, drop resistance, long lasting batteries, flexible communication and efficient data capture. To optimize mobile applications, a user-accessible memory slot is also present to backup data, extend databases, etc.
Thanks to a set of accessories, such as a vehicle cradle (standard and loud speaker), cigarette lighter power adapter, dashboard mounting kit, with state-of-the­art technology inside the PDA, the Datalogic Jet is the right answer for all data management needs on the move.
1
1
DATALOGIC JET™
1.2 AVAILABLE MODELS
The Datalogic Jet™ PDA is available in different models depending on the options it is equipped with. All options are listed below:
communication options: Wi-Fi 802.11b, Wi-Fi 802.11b/g, GSM/GPRS, Bluetooth®
capture options: laser, imager, laser + RFID
compute options
For further details about the Datalogic Jet™ PDA models refer to the web site: www.mobile.datalogic.com.
(fixed)
: O.S. version, microprocessor type/speed, memory size
1.3 PACKAGE CONTENTS
The Datalogic Jet™ PDA package contains:
1 Datalogic Jet™ PDA
1 CD-ROM Datalogic SDK
1 CD-ROM Getting Started Disk only for Windows Mobile
2 styluses
3 adhesive pull tabs for Mini SD card
1 user’s manual
1 rechargeable battery pack
1 adjustable elastic strap with stylus holder
1 belt clip
1 belt clip pivot
Any other packages will contain the accessories necessary for the Datalogic Jet™ PDA connection to the host computer and to the network: the cradle, power supply, and one or more connection cables. Remove all the components from their packaging; check their integrity and congruity with the packing documents.
CAUTION
NOTE
2
Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty.
Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See paragraph 4.1.
INTRODUCTION
1
1.4 INSERTING MINI SD CARD
With Datalogic Jet™ PDA, it is possible to add a Mini SD Card for
storage capacity.
Datalogic Jet (see Figure A) and then proceed as follows:
1. Before inserting the Mini SD card, peel the adhesive pull tab and stick it onto to
the Mini SD card as shown in the picture below:
To access the Mini SD card slot, unscrew the cover at the side of
additional
2. Open the Mini SD card slot by unscrewing the two screws:
3. Insert the card with the written part upward and push it until it clicks into place:
To remove the Mini SD card slightly push it toward the inside until it clicks; the card is released, pull it out using the adhesive pull tab.
3
1
CAUTION
DATALOGIC JET™
Follow proper ESD precautions to avoid damaging the SD. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded.
Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the SD card slot for any other accessories.
4
INTRODUCTION
1.5 ACCESSORIES
Cradles
94A151096 Datalogic Jet™ Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB communications)
94A151097 Jet™ Vehicle Cradle Loudspeaker 94A151100 Jet™ Vehicle Cradle Standard
Charger
94A151098 Datalogic Jet™ Multi-Battery pack Charger (4 slots)
Batteries
94ACC1293 Datalogic Jet™ Standard Battery pack (Li-Ion battery pack 1070 mAh@7.4 V) 94ACC1294 Datalogic Jet™ Large Capacity Battery pack (Li-Ion battery pack 1800
mAh@7.4 V)
Power Supply
94ACC1286 PG12-10P35 AC/DC Power Supply without cord for Datalogic Jet™ 94ACC1296 PG12-10P35 AC/DC Power supply EU KIT 94ACC1297 PG12-10P35 AC/DC Power supply UK KIT 94ACC1298 PG12-10P35 AC/DC Power supply US KIT 94ACC1299 PG12-10P35 AC/DC Power supply AUS KIT
94ACC4595 FPS18 Power Supply without cord for Datalogic Jet™ Single Cradle Desk and for Datalogic Jet™ Multi-Battery Charger
94ACC1150 Power cord EU 3-pin
Cables
94A051008 WIN-NET SERIAL CABLE (HRS 3500-16P-CV) cable for RS232 direct connection between the PDA and the PC
94A051009 WIN-NET USB CABLE (HRS 3500-16P-CV) cable for USB direct connection between the PDA and the PC
94A051012 WIN-NET VEHICLE PWR CAB (HRS 3500-16P-CV) cable for powering Datalogic Jet™ from the car cigarette lighter
Various
94ACC1331 vo-CE® Headset 94ACC1333 vo-CE® Headset Adapter For Datalogic Jet™ 94ACC1287 Datalogic Jet™ Belt Holster 94ACC1288 Datalogic Jet™ Functional Case 94ACC1307 Datalogic Jet™ Functional Case Plus 94ACC1300 Datalogic Jet™ Backstrap Kit (2 pcs) 94ACC1308 Safe Shoulderstrap (5 pcs) 94ACC1301 Stylus Pen (20 pcs)
1
5
1
DATALOGIC JET™
Use only a Datalogic Mobile-approved power supply and cables. Use of an alternative power supply will invalidate any approval given to
NOTE
this device and may be dangerous.
1.6 OPERATING SYSTEM
Datalogic Jet™ comes in two different models, respectively supporting Windows CE and Windows Mobile. For further information regarding Windows Mobile refer to the website: http://www.microsoft.com/windowsmobile.
6

CONNECTIONS

2
2 CONNECTIONS
2.1 PDA CONNECTION TO THE HOST COMPUTER

2.1.1 RS232/USB Direct Connection

You can use a cable to connect the Datalogic Jet™ PDA to a host computer to transfer data.
Key:
A Host computer C RS232 cable or USB cable B Datalogic Jet™ PDA D *Power Supply
* Recommended Power Supply: PG12-10P35 AC/DC Power Supply
If the PDA supports Windows Mobile, before plugging the RS232 cable you have to check the 'COM1 Enable' option on the 'System Configuration' window. (Start -> Programs -> System
CAUTION
CAUTION
Configuration).
USB communication may not be completely guaranteed while batteries are simultaneously in charge. Avoid the power supply connection when the USB link is active.
(only necessary for battery charging)
7
2
DATALOGIC JET™
2.1.2 WLAN Connection
Datalogic Jet™ Wi-Fi 802.11b and Wi-Fi 802.11b/g the host using the on-board radio frequency module and an Access Point connected to the host computer.
For models using the WiFi7 radio (7xx-xxx-xxx models), you can find information about the applet for radio configuration:
http://www.summitdatacom.com/SCU.htm.
To launch this utility you can tap the specific icon if it’s visible on the taskbar or:
1. On Windows CE device, you can open Connections folder or Control Panel from
desktop and select the ‘Summit Client Utility’ icon.
2. On Windows Mobile device, you can select the menu item: Start->Programs-
>Summit and tap the ‘Summit Client Utility’ icon.
A
B
1
models can communicate with
C
Key: A) Datalogic Jet™ PDA B) Access point C) Host – Application Server
1
Note: unless otherwise specified, the Wi-Fi term is used both for the 802.11b and the 802.11b/g cards.
8
CONNECTIONS
Wi-Fi module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communications applet (see par. 3.7.4). To start configuring your WLAN connection, tap the Wi-Fi icon at the
NOTE
bottom of the screen.
NOTE
NOTE
2
Suspending the terminal powers off the 802.11b/g radio and drops the radio connection. When the terminal resumes, depending on the radio power mode and security protocol selected, it takes approximately from 10 to 30 seconds for the 802.11b/g radio driver to re-associate the radio to the network.
Area coverage and radio performance may vary, due to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.)
9
2
2.1.3 WPAN Connection
Datalogic Jet™ PDAs can communicate with a Bluetooth within a range of 10 m, using the on-board Bluetooth
®
module.
DATALOGIC JET™
®
device, such as a printer,
A
B
Key: A) Datalogic Jet™ PDA B) Bluetooth® printer
In order to avoid wasting energy, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par.
NOTE
3.7.4), and perform the Discovery procedure (see par. 3.8.2).
The Blue LED flashing signals that the Bluetooth® module is on.
Suspending the terminal powers off the Bluetooth radio and drops the piconet (Bluetooth connection). When the terminal resumes, it takes approximately 10 seconds for the Bluetooth radio driver to re-
NOTE
initialize the radio.
10
CONNECTIONS
NOTE
2
Area coverage and Bluetooth radio performance may vary, due to environmental conditions or interference caused by other devices (microwave ovens, radio transmitters, etc.), etc.
11
2
DATALOGIC JET™
2.1.4 WWAN Connection
Datalogic Jet™ GSM/GPRS models enhance your connectivity solutions giving you an opening to an international wireless infrastructure that is the standard in Europe and Asia.
GSM (Global System for Mobile communications) is a digital mobile phone system based on TDMA; it utilizes the 900, 1800 and 1900 MHz bands. GPRS supports IP (Internet Protocol) and allows accessing Internet and Intranet services, such as sending and receiving e-mail or Web browsing.
In order to use a WWAN Connection you have to install a SIM Card (see instructions on the following page).
In order to avoid wasting energy, the GSM/GPRS module is off by default. If you need to have GSM/GPRS working, the module must be powered on using the Wireless Communications applet
NOTE
NOTE
NOTE
(see par. 3.7.4).
Suspending the terminal powers off the GSM/GPRS radio and drops the connection. When the terminal resumes, if the connection was managed by Microsoft Internet Explorer, it is automatically restored, otherwise, the radio connection must be manually re-initialized.
The GSM voice capability of this mobile computer has to be addressed to occasional use, in well covered areas. If the coverage is poor, the voice quality can be highly affected. In case of vehicle cradle installations, a good habit is to install the external microphone to minimize the risk of noises and echoes. If the coverage is poor, in case of continuous communication, some degradation of the barcode reading capabilities can be experienced.
12
CONNECTIONS
2
13
2
DATALOGIC JET™
Installing the SIM Card
To correctly insert the SIM Card, proceed as follows:
1- Turn off the Datalogic Jet™ PDA.
2- Press the latch release button and pull the battery latch down as indicated in the
figures below:
3- Remove the battery pack to have access to the SIM card slot:
SIM Card Slot
Locking Plate
14
CONNECTIONS
4- Open the Sim Card slot by pulling up the locking plate.
2
5- Pull up the cardholder and insert the Sim Card with its contacts downward and
its round corner at the bottom.
6- Lock the card into place by pushing the cardholder down and then pulling the
locking plate down.
15
2
DATALOGIC JET™
Follow proper ESD precautions to avoid damaging the SIM card. Proper ESD precautions include, but are not limited to, working on an
CAUTION
ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the SIM card slot for any other accessories.
Removing the SIM Card
To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slot.
All the basic functionalities normally associated to the SIM card are managed by the terminal (GPRS connectivity, phone calls, SMS handling).
NOTE
It is possible that not all the services connected to the SIM card can be used or can be managed by the terminal.
16
CONNECTIONS
2.2 CONNECTION CABLES
The following cables are listed with their order number.
RS232 Direct Connection: 94A051008 WIN-NET SERIAL CABLE (HRS 3500-16P-CV)
USB Direct Connection: 94A051009 WIN-NET USB CABLE (HRS 3500-16P-CV)
Power Supply Polarity:
Datalogic Jet™ side
16-pin
5
6 2
7
8
9
11
10
13
Datalogic Jet™ side
16-pin
13
14 15
16
HOST/PC side
RX
TX
CTS
RTS
DSR
DTR
GND
GND
V+
D+
D-
VEXT
9-pin (female)
3
7
8
4
1
6
5
HOST/PC side
9-pin (female)
2
4
1
3
2
GND
17
3
Y
DATALOGIC JET™
3 USE AND FUNCTIONING
The use of the Datalogic Jet™ PDA depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc.
3.1 PDA STARTUP
The Datalogic Jet™ PDA turns on when the battery pack or the external supply is inserted.
After the battery pack is installed, use the [ON/OFF] key to turn the PDA on and off.
As soon as the PDA is on, the Windows CE/ Windows Mobile desktop configuration will appear on the screen. Wait a few seconds before starting any activity so that the PDA completes its startup procedure.
START MENU
LEFT SOFT
KEY
Windows CE Desktop Windows MobileToday Screen
LEFT SOFT KE
Use the stylus as suggested in paragraph 3.2 to select icons and options.
For the use of Left and Right Soft Keys, refer to par. 3.7.1.
18
RIGHT
SOFT
KEY
USE AND FUNCTIONING
3
When it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel, the PDA goes into power-off (low power with display and keyboard backlight off). In this mode it can be awakened (resuming operation) by the [ON/OFF] key.
The PDA can also be awakened or turned off by the application program.
NOTE
3.2 USING THE STYLUS
The stylus selects items and enters information. The stylus functions like a mouse.
Tap:
Double Tap:
Touch the screen once with the stylus to open items and select options (Windows Mobile only).
Touch the screen twice with the stylus to open items and select options (Windows CE only).
Drag:
Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items.
Tap and hold the stylus on an item to see a list of actions
Tap-and-hold:
available for that item. On the pop-up menu that appears, tap the action you want to perform.
The stylus is factory aligned; however, it is possible to align the cursor on the screen with the tip of the stylus. Enter the STYLUS applet of the Control Panel and tap the center of each target that appears on the screen with the tip of the stylus.
19
3
CAUTION
DATALOGIC JET™
Use only original Datalogic styluses supplied with the product itself.
In harsh applications, use of screen protectors should be taken into consideration, in order to extend the touch screen operating life.
To prevent damage to the screen, do not use sharp devices or any device other than the Datalogic Mobile-provided stylus.
Do not apply not necessary high pressures on the screen.
For applications where an intensive use of the touch screen is foreseen, please consider that touch screen components are subject to progressive wear.
20
USE AND FUNCTIONING
3
3.3 DATA CAPTURE
To capture data, first of all select the barcode icon on the bottom-right side of the display and tap the 'Capture' menu item, then proceed with the following directions.
To configure and enable data capture parameters refer to par. 3.6.

3.3.1 Laser Data Capture

To scan barcodes, point the Datalogic Jet™ PDA laser model onto the code from a distance within the reading range while pressing one of the three SCAN Keys. See the reading diagrams in par. 5.2 for the reading range of your model.
The lighted band emitted by the laser must completely intercept the barcode as shown in the figure below. If enabled, the emission of an acoustic signal will indicate that the scan has taken place correctly.
21
3
DATALOGIC JET™

3.3.2 Imager Data Capture

To read a 1D or 2D code, simply point the Datalogic Jet™ Imager model onto the code from a distance within the reading range (see par. 5.1, section Datalogic Jet™ Imager Optical Features) and press one of the three SCAN Keys.
The Datalogic Jet™ Imager uses an intelligent aiming system pattern, similar to those on cameras, indicating the field of view, which should be positioned over the code:
Aiming System
If the aiming system pattern is centered over the entire symbology as shown in the following figure, either wait for the timeout or release the Scan key to capture the image.
A red beam illuminates the code, which is captured and decoded. You will get a good read.
22
USE AND FUNCTIONING
3
Linear barcode 2D Matrix symbol
ÌBX3ÉÎ
Relative Size and Location of Aiming System Pattern
The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the Datalogic Jet™ Imager is closer to the code and larger when it is farther from the code.
Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. 5.1 for further details).

3.3.3 RFID Data Capture

To read or write a tag, place the Datalogic Jet™ PDA so that the RFID emission window is in front of and almost in contact with the tag, then press one of the three SCAN Keys or the application-defined key.
23
3
DATALOGIC JET™
3.4 DESCRIPTION OF THE KEYS
The Datalogic Jet™ PDA provides a function-oriented keyboard having a total of 27 keys. The keyboard can be divided as follows:
2 Lateral SCAN keys (1 per side)
System Control
and Navigation
Keys
Power Key
General keys

3.4.1 System Control and Navigation Keys

Powers the PDA ON or OFF.
24
They let you move forwards or backwards within the Internet Explorer browser pages.
They let you move forwards, backwards, upwards or downwards within Text fields, scroll through a Menu list or browse among folder files.
Switches on/off the keyboard backlight. The backlight automatically turns off after a set timeout.
USE AND FUNCTIONING
3.4.2 Key Selection
The following figure shows the Datalogic Jet™ PDA keyboard:
3
25
3
DATALOGIC JET™
Some of these keys carry extra symbols and are logically divided in up to 3 sections according to the following figure:
A
B
C
Each section corresponds to a symbol that can be obtained using the corresponding keyboard method according to the following scheme:
A) function of the key when simultaneously pressed along with the Orange key; B) function of the key when directly pressed; C) function of the key when in Alpha mode, in order to digit all the alphabetic
characters positioned over the keys.
It starts Data capture.
The ORANGE key pressed simultaneously along with any other keyboard key enables the character positioned above or at its right/left side (in case of keys displayed at the top of keyboard).
Ex: ORANGE key + [
5
jkl] key corresponds to the
character.
When in alphanumeric mode, by pressing repeatedly the key, you can scroll through a list of punctuation signs and symbols and select the desired one by a timeout.
It enters a special mode through which it is possible to digit all the alphabetic characters positioned over the keys. Ex: [7pqrs] in alphanumeric mode: press once for ‘p’, twice for ‘q’, three times for ‘r’, four times for ‘s’. To exit the Alpha mode and return to the keyboard normal functioning it is necessary to press the Alpha key again.
26
It locks and unlocks the Keyboard.
It corresponds to pressing ALT-F on a standard PC running Windows that is it opens the first entry of a drop-down Menu.
USE AND FUNCTIONING
Once the Alpha mode has been entered, press the Alpha key again to exit this mode.
NOTE
3
Switches on/off the keyboard backlight. Both display and keyboard backlight automatically turn off after a timeout, depending on Control Panel settings. The backlights automatically turn off after a set timeout.
27
3
DATALOGIC JET™

3.4.3 Resetting the Jet

Windows CE
There are several reset methods for the Jet. A warm boot terminates an unresponsive application and clears the working RAM, but preserves both the file system and the registry. A cold boot forces all applications to close and clears the working RAM and the files not resident on the persistent flash memory. Registry is restored from persistent memory if available or returned to factory default. A Clean Boot restores the Jet to factory configuration: both the registry and the file system return to factory default.
Warm Boot
A warm boot closes all applications and clears the working RAM, but preserves both the file system and the registry. If an application hangs, initiate a warm boot to terminate the application. To perform a warm boot, press the following keys simultaneously:
Cold Boot
A cold boot is a complete reset of the Jet in which all applications are forcibly closed and the RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see 3.7.2) and RAM file system is completely erased. You will lose any applications and data (included registry) which are not stored in persistent flash memory. A cold boot is necessary when the Windows CE operating system locks up and the warm boot command does not work. To perform a cold boot, press and hold the following keys simultaneously:
Clean Boot
A clean boot is a cold boot that causes the device to be restored to factory configuration. The Jet will reset to its factory configuration, clear the working RAM and initialize the file system. You will lose any applications and data stored in persistent flash memory. At the next startup the system will ask to recalibrate the touch screen.
28
USE AND FUNCTIONING
3
To perform a clean boot, follow these steps:
1. Perform a Cold Boot (see Cold Boot).
2. Quickly release all the keys when the screen goes black.
3. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking.
4. Release the Esc and 0 keys.
5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot.
Warm
Cold Boot Clean Boot
Boot
Registry
Flash Disk (Backup
Preserved Restored from flash (if
available)
Factory default
Preserved Preserved Clean disk
Folder) RAM File System
Preserved Reinitialized (factory default) Factory
default
Windows Mobile
There are several reset methods for the Jet. A warm boot terminates an unresponsive application and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if available or returned to factory default. A cold boot forces all applications to close reinitializing completely the system. It clears the working RAM, but the file system is preserved. Registry are restored from persistent memory if available or returned to factory default. A clean boot restores the Jet to a clean configuration: both the registry and the file system return to a clean status that conform to factory default, unless the user has installed an additional package.
Warm Boot
A warm boot closes all applications and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.7.2) or returned to factory default. If an application hangs, initiate a warm boot to terminate the application. To perform a warm boot, press and hold the following keys simultaneously:
29
3
DATALOGIC JET™
Cold Boot
A cold boot is a complete reset of the Jet in which all applications are forcibly closed and the RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.7.2). Applications and data stored on file system are preserved. A cold boot is necessary when the Windows Mobile operating system locks up and the warm boot command does not work. To perform a cold boot, press and hold the following keys simultaneously:
Clean Boot
A clean boot is a cold boot that causes the device to be restored to a clean configuration. The Jet will be reset to its factory configuration only if the user has not installed any additional package. Please note that you will lose any applications and data stored in persistent flash memory. To perform a clean boot, follow these steps:
1. Perform a Cold Boot (see Cold Boot).
2. Quickly release all the keys when the screen goes black.
3. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking.
4. Release the Esc and 0 keys.
5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot.
Registry
File
Warm Boot Cold Boot Clean Boot
Restored from flash
Restored from flash
Clean configuration (no user config)
Preserved Preserved Clean Installation (no user files)
System
30
USE AND FUNCTIONING
3.5 STATUS INDICATORS
3.5.1 LED Status
The Datalogic Jet™ provides three different LEDs signaling the PDA status.

LED STATUS

General Purpose (left-side)
Bluetooth®
(extreme right -side)
Charging Status
(right side)
Green/Red This LED is available to the application
program.
Blue blinking
Green constant It is constant once the charging process
Red blinking It blinks when the battery pack is running
Red constant It is constant while charging.
Green/Red They turn on alternatively while
Orange blinking It blinks when a charging error has
It blinks when the Bluetooth® module is on.
has been completed.
down.
discharging.
occurred, for example when the external power is connected but no battery is inserted.
3
31
3
DATALOGIC JET™
3.5.2 Taskbar
As well as tasks opened in Windows, the Taskbar provides several status icons that report information about the time, the battery level, the keyboard function, and the decoding status.
ICONS DESCRIPTION
Time and Battery Icons
Keyboard Status Icons
Decoding Status Icons
It shows the time.
In Windows CE, they are representative of five different icons indicating the battery level. The icon is green or red colored according to the power left (green when >20%, red when <20%).
In Windows Mobile, it displays the system battery status.
It shows the battery is charging (Windows CE).
It shows the battery is charging (Windows Mobile).
It shows the Keyboard is in FUNC mode.
It shows the Keyboard is in ALPHA mode.
It shows the Keyboard is in Normal mode.
It shows the Capslock is active.
It shows the Keyboard is locked.
32
It shows the decoder is active.
It shows the decoder is not active.
USE AND FUNCTIONING
3
Windows CE Taskbar
Windows Mobile Taskbars
33
3
DATALOGIC JET™
3.6 DATA CAPTURE CONFIGURATION

From the Windows CE Taskbar, tap the "Data Capture" icon to open a drop–down menu. Data Capture can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading. The last menu item (Wedge) enables Wedge Emulation.

From the Windows Mobile Start menu, tap Settings -> System -> Data Capture. The "Data Capture" icon opens the configuration applet (Data Capture Configuration Window).
Windows CE Windows Mobile
3.6.1 Configure
The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure. The available barcode parameters are divided into two groups: Reader Parameters and Scan Parameters.
The Reader Parameters depend on the type of scanner module installed on the PDA and allow barcode configuration (i.e. enable/disable Code 39, check digit control, etc.).
34
USE AND FUNCTIONING
3
The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control, laser timeout, etc.).
Each Data Capture screen window corresponds to a branch of the tree, and the name of the current branch is displayed at the bottom of each screen window.
Data Capture Configuration Window
The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu.
Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu. To change a value for example, select the line of the value to be changed, choose Edit from the Parameter Menu then choose a new value from the values listed in the box (see following figures).
35
3
Selecting Data Capture Setup Parameters
DATALOGIC JET™
Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired value is reached.
To activate a new configuration select the File ->Save Menu to send the new configuration to the barcode decoding software and save the new configuration. This will save the configuration to non-volatile memory preventing loss at the next system reset.
Reader Parameters
The barcode reading parameters and values are dependent upon the type of scanner module mounted in your PDA. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.
Scan Parameters
The Scan Parameters are common to all scanner modules and allow control of the scanning device. The Scan parameters are described as follows:
ScanTimeout: the maximum time, in milliseconds, during which the scanner remains on without decoding any barcode.
GoodReadSound: is the filename of a .wav file played when the scanner reads a code.
LedDuration: the length of the good-read led pulse, in milliseconds.
LedPulses: the number of times the good-read led pulse is emitted when the
scanner reads a barcode.
36
USE AND FUNCTIONING
3
ContinuousMode: when enabled, the scanner can only be turned off by releasing
the SCAN key, or if Soft Trigger is enabled, by the application program. Continuous Mode overrides Scan Timeout.
KeyboardEmulation: if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved to a file as if input from the PDA keyboard. If set to “Yes (Clipboard)”, it copies the scanned data to the system clipboard.
SoftTrigger: when enabled, the laser can be turned on/off by the application software.
ScanAlwaysOn: enables the scanner for barcode reading independently from the application software. If set to “Disabled after read”, it disables the reading after a reading attempt. In case the scan button is accidentally pressed, this selection prevents the driver from decoding new data while the application is still elaborating previous data.
NotPrintableChar: if set to “Remove”, all not printable characters included in the scanned data are deleted and the final barcode will include only printable characters.
37
3
DATALOGIC JET™
Default Settings
The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the PDA. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.
SCAN PARAMETERS HP Laser Imager RFID+Laser ScanTimeout 5000 Not available 5000
GoodReadSound Beep.wav Beep.wav Beep.wav LedDuration 200 ms 200 ms 200 ms LedPulses 1 1 1 ContinuousMode Disabled Disabled Disabled KeyboardEmulation Disabled Disabled Disabled SoftTrigger Enabled Enabled Enabled ScanAlwaysOn Disabled Disabled Disabled NotPrintableChar Leave Leave Leave
BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS
UPC A UPC E EAN 8 EAN 13 UPC E1 EAN Bookland UPC/EAN/JAN Code 39 Code 39 Full ASCII Code 32 Code 39 Trioptic 2/5: Interleaved 2/5: Industrial 2/5: Matrix Code 128 EAN 128 ISBT 128 Codabar RSS
* In the Imager models these codes may only be enabled or disabled as a group by the UPC/EAN/JAN family selection (see a few lines below).
HP Laser Imager RFID+Laser
Enabled Enabled Enabled Enabled Enabled Enabled Enabled
*
Enabled Disabled Disabled Enabled Enabled Enabled Enabled Disabled Disabled Disabled Disabled Disabled Disabled Enabled Enabled Enabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Disabled Enabled Disabled Enabled Enabled Disabled Disabled
38
USE AND FUNCTIONING
BARCODE SYMBOLOGY SPECIFIC
HP Laser Imager RFID+Laser
READER PARAMETERS MSI Plessey Code 93 Code 11
PDF - 417 Data Matrix QR POSTNET PLANET Japan Post Australia Post KIX Code Royal Mail Code (RM4SCC)
Enabled Disabled Disabled Disabled Enabled Disabled Disabled Enabled Enabled Enabled
Disabled*
*These codes may be enabled individually but are disabled as a group.
RFID SYMBOLOGY PARAMETERS RFID+Laser Data Type I.CODE Iso-15693 Read Type Identifier
3
39
3
DATALOGIC JET™
3.6.2 Capture
The Data Capture applet (Capture) enables code reading.
Data Capture Window
Data Capture can also be enabled through the Configuration applet by selecting File
->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch.
40
Enabling the Data Capture
USE AND FUNCTIONING
3
3.7 CONTROL PANEL
From the Windows CE Desktop, double tap on the "Control Panel" icon to open the Windows CE control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel.
APPLET programs are displayed as icons; one icon corresponds to each APPLET.
Windows CE Control Panel
From the Windows Mobile Start menu, tap Settings. A three tab dialog opens: Personal, System, Connections.
APPLET programs are displayed as icons; one icon corresponds to each APPLET.
Windows Mobile Control Panel
41
3
DATALOGIC JET™
3.7.1 Buttons
The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3, F4).
Windows CE Buttons Icon Windows Mobile Buttons Icon
On a Windows Mobile unit the user is also able to assign a shortcut to a function key. The default programs/shortcut assigned to the function keys on Windows Mobile are the following:
F1 : select the Left Soft Key F2 : select the Right Soft Key F3 : open the Start Menu F4 : open the Today Screen
To configure the way up/down and the rest of keys control repeats, use the Up/Down Control applet (Start -> Settings -> Personal -> Buttons -> Up/Down Control).
42
USE AND FUNCTIONING
Select the “Enable Multipress” check box to enable multipress text input mode. To enables
F5, F6, F7, F8, F9, F10 function keys
, you need to change the
ORANGE key mapping. Select the “F5-F10” check box:
3
Windows CE Windows Mobile
If pressed along with keys [5 jkl], [6 mno], [7 pqrs], [8 tuv], [9 wxyz], [0 ], the ORANGE key now enables
F5, F6, F7, F8, F9, F10 function keys.
43
3
DATALOGIC JET™

3.7.2 Registry

The REGISTRY ADMIN applet provides management of Windows CE/ Windows Mobile registry.
From the Windows CE control panel main window, select the REGISTRY ADMIN applet by double tapping the Registry Admin icon.
From the Windows Mobile Start menu, tap Settings -> System ->Registry. Select the REGISTRY ADMIN applet by tapping the Registry Admin icon.
The Registry Administration Main window appears. Two functions are available:
- Save Registry allows permanently saving the Windows configuration (example: custom configuration of screen desktop background color, or network adapter configuration) to non-volatile memory (SAVE button).
- Restore Default Registry allows restoring the initial factory default configuration (Restore Default button). After restoring the factory default configuration, you must perform a warm boot (see par. 3.4.3).
Saving the registry to non-volatile memory guarantees the persistence of the Windows configuration in case of battery pack replacement, cold boot or warm boot on Windows Mobile.
44
Registry Administration Window
USE AND FUNCTIONING
3
3.7.3 Files Admin
The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because Windows Mobile mounts the entire file system in persistent store (rather than using RAM), it provides both users and applications with a reliable storage platform even in the absence of battery power. The FILES ADMIN applet is therefore not necessary.
Two functions are available on the Files Admin Main window by means of two buttons:
Files Admin Main Window
Save Session: with this button all files will be permanently saved in the \Windows
directory in non-volatile memory. This function guarantees the steady maintenance of every file produced during the current working session - even of sub-directories and relevant files - with the exception of the files belonging to the FLASH image. These current working session files will be backed-up in the \Backup\Windows directory. At the next cold boot, the files previously saved in the \Backup\Windows directory will be restored to the Windows directory (see par. 3.8.3).
Safe Setup: with this button, the installation of software programs will be saved to non-volatile memory (Backup directory). Before doing this, it will be checked that the Backup directory has enough space to save the files. If the directory space is not enough, an error message will be shown and the program will exit the Safe Setup function.
45
3
DATALOGIC JET™
Two activating procedures are available for Safe Setup:
- Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask.
Safe Setup First Mask
Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next cold boot, these files will be restored (see par. 3.8.3).
- Simply skip the first mask either by closing it or by pressing the ESC key. When it closes, a new mask will pop up: it will enable any type of installation (even remote ones like ActiveSync
®
installations). Make sure the installation directory is \Windows or one of its sub-directories. After installation, tap OK: Safe Setup will save the new files in the \Backup\Windows directory.
46
USE AND FUNCTIONING
3
Safe Setup Second Mask
47
3
DATALOGIC JET™
3.7.4 Wireless Communications
The WIRELESS COMMUNICATIONS applet provides management of the Wi-Fi Card and of the Bluetooth
®
and GSM/GPRS modules.
Windows CE Wireless Communications
Icon
Windows Mobile Connectivity Icon
If the PDA supports Windows CE, select the WIRELESS COMMUNICATIONS applet by double tapping the Wireless Communications icon. The following window will appear:
Windows CE Wireless Communications Window
48
USE AND FUNCTIONING
3
If the PDA supports Windows Mobile, the Wireless Manager application manages access to wireless connections. The 'Wireless Manager' is a sort of 'Control Panel' for bluetooth and phone modules. From here it's possible to turn on or off bluetooth and phone radio stacks. Open the Wireless Manager by tapping Start -> Settings -> Wireless Manager, or by tapping the
Connectivity icon located at the top of the screen. The following window
will appear:
Windows Mobile Wireless Communications Window
To turn on/off the WiFi radio open the Wi-Fi power applet by tapping Start -> Settings
-> System -> Power -> Wi-Fi:
49
3
DATALOGIC JET™
3.7.5 Ethernet Settings
Windows CE Ethernet cradle
Datalogic Jet™ can be connected to an Ethernet network by inserting it into the Datalogic Jet™ Ethernet Multi Cradle.
If the PDA supports Windows CE, ethernet communication requires Datalogic Jet™ SW version 5.41 or later. Verify the software version by tapping on Software – Version in the Datalogic default home
NOTE
When correctly inserted into the Ethernet Multi Cradle, the Ethernet driver installed on the mobile computer will automatically run, and using the DHCP service, will dynamically assign the IP Address.
1. From the Datalogic Jet™ open Internet Explorer>Internet Options and check use LAN no autodial then OK.
2. From the Datalogic Jet™ > Explorer, enter the IP address in the address bar (or name), of the PC on the network that you want to communicate with. You may be required to enter your network username and password. The LAN connection will take place and you can see the PC shared folders.
You can download files from the PC to Datalogic Jet™ but not vice versa. To do this use an FTP connection (see par. 3.8.3).
If your network provides Internet Service and does not use a proxy server you can directly access the Internet. Otherwise set the internet proxy parameters according to your network settings.
page. Otherwise, search for the file version.htm under the Windows CE folder.
50
USE AND FUNCTIONING
y
The LAN icon will appear on the Taskbar indicating the LAN connection status.
By double tapping on the LAN icon in the Taskbar, the LANNDS1 applet allows visualizing the TCP/IP information. Other information such as the MAC Address is available by tapping the Details... button.
If it is necessary to set static TCP/IP parameters, you must open the LANNDS1 applet from the Network and Dial-up Connections applet in the Control Panel. This applet is only visible when the mobile computer is correctl inserted into the Ethernet Multi Cradle.
LAN icon
3
Ethernet LANNDS1 Communications Window
The IP Address belongs to Datalogic Jet™ while the MAC address is specific to each cradle slot.
Windows Mobile Ethernet Cradle
Before using the ethernet cradle you have to un-check the 'COM1 Enable' option on the 'System Configuration' window (Start -> Programs -> System Configuration) and re-boot the unit.
For internet browsing through the ethernet cradle ensure that programs that automatically connect to the internet should connect using 'My Work Network' -> go to Start -> Settings -> Connections -> Connections -> Advanced -> Select Networks:
51
3
DATALOGIC JET™
then ensure that the USB/Ethernet Adapter card connects to Work -> go to Start -> Settings -> Connections -> Connections -> Advanced -> Network Cards:
52
USE AND FUNCTIONING
3
3.7.6 Volume Settings
From the Windows CE control panel main window, select the VOLUME SETTINGS applet by double tapping the Volume Settings icon.
From the Windows Mobile Start Menu, tap Settings -> System -> Volume Settings. Select the VOLUME SETTINGS applet by tapping the Volume Settings icon.
The Volume Settings applet allows managing the audio features and appears as follows:
Volume Settings Window
The window is divided into three tabs:
- Output tab: allows setting the volume for each audio profile;
- Input tab: allows setting the microphone recording volume;
- Cradle tab: allows selecting the cradle type and managing the vehicle cradle
headset functioning.
The Taskbar always displays the current audio profile, which is activated automatically (by the device) or manually (by the user). Available profiles are:
- Speaker: it is the typical profile reproducing audio through the mobile computer
speaker;
- Cradle: it is automatically activated as soon as the mobile computer is inserted
into the vehicle cradle. Audio is reproduced by the vehicle cradle loudspeaker.
- Headset: it is automatically activated as soon as a headset is directly connected
to the mobile computer. In case the device is inserted into the vehicle cradle and the headset is connected to the cradle, this profile must be manually activated through the dedicated button (refer to “Cradle Tab” paragraph). When this profile is active, the speaker does not work;
53
3
DATALOGIC JET™
- GSM: it is automatically activated each time a phone-call is started. It is not
available when using the cradle loudspeaker (in this case Current Profile = Cradle).
Output Tab
It allows setting the volume for each audio profile:
The “Master Volume” slider allows setting the volume used by all audio profiles. In addition, it is possible to attenuate the volume for each single profile through the dedicated slider.
Input Tab
It allows setting the microphone recording volume:
The “Record Gain” slider allows setting the recording volume, while the “Enable Preamplifier” check box enables/disables the preamplifier (this option is not selectable when Current Profile = Cradle or GSM).
54
USE AND FUNCTIONING
Cradle Tab
3
It allows selecting the cradle type and managing the vehicle cradle headset functioning:
Two radio buttons allow selecting the type of cradle to be used.
Check the “Cradle desk, AC plug or none” radio button, if using a cradle different from the vehicle cradle or an AC adapter plug.
If using a vehicle cradle, check the related radio button.
By inserting the mobile computer into the cradle when the “Cradle vehicle” radio button is checked, the mobile computer speaker is deactivated and audio will be reproduced through the vehicle cradle
NOTE
speaker or headset.
By selecting the “Cradle Vehicle” check box, a further button will appear allowing to enable the headset profile when using the vehicle cradle. If pressed, the button displays the headset icon in gray until the device is inserted into the vehicle cradle. Once inserted, the headset icon turns to green and the device activates the headset profile (refer to the following figures). Actually, the headset is ready to reproduce audio as soon as it is connected to the cradle jack:
55
3
DATALOGIC JET™
WARNING
Do not use the vehicle cradle headset if the headset button is disabled, since it may cause hearing damage.
56
USE AND FUNCTIONING
3
3.8 WINDOWS CONNECTIONS
To connect the PDA to another device (i.e. Host PC) from Windows, several programs are available in the "Connections" folder on the Datalogic Jet™ Desktop. These programs require specific electrical connections in order to function properly. From the Desktop, double tap on the "Connections" folder to open the following window:
3.8.1 Microsoft® ActiveSync®
Microsoft your Datalogic Jet™ PDA and synchronize the information on them. Synchronization compares the data on the Datalogic Jet™ PDA with that on the desktop computer and updates both computers with the most recent information.
With ActiveSync
- Back up and restore Datalogic Jet™ PDA data.
- Copy files between Datalogic Jet™ PDA and desktop computer.
- Synchronize files by selecting a synchronization mode.
You can establish an ActiveSync following electrical interfaces:
RS232 either directly or through the Datalogic Jet™ Single Cradle
USB either directly or through the Datalogic Jet™ Single Cradle
Bluetooth (see par. 3.8.2)
It is possible to constantly synchronize while connected to a desktop computer or, alternatively, synchronization can be performed only when the synchronize command is chosen. You can select which information types are synchronized and control how much data is synchronized.
®
ActiveSync® gives you the possibility to connect your desktop computer to
®
, it is possible to:
®
connection to your Datalogic Jet™ through the
NOTE
By default, ActiveSync® does not automatically synchronize all types of information. Use ActiveSync and off for specific information types.
®
options to turn synchronization on
For example: Synchronize Microsoft Word and Microsoft Excel files between the Datalogic Jet™ PDA and the desktop computer. The files will automatically be converted to the correct format.
57
3
In Windows Mobile before using the ActiveSync follow the directions described in 2.1.1
NOTE
Visit the following Microsoft Web site for the latest in updates and technical information:
NOTE
http://www.microsoft.com/windowsmobile/activesync/default.mspx
ActiveSync® Remote
Microsoft® ActiveSync® Remote is no longer supported in Windows CE. For backward compatibility you can download it from the internet. We suggest enabling the FTP Server and connecting to an FTP Client.
NOTE
See par. 3.8.3.
DATALOGIC JET™
58
USE AND FUNCTIONING
3

3.8.2 Bluetooth® Manager Device Setup

Windows CE Bluetooth® Manager Device Setup
In order to enable a Bluetooth PDA you must perform the discovery procedure and enable the device as follows:
1. Place the Bluetooth meters).
2. From the “Connections” folder double tap on the “Bluetooth” applet to open the Bluetooth
®
Manager Device window:
®
device for communication with the Datalogic Jet™
®
device within the range of the Datalogic Jet™ PDA (10
59
3
DATALOGIC JET™
3. Tap on the “Me” button to enter the related window; then, tap on the “ON” button to activate the Bluetooth
®
module. The module activation may be also performed
by using the WIRELESS COMMUNICATION applet as described in par. 3.7.4.
By tapping on the “HW Details” and “SW Details” buttons, information about the
PDA Bluetooth Encryption” button starts encryption of the Bluetooth tapping on the “Close” button the Bluetooth
®
hardware and software will be displayed, while the “Enable
®
Manager Device window will be
®
communication data. If
closed.
4. Tap on the “Discovery” button to enter the related window; then, tap on the “Scan” button to run the Discovery procedure:
60
USE AND FUNCTIONING
3
Once the Discovery procedure has been completed, select the desired Bluetooth the Bluetooth
®
device from the list. It is also possible to digit (12 hexadecimal digits)
®
address of the desired device by tapping on the “Add” button.
The “Clear” button deletes all discovered devices from the list.
®
5. Once the desired Bluetooth Wizard” button to enter the related window where selecting the connection type to be used for communication with the Bluetooth
device has been selected, tap on the “Connection
®
device:
The “Serial Port” button starts communication through the Bluetooth COM 5 (typically used for connection with GPS devices). The “Printer” button starts communication with a printer through the Bluetooth
®
serial port
®
serial port COM 5. The “Kbd Emulation” button allows connection with a barcode reader using the keyboard emulation. The “ActiveSync” button starts communication with a PC equipped with a Bluetooth
®
antenna and the related ActiveSync.
6. Hide the Bluetooth
®
Manager Device window by tapping on the icon available on each window or close it through the “Close” button available in the “Me” window (see step 3 of this procedure).
61
3
DATALOGIC JET™
Windows Mobile Bluetooth® Manager Device Setup
Before turning on Bluetooth®, ensure that the two devices are within close range and that both Bluetooth-enabled devices are discoverable.
1. Tap Start -> Settings -> Connections tab.
2. Tap Bluetooth > Mode
3. Select or clear the “Turn on Bluetooth” check box:
By default, Bluetooth® is turned off. If you turn it on, and then turn off your device, Bluetooth® also turns off. When you turn on your device
NOTE
again, Bluetooth® turns on automatically.
To create a Bluetooth® partnership between your device and another device that has Bluetooth® capabilities, ensure that the two devices are turned on, discoverable, and within close range.
1. Tap Start -> Settings -> Connections tab.
2. Tap Bluetooth -> Devices tab -> Add new devices. Your device searches for other devices with Bluetooth® capabilities, and displays them in the list:
62
USE AND FUNCTIONING
3
3. Tap the name of the other device, and tap Next:
4. In Passkey, if you want to use a passkey (recommended for enhanced security), enter a alphanumeric passkey between 1 and 16 characters, and tap Next. Otherwise, leave the passkey blank, and tap Next:
63
3
DATALOGIC JET™
5. Enter the same passkey on the other device.
6. To give the partnership a more meaningful name, change the name of the device in Name.
7. Tap Finish.
You can give a more meaningful name to a Bluetooth® partnership to help you recognize it when selecting from a list of partnerships.
1. Tap Start -> Settings -> Connections tab.
2. Tap Bluetooth > Devices tab.
3. Tap the partnership to rename.
4. In Name, enter a new name for the partnership.
5. Tap Finish.
To end a Bluetooth® partnership:
1. Tap Start -> Settings -> Connections tab.
2. Tap Bluetooth > Devices tab.
3. Tap and hold the partnership you want to end.
4. Tap Delete:
64
USE AND FUNCTIONING
3
Other devices with Bluetooth® capabilities can detect your device and attempt to beam information to it, establish a partnership, or use a Bluetooth® service. To make a device discoverable:
1. Tap Start -> Settings -> Connections tab.
2. Tap Bluetooth > Mode Tab.
3. Select the “Turn on Bluetooth” check box, and then select the “Make this device visible to other devices” check box:
Other Bluetooth®-enabled devices can now detect your phone and attempt to beam information to it, establish a Bluetooth® partnership, or use a Bluetooth® service.
65
3
DATALOGIC JET™
If you no longer want your device to be discoverable, clear the “Make this device visible to other devices” check box.
Your device will not detect and notify you of incoming Bluetooth® beams unless you set it up to do this. To receive a Bluetooth® beam:
1. Tap Start -> Settings -> Connections tab -> Beam:
2. Select the “Receive all incoming beams” check box:
3. Ensure that your device is turned on, discoverable, and within close range of the device that is beaming the information.
66
USE AND FUNCTIONING
3
4. When prompted to receive an incoming beam, tap “Yes” to receive the beamed information.
67
3
DATALOGIC JET™

3.8.3 FTP Server Setup

The Datalogic Jet™ Windows CE Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used for copying files to and from remote computer systems over a network using TCP/IP. You can establish a connection to your Datalogic Jet™ using its FTP Server through the following interfaces:
WLAN using the Wi-Fi radio
LAN through the Datalogic Jet™ Ethernet Multi Cradle (see par. 3.7.5)
Proceed as follows:
1. Create a registry file (extension .reg) to setup and enable FTP Server communication. A simple example file for anonymous logon is given below:
REGEDIT4
[HKEY_LOCAL_MACHINE\Comm\FTPD] "DefaultDir"="\\" "AllowAnonymousUpload"=dword:00000001 "UseAuthentication"=dword:00000000 "BaseDir"="\\" "IsEnabled"=dword:00000001 "LogSize"=dword:00001000 "DebugOutputMask"=dword:00000017 "DebugOutputChannels"=dword:00000002 "IdleTimeout"=dword:0000012c "AllowAnonymous"=dword:00000001 "AllowAnonymousVroots"=dword:00000001
2. Copy this file to the Datalogic Jet™ using ActiveSync
3. Launch the .reg file from the Datalogic Jet™.
4. Perform a warm boot on the Datalogic Jet™.
5. From the PC > Explorer address bar (or running an FTP Client from the PC), enter the Datalogic Jet™ IP address.
®
.
NOTE
68
For more information on FTP Client/Server connections refer to the following web page:
http://msdn2.microsoft.com/en-us/library/aa922316.aspx.
USE AND FUNCTIONING
3
3.9 BACKUP DIRECTORY FILE MANAGEMENT
All of the Windows CE system files reside in RAM (volatile memory) except for the Backup directory, which resides in FLASH (non-volatile memory). Therefore the contents of the Backup directory are persistent even if the PDA is re-booted or the battery pack is changed.
You can save your more important files that you don't want to lose due to PDA re­boot, in the Backup directory or create a sub-directory within Backup.
Even though the Windows Directory resides in RAM, it often contains files or sub­directories created by the user or by installation programs that you don't want to lose at re-boot. To keep these files persistent it is necessary to copy them to the directory \Backup\Windows. This directory doesn't exist originally (only Backup exists), and therefore it must be created. At the next cold boot, before activating the shell, Windows CE will copy the contents including all sub-directories of \Backup\Windows to \Windows.
Likewise, to maintain files that must be run at Windows CE startup, (i.e. .exe, .lnk, .vb, .htm, etc.), it is necessary to copy them to the directory \Backup\Startup. This directory does not exist originally (only Backup exists), and therefore it must be created. The application programs will be run after any type of re-boot (both software and cold boot).
As an alternative to the Safe Setup function, it is possible to copy the .cab files to the directory \Backup\Cabfiles (the Cabfiles sub-directory doesn't exists originally and must therefore be created) and perform a PDA cold boot to have the application installed. Once these files are copied to the directory \Backup\Cabfiles, the application will be run after each re-boot.
From the second cold boot on, a message may be displayed such as "<application name> is already installed. Re-install?". This message blocks the boot process. Press the [Enter] key to continue the system initialization.
Even if the entire Windows Mobile file system reside in FLASH (non-volatile memory), the mechanism described above is supported also on Windows Mobile for backward compatibility.
69
4
DATALOGIC JET™
4 MAINTENANCE
Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See below.
NOTE
4.1 CHARGING THE BATTERY PACK
It is possible to recharge the battery pack by using the PG12-10P35 AC/DC external power supply directly connected to the Datalogic Jet™ PDA, see par. 2.1.1.
Alternatively, it is also possible to recharge the battery pack by using the Datalogic Jet™ Single Cradle Desk or the Datalogic Jet™ Vehicle Cradle.
The charging process is signaled by a bi-colored charging status LED positioned at the right side of the display (see par. 3.5).
When the battery pack is low, the red LED positioned at the left side of the display blinks.
If the battery pack is removed from the PDA, it can be recharged by inserting it into the Datalogic Jet™ Multi-Battery pack Charger.
NOTE
CAUTION
70
The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc.
If the battery pack is new or has not been recharged for a long time, it is necessary to perform two or three charging and discharging cycles (complete use) before it can reach its maximum charge capability. The maximum time required to recharge a completely run-down battery pack is about 2.5 hours for Li-Ion batteries.
MAINTENANCE
NOTE
4
Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 ºC (68 to 86 ºF).
The Batteries must be charged at a temperature ranging from 0° to +45 °C (+32° to +113 °F).
71
4
DATALOGIC JET™
4.2 REPLACING THE BATTERY PACK
To correctly replace the battery pack, proceed as follows.
1. Turn off the Datalogic Jet™ PDA.
2. Press the latch release button and pull the battery latch down as indicated in the figures below:
3. Remove the battery pack.
72
MAINTENANCE
4
4. Replace the battery pack by pressing the latch release button and pulling the battery latch down, and then by inserting it towards the speaker and pressing it into the Datalogic Jet™ PDA until the battery latch is automatically closed:
CAUTION
When the latch release button is pressed, the PDA automatically shuts off, in order to retain data during the pack substitution. After the new pack insertion, be sure that the battery latch has completely slid over the pack so that the latch release button is released.
73
4
WARNING
DATALOGIC JET™
Use only a Datalogic Mobile approved power supply. Use of an alternative power supply will void the product warranty and may cause product damage. Do not apply voltages to the batteries contacts.
Risk of explosion if the battery is replaced by an incorrect type.
Do not use the batteries of this terminal to power devices different from this mobile computer.
Do not place the battery in or near a fire or heat as they may explode.
Do not place the battery in direct sunlight, or use or store the battery inside unventilated areas in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high pressure containers, or on induction cookware.
Immediately discontinue use of battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way.
Do not short-circuit the battery contacts. Accidental short-circuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery (these look like metal strips on the battery).
Do not carry or store battery pack together with metal objects (this might happen, for example, when you carry a spare battery in your pocket or purse). Short­circuiting the terminals may damage the battery or the connecting object.
74
Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks.
Do not solder directly onto the battery pack.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Do not expose the battery pack to liquids.
MAINTENANCE
In order to guarantee an adequate operating autonomy, when replacing the battery pack the PDA checks the battery energy level. If the battery is not sufficiently charged, Datalogic Jet™ does not turn on (when pressing the ON button).
NOTE
In this case, either substitute the battery pack with a charged one (sufficiently charged) or insert Datalogic Jet™ into a powered cradle or plug it into the direct power supply.
To achieve the best battery life, turn off the radios not in use.
NOTE
4.3 CLEANING THE PDA
Periodically clean the Datalogic Jet™ PDA with a slightly dampened cloth. Do not use alcohol, corrosive products or solvents.
4
75
5
DATALOGIC JET™
5 TECHNICAL FEATURES
5.1 TECHNICAL DATA
Datalogic Jet™ Common Features
Electrical Features
Power DC supply 12 to 14 V ± 5% Battery pack 2 cell Li-Ion 1070 mAh@ 7.4 V (nominal) Large capacity pack 2 cell Li-Ion 1800 mAh@ 7.4 V (nominal) Internal backup battery Rechargeable Li-Ion 30 mAh
Communication Features Windows CE COM Port
Bluetooth interface COM5 Serial interface RS232
USB 1.1
Wireless Features
WLAN IEEE 802.11b DSSS WPAN Bluetooth® IEEE 802.15, Class 2, Version 1.2 WWAN GSM/GPRS Tri-band (900, 1800, 1900 MHz)
Radio with accessible SIM card interface
Hardware Features
FLASH 128 MB DRAM 128 MB Microprocessor Intel XScale PXA-270 520 MHz Accessible card socket Mini SD Audio Speaker, Microphone, Headset Jack LED Two-color Programmable LED
Charging Status (two-color LED) Bluetooth® (blue LED)
Display 64K Color TFT LCD with 320 x 240 pixel resolution, with
LED backlight and touch screen
Keyboard 25 Plastic Top Backlit Keys plus Power Button plus 2
Lateral Push-buttons
Environmental Features
Working temperature * -10° to + 50 °C / +14° to +122 °F Storage temperature -20° to +70 °C / -4° to +158 °F Humidity ** 90% non condensing for temperatures<40°C Protection IP64 ESD protection 4 KV contact discharge, 8 KV air discharge Drop resistance *** 1.5 m / 5 ft
* Close to the limits of the working temperature, some display and/or battery performance degradation may occur. ** Multiple rapid humidity and/or temperature variations may cause condensing. *** Multiple drops can permanently damage the device.
COM1 COM6
76
TECHNICAL FEATURES
5
Mechanical Features
Dimensions (LxWxH) 17.6 x 9 x 2.8 cm / 6.9 x 3.5 x 1.1 in Weight (depending on model) 424– 465 g / 14.9–16.4 oz (incl. battery)
Programming Features
Operating system Windows CE 5.0 Professional
HP Laser models
Decoded barcodes 1D UPCA A, UPC E, EAN 8; EAN 13,Code 39, Code 39 Full
ASCII, Code 32, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Code 128, EAN 128, Codabar, MSI, Plessey, Code 93, Code 11
RFID + Laser models
Decoded barcodes 1D UPC A, UPC E, UPC E1, EAN 8, EAN 13, EAN Bookland,
Decoded RFID Tags EMS HMS Series, EMS LRP ISO15693 Series, Philips
Imager models
Decoded barcodes 1D UPC A, UPC E, EAN 8, EAN 13, UPC/EAN/JAN,
Decoded barcodes 2D PDF417, DataMatrix, QR, MacroPDF, RSS. Postal codes POSTNET, PLANET, Japan Post, Australia Post, KIX
Code 39, Code 39 Full ASCII, Code 32, Code 39 Trioptic, Interleaved 2 of 5, Industrial 2 of 5, Code 128, EAN 128, Codabar, MSI, Code 93
Mifare Classic 1k (read/write block only), Philips Mifare Classic 4k (read/write block only), Philips Mifare Ultralight, Philips I-Code SLI ISO15693, Texas Tag-It HF-I ISO15693, Infineon ISO15693
Interleaved 2 of 5, Code 39, Code 39 Full ASCII, Codabar, Code 128, EAN 128, Code 93.
Code, Royal Mail Code (RM4SCC)
Datalogic Jet™ HP Laser / RFID +Laser Optical Features
Optical Features
Datalogic Jet™
HP Laser
Maximum resolution 0.13 mm / 5 mils 0.13 mm / 5 mils Skew angle ± 55 ° ± 60° Pitch angle ± 65° ± 65° Scan rate 35 ± 5 scan/sec 39 ± 3 scan/sec Depth of field See reading diagrams on the next page Light source laser scanner VLD, wavelength 630~680 nm Safety class Class II EN 60825-1/CDRH
Datalogic Jet™
RFID + Laser
77
5
DATALOGIC JET™
Datalogic Jet™ Imager Optical Features
Optical Features
Max. resolution 1D Codes 0.10 mm / 4 mils 2D Codes 0.17 mm / 6.6 mils Skew angle ± 40 ° Pitch angle ± 35°
Depth of field*
1D (linear):
Code39 0.13 (5) 1.2 (0.47) 8.0 to 15.0 (3.15 to 5.90)
0.50 (20) 3.2 (1.26) 8.0 to 33.0 (3.15 to 12.99) EAN13 0.33 (13) 3.1 (1.22) 7.5 to 24.5 (2.95 to 9.65)
2D:
POSTNET 0.5 (20) 4.0 x 0.4 (1.57 x 0.16) 11.5 to 30.0 (4.53 to
PDF417 0.13 (5) 1.1 x 0.9 (0.43 x 0.35) 8.5 to 15.5 (3.35 to 6.10)
0.17 (6.6) 1.4 x 1.2 (0.55 x 0.47) 7.0 to 19.0 (2.76 to 7.48)
0.25 (10) 2.2 x 1.8 (0.86 x 0.71) 4.5 to 24.0 (1.77 to 9.45)
QR 0.25 (10) 0.7 x 0.7 (0.28 x 0.28) 7.0 to 15.5 (2.76 to 6.10)
0.38 (15) 1.1 x 1.1 (0.43 x 0.43) 4.5 to 21.0 (1.77 to 8.27)
DataMatrix 0.19 (7.5) 0.8 x 0.8 (0.31 x0.31) 9.0 to 13.0 (3.54 to 5.12)
0.25 (10) 0.8 x 0.8 (0.31 x 0.31) 7.5 to 16.5 (2.95 to 6.50)
0.38 (15) 1.0 x 1.0 (0.39 x 0.39) 6.0 to 22.0 (2.36 to 8.66) Sensor 640 x 480 pixel element, 2D CMOS array
Illuminator LED array Wavelength 630~670 nm LED Safety class Class 1 to EN 60825-1 Aiming System Visible Laser Diode Wavelength 650 nm Laser Safety Class
X-dimension
mm (mils)
X-dimension
mm (mils)
Class 2 EN 60825-1; Class II CDRH
Symbol size
cm (in)
Symbol size
cm (in)
DOF
cm (in)
DOF
cm (in)
11.81)
*Reading distances are measured from the nose of the reader using the test codes. The reading performances may vary depending on the code printing quality.
78
TECHNICAL FEATURES
5.2 READING DIAGRAMS
DLBJET™ HP Laser (XXX-1XX-XXX models)
300
200
0.13 mm
(5 mils)
100
0
100
Reading Zones (10° skew angle)
0.25 mm
0.19 mm
(7.5 mils)
(10 mils)
0.38 mm (15 mils)
0.50 mm (20 mils)
1.00 mm (40 mils)
5
200
300
mm
100 200 400
EAN
0.33 mm (13 mils)
300 500
600
700 800 mm
DLBJET™ RFID +Laser (XXX-4XX-XXX models)
300
200
100
0
100
200
300 mm
Reading Zones (10° skew angle)
0.38 mm
0.50 mm
(15 mils)
(
)
0.13 mm
(5 mils)
0.19 mm
(
7.5 mils
)
0.25 mm (
10 mils
on Code 39
100 200 400
300 500
20 mils
1.00 mm (40 mils)
)
600 mm
79
6
ÌtestwÎ
6 TEST CODES
0.25 mm (10 mils)
Code 39
High Density Codes
DATALOGIC JET™
17162
2/5 Interleaved
0123456784
Code 128
test
80%
EAN 13
x(0B2DE5*KKKKLM(
80%
EAN 8
80
(6450*TRMN(
TEST CODES
ÌtestwÎ
6
0.38 mm (15 mils)
Code 39
Interleaved 2/5
Code 128
17162
0123456784
test
100%
Medium Density Codes
EAN 13
EAN 8
x(0B2DE5*KKKKLM(
100%
(6450*TRMN(
81
6
ÌtestwÎ
DATALOGIC JET™
0.50 mm (20 mils)
Code 39
Interleaved 2/5
Code 128
17162
0123456784
test
120%
Low Density Codes
EAN 13
EAN 8
82
x(0B2DE5*KKKKLM(
120%
(6450*TRMN(

GLOSSARY

Access Point
A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held terminals, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (PDA), may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network.
Barcode
A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format.
Baud Rate
A measure for data transmission speed.
Bit
Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning.
Bits per Second (bps)
Number of bits transmitted or received per second.
Bluetooth®
A standard radio technology using a proprietary protocol. The onboard Bluetooth module in the PDA is compatible with the 1.2 protocol.
Byte
On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character.
Decode
To recognize a bar code symbology (e.g., Codabar, Code 128, Code 3 of 9, UPC/EAN, etc.) and analyze the content of the bar code scanned.
83
EEPROM
Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip.
Flash Disk
Non-volatile memory for storing application and configuration files.
GSM
Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands.
GPRS
General Packet Radio Service. GPRS is a wireless packet-based communication service based on GSM. Its data transfer is rated between 56 Kbps to 114 Kbps. It makes very efficient use of available radio spectrum, and users pay only for the volume of data sent and received.
Host
A computer that serves other terminals in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages.
Liquid Crystal Display (LCD)
A display that uses liquid crystal sealed between two glass plates. The crystals are excited by precise electrical charges, causing them to reflect light outside according to their bias. They use little electricity and react relatively quickly. They require external light to reflect their information to the user.
Light Emitting Diode (LED)
A low power electronic light source commonly used as an indicator light. It uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD).
PDA
Personal Digital Assistant. PDA is a term for any small mobile hand-held device that provides computing and information storage and retrieval capabilities for personal or business use, often for keeping schedule calendars and address book information handy.
RAM
Random Access Memory. Data in RAM can be accessed in random order, and quickly written and read.
RF
Radio Frequency.
84