Chinese ...................................................................................... 60
Japanese .................................................................................... 61
Europe – EU Declaration of Conformity ......................................62
2Pegaso™ Industrial PDA with Windows® CE
Pegaso
™
Industrial PDA
with Windows® CE
Overview
The Datalogic™ Pegaso industrial PDA combines the flexibility of Windows®
CE with the power of the Intel XScale processor, Wi-Fi wireless technology, a
large color display, and laser scanning in an ergonomic PDA. The Pegaso is a
rugged device suitable for both Commercial and Industrial environments, as
well as Retail-in-Store inventory management applications (back room inventory management and shipping/receiving, shelf inventory management, price
lookup, and relabeling applications). The Pegaso will handle 5’ / 1.5M drops to
concrete, and has an IP64 environmental rating.
The Datalogic Desktop Utility (DDU), Datalogic Configuration Utility
(DCU), and Wavelink Avalanche™ are included with every unit, providing
remote management and configurability.
Features
• End user configurable keypad with custom overlay available
• Best in class Full VGA 3.6” Display for indoor and outdoor use
• Ergonomic design
• 2200 mAHr battery or 3300 mAh extended battery
• Bluetooth direct to Host PC (no dock necessary), 802.11b/g available
• User accessible SDIO slot on top
• No tools required for attachables & expansion
• High power output (500mA) on base connector, allows multiple attachables or tethered/powered scanners
• Single piece quick-replace battery/cover
• 64 or 128 MB RAM, 128 MB Flash
Quick Reference Guide3
Overview
To u ch -
screen
Display
LED Scanning/
Charging Indicators
Keypad
SD Door
Top View
Antenna
(GPRS only)
Scanner Aperture
Belt Clip
Handle
(Optional)
Stylus
Scan
Triggers
Powe r Key
Handstrap
Battery Pack
Speaker
Figure 1. Pegaso Front & Rear Views
For a complete description of each key on the Pegaso, refer to page 19 in this
manual. Also refer to the Pegaso Windows
®
CE Product Reference Guide(PRG),
available on the Pegaso Product CD included with each unit, or from the Datalogic Mobile web site at www.mobile.datalogic.com.
4Pegaso™ Industrial PDA with Windows® CE
Getting Started
Getting Started
Before using the Pegaso for the first time, you must install the Battery Pack into
the unit, then charge both the Battery Pack and the Backup Battery. See Installing the Battery Pack on page 7 for instructions
You must charge the battery pack and backup battery in a dock or
with a power cable prior to your first use of the Pegaso. The initial
charge time is approximately 4 hours. See Charging the Batteries on
CAUTION
page 10 for more information.
.
Powering the Pegaso
Battery Pack
The battery pack in the Pegaso is a 3.7 V, 2200
mAh or 3300 mAh Lithium Ion battery pack. A
message dialog box will appear when the battery
pack reaches a low state.
After charging the first time, a complete charge
takes about four (4) hours depending on the battery pack’s state and the recharging method. A
sample battery pack label is shown at right. The
label on your unit may vary from the illustration.
C US
®
LISTED
NWGQ7 2Z78
Li-Ion 3.7V 2200mAh (High Capacity 3300mAh)
CAUTION: Do not short circuit, disassemble,
incinerate or mutilate pack.
Datalogic Mobile, Inc Made in China
P/N: xxxx-xxxx (High Capacity P/N: xxxx-xxxx)
S/N: xxxxxx
Quick Reference Guide5
Powering the Pegaso
You must charge the battery pack and backup battery in a dock or
with a power cable prior to your first use of the Pegaso. The initial
charge time is approximately 4 hours.
If you remove the battery pack or it fails, there is a 30-minute window
CAUTION
in which to insert a charged battery pack before the backup battery
fails. If your backup battery fails, the contents of the RAM memory
will be lost. If your backup battery is less than fully charged, there is a
smaller window of time available. Usage time will be reduced, also.
Always charge within temperature range of 32°–113°F (0°–40°C). Reg-
ularly charging near the temperature limits will increase the time nec-
essary to fully charge the battery, and will shorten the battery’s useful
life.
Use only the authorized power supplies, battery packs, chargers, and
docks supplied by your Datalogic reseller. Use only the battery pack
that is specified. Only use the battery with a charging system that has
been qualified with the system per this standard. Use of an unquali-
fied battery or charger may present a risk of fire, explosion, leakage,
or other hazard. Unauthorized battery pack and improper use of either
battery pack or charging system may present a risk of fire, explosion,
leakage or other hazards. The use of other power supplies can dam-
age the unit and void your warranty. Refer to the PRG for the correct
power supplies and Accessories.
6Pegaso™ Industrial PDA with Windows® CE
WARNING
Powering the Pegaso
Lithium-ion battery packs may get hot, explode, ignite, or/and cause
serious injury if exposed to abusive conditions.
•Do not place the battery in or near fire, direct sunlight, or other
high temperature locations, or heat the battery.
•Do not connect the positive terminal and negative terminal of the
battery to each other or short circuit battery terminals with any
metal object (such as wire, coin or metallic object).
•Do not expose the battery to liquids, or allow to get wet.
•Do not disassemble, modify, open, crush, bend, deform, puncture,
shred, remanufacture or pierce the battery. The battery contains
safety and protection devices, which, if damaged, may cause the
battery to generate heat, explode or ignite.
•Use only battery packs that have been authorized by Datalogic per
IEEE Standard 1725-200x for GSM/GPRS/EDGE operation.
•Promptly dispose of used batteries in accordance with local regu-
lations.
•Battery usage by children should be supervised.
•Avoid dropping the PDA or battery. If the PDA or battery is
dropped, especially on a hard surface, and the user suspects dam-
age, return it to a service center for inspection.
•Only use the battery for the system for which it is specified.
In the event the battery leaks and the fluid gets into your eye, do not
rub the eye. Rinse well with water and immediately seek medical care.
If left untreated, the battery fluid could cause damage to the eye.
Datalogic recommends annual replacement of rechargeable battery
packs to ensure maximum performance.
Installing the Battery Pack
When you first remove the Pegaso from the box, you must charge
both the battery pack and the backup battery for a minimum of 4
hours.
The Pegaso’s Battery and its cover are integrated — they do not come apart.
Complete the following instructions to install the battery pack:
1.Loosen the elastic handstrap by releasing it from the bottom of the unit
(refer to the PRG).
2.Orient the battery pack with the latch facing toward the top of the Pegaso
(refer to
3.Replace the battery door by inserting the bottom tab into the unit, then
clicking the latch into place. If the battery pack is installed incorrectly, it
will not seat properly.
Quick Reference Guide7
Figure 2 on page 8).
Battery Power
Battery Pack
Seat this
end first
Battery Latch
(push in to release)
ab
4.Replace the handstrap at the bottom of the unit.
Figure 2. Installing the Battery Pack
Battery Power
If you remove the battery pack or the battery fails, you have about 30
minutes to swap in a new battery pack or charge the battery pack
before the backup battery fails (if the backup battery has been fully
charged).
System Tray Battery Status Indicators
The System Tray displays icons to show the status of some battery conditions,
as shown in Ta b le 1.
Table 1. System Tray Battery Status Indicators
Battery Status Icons
Battery
Status
Backup
Battery Low
Condition
Backup
Battery Very
Low
Condition
8Pegaso™ Industrial PDA with Windows® CE
IconDescription
no icon
The battery status is updated in the control panel, but no icon is
displayed.
When the backup battery is very low, the system tray contains a
very low backup battery CAUTION icon. In addition, a dialog box
pops up and alerts you that the backup batter y is very low and
needs to be charged. The dialog comes up every five minutes until
you charge the backup battery.
Battery Status Icons
Main batteries
Remaining power:
0100
Battery Power
Battery
Status
Battery
Charging
Condition
Battery Low
Condition
Battery Very
Low
Condition
Battery
Power
Gauge
Discharged
Battery
Condition
IconDescription
This icon indicates that the battery pack is currently charging.
This icon indicates that the battery pack is low.
When the battery pack is very low, the system tray shows a very
low battery CAUTION icon. Also, a dialog box pops up and alerts
you to charge the battery pack. A battery warning dialog will pop up
every five minutes until you charge the battery.
The Power control applet displays a battery
power gauge.
Start > Settings > Control Panel > Power.
When the battery is totally discharged, the battery sensor initiates a
shutdown of all applications, and closes the RF Network connec-
tion. If the battery pack has completely discharged, when the bat-
no icon
tery pack is charged or replaced, the unit will resume as before
after a cold reset.
Refer to Persistent Memory on page 23 regarding the data loss of
applications and data stored in RAM.
Quick Reference Guide9
Battery Power
Charging the Batteries
There are several methods for charging the battery pack and backup battery.
LEDs on the Pegaso, the Single-Slot Dock, and the Four-Slot Battery Charger
give visual indication of the charge state.
of all the LEDs and what they indicate.
Table 2. Battery Charging Methods and Indications
Table 2 on page 10 gives an overview
Charging
Location:
Charging
Duration
Battery Pack
Charge
Indication:
Pegaso
Charge LED
Dock or
Charger
Battery
Charge LED(s)
Simulta-
neously
Charges
Backup Bat-
tery
Pegaso seated in
a Dock (Single or
Four-Slot)
4-6 hours
Charging: RED
Fully Charged:
GREEN
Battery above or
below allowed
charging
temperature, or
Battery
Communication
Fault:
FLASHING RED
No effectNo effect
YESYESN/AN/A
Pegaso
connected to an
external power
supply
4-6 hours3-5 hours> 3 hours
Charging: RED
Fully Charged:
GREEN
Battery above or
below allowed
charging
temperature, or
Battery
Communication
Fault:
FLASHING RED
Charging slot of
Dock (Single or
Four-Slot)
N/AN/A
Charging:
Solid RED
Fully charged:
GREEN
Fault:
FLASHING RED
Pegaso
Four-Slot
Battery Charger
Charging:
LEDs are RED
Fully charged:
Ready LEDs are
GREEN
Error: AMBER
10Pegaso™ Industrial PDA with Windows® CE
Battery Power
USB/Serial Connector
Pull Upward to Remove
LEDs
Battery Pack in
Charger
Charging with the Dock
A Single-Slot Dock powered by an external power supply (AC adaptor) is available for the Pegaso. Pegasos communicate with the host PC using Microsoft
ActiveSync protocol via either a USB or serial port.
Two methods exist for charging a battery pack using a Single-Slot Dock. Refer
Table 2 on page 10. The amber light on the dock will blink when a battery is
to
inserted, to indicate a successful connection. For more information on the
Dock, refer to the PRG, or the instructions that come with each dock.
Figure 3. Charging the Battery Pack in a Dock
Refer to Table 2 on page 10 for a list of LED indicators and their purpose.
Refer to the PRG for more info on storage and disposal of batteries.
Quick Reference Guide11
Setting Up the Mobile Computer
LEDs
Charging with a Battery Charger
The Pegaso is available with a Four-Slot Battery Charger. Use the Battery
Charger to charge batteries independently of the unit.
Figure 4. Four-Slot Battery Charger
Backup Battery
The rechargeable 3.7V Lithium Backup Battery receives its charge from the Battery Pack. To retain date, time, data, and other settings for the Pegaso, maintain
at least a minimal charge on the Battery Pack.
To maximize the backup battery usable life always store the unit with a main
battery installed or place the unit in a charging dock when not in use.
When the backup battery is low, an icon will display on the status bar (see
Table 1 on page 8), and a dialog box will open to alert you.
Setting Up the Mobile Computer
At first use or cold reset, the unit will go through an initial bootup sequence:
1.Touchscreen Calibration on page 13.
2.Getting Connected on page 13.
3.IP Network Setup on page 13.
4.Setting the Date and Time on page 15.
12Pegaso™ Industrial PDA with Windows® CE
Setting Up the Mobile Computer
Follow the on-screen directions to calibrate
the touchscreen.
For more information on touchscreen cali-
bration, refer to the PRG.
Touchscreen Calibration
Figure 5. Touchscreen Calibration
Getting Connected
Bluetooth Setup
1.Open the Bluetooth control panel at Start > Settings > Control Panel >
Bluetooth Manager
.
2.Search for available Bluetooth Devices by tapping the button for the type
of device you want
(Printer, Serial or All) .
3.Create a pairing by double tapping the listing for the device you want and
selecting the service. If you want to specify encryption or require authentication, enable the appropriate checkbox.
4.Tap
OK to complete.
For detailed instructions, reference the PRG.
Connecting to a PC
In order for the Pegaso to communicate with a host PC, Microsoft® ActiveSync
must be installed on the computer. Go to www.microsoft.com/downloads/ for
information. Reference the Pegaso PRG for detailed instructions.
IP Network Setup
1.Select Start > Settings >Network and Dialup Connections.
2.Double-tap on the item (varies based on the radio installed and the number of connections).
Quick Reference Guide13
Setting Up the Mobile Computer
3.Complete the two tabs (shown in Figure 6):
Figure 6. Modifying Network Connection Settings.
• IP Address: Select DHCP or set static IP settings.
•
Name Servers: If using static IP, set DNS and WINS servers.
RF Setup (Summit Client Utility)
The Summit Client Utility (SCU) is an application designed for users and
administrators of mobile devices that use a Summit radio module. Using SCU,
you can:
• Disable and enable the radio (turn it off and on)
• View the contents of configuration profiles, or configs, each of which
houses the RF, security, and other settings for the radio
• Select the config to be used to connect to a WLAN
• View global settings, which apply to every config
• View status information on the radio, the access point (AP) or WLAN
router to which it is connected, and the RF connection or link between
the two
• Troubleshoot a connection or performance issue, view in-depth diagnostic information on the connection and the radio, and perform various
troubleshooting and diagnostic tests
1.To launch the utility go to
Start > Settings > Control Panel.
2.Tap on the Wi-Fi icon.
3.To make setting changes tap
The default password is
Admin Login.
SUMMIT.
For more detailed information on making changes to settings, please refer to the
PRG.
14Pegaso™ Industrial PDA with Windows® CE
Setting Up the Mobile Computer
Setting the Date and Time
1.From the Start menu, select Settings >
Control Panel > Date/Time
navigate or change the time or date.
2.Change the year by backspacing, or entering a new year.
3.Select the month to open a pull-down list
of months.
. Use the arrows to
4.Tap the checkbox to
clock for daylight savings time
Automatically adjust
, if desired.
Using the Stylus
Never use a pen, pencil, or other sharp object on the Pegaso’s
touchscreen display. Use only the supplied stylus or plastic-
tipped pens intended for use with a touch-sensitive display. Con-
tact your reseller to replace a missing stylus.
The stylus is located next to the scanning pod as illustrated in Figure 7. The stylus on the Pegaso is the equivalent of the mouse on a PC. Use the stylus to:
• Navigate the touchscreen display.
• Select characters in the soft input panel (SIP).
• Select applications from the desktop or system tray.
• Select tabs, fields and text within applications and dialog boxes.
Quick Reference Guide15
Navigating the Display
Stylus
Stylus Holder
Scanner Aperture
Tether
Figure 7. Back View of a Pegaso with a Stylus
Ambient Light Sensor
The ambient light sensor is used by the Pegaso to automatically adjust the intensity of the backlight on the display and keypad in response to changes in lighting conditions. It is located on the keypad. Reference the Pegaso PRG for
information on enabling or disabling this feature.
Screen Protector
A Screen Protector is available for the Pegaso. Reference the Pegaso PRG for
information on installation.
Navigating the Display
There are several navigation areas on your display, including the command bar,
and task bar. Each of these navigation areas have sub-areas of navigation as well.
Take the time to familiarize yourself with these features to save yourself valuable
time.
The Command Bar
Use the Command bar at the top of the screen to perform tasks in programs, such
as opening a file, saving a file, or editing a file. Refer to
16Pegaso™ Industrial PDA with Windows® CE
Figure 8.
Figure 8. Application Navigation
Task Bar (Bottom)
Command Bar (Top)
Extras Menu Button (Open Applications)
System
Tr ay
Soft Input
Panel
Start Button
Network Connection
Active Application Window
Desktop
Applica-
tion Icons
AC Power Indicator
Navigating the Display
The Task Bar
The Task bar at the bottom of the screen displays the start menu icon, an icon
for the active program, the current time, and system icons for utilities loaded in
memory, including the keyboard icon, which opens and closes the soft input
panel (SIP).
Start Button —
includes access to
command. From
Connections
System Tray —
applets running in the background. Click the small arrow(s) in the
to view icons for current input mode(s), keypress, power management, and network connections.
Extras Menu —
open applications or to access the desktop while leaving a program open.
Quick Reference Guide17
Click the Start button to open the Start menu. The Start menu
Programs, Favorites, Documents, Settings, Help, and the Run
Settings you can access the Control Panel, Network and Dial-up
, and the Taskbar and Start Menu.
The System Tray contains icons for key presses, utilities and
Ta p Extras Menu at the far right of the Tas k bar to select from
System Tray
Navigating the Display
Soft Input Panel
Keyboard Icons
Soft Keypad/Input Panel
In applications that accept keyed input, the soft input panel (SIP) can be used to
enter data using the stylus. The
Figure 9. Soft Input Panel
SIP is a digital, QWERTY-style keyboard.
To open the SIP: —
board
from the pop-up menu to open the keyboard.
To close the SIP: —
Input Panel
to close the keyboard.
Use the stylus to select letters, numbers, or symbols from the
Tap th e Keyboard icon to open the menu and select Key-
Tap th e Keyboard icon to open the menu and select Hide
Soft Input Panel for
the current application. Tap the key to show international letters.
Transcriber
Select Transcriber to provide keyboard input using handwriting and gestures on
the touchscreen. You can use the stylus to write words, numbers or symbols
directly on the screen, and the result will be sent to the current application. A
help screen will appear upon first use.
Figure 10. Transcriber
18Pegaso™ Industrial PDA with Windows® CE
Keypad
Keypad
The Pegaso is available with a 19-key keypad. Refer to the PRG for information
on configuring the keypad.
Table 3. Keypad Overview - Special Keys
Key NameFunction/Description
<Alpha> Press <Alpha> to access upper case alpha characters and symbols on the
19-key keypad.
Numeric
Keys
<Fn>
<Power>
<Scan> Press <Scan> to activate the laser scanner.
4-Way
Rocker
Key
<Send/End> Used to initiate or end VOI P when VOIP software is installed.
In Normal mode, use the numeric keys to enter numbers. In Alpha mode
these keys can be used to type uppercase letters or punctuation.
Press <Fn> to enter the FN input state. Use FN mode to access additional
features and operations.
A customizable keypad overlay will be available for order, allowing you to
remap the Keypad to your specifications.
Press Power to put the Pegaso into sleep (suspend) mode if it is currently
running, and wake up (resume) the unit if it was in sleep mode. Press and
hold it briefly to turn off the unit.
Press the edge of the 4-way rocker key to move the cursor or highlighted text
entry during a menu/list selection. In a text window:
The <Up> arrow moves the cursor up one line.
<Right> arrow moves the cursor to the right one character.
The
<Down> arrow moves the cursor down one line.
The
The
<Left> arrow moves the cursor to the left one character.
System Tray Keyboard Indicators
The System Tray Keyboard Indicators are located at the bottom of the display.
The most recently activated state is to the left if more than one state is active.
Scroll between icons to view the active modes.
Table 4. Input States and their System Tray Indicators
Icon StateFunction
Press <Alpha> to enter uppercase alpha characters and symbols. When
Alpha
Mode
Fn Mode
Quick Reference Guide19
in Alpha mode, the current alpha character is displayed by a system tray
keyboard indicator.
Alpha mode is persistent, which means that the system stays in Alpha
mode until you press <Alpha> again.
Press <Fn> to enter FN mode. <Fn> is independent of the <Alpha> key.
Use FN mode to access the features and operations on the keypad.
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.