Datalogic Scanning DS1100 SH2347, DS2200 SH2348 User Manual

User’s / Programming Guide
Handheld Laser Bar Code Scanners
Keyboard Wedge /
Wand Emulation Interface
PSC Inc
959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC"). Owners of PSC products are hereby granted a non-exclu sive, revocable license to reproduce and transmit this documenta­tion for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your PSC representative. Electronic versions may either be downloadable from the PSC web site (www.psc.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other PSC publications, please let us know via the “Contact PSC” page.
Disclaimer
PSC has taken reasonable measures to provide information in this manual that is complete and accurate, however, PSC reserves the right to change any specification at any time without prior notice.
PSC is a registered trademark of PSC Inc. The PSC logo is a trade­mark of PSC. All other trademarks and trade names referred to herein are property of their respective owners.
-
-
Scanners discussed in this manual are covered by patents issues or pending in the U.S. and other countries.
NOTICE
The scanner is certified to be a Class II laser product with the United States Department of Health and Human Services Center for Devices and Radiological Health.
NOTICE
The scanner, as a component, has been tested for com­pliance with the EMI requirements of the United States Federal Communications Commission Part 15, Sub-Part J, Class A. Original equipment manufacturers (OEMs) are responsible for testing the scanner with their equipment to ensure system compliance with FCC requirements.
THIS APPARATUS COMPLIES WITH THE CLASS "A" LIMITS FOR RADIO INTERFERENCE AS SPECIFIED IN THE CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO INTERFERENCE REGULATIONS.
CET APPAREIL EST CONFORME AUX NORMES CLASS "A" D’INTERFERENCE RADIO TEL QUE SPECIFIER PAR LE MINIS TERE CANADIEN DES COMMUNICATIONS DANS LES REGLE­MENTS D’INTERFERENCE RADIO.
-
NOTES
Table of Contents
Introduction
Keyboard Wedge Mode ....................................................... 1
Serial Communications Mode .............................................. 1
AutoSense® Mode ............................................................... 1
Wand Emulation Mode......................................................... 1
Magnetic Stripe Reader ....................................................... 1
Unpacking
Installation
Keyboard Wedge 2
Cable Installation.................................................................. 2
Connecting the Power Supply.............................................. 3
Connecting a Magnetic Stripe Reader ................................. 3
Terminal Power-Up Sequence ............................................. 3
Serial Communications............................................................... 4
Serial TTL Mode................................................................... 4
Serial RS232 Mode .............................................................. 4
AutoSense® Operation............................................................... 5
Wand Emulation Operation ........................................................ 7
Setup Overview
Wedge Mode Options .......................................................... 8
Wand Emulation Options ..................................................... 8
Serial Communication and Wedge Options ......................... 9
Symbologies....................................................................... 10
Parameters Selection Guidelines
Examples ........................................................................... 11
Serial Communication .............................................................. 13
Reset Default ..................................................................... 13
Baud Rate .......................................................................... 13
Data Transmission ............................................................. 14
Communications Protocol .................................................. 16
Label Buffering ................................................................... 19
No Read Option ................................................................. 19
Menu Commands Parameter Messages............................ 20
External Trigger Operation................................................. 20
General Parameters
Intercharacter Delay........................................................... 21
Transmission Mode............................................................ 22
06656 i
System Status .................................................................... 22
Power Consumption ........................................................... 23
Laser Redundancy ............................................................. 23
Laser Timeout..................................................................... 24
Beeper Operation ............................................................... 24
Message Formatting
Prefixes and Suffixes 25
Prefix .................................................................................. 26
Suffix................................................................................... 26
Code Identifier .................................................................... 28
Preamble or Postamble Selection ...................................... 29
Preamble ............................................................................ 29
Postamble........................................................................... 29
Serial Commands
General Serial Command Format 31
ACK/NAK............................................................................ 31
Beeper Off CR-LF Ack........................................................ 32
Power Standby and Serial Commands............................... 33
Communication Parameter Changes ................................. 33
Manual Scanning Interaction .............................................. 33
Keyboard Wedge Parameters
Symbologies
UPC (A and E) ..........................................................................38
EAN/JAN................................................................................... 42
Code 39 ....................................................................................44
Code 2 of 5 – Interleaved ..........................................................46
Code 2 of 5 – Standard .............................................................47
Code 128 ..................................................................................48
MSI/Plessey .............................................................................. 50
Code 11 ....................................................................................50
Code 93 ....................................................................................51
16K............................................................................................ 52
Digit Selection ........................................................................... 53
Symbology Identifiers................................................................ 54
Wand Emulation Parameters
Select Code Type .....................................................................58
Bar Code Polarity ......................................................................58
Transmission Rate ....................................................................58
Data Synchronization ................................................................ 60
ii User’s / Programming Guide
Memory Module
Setup ........................................................................................ 63
Marker Beam ................................................................................. 64
Scanner Labeling
Service and Warranty......................................................... 66
Maintenance ............................................................................. 67
Cleaning ................................................................................... 67
Inspection ................................................................................. 67
Technical Support
PSC Website Support ............................................................... 68
PSC Website TekForum........................................................... 68
Reseller Technical Support ...................................................... 68
Telephone Technical Support ................................................... 68
Appendix A
Hexadecimal Conversion Table ......................................... 69
Hexadecimal Conversion Table ......................................... 70
Hexadecimal Conversion Table ......................................... 71
Primary Function Key Table............................................... 72
Secondary Function Key Tables ........................................ 73
Secondary Function Key Tables ........................................ 74
06656 iii
NOTES
iv User’s / Programming Guide

Introduction

Keyboard Wedge Mode

As a keyboard wedge interface, the PSC scanner can be used with ter­minals provided by most of the major terminal manufacturers. In most cases, the PSC scanner is easily connected between the key board and display of the terminal. The use of Preamble/Postamble, embedded keyboard function codes or keyboard function records allow operation of the terminal without manual entry from the key board. In this mode of operations, the PSC scanner draws power from the terminal.

Serial Communications Mode

The PSC scanner can be configured by the user for a serial communi­cation output. In this mode, the scanner can be connected to any device that accepts serial ASCII data at TTL voltage levels. RS232 voltage levels can be achieved by the use of an optional RS232 con version pod.

AutoSense® Mode

The PSC scanner may be configured at the factory with PSC’s AutoSense hands-free operation. When the scanner is placed in the stand, it becomes immediately active for reading any bar code label presented to it. The user can remove the scanner from the AutoSense and use it as a conventional hand-held scanner. When replaced in the stand, the scanner reverts automatically to AutoSense
®
feature. AutoSense® operates with a passive stand for
®
.
®
Stand
-
-
-

Wand Emulation Mode

The PSC scanner can be configured by the user for Wand Emulation. In this mode, the PSC scanner can be connected to any device that accepts a wand signal input. Wand Emulation communication pre sents bar code data to a host device exactly as a wand does. This pre­cludes the use of any option which adds information to the bar code symbol data (preamble, for example). A typical example of this would be to interface the scanner to a portable data terminal for remote data collection.
-

Magnetic Stripe Reader

Magnetic stripe reading capabilities are available with appropriate cabling.
06656 1

Unpacking

Your package should include a scanner, interface cable, User’s Man­ual, and a plastic scanner holder.
The unit should be inspected immediately upon receipt to determine if any damage has occurred during shipment. If damage has occurred, a claim should be filed with the carrier immediately.
Retain the shipping box, since it should be used to return the scanner to the factory for service.

Installation

Keyboard Wedge

In Keyboard Wedge mode the PSC scanner simulates keyboard key­strokes. Whether a person has pressed a key on the keyboard or data has been transmitted from the scanner is indistinguishable by the host device. When the PSC scanner is not transmitting data to the ter minal the keyboard operates as if the PSC scanner was not attached.
Installation of the PSC scanner should be completed by a user who is familiar with installing computer systems and cabling.

Cable Installation

1. Turn off power to the terminal to which the PSC scanner will be connected.
2. Verify that you received the correct cabling. The cable sup­plied for keyboard wedge installation is referred to as a “Y” cable.
-
3. Connect the modular plug to the PSC scanner. Insert plug into the rectangular opening in the bottom of the scanner handle.
4. Unplug the keyboard from the terminal and replug the key­board into the short leg of the “Y” cable that mates with it.
5. Plug the remaining long leg of the “Y” cable into the terminal where the keyboard was connected.
6. Arrange the fully connected unit so that all cables run freely.
2 User’s / Programming Guide

Connecting the Power Supply

If supplied, plug the connector from the external power supply into the receptacle located on the housing connector. Then plug the power supply into a power source.

Connecting a Magnetic Stripe Reader

If a detached Magnetic Stripe Reader (MSR) is to be used, plug the connector into the MSR receptacle located on the housing connector.

Terminal Power-Up Sequence

Turn on the power to the terminal to which the PSC scanner is con­nected. The unit will issue a series of beeps which are intentional and indicate that the terminal/keyboard power-on reset routines have been completed.
Programming for Terminal Type
If this is a first-time installation, it is NECESSARY to pro­gram the PSC scanner for use with the connected termi-
NOTE
Proceed as follows:
1. Using the Keyboard Wedge Parameters menu given in the
Keyboard Wedge Parameters Section scan:
nal.
WEDGE MODE ENABLE (CE)
This sets the PSC scanner into a Keyboard Wedge interface mode.
2. Select the terminal type by next scanning the appropriate
symbol for your terminal.
Scanning Reset to Default (ZA) will cause the PSC scan­ner to revert to Keyboard Wedge mode with a PC-AT termi-
NOTE
nal type.
06656 3

Serial Communications

The PSC scanner provides the user with two different serial commu­nications options: Serial TTL and Serial RS232 communications.

Serial TTL Mode

Serial TTL is a serial communications interface that uses TTL/CMOS voltage levels ranging from 0 to 5 volts. The user can select a nor mally high (default setting) or normally low (inverted) voltage levels. Serial TTL communications mode uses different cables than those used in keyboard wedge applications. To configure the PSC scanner in a Serial TTL mode, the user must have the appropriate cable with the correct signal pinouts in order to interface the scanner to the host terminal. To program the PSC for Serial TTL communications, the user must first identify the serial communications parameters sup ported by the host terminal. Typical parameters are the baud rate, parity and number of bits in the data word. These parameters are dis cussed in the section on Serial Communication Parameters. The PSC scanner has the added versatility to enable the user to select the qui escent voltage levels for interfacing with terminals that require inverted signals.

Serial RS232 Mode

The PSC scanner can also be used in an RS232 environment by con­verting the serial TTL voltage levels to RS232 voltage levels. For this installation, the user needs an optional cable, an adapter pod, and a power supply.
When the PSC scanner is operated with the RS232 adapter pod, the same serial communications parameters apply as those used in a serial TTL environment. The only difference is that the RS232 adapter pod inverts the polarity of all the signals passing through it. There fore, the user needs to program the scanner for serial communication, normal polarity (symbol CA). RS232 levels are available only in full continuous power mode.
-
-
-
-
-
4 User’s / Programming Guide

AutoSense® Operation

AutoSense® is a factory installed feature requested at time of order. It provides for hands-free or handheld operation. AutoSense
®
is acti­vated by scanning the Enable AutoSense® symbol. The scanner will respond by emitting a continuous, low level red beam of light known as the trigger beam. AutoSense
®
is deactivated by scanning the Dis-
able AutoSense® symbol.
When the AutoSense® feature is used with PSC’s AutoSense® stand (specifically designed for standard and HP scanners), the user must first attach the plastic scanner holder to the bracket of the stand as shown in Figure 1, next page. The scanner is then mounted into the holder. Insure that the trigger beam is aimed at the reflective tape affixed to the stand. AutoSense
®
is now ready to automatically scan bar code labels presented to it. When the trigger beam is broken by the bar code label, the scan beam will automatically engage and decode the bar code symbol. Any time the scan beam disappears, whether by a decode or by a scan beam timeout, the automatic trigger must be re-enabled by allowing the trigger beam to sense the reflec
-
tive tape.
While AutoSense® is activated, the user is able to remove the scanner from its holder and use it for handheld scanning operation. When the scanner is removed from the AutoSense
®
holder, the trigger beam will be broken and the scan beam will automatically be engaged. If the scanner does not decode a bar code symbol, the scanning beam will turn off after two to six seconds. Scanning is re-initiated by man ually pulling the trigger. When the scanner is replaced into the holder AutoSense
®
will be automatically re-engaged when the trigger beam
senses the reflective tape.
-
When the scanner is powered from a battery, such as in a hand-held terminal, AutoSense battery powered application, the user is strongly recom
®
should be disabled. In a
-
mended to use the power conservation feature of scan-
NOTE
ner operation. Power conservation reduces power draw from the battery between scans to extremely low levels. AutoSense
®
will function only in full power mode.
06656 5
NO Enable AutoSense
®
NN Disable AutoSense
®
To use this mode of operation properly, the user must first attach the plastic scanner holder to the bracket of the stand as shown in Figure 1. The (NO) Enable AutoSense® programming symbol is scanned until the green “Good Decode” light blinks. This will acti­vate the trigger screen. The scanner is then placed into the holder and the user must check that the red laser beam is aimed at the reflective label affixed to the stand. The AutoSense
®
is now ready to read labels
presented to it.
Figure 1. The PSC AutoSense® Stand
a. Riser sub-assembly d. Reflective tape b. Scanner holder e. Stand base c. Scanner
6 User’s / Programming Guide

Wand Emulation Operation

To operate the PSC scanner in Wand Emulation the user must first turn off the powerto the host device and then detach the scanner from the host device by removing the cable from the scanner.
The proper Wand Emulation cable must be connected between the scanner and the portable data terminal for remote data collection. If using an optional Smart Cable, the scanner automatically switches to Wand Emulation. Specific Wand Emulation parameters may still need to be set. If using a cable without Smart Cable switching, the user must then configure the scanner to its Wand Emulation mode by scanning the symbol CC.
CC Same Code Wand Emulation
This symbol activates the following default parameters:
Code Type = Same Code Wand Emulation
Code type, bar code polarity, and transmission rate can each be set for Wand Emulation. Menu symbols for these parameters are found in the section on Wand Emulation Parameters.
When the user with a Smart Cable again connects to the host device, the scanner will automatically revert to the original communication mode. Without Smart Cable, scan the appropriate programming symbol.
CE Enable Wedge
CA Enable Serial Mode
06656 7

Setup Overview

General setup parameters are divided into Keyboard Wedge options (communication to host through the terminal keyboard), Wand Emu lation options (communication between the scanner and the host sys­tem’s decoder), and Serial Communication options (communications direct to the host system).
Default options are denoted throughout the manual as follows:
— Keyboard Wedge @
— Wand Emulation #
— Serial Communication *

Wedge Mode Options

Several wedge mode options are available. Consult the Keyboard Wedge Parameters section for a complete list.

Wand Emulation Options

The available wand emulation options, listed below, are found in the section Wand Emulation Parameters.
Bar Code Polarity
Black High
White High
Transmitted Code Type
Same Code Wand Emulation
-
Converted to Code 39 (full ASCII)
Simulated Scan Rate
5 inches per second
10 inches per second
15 inches per second
20 inches per second
50 inches per second
70 inches per second
8 User’s / Programming Guide
Data Synchronization
Disable Data Synchronization
Enable Data Synchronization
Active Polarity High
•Active Polarity Low

Serial Communication and Wedge Options

The following communication options are used to define how your PSC scanner communicates with the host system through its serial interface or its keyboard wedge interface.
A message transmitted from the scanner upon a successful decode has the following format:
Prefix
Termi nal
ID
Preamble Code ID Data Po stamble Suffix
Some of these attributes, e.g., prefix, preamble, etc., may not be required or may vary from one host system to another. The parameter selection process allows you to tailor these elements for the particular requirements of your host system. You may also program an inter
­character delay to prevent data overrun problems with your host ter­minal.
Options specific to serial communications are:
Baud Rate Protocol
Parity Inverted Serial
Stop Bits External Trigger
Word Length Buffering Level
Each of these options is discussed in greater detail in the section on Serial Communication Parameters.
06656 9

Symbologies

The bar codes that can be read by PSC’s bar code scanners include:
Code 39 Code 93
Interleaved 2 of 5 Code 128
Standard 2 of 5 Codabar
UPC-A, UPC-E Code 11
EAN/JAN MSI/Plessey
A complete list of the related options and the instructions for setting them are provided in the section on Symbologies.
Scanning problems are most often caused by poor quality bar code symbols. If scanning problems arise, test your bar code system using the high quality bar code test symbols
NOTE
supplied in this manual or contact your PSC Customer Ser vice representative.
-
10 User’s / Programming Guide

Parameters Selection Guidelines

Three basic steps must be followed when selecting parameters for your scanner.
1. Review this manual to be sure you understand the terminology.
2. Review the requirements of your host system, with a techni­cal expert from your company, if necessary. This will enable you to determine if any of the factory default settings must be altered.
3. Enable or disable the relevant parameters by scanning the appropriate menus. This operation is described in more detail in the following example.

Examples

Assume that the beeper volume is too loud at its default setting. To change the beeper volume from its default value of loud to a setting of low, locate the beeper volume bar code menu in the General Parameters section. Then scan the label to the left of Beeper On, Vol ume Low. The correct label is reproduced below.
AB Beeper On; Volume Low
-
When enabling or disabling a parameter, be sure the scanner beam illuminates only one bar code symbol at a time. The layout of this manual minimizes accidental multiple-label
NOTE
A successful scan is indicated by two short-high beeps. An unsuc­cessful scan produces no beeps and requires you to rescan the Beeper On; Volume Low bar code.
Most parameters are modified in this way, and you may resume nor­mal bar code scanning when no further modifications are desired.
Some parameters require multiple scans to modify a setting; for example, Intercharacter Delay. If you wish to set this parameter to 5 milliseconds (msec.):
scanning.
06656 11
1. Scan the bar code beside Intercharacter Delay = XX and lis­ten for one short-high beep.
2. After the beep, scan the bar code beside 0 on the Digit Selec­tion page and listen for one short-high beep.
3. Still at the Digit Selection page, scan the bar code for 5 (the last argument in the command) and listen for two short beeps.
Your PSC scanner does not have a distinct programming mode. Instead, it automatically recognizes and reacts to the labels you scan. If, for example, you scan INTERCHARACTER DELAY = XX and then scan a normal data label, a normal tone is emitted in response to the data label, and the programming command is ignored. No special
exit code is required to resume normal operations.
12 User’s / Programming Guide

Serial Communication

Reset Default

To program the communication mode for serial asynchronous com­munication, scan the following label:
CA Select Serial Output

Baud Rate

There are seven standard serial communication baud rates to select from. Your scanner and the serial host computer must be set to the same baud rate. Select the correct rate.
DA Baud Rate = 300 Baud
DB Baud Rate = 600 Baud
DC Baud Rate = 1200 Baud
DD Baud Rate = 2400 Baud
DE Baud Rate = 4800 Baud
DF Baud Rate = 9600 Baud *
DG Baud Rate = 19200 Baud
06656 13

Data Transmission

Serial transmission data is composed of three of four different ele­ments, depending upon host system requirements. These elements are the START bit, DATA bits (7 or 8 bits), OPTIONAL PARITY bits, and STOP bit (s) (1 or 2 bits).
The PARITY bit is used for error detection (e.g., data altered in trans­mission), but is not required by all systems. A parity bit, if required, will be in one of the following four formats:
If your system requires a WORD length of 7 bits, one or two STOP bits, and a PARITY check, select the appropriate option from Table 1.
Table 1. 7 Bit Options
Data
7 1 Odd
7 1 Even
7 1 Mark
7 1 Space
7 2 Odd
Stop
Bits
Parity Option
ED
EC
EB
EA*
EH
7 2 Even
EG
14 User’s / Programming Guide
Table 1. 7 Bit Options
Data
7 2 Mark
7 2 Space
If your system requires a WORD length of 8 bits, 1 or 2 STOP bits, and PARITY check, select the appropriate option from the table below:
Stop
Bits
Parity Option
EF
EE
Table 2. 8 Bit Options
Data
8 1 Odd
Stop
Bits
Parity Option
EL
8 1 Even
8 1 Mark
8 1 Space
EK
EJ
EI
06656 15
If your system requires a WORD length of 8 bits and 1 or 2 STOP bits, but no PARITY, select the option below:
Table 3. 8 Bit, No Parity
8 1 None
8 2
PARITY check is not possible with this combination of STOP bits and WORD length.
Some receiving equipment requires inverted serial communication signals.
CD Inverted Serial Communications
EM
EN

Communications Protocol

XON/XOFF
Protocol controls data flow between your PSC scanner and a serial host computer. If Protocol = XON/XOFF is selected, the scanner rec ognizes the ASCII XON/XOFF characters. The host may then stop transmission with XOFF and resume with XON.
Controlled data flow is achieved between devices when the receiving device sends ASCII XON/XOFF codes to the transmitting device. In other words, when the receiving device is unable to accept data, it sends on XOFF code to inform the host to temporarily suspend data transmission.
When the receiving device “catches up,” it sends an XON code to inform the host that it is again ready to accept data. An advantage of this protocol is that additional hardware is not required for imple mentation; only transmit, receive, and signal ground are required.
-
-
16 User’s / Programming Guide
CTS
Like XON/XOFF protocol, CTS protocol is a mechanism used to con­trol data flow out. The CTS input is used to inform the scanner that the host terminal is ready to accept scanned data. When CTS (+) pro tocol is selected, the scanner waits for a low level on its CTS input before transmitting data. When CTS (-) is selected, the signal polari ties are reversed and a high level indicates data may be transmitted. The CTS protocol may be programmed independently of the RTS pro tocol; however, the signal polarities must be the same. You may not select CTS (+) and RTS (-).
RTS
The RTS output from the scanner may be programmed to operate in one of three different modes. In the default mode RTS signals when the scanner is ready to receive commands or data. In the second mode, RTS is in a fixed state. In the third mode, RTS signals when the scanner has data to transmit. The RTS modes are independent of the CTS protocol. However, you must select the same active state for RTS as for CTS. You may not select CTS (-) and RTS fixed low. If CTS (-) is selected, then the active state for RTS will be high.
The specified levels are at the modular connector and are inverted when using an RS232 converter pod.
NOTE
-
-
-
CTS Protocol = None*
HA
HB Protocol = XON/XOFF
HC Protocol = CTS (-)
RTS low indicates scanner ready to receive data
06656 17
HD Protocol = CTS (+)
HG RTS always low
HH RTS always high
HI
HJ
HK
Another flow control option is available. If enabled, the stop/go pro­tocol disables the trigger after every successful scan. The trigger is then re-enabled with a serial ‘BG’ command in format <STX><ESC>BG<ETX>.
BS Disable Stop/Go Protocol*
BT Enable Stop/Go Protocol
RTS high indicates scanner ready to receive data
RTS low indicates scanner has data to transmit
RTS high indicates scanner has data to transmit
18 User’s / Programming Guide

Label Buffering

The user may select one of three levels of serial buffering. With Full Buffering (the default) selected, the scanner will place all scanned labels into a buffer for transmission. This allows the operator to con tinue scanning even though the previous label may not have been transmitted yet. Scanning will continue normally until the buffer is full, then scanning will stop. Scanning will continue when enough space is available for the current label.
When No Buffering is selected then scanning will be stopped until the current label is completely transmitted.
When One Label Buffering is selected the scanner will allow the oper­ator to scan one more label in addition to the label already in the transmit buffer. In other words, one label may be scanned beyond the label being transmitted.
NE Full Buffering
NF No Buffering
-
NG One Label Buffering

No Read Option

The scanner can be programmed to send a no read message (‘NR’) upon a scan that does not result in a good read.
NX Enable No Read
NY Disable No Read *
06656 19

Menu Commands Parameter Messages

In serial mode, most menu commands when scanned will provide a confirmation message to the host along with the ACK. This feature can be enabled or disabled.
BA Enable Parameter Messages *
BB Disable Parameter Messages

External Trigger Operation

External trigger operation enables an external device to control scan­ning. External trigger is controlled by applying an external trigger signal to the CTS input (with external triggering enabled). When active, this signal causes scanning to begin just as if the scanner’s trig ger were depressed. Scanning continue until a label is decoded or the external trigger signal is deactivated.
In the event of a decode, the trigger signal must be deactivated for a minimum of 50 milliseconds before another scan can be attempted (“tying” the trigger signal active does not cause continuous scanning and decoding).
When EXTERNAL TRIGGER(+) is scanned, scanning begins when a high level input is applied to the CTS input. Conversely, when EXTERNAL TRIGGER(-) is scanned, scanning begins when a low level is applied to CTS. When CTS is not connected, it is treated as if a high level is applied. The voltage levels given are at the modular con nector. If an RS232 converter pod is used, then the levels are inverted.
-
-
HA Disable External Trigger#*@
HE External Trigger(+)
20 User’s / Programming Guide
HF External Trigger(-)

General Parameters

Intercharacter Delay

Certain terminals and computers require an intercharacter delay to simulate the effects of keystroke delays. Choosing an intercharacter delay causes the characters to be sent at the slower speed required by the device to which you are interfacing.
GA No Intercharacter Delay
To set Intercharacter Delay to other then zero, scan the label below and then scan two separate digits from the
NOTE
GB Intercharacter Delay = XXMEC
Digit Selection page (99 maximum).
Intercharacter delay cannot exceed 99 milliseconds.
NOTE
Interlabel delay allows user to program a delay between transmitted labels.
GC No interlabel delay *@
GD Set interlabel delay 0-9.9 seconds
06656 21

Transmission Mode

Full Duplex or Half Duplex
This section pertains only to models with a Liquid Crys­tal Display (LCD)
NOTE
Transmission mode selects either full or half duplex operation regard­less of interface. In the half duplex mode, the decoded message is sent simultaneously to the display and to the host computer. In the full duplex mode, the message is sent to the host computer. In send mode, the host always has the capability to send a message directly to the LCD.
The advantage of the full duplex mode is that the display shows the message received by the host. In the half duplex mode you can see that the message has been sent but there is no confirmation that it was received. The disadvantage of the full duplex mode is simply that the host computer must be programmed to relay the message back to the scanner.
NA Transmission Mode = Full Duplex
NB Transmission Mode = Half Duplex *#
For models which do not have an LCD, parameter selec­tions NA and NB have no effect.
NOTE

System Status

To examine the configuration of your system, scan the appropriate option.
When Option ZB is scanned, a list of currently programmed parame­ters is sent to the display device. Scanning ZB may interfere with your
terminal software, depending on your application.
22 User’s / Programming Guide
ZB Display Configuration
When Option ZC is scanned, the program version followed by car­riage return-line feed characters (CR-LF) is sent in the format <software name>SP<###> (WDHB 3.86, for example).
ZC Transmit Version Number

Power Consumption

You may choose one of two Power Consumption modes. Option @A supplies full power to the scanner at all times; Option @B allows the unit to revert to a standby mode after a successful read. This mode is a power conservation feature.
@A Enable Continuous@ Full Power
@B Enable Standby *#

Laser Redundancy

For a successful decode to occur when Laser Redundancy is enabled, two laser scans of the bar code must match. Because the laser scans a label many times a second, you will notice little or no change in the speed of the decode. Laser redundancy can be used to enhance the security of the bar code reader.
BC Disable Laser Redundancy *#@
BD Enable 2 Times Laser Redundancy
06656 23
BE Enable 4 Times Laser Redundancy

Laser Timeout

The scan beam will activate in response to a trigger pull. The beam will automatically deactivate after a label is decoded. If a label is not decoded., the scan beam will timeout and deactivate after several sec onds. Scan the following labels to control the length of the timeout.
-
BH
BI
BJ
BO
BW
Set Scan Beam *#@ Timeout to 6 Seconds
Set Scan Beam Timeout to 4 Seconds
Set Scan Beam Timeout to 2 Seconds
Set Scan Beam Timeout to 1 Second
Set Scan Beam Timeout to ½ Second

Beeper Operation

Scan one of the options below to modify beeper operation.
AA Beeper Off
AB Beeper On; Volume Low
24 User’s / Programming Guide
AC Beeper On; Volume Medium
AD Beeper On; Volume Loud *#@

Message Formatting

Message formatting describes how to format the data (decoded string) that is sent from the scanner to the host.
The programmable options DO NOT apply in Wand Emu­lation.
NOTE

Prefixes and Suffixes

Prefix Terminal ID Preamble Code ID Data Postamble Suffix
Prefixes, Suffixes, Preambles and Postambles are programmable attributes that are transmitted along with the decoded label data to the host device. These attributes are handled differently whether the scanner is configured for serial mode or wedge mode. When config ured for wedge mode these attributes are sent as keystrokes. The scanner automatically translates the ASCII characters into keystrokes before sending data to the host. Refer to the keystroke translation tables for non-printable ASCII characters.
-
06656 25

Prefix

A prefix is a subset of the preamble normally formatted to some industry standard, i.e., it is represented by a specific ASCII code. An example of a prefix is the STX (Start of Transmission) code.
IA Prefix = None*#
IB Prefix = STX
IC Prefix = SOH

Suffix

A suffix is a subset of the Postamble. Like the prefix, it is normally assigned a specific ASCII code. Examples of suffixes are CR (Carriage Return) and LF (Line Feed).
MA Suffix = None #
MB Suffix = ETX
MC Suffix = CR
MD Suffix = LF
ME Suffix = HT
26 User’s / Programming Guide
MF Suffix = CR and LF *
Users also have the ability to select any ASCII character for use as a suffix.
Scan the MJ label, then scan two labels from the Hexadecimal Con­version Table representing the character needed for the suffix.
MJ
Certain specialized applications require a two character suffix of ETB NUL. Scanning MI provides this.
MI Select Suffix = ETB NUL
Terminal ID
Terminal ID characters are used to identify individual scanners when more than one scanner is interfaced with the host system. Options available are none (DISABLED) or digits 01 through 99.
JA ID Character = Disabled*#
If you scan the label below, you must also scan two of the digits from the Digit Selection page.
NOTE
Select Programmable Suffix Character
JB ID Character = XX
06656 27

Code Identifier

A code identifier may optionally be transmitted with the message. This option is provided so a host computer can identify the type of bar code scanned, as well as the encoded information.
Scan Option FA to disable the code identifier.
FA Disable Code ID # *
Scan Option FB to enable the code identifier.
FB Enable Code ID
The table below shows the default code-identifier character assign­ments. These can be changed using the procedure found in the Sym­bology Identifier Section.
Table 4. Code Identifier Characters
SYMBOLOGY CODE IDENTIFIER
Code 39 a
Code Interleaved 2 of 5 b
Code Standard 2 of 5 c
UPC/EAN/JAN d
Code 128 f
Codabar h
28 User’s / Programming Guide

Preamble or Postamble Selection

Preambles and Postambles are composed of up to four ASCII charac­ters. Each ASCII character is encoded as two hexadecimal numbers. Use the Hexadecimal Conversion Table in Appendix A to look up the hexadecimal equivalent.
If you select a Preamble or a Postamble you must scan four ASCII characters, even if the Preamble or Postamble is less than four characters in length. This is done by
NOTE
scanning in null (NUL) characters for the additional char acters. For example, if your Preamble is “AB” (in ASCII code), scan A, then B, then two null characters, or 4,1, 4,2 0,0 0,0 hexadecimal.
-

Preamble

A Preamble is a string of characters that prefixes a message that is transmitted to the host. The sequence and number of characters in a Preamble is determined by the type of host system. Although not all systems require a Preamble, those which do will only receive mes sages with the correct Preamble. The maximum preamble length is four characters.
KA Preamble = None*#
-
KB Enter Preamble
IMPORTANT Scan Enter Preamble to enter a Preamble, then refer to the Hexadecimal Table in Appendix A.

Postamble

A Postamble is similar to a Preamble, except that it appended to the message which is transmitted to the host. Its maximum length is also four characters.
06656 29
LA Postamble = None*#
LB Enter Postamble
IMPORTANT
Scan Enter Postamble to enter a Postamble, then refer to the Hexadecimal Tabl e i n
Appendix A.
30 User’s / Programming Guide

Serial Commands

General Serial Command Format

Serial Commands are only accepted by the PSC scanner when in serial communications mode.
Serial commands take the form: STX ESC LT1 LT2 <optional param-
eters>ETX (Note: STX = ^B; ETX = ^C)
STX, ESC, and ETX are ASCII codes whose values are 02H, 1BH, and 03H, respectively. LT1 and LT2 are uppercase ASCII letters (commer cial A and @ are the same as those printed in earlier sections of this manual under their corresponding menu bar code labels). The ESC code that follows the STX code identifies this as a command. Some commands require parameters such as minimum and maximum code lengths, and strings of hexadecimal characters. When parameters are required by the command, they immediately follow LT2. There are never spaces within serial commands.

ACK/NAK

The scanner provides ACK/NAK protocol during serial program­ming in order to provide feedback to the host computer which is pro­gramming the scanner.
ACK/NAK protocol provides two vital functions. First, it provides the host with positive acknowledgment that its commands are being accepted and acted upon. Second, and perhaps more important, it ensures that the host will not issue commands to the scanner more quickly than the scanner can process them. For example, every time the scanner receives a correct command, it modifies its internal EEPROM, a function that takes about one second. At 9600 baud, the host can easily issue commands to the scanner faster than they can be processed. If after issuing each command the host waits to receive an ACK or NAK code before issuing the next command, the scanner cannot be overrun. If XON/XOFF or CTS/RTS Protocol is being used, the scanner cannot be overrun by programming commands. How ever, the host is not provided with feedback as to the outcome of its commands.
-
-
The ACK/NAK protocol is quite simple. Whenever the scanner receives a correctly formatted command, it sends a confirmation mes sage followed by an ACK (06H) code.
06656 31
-

Beeper Off CR-LF Ack

If the scanner receives an unknown or improperly formatted code, or if the required parameters are missing or out-of-range, it sends a NAK (15H) Code.
Command Function
STX ESC PC ETX Enable I 2 of 5 with check digit
STX ESC PD12 ETX Set I 2 of 5 minimum length to 12
STX ESC PE14 ETX Set I 2 of 5 maximum length to 12
STX ESC KB31323334 ETX Set Preamble to ‘1234’
STX ESC LB61626364 Set Postamble to ‘abcd’
Serial Commands to Use with Caution
Some of the commands in this manual should not be used as serial commands because of the consequences they produce. All PSC scan ners use the same hardware components to implement both serial communication and wand emulation. This means that all serial com munication functions are disabled during wand emulation, and vice versa. Because of this, issuing any of the commands in Table 5 causes the scanner to enter its Wand Emulation mode, thereby disabling serial communication.
-
-
CB Wand Emulation, Code 39 Output
CC Wand Emulation, Same Code Output
Furthermore, because the scanner acts upon a command and then sends ACK or NAK, neither or these codes will be transmitted in response to any of the above commands. In Table 5 only the com mand letters are listed; the complete command is prefixed with STX ESC, and suffixed with ETX. Because it is not possible to set (via serial command) two Wand Emulation parameters (emulation speed and polarity, for example), scanners to be used in Wand Emulation envi ronments must be programmed by scanning labels from this manual.
-
-
32 User’s / Programming Guide

Power Standby and Serial Commands

When the scanner is programmed for standby power operation (@B), the first character of the command is used to “wake-up” the scanner; it is not properly received by the scanner’s CPU. Therefore, when there is any possibility that the scanner is in standby mode, an extra space code should be transmitted before STX to ensure the scanner is “awake” before sending commands to it. If the scanner is not being operated in standby mode, the space has no effect on commands (space prefixed commands are properly decoded). Having sent the space code to “wake-up” the scanner, a 150 to 200 millisecond pause must be observed to allow the scanner’s CPU to complete its initial ization tasks, during which time it is unable to accept serial com­mands before issuing the programming command. Failure to observe this delay causes the scanner to ignore the incoming command.
-

Communication Parameter Changes

All commands which affect serial communication are acted upon immediately. Therefore, when changing communication parameters (baud rate, word length, parity, etc.), the scanner will send the ACK Code, using the newly implemented communication parameters. There should be enough of a delay from the issuance of a communi cation parameter setup command for the properly programmed host computer to modify its internal parameters and correctly receive the ACK code sent by the scanner. This is due to the internal, one second delay required for the scanner to update its internal EEPROM.
-

Manual Scanning Interaction

The decoder firmware makes no attempt to resolve conflicts between serial programming commands and manually scanned menu labels. If you plan to scan menu labels from the PSC Operator’s Manual, do not attempt serial programming, and vice versa. Serial commands are given priority over pending menu labels. For example, if you scan the menu label SET I 2 of 5 MINIMUM LENGTH and the scanner is wait ing for a two-digit, minimum length code when a serial command is issued, the serial command is acted upon and the pending manual command SET I 2 of 5 MINIMUM LENGTH is ignored.
06656 33
-

Keyboard Wedge Parameters

Scan symbol CE to enable Keyboard Wedge mode. Next, select a ter­minal type by scanning the symbol CF for IBM PC-AT or PS/2 mod­els 50/60/80; or symbol CG for PC-XT type terminals. Alternatively, you may scan just CF or CG to enable wedge mode and select a termi nal type.
CE Wedge Mode Enable @
-
ZA
CF
CG PC-XT – U.S.A.
CH IBM 3151 – U.S.A.
CI DEC VT220 – U.S.A.
CN Macintosh
Reset to Wedge Default
Values
PC-AT, PS/2 and 50/60/80@ — U.S.A.
CP IBM 3477 – U.S.A.
34 User’s / Programming Guide
CT IBM 319X – U.S.A.
CY PS/2 Mode 57/25 — U.S.A.
C6 Unisys B-26
C8 Link 125
CV PC-AT German Keyboard
CW PC-AT French Keyboard
CX PC-AT UK Keyboard
\B PC-AT Belgian Keyboard
\C PC-AT Swiss Keyboard
\D PC-AT Danish Keyboard
06656 35
\E PC-AT Italian Keyboard
\F PC-AT Spanish Keyboard
\G PC-AT Swedish Keyboard
\H PC-AT Portuguese Keyboard
\L
\M
In normal Wedge Mode, the scanner emulates the keyboard exactly. Should a scanned bar code label have alphabetic characters, they will be presented to the computer as if they had been typed at the key board. They will be affected by the Caps Lock key. If the scanned label has lower case alphabetic characters AND the Caps Lock key in ON, then the alphabetics will be presented as upper case.
With the Caps Lock key ON, the user may required that the scanned alphabetics are presented to the computer exactly as they are encoded in the label. This is accomplished by scanning EO – Shift Alphabetic Characters.
DEC VT 220/320/420 German Keyboard
DEC VT 220/320/420 French Keyboard
-
36 User’s / Programming Guide
EO Shift Alphabetic Characters
EP Normal Alphabetic Characters*
In some models of scanner, the wedge output is capable of two types. To enable primary or secondary keyboard
NOTE
CQ Enable Primary Keyboard@
CR Enable Secondary Keyboard
NOTE
modes, scan one of the next two labels.
In Wedge Mode, non-printable ASCII characters (00-31H) do not allow for an obvious translation to keycodes. There are two approaches to this issue – they are explained in Appendix A.
@Q
@R
See Appendix A.
NOTE
Enable Primary Function Key Tab le@
Enable Secondary Function Key Tab le
06656 37

Symbologies

The PSC scanner is configured with Code 39, Code 128, UPC-A and UPC-E not expanded symbologies. The user has the ability to enable or disable any of the symbologies given below as well as UPC or EAN supplements, I 2 of 5 with check digit, and Code 39 modulo 43 check digit.
The bar codes that can be read by PSC’s bar code scanners include:
Code 39 Code 93
Interleaved 2 of 5 Code 128
Standard 2 of 5 Codabar
UPC-A, UPC-E Code 11
EAN/JAN MSI/Plessey
The minimum label lengths are set to 1 character, except Code I 2 of 5, which is set to 14 characters; andCode S 2 of 5, which is set to 4 characters. The maximum label length for all symbologies is set to 32 characters. The user has the ability to set the minimum and maxi mum label lengths.
The symbol * indicates Default Parameter for serial mode. The sym­bol # indicates Default Parameters for Wand Emulation. The symbol @ indicates default parameters for Wedge Mode.
-
It is recommended that the user disable those symbolo­gies and parameters that are not being used.
NOTE

UPC (A and E)

Scan Option QA to disable all UPC labels.
QA Disable UPC (both A and E)
38 User’s / Programming Guide
Option QB or Option QC enable both UPC-A and UPC-E. If UPC is enabled, any UPC label, with or without supplement, is read. The supplement is read if Option QB is selected, and it is ignored if Option QC is selected.
QB
QC
Expanded UPC-E is disabled by scanning Option QH, or is enabled by scanning Option QI.
QH Disable Expanded UPC-E *#@
QI Enable Expanded UPC-E
Transmission of the first character in a UPC symbol (the number sys­tem character) is disabled by scanning Option QD or enabled by scanning Option QE.
QD
Enable UPC with 2 or 5 Digit Supplement Enabled
Enable UPC with 2 or 5 Digit Supplement Disabled *#@
Disable Transmission of Number System Digit
QE
Enable Transmission of Number System Digit *#@
06656 39
Transmission of the last character in a UPC symbol (the check digit) is disabled by scanning Option QF, or is enabled by scanning Option QG.
QF
QG
Scanning QJ causes UPC-A labels to be transmitted as EAN-13 labels. Scanning QK disables this feature.
QJ Enable UPC to EAN Translation
QK
QN
Disable Transmission of Check Digit
Enable Transmission of Check Digit *#
Disable UPC to EAN Translation *#@
Disable second beep on Supplement decoded *
QO
QP
QR
Enable second beep on Supplement decoded
Set supplement retry count (16 by default) range = 1-32
Disable transmissionof UPC-E check digit
40 User’s / Programming Guide
QS
Enable transmissionof UPC-E check digit*
QT
QU
QV Disable UPC-E*
QW
QX
Q0 Disable mandatory supplements*
Disable transmission of UPC-E number system digit
Enable transmission of UPC-E number system digit
Enable UPC-E independently with supplement
Enable UPC-E independently without supplement*
Q1 Enable mandatory supplements
QA to QG apply to UPC-A and UPC-E.
NOTE
06656 41

EAN/JAN

Scan Option RA to disable EAN/JAN (8 or 13 digit).
RA Disable EAN/JAN (8 or 13 Digit) #@
Option RB or RC enables both EAN 8 digit and EAN 13 digit. If EAN/JAN is enabled, any EAN/JAN label, with or without supple ment, is read. The supplement is read if Option RB is selected and is ignored if Option RC is selected.
-
RB
RC
Transmission of the first character in an EAN/JAN symbol (the num­ber system character) is disabled by scanning Option RD, or is enabled by scanning Option RE.
RD
RE
Enable EAN/JAN with 2 or 5 Digit Supplement enabled
Enable EAN/JAN with 2 or 5 Digit *Supplement disabled
Disable Transmission of Number System Digit
Enable Transmission of Number System Digit *#@
42 User’s / Programming Guide
Transmission of the last character in an EAN/JAN symbol (the check digit) is disabled by scanning Option RF, or is enabled by scanning Option RG.
RF
RG
RJ
RK
RL
RM
Disable Transmission of Check Digit
Enable Transmission of Check Digit *#@
Disable EAN-8 Transmission of check character
Enable EAN-8 Transmission of check character*
Disable EAN-8 Transmission of number system digit
Enable EAN-8 Transmission of number system digit*
RN Disable EAN-8 independently*
RO
RP
Enable EAN-8 independently with supplement
Enable EAN-8 independently without supplement
06656 43
RQ
Disable EAN-8 special 5 character (0’s) preamble
RR
RA to RG apply to both EAN-13 and EAN-8.
NOTE
Enable EAN-8 special 5 character (0’s) preamble

Code 39

To disable Code 39, scan Option OA.
OA Disable Code 39
To enable Code 39, scan Option OB or OC. After enabling Code 39, make any additional required selections from Options OD through OG.
OB Enable St6andard Code 39*#@
OC Enable Full ASCII Code 39
OD
OE Enable Modulo 43 Check Character
Disable Modulo 43 Check
Character*#@
44 User’s / Programming Guide
The minimum length of Code 39 messages is set by scanning Option OH, followed by scanning two digits (01-32) from the Digit Selection page.
OH
The maximum length of Code 39 messages is set by scanning Option OI, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
OI
The START and STOP characters in code 39 may either be transmitted or suppressed. Scan Option OF to suppress transmission of the START and STOP characters. Scan Option OG to enable transmission.
OF Do Not XMIT START and STOP*#@
OG Transmit START and STOP
Minimum Length (specified by two digits 01-32)
Maximum Length (specified by two digits 01-32)
The following are only valid if CHK CHAR is enabled.
OJ
OK
Enable Transmission of Code 39 Modulo 43 Check Character
Disable Transmission of Code 39 Modulo 43 Check Character *
06656 45
Code 2 of 5 – Interleaved
Scan Option PA to disable Interleaved Code 2 of 5.
PA Disable Interleaved Code 2 of 5*#@
Scan Option PB or PC to enable Interleaved Code 2 of 5.
PB
PC
The minimum length of Interleaved 2 of 5 messages is set by scanning Option PD, followed by scanning two digits (02-32) from the Digit Selection page. The value of the number you scan must be even.
PD
The maximum length of Interleaved Code 2 of 5 is set by scanning Option PE, followed by scanning two digits (02-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers.
Enable Interleaved 2 of 5 without Check Digit
Enable Interleaved 2 of 5 with Check Digit
Minimum Length I 2 of 5 (specified by two digits 02-32)
PE
Maximum Length I 2 of 5 (specified by two digits 02-32)
46 User’s / Programming Guide
Code 2 of 5 – Standard
Scan Option PF to disable Standard Code 2 of 5.
PF Disable Standard Code 2 of 5 *#@
Scan Option PG to enable Standard Code 2 of 5.
PG Enable Standard 2 of 5
The minimum length of Standard 2 of 5 messages is set by scanning Option PH, followed by scanning two digits (01-32) from the Digit Selection page.
PH
The maximum length is set by scanning Option PI, followed by scan­ning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers.
PI Maximum Length S 2 of 5
The following are only valid if CHK CHAR is enabled.
PO Disable I 2/5 check character
PP Enable I 2/5 check character
Minimum Length S 2 of 5 (specified by two digits 01-32)
06656 47

Code 128

Scan Option TA to disable Code 128.
TA Disable Code 128
Scan Option TB to enable Code 128.
TB Enable Code 128 *#@
The minimum length of Code 128 messages is set by scanning Option TC, followed by scanning two digits (01-32) from the Digit Selection page.
TC
The maximum length of Code 128 messages is set by scanning Option TD, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
TD
Scan Option VA to disable Codabar.
VA Disable Codabar *#@
Scan Option VB to enable Codabar.
VB Enable Codabar
Minimum Length (specified by two digits 01-32)
Maximum Length (specified by two digits 01-32) Codabar
48 User’s / Programming Guide
The minimum length of Codabar messages is set by scanning Option VE, followed by scanning two digits (01-32) from the Digit Selection page.
VE
The maximum length of Codabar messages is set by scanning Option VF, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
VF
The transmission of the STOP/START Characters is enabled by scan­ning Option VD, or is suppressed by scanning Option VC.
VC
VD
Minimum Length (specified by two digits 01-32)
Maximum Length (specified by two digits 0-32)
Disable Transmission *#@ of START/STOP character
Enable Transmission of START/ STOP Character
06656 49

MSI/Plessey

Previous customization of other scanner features may have made MSI/Plessey unavailable in some scanners. Consult Customer Ser vice for current capabilities or if you require a specific symbology.
PK Enable MSI/PLESSEY
-
PL
PM
PJ Disable MSI/PLESSEY
Set Minimum Length, then scan two digits: 01-14 (see Digit Selection).
Set Maximum Length, then scan two digits: 01-14 (see Digit Selection).

Code 11

Previous customization of other scanner features may have made Code 11 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.
SB
Enable Code 11 with one check digit
SC
Enable Code 11 with two check digits
50 User’s / Programming Guide
SF
Set Minimum Length, specified by two digits 01-32
SG
SE
SD
SA Disable Code 11
Set Maximum Length, specified by two digits 01-32
Enable transmission of check digits
Disable transmission of check digits

Code 93

Previous customization of other scanner features may have made Code 93 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.
UB Enable Code 93
UC Standard Code 93
06656 51
UD Enable Full ASCII Code 93
UE
UA Disable Code 93
Set Minimum Length, specified by two digits 0-1-32
16K
TF Enable 16K Code
TE Disable 16K Code
52 User’s / Programming Guide

Digit Selection

5
0
1
2
3
6
7
8
9
4
06656 53

Symbology Identifiers

Your PSC scanner can be programmed to add and/or change symbol­ogy identifiers which might be required to be transmitted with mes­sages. This feature is provided to allow a host computer to recognize the type of bar code scanned, as well as the uncoded information. The symbology identifiers are selected by scanning the desired program ming bar code symbol as defined below.
SYMBOL FUNCTION
-
FA
FB
FE Set UPC-A Symbology Identifier
FF Set UPC-E Symbology Identifier
FG Set EAN-8 Symbology Identifier
FH Set EAN-13 Symbology Identifier
Disable Transmission of Symbology Identifiers*
Enable Transmission of Symbology Identifiers
FI Set Code 128 Symbology Identifier
54 User’s / Programming Guide
FJ Set Code 39 Symbology Identifier
FK Set I 2/5 Symbology Identifier
FL Set S 2/5 Symbology Identifier
FM Set Code 11 Symbology Identifier
FN Set Code 93 Symbology Identifier
FO Set Codabar Symbology Identifier
FP
To change any single symbology identifier, scan the appropriate sym­bology identifier bar code symbol and then scan the four hexadecimal characters that represent the two bytes of the identifier. If you select a one character identifier, then scan zero (null) twice for the second character.
Set MSI/Plessey Symbology Identifier
06656 55
To find the hexadecimal values for the characters turn to the Hexa­decimal Conversion Table. The procedure for selecting a symbology identifier is identical to the procedure for selecting Preambles and Postambles. The similar difference is that symbology identifiers are a maximum of two characters, not four.
Scanning the ZA (Result to Default) programming symbol will set all symbology identifiers back to PSC defaults as given in Table I and disable the transmission of the sym
NOTE
The FC programming symbol selects the symbology identifiers for use with ICL 9518/9520 cash registers.
FC Programming Symbol
The FD programming symbol selects the symbology identifiers for use with ICL 9518/9520 cash registers as given in
FD Programming Symbol
bology identifiers.
Tabl e 5.
-
56 User’s / Programming Guide
Table 5. Symbology Identifiers
Symbology
UPC-A
UPC-E
EAN-8
EAN-13
Code 128
Code 39
Interleaved 2/5
Standard 2/5
Code 11
Code 93
Codabar (NW7)
MSI/Plessey
ZA-PSC
Default
PC-ICL 9518 CCD
d A A
d E C
d FF B
d F A
f I Y
a I Y
b I Z
c I Y
e I Y
g I Y
h I X
p I Y
06656 57

Wand Emulation Parameters

Select Code Type

Scan Option CC if you intend to operate the scanner in Same Code Wand Emulation mode. If you want the label to be transmitted in Code 39 scan Option CB.
CC Same Code Wand # Emulation
CB
Wand Emulation (Code 39, Full ASCII)

Bar Code Polarity

Selected Option WA or WB.
WA Black High#
WB White High
WC Black High, Quiescent High

Transmission Rate

Select the fastest speed your decoder will accept for best overall per­formance by scanning one of the following labels.
YA 5 inches per second
58 User’s / Programming Guide
YB 10 inches per second#
YC 15 inches per second
YD 20 inches per second
YE 30 inches per second
YF 50 inches per second
YG 70 inches per second
06656 59

Data Synchronization

Your PSC scanner can be prepared to synchronize the transmission of scanned data to the timing sequence some terminals require to prop erly receive the data. This relationship is diagrammed in Figure 2.
Figure 2. Timing Sequence Diagram
-
Data Transmission
(ta)
Data Synchronization
Setup Time (ts) 200 ms - 220 ms
Hold Time (th) 0 ms - 10 ms
RTS output is used for the data synchronization signal. Scan XD to enable the data synchronization signal. Scan Option XC to disable Data Synchronization.
XC Disable Data # Synchronization
data white space
Active
(th)
XD Enable Data Synchronization
Polarity may be selected as either active high or low by scanning XE (high) or XF (low).
60 User’s / Programming Guide
XE Active # Polarity High
XF Active Polarity Low
06656 61

Memory Module

The Memory Module option is a factory installed feature that is requested at time of order. The Memory Module option allows the 5300 series scanner to store decoded labels in an internal battery backed up RAM. The stored buffered labels can then be transmitted some time later. The user may also choose an interlabel transmission delay in cases where the transmission rate of the buffered decoded label is faster than the receiving equipment.
Switching to the Memory Module mode is achieved by scanning the Enable Memory Module symbol. The Memory Module is cleared every time Memory Module is enabled. While in Memory Module mode, the scanner will store in its internal memory all scanned bar code labels.
The user can transmit the stored labels by scanning the Send Memory Module symbol. When the transmission rate is faster than the receiv ing equipment, the user can program a delay that will occur after each label. The delay is programmed by scanning the Interlabel Delay symbol (see the Intercharacter Delay page of the Setup Parameters section), followed by two digits (see Digit Selection page) to set the delay duration. The allowable range of values is 00 to 99, where 99 corresponds to a delay of 9.9 seconds.
In order to restore the scanner to normal operation, the user needs to scan the Disable Memory Module label. Also the user may clear the contents of the Memory Module by scanning the Clear Memory Mod ule symbol or by disabling and enabling Memory Module. Stored labels are cleared whenever Memory Module is enabled.
-
-
The stored data in the Memory Module cannot be trans­mitted through the Wand Emulation output.
NOTE
The Memory Module feature is to be used only with the Memory Module mode. When used with scanners without this optional mode, programmed instructions will be
CAUTION
damaged.
62 User’s / Programming Guide

Setup

NC Disable Memory Module*#
ND Enable Memory Module
MM
MN
If enabled, this mode intelligently switches from POS mode to Memory Module mode based on power source.
NOTE
ZK Send Memory Module
ZL Clear Memory Module
Enable automatic switch to memory module
Disable automatic switch to memory module *
06656 63

Marker Beam

The Marker Beam feature provides the user with a spotter beam for improved aiming at distant bar code labels and/or in extremely bright environments. You may also find a Marker Beam useful when scanning through showcase glass or bar code menus with labels in close proximity. This feature is available in all scanners without fac tory authorization.
To activate the Marker Beam, the user must also program the dura­tion of the Marker Beam. First, the symbol Enable Marker Beam is scanned and then followed by scanning one digit symbol from the Digit Selections table. Each digit symbol represents the desired time duration of the Marker Beam in milliseconds.
To deactivate the Marker Beam, the user must scan the Disable Marker Beam symbol. For successful programming, the user must hold the trigger down for two seconds after scanning.
NQ Enable Marker Beam
NP Disable Marker Beam
-
64 User’s / Programming Guide
300 ms
50 MS
100 MS
150 MS
200 MS
350 MS
400 MS
450 MS
500 MS
250 MS
06656 65

Scanner Labeling

The PSC Laser Scanners use a low-power, visible laser diode. As with any bright light source, such as the sun, the user should avoid staring directly into the light beam.
Use of controls, adjustments, or performance of proce­dures other than those specified herein may result in
WARNING

Service and Warranty

PSC provides service for its bar code products at the service center located at its manufacturing facility in Eugene, Oregon. The specific warranty language for the bar code scanner is contained in the next section of this manual. Several service plans are available for the products:
All products carry a minimum one year warranty from date of pur­chase.
A warranty extension program is available at a nominal
Factory service is available for out-of-warranty products
hazardous visible light exposure.
annual fee.
by requesting a Return Material Authorization (RMA) for the product from our Repair Service Group. They can be contacted by calling:
1-800-547-2507
within the continental United States, Canada, or Mexico)
or 1-541-683-5700 (elsewhere)
Should you call to request an RMA, have the following information available:
Model Number
Serial Number
Date of Manufacture
Description of Problem
•Purchase Order Number
The PSC Fax number is:
Fax: 541 686-1702
66 User’s / Programming Guide

Maintenance

PSC Scanners are designed to provide trouble-free operation throughout their lives. They contain no components that require peri odic maintenance. Optimum performance may be ensured by follow­ing the preventive maintenance procedures suggested below. If scanning performance declines, please follow these procedures.

Cleaning

A dirty scan window can impair scanning performance. When the window appears to be dirty or smeared, clean it by wiping with a slightly damp cloth or facial tissue. Water or a suitable cleaning solu tion such as Windex™ may be used on the cloth. The plastic case of your scanner can also be cleaned in this manner.
Never use solvents (e.g., alcohol) on the enclosure; they may damage the finish of the scanner.
NOTE

Inspection

Periodically inspect scanner cords and cables for wear and other signs of damage which may interfere with the proper operation of the unit. A badly worn cord or cable should be replaced immediately. Replacement cords and cables can be obtained by contacting your PSC Customer Service Representative.
-
-
Routinely examine scanners for signs of damage. A badly dented enclosure may cause interference with internal components resulting in damage to, or malfunction of the unit. Units with damage to the enclosure should be returned to the factory for repair. Please refer to Service and Warranty Section.
06656 67

Technical Support

PSC Website Support

The PSC website (www.psc.com) is the complete source for technical support and information for PSC products. The site offers the PSC TekForum, product support, product registration, warranty informa tion, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.

PSC Website TekForum

Search for information on the TekForum by clicking on the Support link on the PSC home page. Browse the TekForum to find answers to your questions about common technical issues. Register with TekFo rum to submit a question to the PSC Technical Support Staff.

Reseller Technical Support

An excellent source for technical assistance and information is an authorized PSC reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can pro vide individualized assistance.

Telephone Technical Support

If you do not have internet or email access, you may contact PSC technical support at (541) 349-8281.
-
-
-
68 User’s / Programming Guide

Appendix A

Hexadecimal Conversion Table

To use the conversion table:
1. Find each ASCII character in the tables on the following pages and locate the corresponding bold hexadecimal-equiv alent character in the top row and in the left column of the table. Notice, for example, that the ASCII character “Q” is represented by the hexadecimal numbers 5 (top) and 1 (left).
2. Scan the bar code symbols that correspond to the hexadeci­mal-equivalent characters. First scan the bar code symbol that corresponds to the bold hex character at the top. Then
scan the bar code symbol that corresponds to the bold hex character at the left.
For example, for the ASCII character “Q,” first scan the bar code symbol labeled 5; then scan the bar code symbol labeled
1. If your preamble or postamble contains an “N”, first scan 4 and then E.
3. Repeat this procedure for each ASCII character you wish to enter.
-
06656 69

Hexadecimal Conversion Table

Part A
0
1
0 1
2
3
4
5
6
7
2 3
4 5 6 7
8 9 A B
C D E F
0123
NUL SOH STX ETX
EOT ENQ ACK BEL
BS HT LF VT
FF CR SO SI
DLE DC1 DC2 DC3
DC4 NAK SYN ETB
CAN EM SUB ESC
FS GS RS US
SP ! “ #
$ % & ‘
( ) * ++
,
­. /
0 1 2 3
4 5 6 7
8 9 : ;
< = > ?
70 User’s / Programming Guide

Hexadecimal Conversion Table

Part B
8
4567
0 1 2 3
4 5 6 7
8 9 A B
C D E F
@ A B C
D E F G
H I J K
L M N O
P Q R S
T U V W
X Y Z [
\ ] ^ _
‘ a b c
d e f g
h i j k
l m n o
p q r s
t u v w
x y z {
| } ~ DEL
9
A
B
C
D
E
F
06656 71

Primary Function Key Table

ASCII HEX FUNCTION
NUL 00 CONTROL@
SOH 01 CONTROL A
STX 02 CONTROL B
ETX 03 CONTROL C
EOT 04 CONTROL D
ENQ 05 CONTROL E
ACK 06 CONTROL F
BEL 07 CONTROL G
BS 08 CONTROL H
HT 09 CONTROL I
LF 0A CONTROL J
VT 0B CONTROL K
FF 0C CONTROL L
CR 0D RETURN KEY
SO 0E CONTROL N
SI 0F CONTROL O
DLE 10 CONTROL P
DC1 11 CONTROL Q
DC2 12 CONTROL R
DC3 13 CONTROL S
DC4 14 CONTROL T
NAK 15 CONTROL U
SYN 16 CONTROL V
ETB 17 CONTROL W
CAN 18 CONTROL X
EM 19 CONTROL Y
SUB 1A CONTROL Z
ESC 1B CONTROL [
FS 1C CONTROL \
GS 1D CONTROL ]
RS 1E CONTROL ^
US 1F CONTROL &
72 User’s / Programming Guide

Secondary Function Key Tables

PC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25
ASCII HEX FUNCTION
NUL 00 ESCAPE
SOH 01 NEW LINE ENTER
STX 02 ALT left side Make
ETX 03 ALT left side Break
EOT 04 CTRL left side Make
ENQ 05 CTRL left side Break
ACK 06 ENTER right keypad (NOTE 1)
BEL 07 Cursor up (inner keypad)
BS 08 Cursor dn (inner keypad)
HT 09 Cursor left (inner keypad)
LF 0A Cursor right (inner keypad)
VT 0B TAB FWD
FF 0C DEL (inner keypad)
CR 0D NEW LINE ENTER
SO 0E INS (inner keypad)
SI 0F Page Up (inner keypad)
DLE 10 Page Dn (inner keypad)
DC1 11 HOME (inner keypad)
DC2 12 PRINT SCREEN
DC3 13 BACKSPACE
DC4 14 BACKFIELD (Shift TAB)
NAK 15 SCROLL LOCK
SYN 16 F1
ETB 17 F2
CAN 18 F3
EM 19 F4
SUB 1A F5
ESC 1B F6
FS 1C F7
GS 1D F8
RS 1E F9
US 1F 10
NOTE 1: [+] right keypad for the PC/XT and IBM PS/2 Model 57/25.
06656 73

Secondary Function Key Tables

IBM 3171/3181/3191 and IBM 3477
ASCII HEX FUNCTION
NUL 00 ESCAPE
SOH 01 ON LINE ENTER (Make/Break)
STX 02 ALT left side Make
ETX 03 ALT left side Break
EOT 04 ON LINE ENTER (Make only)
ENQ 05 FIELD EXIT (Make only)
ACK 06 ENTER right keypad
BEL 07 Cursor up (inner keypad)
BS 08 Cursor dn (inner keypad)
HT 09 Cursor left (inner keypad)
LF 0A Cursor right (inner keypad)
VT 0B TAB FWD
FF 0C DEL (inner keypad)
CR 0D FIELD EXIT (Make/Break)
SO 0E INS (inner keypad)
SI 0F Page Up (inner keypad)
DLE 10 Page Dn (inner keypad)
DC1 11 HOME (inner keypad)
DC2 12 PRINT SCREEN
DC3 13 BACKSPACE
DC4 14 BACKFIELD (Shift TAB)
NAK 15 SCROLL LOCK
SYN 16 F1
ETB 17 F2
CAN 18 F3
EM 19 F4
SUB 1A F5
ESC 1B F6
FS 1C F7
GS 1D F8
RS 1E F9
US 1F F10
74 User’s / Programming Guide
VT220/320/420
ASCII HEX FUNCTION
NUL 00
SOH 01 NEW LINE ENTER – Return
STX 02 ALT Make
ETX 03 ALT Break
EOT 04 CTRL Make
ENQ 05 CTRL Break
ACK 06 ENTER – right side keypad
BEL 07 Cursor up
BS 08 Cursor dn
HT 09 Cursor left
LF 0A Cursor right
VT 0B TAB F WD
FF 0C Remove
CR 0D Return (Main keypad)
SO 0E Insert Here
SI 0F Prev
DLE 10 Next
DC1 11 PF1
DC2 12 PF2
DC3 13 BACKSPACE
DC4 14 PF3
NAK 15 PF4
SYN 16 F1
ETB 17 F2
CAN 18 F3
EM 19 F4
SUB 1A F5
ESC 1B F6
FS 1C F7
GS 1D F8
RS 1E F9
US 1F F10
‘~ (terminal may be configured for ESCAPE)
06656 75
Apple MacIntosh
ASCII HEX FUNCTION
NUL 00 NUL
SOH 01 F1
STX 02 F2
ETX 03 F3
EOT 04 F4
ENQ 05 F5
ACK 06 F6
BEL 07 F7
BS 08 F8
HT 09 TA B
LF 0A Enter
VT 0B Page Up
FF 0C Page Down
CR 0D RETURN
SO 0E F9
SI 0F F10
DLE 10 Command On
DC1 11 Delete
DC2 12 Command Off
DC3 13 Left Arrow
DC4 14 Right Arrow
NAK 15 Down Arrow
SYN 16 Up Arrow
ETB 17 Home
CAN 18 End
EM 19 Shift On
SUB 1A Shift Off
ESC 1B Esc
FS 1C Control On
GS 1D Control Off
RS 1E Option (Alt) On
US 1F Option (Alt) Off
76 User’s / Programming Guide

NOTES

06656 77

NOTES

78 User’s / Programming Guide
DECLARATION OF CONFORMITY
PSC hereby declares that the Equipment specified below has been tested and
found compliant to the following Directives and Standards:
Directives: EMC
Low Voltage
Standards: EN
EN 50082-1 EN 60950
Equipment Type: Handheld Laser
Bar Code Scanners
Product: Keyboard Wedge/
Wand Emulation Interface
Brad West Vice President Quality and Process Management PSC, Inc. 959 Terry Street Eugene, OR 97402 U.S.A.
Peter Lomax Vice President Europe, Middle East & Africa PSC Bar Code Ltd. Axis 3, Rhodes Way Watford Hertfordshire WD24 4TR UK
Asia Pacific
PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291
Italy
PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.1 Fax: [39] (0) 39/6859496
Australia
PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] 0 (2) 9878 8999 Fax: [61] 0 (2) 9878 8688
France
PSC S.A.R.L. LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.44
Germany
PSC GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58
Japan
PSC Japan K.K. Shinagawa-ku, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656
Latin America
PSC S.A., INC. Miami, Florida, USA Telephone: (305) 539-0111 Fax: (305) 539-0206
United Kingdom
PSC Bar Code Ltd. Watford, England Telephone: 44 (0) 1923 809500 Fax: 44 (0) 1923 809 505
www.psc.com
PSC Inc.
959 Terry Street Eugene, OR Telephone: (541) 683-5700 Fax: (541) 345-7140
©2000-2005 PSC INC. 06656 (Rev D) 06/05