MX-E25/45
Industrial Vision Processor
with PNP (sourcing) I/0
DESCRIPTION
This guide covers MX-E25/45 Industrial Vision Processor models that contain the letter “P”.
For example MX-E25-P-2. These models provide PNP (sourcing) inputs and outputs.
MX-E25/45 oer the most powerful and exible way to solve even complex machine vision
applications.
• Rugged IP20 housing
• Low Maintenance
• 16 Inputs and 16 Outputs
• Up to 4 GigE cameras
• Easily Accessed connectors
SYSTEM SPECIFICATIONS
Industrial Vision Processors
MX-E25: Intel Celeron 1.7 GHz, 2 cores
MX-E45: Intel Celeron 2.4 GHz, 2 cores
Storage
128 GB SSD
GigE camera ports
MX-E25-2/MX-E45-2: 2 ports (all are PoE capable)
MX-E25-4/MX-E45-4: 4 ports (all are PoE capable)
All MX-E25/45 Industrial Vision Processors have the following specications:
• HD graphics (1920x1200)
• 2 x 10/100/1000 Mbps Base-T Network Interface
• Ethernet/IP, Modbus TCP, OPC, PROFINET communications supported
• 1 x RS232 Serial port
• 16 x Optically Isolated Digital In + 16 x Optically Isolated Digital Out
• Microsoft Windows 10 IoT Enterprise 2016 64-bit
GENERAL VIEW
w eq
rt y u i o
SUPPLY VOLTAGE CONNECTION
Power Connector
+ 24VDC Supply Plus
GND Funcional Ground*
- 24VDC Supply Minus
*Connect the ground using a conductor with minimum 2,5mm2 cross section
HASP KEY USB PORT
1) Reset button
2) USB Port Hasp Key
To enable cameras and licenses, insert the provided Hasp key
in the USB port (labeled USB5), located behind the Front Cover.
STATUS LEDS AND BUTTONS
1) Power, Green
2) HDD, Yellow
3) Link, Yellow
Power Button: Press and release to turn on the
unit or shut down the OS and switch o the unit.
Press and hold to switch o without OS shutdown.
Reset Button: Triggers a hardware and PCI reset.
The unit is restarted.
COMMUNICATIONS
Camera communication uses Cat6 Ethernet cable and provides POE for M1xx and E1xx
cameras. Use only Datalogic provided cables.
4) Run, Green
5) Power Button
6) Reset Button
1) USB 3.0 Keyboard/Mouse
2) 37-pin D-Sub Digital I/O
3) Camera connectors
4) Ethernet 2
5) Ethernet 1
6) COM 1 x RS-232 Serial Port
7) Monitor output: Display Port
8) Monitor output: DVI-I
9) Supply Voltage Connection
Supplied Power Plug
Behind front Cover
Behind Front Cover
DIGITAL I/O CABLES TERMINALS AND CONNECTIONS
Cable Part Number
Digital I/O 37-pin to Terminal Block 248-01 10 606-0675-xx
Digital I/O 37-pin to pigtail (remove one end) 606-0675-xx
NOTE: Do not disconnect the cable at the connector while power is on.
Pin/Terminal Number Color Code Signal Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 Orange/Black Output 1
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Pin 1 Female
Black
Brown
Red
Orange
Yellow
Green
Blue
Purple
Gray
White
Pink
Light Green
Black/White
Brown/White
Red/White
Orange/White
Green/White
Blue/White
Purple/White
Red/Black
Yellow/Black
Green/Black
Gray/Black
Pink/Black
Pink/Red
Pink/Blue
Pink/Green
Light Blue
Light Blue/Black
Light Blue/Red
Light Blue/Blue
Light Blue/Green
Gray/Red
Gray/Green
Purple/Black
Blue/Black
Connector
Solder Side
Input Minus (Note 1)
Input 1- and Event 1-
Input 2- and Event 2Input 3-
Input 4Input 5-
Input 6Input 7-
Input 8Input 9-
Input 10Input 11-
Input 12Input 13-
Input 14Input 15-
Input 16Output Plus (Note 2)
No Connection
No Connection
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
Output 9
Output 10
Output 11
Output 12
Output 13
Output 14
Output 15
Output 16
Output Plus (Note 2)
NOTES:
1: Common Minus for input ports (External
12 to 24 VDC Minus)
2: Common Plus for output ports (Not an
output voltage source. External 12 to 24
VDC Plus is required)
I/O CONFIGURATION
Vision Program Manager (VPM) software installed on the processor is used to create vision
programs and congure input and output response. Refer to the Impact Reference Guide
for programming details.
EXAMPLE I/O CIRCUIT DIAGRAMS
Input
Connection
(Sourcing)
Output
Connection
(Sourcing)
CAMERA CABLES AND TERMINALS CONFIGURATION
Camera trigger and strobe output are provided by an external 6-pin I/O cable with no
connection to the Industrial Vision Processor. Use cable 606-0672-xx (unterminated) or
cable 606-0674-xx (with terminal block 661-0399 or 248-0140). Refer to the MX-E Series
Hardware Guide.
Cable Part Number
Camera Trigger and Strobe 6-pin to Terminal Block 248-0140 or 661-0399 606-0674-xx
Camera Trigger and Strobe: 6-pin to pigtail 606-0672-xx
MECHANICAL DIMENSIONS
128
130
2,5
270
24
222
15
254,75
33
204
2
14
121
1,95
3
3
TECHNICAL DATA
ELECTRICAL FEATURES
Supply voltage (Vs) 24 VDC ± 25%
Current Consumption Nominal: 5.5 A at 24VDC
Digital Inputs 16 opto-isolated, see Digital I/O Specications.
Input Current
Input Resistance 4.7kΩ
On Current 2.0 mA or more
O Current 0.16 mA or less
Response time 200µsec
Digital Outputs
Format Opto-coupler isolated open emitter output
Output Voltage 35VDC (max)
Output Current 100mA (per channel max)
Output saturation voltage <1V
Residual Voltage Output On0.5V or less (Output current ≤50mA)
Response time 200µsec
Camera interface GigE (x 2 or x4 depending on model)
USB Hardware Port USB 2.0 front covered port for USB Hardware Key
USB Ports 4x USB 3.0 ports for monitor, mouse and keyboard
Graphic Interface Intel® HD (1920x1200 resolution), DVI
Host Communications:
Serial Communications 1x RS-232 Serial Port
Ethernet
PCI connections 1x PCIe x8 + 1 PCI
PHYSICAL FEATURES
Dimensions
Weight 2050 g
ON: 2.0 mA or more
OFF 1: 0.16 mA or less
16 opto-isolated current sourcing, see Digital I/O
Specications.
1.0V or less (Output current ≤100mA)
10/100/1000 Mbps Ethernet x 2
Ethernet/IP, Modbus, TCP, OPC, PROFINET
communications supported.
10.03 w x 5.11 h x 10.62 d (in)
255 w x 130 h x 270 d (mm)
Housing material Galvanized plate, plastic
ENVIRONMENTAL FEATURES
Temperature
Relative Humidity (30°)
Vibrations
(EN60068-2-6)
Shock resistance
(EN60068-2-27)
Mechanical protection
(EN 60529)
SOFTWARE FEATURES
Minimum Impact Software
Version Required
264
HARDWARE FEATURES
CPU
System Memory MX-E25/45 DDR4 RAM 8GB
Storage 128 GB, SSD, 1 SATA slot
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support through its website. Log on to
www.datalogic.com.
For quick access, from the home page click on the search icon , and type in the name of the
product you’re looking for. This allows you access to download Data Sheets, Manuals, Software &
Utilities, and Drawings.
Hover over the Support & Service menu for access to Services and Technical Support.
PATENT
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Utility patents: EP2517148B1, EP2649555B1, US10095951, US8888003, US8915443,
US9396404, US9495607, US9798948, ZL200980163411.X, ZL201080071124.9
SEALS
The Industrial Vision Processor has seals in some areas. The seals must not be broken or removed
for any reason. The sealed parts may be opened only and exclusively by Datalogic. Breakage
of these seals by a customer shall result in immediate cancellation of the warranty on the entire
Industrial Vision Processor.
WARRANTY
The warranty period for this product is 24 months. See General Terms and Conditions of Sales at
www.datalogic.com for further details.
CE COMPLIANCE
CE marking states the compliance of the product with essential requirements listed in the applicable
European directive. Since the directives and applicable standards are subject to continuous updates,
and since Datalogic promptly adopts these updates, therefore the EU declaration of conformity is
a living document. The EU declaration of conformity is available for competent authorities and
customers through Datalogic commercial reference contacts. Since April 20th, 2016 the main
European directives applicable to Datalogic products require inclusion of an adequate analysis
and assessment of the risk(s). This evaluation was carried out in relation to the applicable points
of the standards listed in the Declaration of Conformity. Datalogic products are mainly designed for
integration purposes into more complex systems. For this reason, it is under the responsibility of the
system integrator to do a new risk assessment regarding the nal installation.
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
FCC COMPLIANCE
Modications or changes to this equipment without the expressed written approval of Datalogic
could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
EAC COMPLIANCE
Customs Union:
The CU Conformity certication has been achieved; this allows the Product to bear the Eurasian
mark of conformity.
LEGAL NOTICES
© 2019 Datalogic S.p.A. and/or its aliates ♦ ALL RIGHTS RESERVED. ♦ Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced
into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the
express written permission of Datalogic S.p.A. and/or its aliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S. and the E.U.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
incidental or consequential damages resulting from the use of this material.
Datalogic reserves the right to make modications and improvements without prior notication.
Operating: 0° to +50° C (+32° to +122° F)
Storage: -20° to +60° C (-4° to +140° F)
Operating: 10 to 90%
Storage: 5 to 95%
2 to 8 Hz: 1.75 mm amplitude /
9 to 200 Hz: 0,5 g
11ms (15g)
IP20
12.2.2
MX-E25: Intel Celeron 1.7 GHz, 2 cores
MX-E45: Intel Celeron 2.4 GHz, 2 cores
(821006471 REV B)
MX-E25/45
Industrial Vision Processor
with NPN (sinking) I/0
DESCRIPTION
This guide covers MX-E25/45 Industrial Vision Processor models that contain the letter “P”.
For example MX-E25-P-2. These models provide NPN (sinking) inputs and outputs.
MX-E25/45 oer the most powerful and exible way to solve even complex machine vision
applications.
• Rugged IP20 housing
• Low Maintenance
• 16 Inputs and 16 Outputs
• Up to 4 GigE cameras
• Easily Accessed connectors
SYSTEM SPECIFICATIONS
Industrial Vision Processors
MX-E25: Intel Celeron 1.7 GHz, 2 cores
MX-E45: Intel Celeron 2.4 GHz, 2 cores
Storage
128 GB SSD
GigE camera ports
MX-E25-2/MX-E45-2: 2 ports (all are PoE capable)
MX-E25-4/MX-E45-4: 4 ports (all are PoE capable)
All MX-E25/45 Industrial Vision Processors have the following specications:
• HD graphics (1920x1200)
• 2 x 10/100/1000 Mbps Base-T Network Interface
• Ethernet/IP, Modbus TCP, OPC, PROFINET communications supported
• 1 x RS232 Serial port
• 16 x Optically Isolated Digital In + 16 x Optically Isolated Digital Out
• Microsoft Windows 10 IoT Enterprise 2016 64-bit
GENERAL VIEW
w eq
rt y u i o
SUPPLY VOLTAGE CONNECTION
Power Connector
+ 24VDC Supply Plus
GND Funcional Ground*
- 24VDC Supply Minus
*Connect the ground using a conductor with minimum 2,5mm2 cross section
HASP KEY USB PORT
1) Reset button
2) USB Port Hasp Key
To enable cameras and licenses, insert the provided Hasp key
in the USB port (labeled USB5), located behind the Front Cover.
STATUS LEDS AND BUTTONS
1) Power, Green
2) HDD, Yellow
3) Link, Yellow
Power Button: Press and release to turn on the unit
or shut down the OS and switch o the unit. Press
and hold to switch o without OS shutdown.
Reset Button: Triggers a hardware and PCI reset.
The unit is restarted.
COMMUNICATIONS
Camera communication uses Cat6 Ethernet cable and provides POE for M1xx and E1xx
cameras. Use only Datalogic provided cables.
4) Run, Green
5) Power Button
6) Reset Button
1) USB 3.0 Keyboard/Mouse
2) 37-pin D-Sub Digital I/O
3) Camera connectors
4) Ethernet 2
5) Ethernet 1
6) COM 1 x RS-232 Serial Port
7) Monitor output: Display Port
8) Monitor output: DVI-I
9) Supply Voltage Connection
Supplied Power Plug
Behind Front Cover
Behind Front Cover
DIGITAL I/O CABLES TERMINALS AND CONNECTIONS
Cable Part Number
Digital I/O 37-pin to Terminal Block 248-01 10 606-0675-xx
Digital I/O 37-pin to pigtail (remove one end) 606-0675-xx
NOTE: Do not disconnect the cable at the connector while power is on.
Pin/Terminal Number Color Code Signal Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19 Purple/White No Connection
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Pin 1 Female
Black
Brown
Red
Orange
Yellow
Green
Blue
Purple
Gray
White
Pink
Light Green
Black/White
Brown/White
Red/White
Orange/White
Green/White
Blue/White
Red/Black
Orange/Black
Yellow/Black
Green/Black
Gray/Black
Pink/Black
Pink/Red
Pink/Blue
Pink/Green
Light Blue
Light Blue/Black
Light Blue/Red
Light Blue/Blue
Light Blue/Green
Gray/Red
Gray/Green
Purple/Black
Blue/Black
Connector
Solder Side
Output Minus (Note 1)
Input 1- and Event 1-
Input 2- and Event 2Input 3-
Input 4Input 5-
Input 6Input 7-
Input 8Input 9-
Input 10Input 11-
Input 12Input 13-
Input 14Input 15-
Input 16Input Plus (Note 2)
Output 1 Minus (Note 1)
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
Output 9
Output 10
Output 11
Output 12
Output 13
Output 14
Output 15
Output 16
Output Plus (Note 3)
NOTES:
1: Common Minus for output ports (External
12 to 24 VDC Minus)
2: Common Plus for input ports (External
12 to 24 VDC Plus)
3: Common Plus for output ports (Not an
output voltage source. External 12 or 24
VDC Plus is required)
I/O CONFIGURATION
Vision Program Manager (VPM) software installed on the processor is used to create vision
programs and congure input and output response. Refer to the Impact Reference Guide
for programming details.
EXAMPLE I/O CIRCUIT DIAGRAMS
Input
Connection
(Sinking)
Output
Connection
(Sinking)
CAMERA CABLES AND TERMINALS CONFIGURATION
Camera trigger and strobe output are provided by an external 6-pin I/O cable with no
connection to the Industrial Vision Processor. Use cable 606-0672-xx (unterminated) or
cable 606-0674-xx (with terminal block 661-0399 or 248-0140). Refer to the MX-E Series
Hardware Guide.
Cable Part Number
Camera Trigger and Strobe 6-pin to Terminal Block 248-0140 or 661-0399 606-0674-xx
Camera Trigger and Strobe: 6-pin to pigtail 606-0672-xx
MECHANICAL DIMENSIONS
1,95
130
3
204 33
3
128
2
270
24
222
2,5
15
254,75
14
264
121
TECHNICAL DATA
ELECTRICAL FEATURES
Supply voltage (Vs) 24 VDC ± 25%
Current Consumption Nominal: 5.5 A at 24VDC
Digital Inputs 16 opto-isolated, see Digital I/O Specications.
Input Current
Input Resistance 4.7kΩ
On Current 2.0 mA or more
O Current 0.16 mA or less
Response time 200µsec
Digital Outputs
Format Opto-coupler isolated open collector output
Output Voltage 35VDC (max)
Output Current 100mA (per channel max)
Output saturation voltage <1V
Residual Voltage Output On0.5V or less (Output current ≤50mA)
Response time 200µsec
Camera interface GigE (x 2 or x4 depending on model)
USB Hardware Port USB 2.0 front covered port for USB Hardware Key
USB Ports 4x USB 3.0 ports for monitor, mouse and keyboard
Graphic Interface Intel® HD (1920x1200 resolution), DVI
Host Communications:
Serial Communications 1x RS-232 Serial Port
Ethernet
PCI connections 1x PCIe x8 + 1 PCI
PHYSICAL FEATURES
Dimensions
Weight 2050 g
ON: 2.0 mA or more
OFF 1: 0.16 mA or less
16 opto-isolated current sinking, see Digital I/O
Specications.
1.0V or less (Output current ≤100mA)
10/100/1000 Mbps Ethernet x 2
Ethernet/IP, Modbus, TCP, OPC, PROFINET
communications supported.
10.03 w x 5.11 h x 10.62 d (in)
255 w x 130 h x 270 d (mm)
Housing material Galvanized plate, plastic
ENVIRONMENTAL FEATURES
Temperature
Relative Humidity (30°)
Vibrations
(EN60068-2-6)
Shock resistance
(EN60068-2-27)
Mechanical protection
(EN 60529)
SOFTWARE FEATURES
Minimum Impact Software
Version Required
HARDWARE FEATURES
CPU
System Memory MX-E25/45 DDR4 RAM 8GB
Storage 128 GB, SSD, 1 SATA slot
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support through its website. Log on to
www.datalogic.com.
For quick access, from the home page click on the search icon , and type in the name of the
product you’re looking for. This allows you access to download Data Sheets, Manuals, Software &
Utilities, and Drawings.
Hover over the Support & Service menu for access to Services and Technical Support.
PATENT
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Utility patents: EP2517148B1, EP2649555B1, US10095951, US8888003, US8915443,
US9396404, US9495607, US9798948, ZL200980163411.X, ZL201080071124.9
SEALS
The Industrial Vision Processor has seals in some areas. The seals must not be broken or removed
for any reason. The sealed parts may be opened only and exclusively by Datalogic. Breakage
of these seals by a customer shall result in immediate cancellation of the warranty on the entire
Industrial Vision Processor.
WARRANTY
The warranty period for this product is 24 months. See General Terms and Conditions of Sales at
www.datalogic.com for further details.
CE COMPLIANCE
CE marking states the compliance of the product with essential requirements listed in the applicable
European directive. Since the directives and applicable standards are subject to continuous updates,
and since Datalogic promptly adopts these updates, therefore the EU declaration of conformity is
a living document. The EU declaration of conformity is available for competent authorities and
customers through Datalogic commercial reference contacts. Since April 20th, 2016 the main
European directives applicable to Datalogic products require inclusion of an adequate analysis
and assessment of the risk(s). This evaluation was carried out in relation to the applicable points
of the standards listed in the Declaration of Conformity. Datalogic products are mainly designed for
integration purposes into more complex systems. For this reason, it is under the responsibility of the
system integrator to do a new risk assessment regarding the nal installation.
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
FCC COMPLIANCE
Modications or changes to this equipment without the expressed written approval of Datalogic
could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
EAC COMPLIANCE
Customs Union:
The CU Conformity certication has been achieved; this allows the Product to bear the Eurasian
mark of conformity.
LEGAL NOTICES
© 2019 Datalogic S.p.A. and/or its aliates ♦ ALL RIGHTS RESERVED. ♦ Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced
into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the
express written permission of Datalogic S.p.A. and/or its aliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S. and the E.U.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
incidental or consequential damages resulting from the use of this material.
Datalogic reserves the right to make modications and improvements without prior notication.
Operating: 0° to +50° C (+32° to +122° F)
Storage: -20° to +60° C (-4° to +140° F)
Operating: 10 to 90%
Storage: 5 to 95%
2 to 8 Hz: 1.75 mm amplitude /
9 to 200 Hz: 0,5 g
11ms (15g)
IP20
12.2.2
MX-E25: Intel Celeron 1.7 GHz, 2 cores
MX-E45: Intel Celeron 2.4 GHz, 2 cores
(821006471 REV B)