Datalogic BC9xx0-STAR, BC9180-BT Quick Reference Manual

BC9xx0-STAR
Base Station/Charger
Quick Reference Guide
Datalogic ADC S.r.l.
Via S. Vitalino, 13 40012 Lippo, Calderara di Reno (BO) Italy Tel. +39 051 3147011 Fax +39 051 3147288
©2016 Datalogic S.p.A. and its Group companies
An Unpublished Work - All rights reserved. No part of the contents of this docu­mentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC S.r.l. or its subsidiaries or affiliates ("Datalogic" or "Datalogic ADC”). Owners of Dat­alogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business pur­poses. Purchaser shall not remove or alter any proprietary notices, including copy­right notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation. Should future revisions of this manual be published, you can acquire printed ver­sions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com
) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. PowerScan is a trademark of Datalogic S.p.A. or of Datalogic Group companies, registered in many countries, including the U.S. and the E.U. All other brand and product names may be trademarks of their respective owners.
Patents
See www.patents.datalogic.com
for patent list.
See the Regulatory Addendum included with your product for additional regulatory, safety and legal information.
Table of Contents
Using the BC9xx0 Base Station ..................................................................... 1
Installation ....................................................................................................... 2
Mounting the BC9xx0 Cradle ......................................................................... 2
Mounting Brackets ................................................................................. 2
To change the Bracket:................................................................... 3
Permanent Mounting ............................................................................. 4
Mounting for Portable Use .................................................................... 4
Mounting the Metal Plate.............................................................. 4
Attaching the Metal Plate to Base................................................ 5
System Connections ............................................................................... 6
Connecting and Disconnecting the Interface Cable ............................ 6
BC9xx0 Configuration ..................................................................................... 8
Datalogic Aladdin™ .................................................................................. 8
Serial Configuration ................................................................................ 8
Configuration Bar Codes ........................................................................ 8
Resetting Standard Product Defaults .................................................. 8
Compatibility with the PowerScan™ 8000 family ................................ 9
Selecting the Interface Type .......................................................................... 9
Configuring the Interface ............................................................... 9
Keyboard Interface ....................................................................... 11
Scancode Tables............................................................................ 12
Country Mode ........................................................................................ 13
Caps Lock State ..................................................................................... 17
Numlock ................................................................................................. 18
Technical Features ........................................................................................ 19
Datalogic ADC Limited Factory Warranty ................................................... 21
Ergonomic Recommendations .................................................................... 22
Services and Support .................................................................................... 23
Products......................................................................................... 23
Service & Support ......................................................................... 23
Contact Us ..................................................................................... 23
NOTES
Quick Reference Guide 1
Using the BC9xx0 Base Station
The BC9xx0 base station, when paired with one or more PowerScan™ PM9X00 readers, builds a Cordless Reading System for the collection, decoding and transmission of bar code data. It can be connected to a Host PC via RS232, USB, or KBD Wedge, and is suited for single-cradle layouts.
The BC9x60 models also allow multi cradle layouts through an RS485 Net­work. For this network connection refer to the Programming Reference Guide.The BC91x0 models provide a spare battery charger slot.
The label on the cradle contains LED indicators and a multi-function button. When the button is pressed, the cradle will transmit a "broadcast" message. When the broadcast is sent, all properly configured scanners (Radio RX Time­out set to keep the radio "awake") that are linked to that base and within radio range coverage will emit a beep and blink within 5 seconds. This functionality is useful to:
verify which scanners are linked to a certain base station
detect a scanner forgotten somewhere
The LEDs signal the BC9xx0 status, as shown.
LED STATUS
Aux
Yellow On = BC9xx0 is powered through an external power supply.
Host Yellow On = BC9xx0 is powered by the Host.
Reader
Green On = the reader battery is completely charged. Red On = the reader battery is charging. Orange Blinking = reader battery fault - replace battery. Red / Green Alternatively Blinking = charging error - see PRG. Off = reader not in the cradle or not properly inserted.
Spare (BC91x0 models only)
Green On = the spare battery is completely charged. Orange Blinking = spare battery fault - replace spare battery. Red/Green Alternatively Blinking = charging error - see PRG. Off = no spare battery in the housing or battery not fully inserted.
Radio Yellow Blinking = radio activity.
Ethernet (Ethernet models only)
Green Blinking = Ethernet activity.
Installation
2 BC 9xx0 Cradle
Installation
To set up your BC9xx0 cradle you must:
1. Physically install the cradle.
2. Make all system connections.
3. Configure the BC9xx0 cradle.
Mounting the BC9xx0 Cradle
The cradle package contains the following items:
The cradle can be either mounted on a flat surface for desktop usage or affixed vertically to a wall.
Mounting Brackets
The cradle comes with two different mounting brackets. The appropriate bracket is used depending on whether the cradle will be mounted on a hori­zontal or vertical surface. When shipped, the cradle has the Desktop Mount­ing Bracket installed. For vertical installation, the Wall Mounting Bracket must be attached instead.
Figure 1. Mounting Brackets
• BC9xx0 Base Station (with Desktop Mounting Bracket installed)
• 1 Metal Mounting plate
• BC9xx0 Quick Reference Guide (this manual)
• 1 Wall Mounting Bracket
A Tabs B Ribs CBosses
Desktop Mounting Bracket
Wall Mounting Bracket
B
C
(Horizontal )
(Vertical)
A
A
A
Mounting the BC9xx0
Quick Reference Guide 3
Desktop mount bracket has ribs to keep the scanner in place when the cradle is horizontal
Wall mount bracket contains bosses to keep the scanner in place when the cradle is vertical.
To change the Bracket:
1. Remove the screw holding the Bracket in place. Retain the screw for re-use.
2. Carefully lift off the Bracket.
3. Install the other bracket by first slipping the end tab into place on the base station, then easing the tabs (shown in Figure 1 on page 2) into place on the sides.
4. Replace the screw to secure the Bracket to the Base Station.
Figure 2. Changing the Bracket
12
3
Mounting the BC9xx0 Cradle
4 BC 9xx0 Cradle
Permanent Mounting
For either desktop or wall mounting, the cradle can be fastened directly to a flat surface using screws (not included).
Figure 3. Base Station Bottom
Mounting for Portable Use
If portability of the cradle is required, the metal plate must be used. There are two ways this can be done: (1) by first mounting the metal plate on a flat sur­face so the cradle can be slid off and on, or (2) mounting the metal plate onto the back of the base station and then screwing both to the desired surface.
Mounting the Metal Plate
1. Affix the metal plate onto the desired mounting surface using the two center screw holes (see Figure 4 on page 5).
2. Remove the adhesive strips protecting the mounting tabs on the cradle, shown in Figure 3.
3. Slide the tabs on the back of the cradle onto the metal plate as shown in Figure 4.
4. After aligning the tabs, push up to lock into place.
When mounting on drywall, the base should be screwed to a wall stud or supporting beam for additional support.
A Rubber Feet B
Protective adhesive strips
C Mounting Holes
For additional security on wall mounting, it is strongly recommended that the cradle be secured into place using two auxiliary screws through the mounting holes on the side.
A
C
B
A
Mounting the BC9xx0
Quick Reference Guide 5
Figure 4. Mounting Plate on Wall
Attaching the Metal Plate to Base
Alternatively, the mount can be attached first to the base, then both can be mounted to a wall as described above.
Figure 5. Attaching Mounting Plate to Base
Base with Mount attached
Mounting the BC9xx0 Cradle
6 BC 9xx0 Cradle
System Connections
The BC9xx0 cradle provides a multi-interface connector and a power supply connector as shown:
Connecting and Disconnecting the Interface Cable
The BC9xx0 can be connected to a Host by means of a multi-interface cable, which must be simply plugged into the Host connector, visible on the front panel of the cradle.
To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle. Push down on the clip while unplugging the cable. Refer to the following figures:
CAUTION
Connections should always be made with power off!
Power Supply
Multi-Interface Connector
Power
Interface Emulation to Host
Connecting/Disconnecting the Cable
Mounting the BC9xx0
Quick Reference Guide 7
RS232
USB*
*The power supply is optional, the cradle can be powered by the USB port. In this case the full charging of an empty battery will take about 10 hours. For intense usage and/or when the system is shut down during the night, the use of an external power supply is recommended.
WEDGE
BC9xx0 Configuration
8 BC 9xx0 Cradle
BC9xx0 Configuration
The BC9xx0 configuration can be performed in three ways: by using the Data­logic Aladdin
software configuration program, by sending configuration strings from the Host PC via the RS232 or USB-COM interface or by reading configuration bar codes with the PowerScan
PM9X00 reader.
Datalogic Aladdin™
Datalogic Aladdin™ is a multi-platform utility program that provides a quick and user-friendly configuration method via the RS232/USB-COM interface. It also allows upgrading the software of the connected device (see the Datalogic Aladdin
Help On-Line for more details).
Serial Configuration
By connecting the BC9xx0 to a PC through an RS232 or USB-COM interface cable it is possible to send configuration strings from the PC to BC9xx0.
Configuration Bar Codes
Link the cradle and the reader using the procedures described in the Power­Scan
PM9X00 Quick Reference. Once the pairing is complete, you can config-
ure the BC9XX0 cradle by reading configuration bar codes in this manual. To configure the BC9XX0 using the PowerScan
PM9X00 reader (paired to the cradle with the Bind command), follow the procedure according to the inter­face selected.
Resetting Standard Product Defaults
Reference the PRG for a listing of standard factory settings. If you aren’t sure what programming options are in your reader, or you’ve changed some options and want the factory settings restored, scan the
Standard Product
Default Settings
bar code below to copy the factory configuration for the cur-
rently active interface to the current configuration.
Factory defaults are based on the interface type. Configure the reader for the correct interface before scanning this label.
CAUTION
Scanning this bar code will RESET all settings for the PowerScan
PM9X00. Any customized settings that may have been applied to the reader will be lost.
Standard Product Default Settings
Selecting the Interface
Quick Reference Guide 9
To change the defaults refer to the PowerScan™ 9X00 PRG, or to the Datalogic Aladdin
Configuration program, both downloadable from the Datalogic web-
site.
Compatibility with the PowerScan™ 8000 family
The BC9xx0 can be programmed to operate in a mode compatible with the PowerScan
8000 family. For further details and for the relevant configuration
strings and labels, refer to the PRG.
Selecting the Interface Type
Upon completing the physical connection between the reader and its host, scan the appropriate bar code for your system’s correct interface type.
Configuring the Interface
Scan the programming bar code which selects the appropriate interface type for the system the reader will be connected to.
Unlike some other programming features and options, interface selec­tions require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scanning an interface selec­tion bar code.
Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold for 5 seconds. The scanner will change to a state that allows programming with bar codes.
RS232
RS232 standard interface
Select RS232-STD
RS232 Wincor-Nixdorf
Select RS232-WN
RS232 for use with OPOS/UPOS/JavaPOS
Select RS232 OPOS
Selecting the Interface Type
10 BC 9xx0 Cradle
USB
USB COM to simulate RS232 standard interface
USB-COM-STD
a
USB-OEM
(can be used for OPOS/UPOS/JavaPOS)
USB-OEM
USB Keyboard with standard key encoding
Select USB Keyboard
USB Keyboard with alternate key encoding
USB Alternate Keyboard
a. Download the correct USB COM driver from www.datalogic.com
Selecting the Interface
Quick Reference Guide 11
Keyboard Interface
Use the programming bar codes to select options for USB Keyboard and Wedge Interfaces.
KEYBOARD
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/
Standard Key Encoding
Select KBD-AT
Keyboard Wedge for IBM AT PS2 with standard key encoding
but without external keyboard
Select KBD-AT-NK
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95
w/Alternate Key
Select KBD-AT-ALT
Keyboard Wedge for IBM AT PS2 with alternate key encoding
but without external keyboard
Select KBD-AT-ALT-NK
Selecting the Interface Type
12 BC 9xx0 Cradle
Country Mode
This feature specifies the country/language supported by the keyboard.
COUNTRY MODE
ENTER/EXIT PROGRAMMING MODE
Country Mode = U.S.
Country Mode = Belgium
Country Mode = Britain
Selecting the Interface
Quick Reference Guide 13
COUNTRY MODE (continued)
Country Mode = Croatia
Country Mode = Czech Republic
Country Mode = Denmark
Country Mode = France
Country Mode = French Canadian
Country Mode = Germany
Selecting the Interface Type
14 BC 9xx0 Cradle
COUNTRY MODE (continued)
Country Mode = Hungary
Country Mode = Italy
Country Mode = Japanese 106-key
Country Mode = Lithuanian
Country Mode = Norway
Country Mode = Poland
Country Mode = Portugal
Selecting the Interface
Quick Reference Guide 15
COUNTRY MODE (continued)
Country Mode = Romania
Country Mode = Spain
Country Mode = Sweden
Country Mode = Slovakia
Country Mode = Switzerland
Selecting the Interface Type
16 BC 9xx0 Cradle
Caps Lock State
This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alter­nate key encoding keyboard is selected.
It does not apply to USB keyboard
ENTER/EXIT PROGRAMMING MODE
Caps Lock State = Caps Lock OFF
Caps Lock State = Caps Lock ON
Caps Lock State = AUTO Caps Lock Enable
Selecting the Interface
Quick Reference Guide 17
Numlock
This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding inter­faces. It does not apply to USB keyboard.
ENTER/EXIT PROGRAMMING MODE
Numlock = Numlock key unchanged
Numlock = Numlock key toggled
Technical Features
18 BC 9xx0 Cradle
Technical Features
* Having a switching regulator inside, the BC9xx0 draws the same power,
regardless of the supply voltage. i.e. as the input voltage increases the cur­rent drawn decreases
Electrical Features
Supply Voltage
External Power
Host Power
10 - 30 VDC
5 VDC ±10%
Power Consumption
External Power
Host Power
max. 10 W (charging) *
max. 500 mA (charging)
Indicators
Ext. Power/Data yellow LED
Host Power/Data yellow LED
Reader batt. state green/red LED
Spare batt. state green/red LED
Radio yellow LED
Ethernet green LED (Ethernet models only)
Time of Recharge
External Power
Host Power
max. 4 hours with 2150 mAh Li-Ion battery
max. 10 hours with 2150 mAh Li-Ion battery
Environmental Features
Working Temperature
Radio
Battery Charging
-20° to +50
C / -4 to +122 °F
0° to +40 °C / +32° to +104 °F
Storage Temperature -20° to +70
C / -4 to +158 °F
Humidity 90% non condensing
Protection Class IP40
Mechanical Features
Weight without metal plate about 390 g / 13.76 oz
Dimensions (without antenna) 235 x 108 x 80 mm
Regulatory
See the regulatory addendum for details
Radio Features
Frequency working center
910MHz 433MHz
Programmable Speed
19.2 kb/s
115.2 kb/s 500 kb/s (default)
36.8 kb/s
500 kb/s (default)
Typical Range (in open air) see reader’s manual
Max number of devices per base station
16
Datalogic ADC Limited
Quick Reference Guide 19
Datalogic ADC Limited Factory Warranty
Warranty Coverage
Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic (”Datalogic”) hardware products are warranted against defects in material and workmanship under normal and proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its normal operating condition. Repair or replacement of product during the warranty does not extend the original warranty term. Products are sold on the basis of specifications applicable at the time of manufacture and Datalogic has no obligation to modify or update products once sold.
If Datalogic determines that a product has defects in material or workmanship, Datalogic shall, at its sole option repair or replace the product without additional charge for parts and labor, or credit or refund the defective products duly returned to Datalogic. To perform re­pairs, Datalogic may use new or reconditioned parts, components, subassemblies or prod­ucts that have been tested as meeting applicable specifications for equivalent new material and products. Customer will allow Datalogic to scrap all parts removed from the repaired product. The warranty period shall extend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase (Warranty period). Datalogic warrants repaired hardware devices against defects in workmanship and materi­als on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period, which­ever is longer. Datalogic does not guarantee, and it is not responsible for, the maintenance of, damage to, or loss of configurations, data, and applications on the repaired units and at its sole discretion can return the units in the “factory default” configuration or with any soft­ware or firmware update available at the time of the repair (other than the firmware or soft­ware installed during the manufacture of the product). Customer accepts responsibility to maintain a back up copy of its software and data.
Warranty Claims Process
In order to obtain service under the Factory Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Dat­alogic a return authorization number (RMA) for return of the product to a designated Data­logic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with ship­ping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. Failure to follow the applicable RMA policy, may result in a processing fee. Customer shall be responsible for return shipment ex­penses for products which Datalogic, at its sole discretion, determines are not defective or eligible for warranty repair.
Warranty Exclusions
The Datalogic Factory Warranty shall not apply to:
(i) any product which has been damaged, modified, altered, repaired or upgraded by
other than Datalogic service personnel or its authorized representatives;
(ii) any claimed defect, failure or damage which Datalogic determines was caused by
faulty operations, improper use, abuse, misuse, wear and tear, negligence, improper storage or use of parts or accessories not approved or supplied by Datalogic;
(iii) any claimed defect or damage caused by the use of product with any other instru-
ment, equipment or apparatus;
(iv) any claimed defect or damage caused by the failure to provide proper maintenance,
including but not limited to cleaning the upper window in accordance with product manual;
Ergonomic Recommendations
20 BC 9xx0 Cradle
(v) any defect or damage caused by natural or man-made disaster such as but not lim-
ited to fire, water damage, floods, other natural disasters, vandalism or abusive events that would cause internal and external component damage or destruction of the whole unit, consumable items;
(vi) any damage or malfunctioning caused by non-restoring action as for example firm-
ware or software upgrades, software or hardware reconfigurations etc.;
(vii) the replacement of upper window/cartridge due to scratching, stains or other deg-
radation and/or
(viii) any consumable or equivalent (e.g., cables, power supply, batteries, keypads, touch
screen, triggers etc.).
No Assignment
Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee of product. No attempted assignment or transfer in vio­lation of this provision shall be valid or binding upon Datalogic.
DATALOGIC'S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IM­PLIED, ORAL OR WRITTEN, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. DATALOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UN­DER THE ABOVE. THE REMEDY SET FORTH IN THIS WARRANTY STATEMENT IS THE CUSTOM­ER’S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES RE­GARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of spe­cific written instructions for the return of product to Customer, Datalogic will select the car­rier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
Ergonomic Recommendations
Reduce or eliminate repetitive motion
Maintain a natural position
Reduce or eliminate excessive force
Keep objects that are used frequently within easy reach
Perform tasks at correct heights
Reduce or eliminate vibration
Reduce or eliminate direct pressure
Provide adjustable workstations
Provide adequate clearance
Provide a suitable working environment
Improve work procedures
CAUTION
In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety pro­grams to prevent employee injury.
Services and Support
Quick Reference Guide 21
Services and Support
Datalogic provides several services as well as technical support through its website. Log on to
www.datalogic.com
and click on the links indicated for fur-
ther information.
Products
Search through the links to arrive at your product page where you can down­load specific
Manuals
and
Software & Utilities
, including:
Datalogic Aladdin™
, a multi-platform utility program that allows device configuration using a PC. It provides RS232 and USB-COM interface configuration, printing of configuration bar codes, and firmware upgrades.
Service & Support
Technical Support
- Product documentation and programming guides
and Technical Support Department in the world
Service Programs
- Warranty Extensions and Maintenance Agree-
ments
Repair Services
- Flat Rate Repairs and Return Material Authoriza-
tion (RMA) Repairs
Downloads
– Manuals & Documentation, Data Sheets, Product Cata-
logues, etc.
Contact Us
Information Request Form and Sales & Service Network
Services and Support
22 BC 9xx0 Cradle
NOTES
©2013-2016 Datalogic ADC S.r.l. • All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. PowerScan is a trademark of Datalogic S.p.A. or of Datalogic Group companies, registered in many countries, including the U.S. and the E.U.
Datalogic ADC S.r.l.
Via S. Vitalino, 13 | 40012 |Lippo, Calderara di Reno (BO)| Italy Telephone: +39 051 3147011 | Fax: +39 051 3147288
www.datalogic.com
820080914 (Rev A) Sept. 2016
Loading...