An Unpublished Work - All rights reserved. No part of the contents of this documentation or the
procedures described therein may be reproduced or transmitted in any form or by any means with-
out prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic"
or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revo-
cable license to reproduce and transmit this documentation for the purchaser's own internal busi-
ness purposes. Purchaser shall not remove or alter any proprietary notices, including copyright
notices, contained in this documentation and shall ensure that all notices appear on any reproduc-
tions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contact-
ing your Datalogic representative. Electronic versions may either be downloadable from the Data-
logic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our
website and would like to make comments or suggestions about this or other Datalogic publica-
tions, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete
and accurate, however, Datalogic reserves the right to change any specification at any time with-
out prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A and the E.U. All other brand and product names referred to herein may be
trademarks of their respective owners.
Patents
This product is covered by US Pat. 7,948,214 B2. Additional patents pending.
BC-80X0
1
LED
STATUS
Aux
Yellow On = BC-80X0 is powered through an external power supply.
Yellow Blinking = BC-80X0 transmission occurs over the Host port.
Host
Yellow On = BC-80X0 is powered by the Host.
Yellow Blinking = BC-80X0 transmission occurs over the Host port.
Reader
Green On = the reader battery is completely charged.
Red On = the reader battery is charging.
Orange Blinking = reader battery fault – replace battery.
Red / Green Alternatively Blinking = charging error - see Ref. Manual
Spare*
Green On = the spare battery is completely charged.
Red On = the spare battery is charging.
Orange Blinking = spare battery fault – replace battery.
Red / Green Alternatively Blinking = charging error - see Ref. Manual
Figure 1 – Cradle Overview
Figure 2 – LEDs
USING THE BC-80X0 RADIO CRADLE
The BC-80X0 cradle, paired with one or more Powerscan™ M8300 readers,
builds a Cordless Reading System for the collection, decoding and transmission
of barcoded data.
It can be connected to a Host PC through an RS-232, USB, Wedge or Pen
cable and is suited for single-cradle point-to-point layouts. It can also be
connected to a C-BOX and therefore integrated into a fixed scanner application.
The BC-8060 models also allow multi-cradle layouts through an RS-485
Network. For this network connection refer to the Powerscan™ D8330/M8300
Reference Manual.
The label on the cradle contains LED indicators and a scan finder button.
When the button is pressed, the cradle transmits a “broadcast” message. All
properly configured scanners (Radio RX Timeout set to keep the radio “awake”)
that are linked to that base (through a bind or a join sequence) and within radio
range coverage will emit a beep sequence once every 2 seconds for 30
seconds. This functionality is useful to:
- verify which scanners are linked to a certain base station
- detect a scanner forgotten somewhere
The LEDs signal the BC-80X0 status, as described in the following table:
* This LED refers to the accessory SBS-8000 Spare Battery Slot when mounted to the BC-8060. Not
available for BC-8010 models.
DATALOGIC
2
BC-80X0
1 horizontal base
BC-80X0 Quick Reference Guide
2 wall-mounting lock hinges
BC-8000 Antenna
4 rubber feet
2 adhesive strips
1 inclined base
BC-80X0 Cradle mounted on the Inclined Base
To set up your BC-80X0 cradle you must:
1. Physically install the cradle.
2. Make all system connections.
3. Configure the BC-80X0 cradle.
INSTALLATION
MOUNTING THE BC-80X0 CRADLE
The cradle package contains the following items:
The cradle can be mounted for portable or fixed desktop usage, or it can be
fixed to a wall. The horizontal base allows portable and fixed desktop usage,
while the inclined base provides desktop and wall mounting guaranteeing a
comfortable handling of the Powerscan™ M8300 reader.
BC-80X0 Cradle mounted on the Horizontal Base
BC-80X0
3
Mounting
Tabs (4)
Mounting
Holes (2)
Rubber Foot
Seat (4)
Adhesive
Strip Seat (2)
Cable
Channels
Mounting
Tabs (4)
Mounting
Holes (4)
Cable
Channels
Adhesive
Strip Seat (2)
Rubber
Foot Seat (4)
Desktop mounting
For desktop usage, you can mount the cradle either on the horizontal base, for
reduced overall dimensions, or on the inclined base for a more ergonomic taking
out and insertion of the reader onto the cradle.
Horizontal base
Top View Bottom View
Inclined base
Top View Bottom View
DATALOGIC
4
1
2
1
2
Horizontal Base
Inclined Base
PORTABLE DESKTOP USE
1. Correctly position the BC-80X0 onto the base by sliding it along the
mounting tabs until aligned.
2. Carefully clean the rubber foot seats of the base to remove any impurities
that could reduce adhesion.
3. Remove the protective plastic from the rubber feet and stick them onto the
bottom surface of the base.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
FIXED DESKTOP USE
For fixed desktop installation, use the adhesive strips or fixing screws (not
provided) according to your needs.
For mounting with adhesive strips:
1. Position the cradle onto the base by sliding it along the mounting tabs until
aligned.
2. Carefully clean the adhesive strip seats of the base to remove any
impurities that could reduce adhesion.
3. Remove the protective plastic from one side of the adhesive strips and
stick them onto the base surface.
4. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels, as shown in the figures below:
BC-80X0
5
5. Remove the plastic from the other side of the strips and affix the base to
the table.
6. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
For mounting with screws:
1. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels, as shown in the figures below:
2. Position the base on the table and affix it by means of the screws (not
provided).
3. Position the cradle on the base by sliding it along the mounting tabs until
aligned.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
Wall Mounting
1. Remove the yellow caps and insert the two wall mounting lock hinges
provided with your cradle.
DATALOGIC
6
If using the adhesive strips:
3. Carefully clean the adhesive strip
seats of the base to remove any
impurities that could reduce
adhesion.
4. Remove the protective plastic
from one side of the adhesive
strips and stick them onto the
base surface.
5. Remove the plastic from the
other side of the strips and affix
the base to the wall as indicated
in the figure below.
If using the mounting screws:
3. Using the mounting holes on the
base as a pattern, mark the wall
where you desire to mount the
BC-80X0.
4. Drill the appropriate size holes
and insert the threaded dowels
(not provided) into the holes.
5. Position the base on the wall as
indicated in the figure below and
affix it by means of the screws
(not provided).
2. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels (see figures at page 4).
6. Attach the cradle on the base by sliding it along the mounting tabs until
aligned.
7. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
Inclined Base Wall-mounting
BC-80X0
7
A pre-printed barcode label is included in the
package for rapid configuration of point-topoint applications. If you wish to use this
method, apply this label to the seat provided
on the BC-80X0 cradle as shown in the
figure. See the Powerscan™ M8300 Quick
Reference Manual for the configuration
procedure.
The BC-80X0 cradle provides two interface connectors and a power supply
connector as shown in the figure on the next page:
The RS-485 Network connection is available only on BC-8060 models. For
details about this type of connection, refer to the Powerscan™ D8330/M8300
Reference Manual.
To connect the BC-80X0 cradle to the Host through the multi-interface
connector, use the cable corresponding to the desired interface type.
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.