Dart Controls 250 Series Catalog Page

250 Series Variable Speed DC Control
Chassis
NEMA 4/12
Speed Potentiometer
Kit Included
cULus Listed
The 250 Series offers superb flexibility, reliability, and value. A general purpose, economical control rated to 2 horsepower, it provides the ultimate in standard features and versatility including:
dual voltage (120/240 VAC), adjustable H.P. settings, packaged power bridge, barrier terminal strip, fully rated-no auxiliary heatsink required, and chassis or NEMA 4/12 enclosure. Many
options further extend the 250’s capabilities.
Washdown Duty
A logical, easily accessible layout simplifies installation and adjustment. Clean design, quality components and careful assembly are trademarks of Dart Controls.
250 SERIES STANDARD FEATURES
• Dual voltage - 120/240 VAC, 50/60Hz
• Adjustable horsepower settings
• Barrier terminal strip
• Packaged bridge supply (fullwave)
• 1% speed regulation with armature voltage feedback; ±1/2% with tach feedback
• Adjustable Minimum speed (0–30% of max)
• Adjustable Maximum speed (66–110% of base)
• Adjustable IR Compensation
• Adjustable Linear Acceleration (0.5-8 sec.)
• Adjustable Current Limit to 15 Amps
• Line voltage compensation
• 5K ohm speed potentiometer with 8" leads, knob and dial included
• Power on/off switch (enclosed models)
• 50:1 speed range
• Overload capacity: 150% for one minute
• Transient voltage protection
• Voltage following mode or DC tachometer follower by supplying ungrounded analog input signal (0–12 VDC)
• DC tachometer feedback (6V at base speed)
• Inhibit circuit - permits start & stop without breaking AC lines
• Remote start/stop via pot circuit or inhibit circuit
• Shunt fi eld supply provided (1 Amp max; 100V for 120 VAC; 200V for 240 VAC input)
• AC line fuse
• Enclosed models rated NEMA 4/12 w/threaded conduit holes
ELECTRICAL SPECIFICATIONS AC INPUT 50/60 HZ
120 VAC Single Phase Input, 0-90 VDC Output
MAX. AC MAX. ARM* H.P. AMPS KVA AMPS DC
1/50 0.5 0.06 0.4 1/20 1.0 0.12 0.8 1/8 2.0 0.24 1.6 1/4 3.5 0.42 2.7 1/3 4.4 0.53 3.4 1/2 6.5 0.78 5.0 3/4 9.3 1.12 7.2 1 13.2 1.58 10.2
240 VAC Single Phase Input, 0-180 VDC Output
MAX. AC MAX. ARM* H.P. AMPS KVA AMPS DC
1/4 1.8 0.42 1.4 1/3 2.2 0.53 1.7 1/2 3.3 0.78 2.5 3/4 4.8 1.15 3.7 1 6.5 1.56 5.0 1 1/2 9.7 2.33 7.5 2 12.9 3.10 9.9
For dual voltage 250 series, use table for the input voltage you are using. * Minimum Armature Amps: 150mA D.C.
POPULAR OPTIONS
250 SERIES SELECTION GUIDE
H.P. RANGE CHASSIS “C” ENCLOSED “E”
120 VAC Single Phase Input, 0-90 VDC Output
1/50 - 1/8 251G-12C 251G-12E 1/8 - 1.0 253G-200C 253G-200E
240 VAC Single Phase Input, 0-180 VDC Output
1/25 - 1/4 251G-12C 251G-12E 1/4 - 2.0 253G-200C 253G-200E
Horsepower settings are adjustable, 1/50 thru 1/8 and 1/8 thru 2 - see installation manual. Control is tested and calibrated for maximum horsepower in its category.
DIMENSIONAL SPECIFICATIONS
MODEL WIDTH LENGTH DEPTH WEIGHT
English (inches)
Chassis 5.53 7.00 1.63 14.25 oz. Enclosed 5.53 7.25 2.75 17.50 oz.
Metric (centimeters)
Chassis 14.1 17.78 4.14 404 gm. Enclosed 14.1 18.42 6.98 486 gm.
OPERATING CONDITIONS
Temperature ........................................................-10° to +45° C.
AC Input Voltage ........................... ±10% Rated Line Voltage
Input Frequency ........................................................ 50/60 Hz.
-55G2 option boards
-5 option board
OPTION DESCRIPTION
OPTION SUFFIX
NEMA 4X Enclosure .............................................................-4X
4-20mA isolated signal follower (chassis only) .................-5*
-5 option with Auto/Manual function ................................-7
Decel equals Accel time ..................................................... -17B
Forward-Off-Reverse manual switch
(center blocked, no Dynamic Brake–enclosed only
Forward-Off-Reverse manual switch (center blocked, no
Dynamic Brake - chassis only) ...................................... -29B
Torque control (enclosed only) ......................................... -34A
Isolated voltage follower
(
120/240 VAC input) - controls speed from any external grounded or ungrounded signal: 0-5 VDC thru 0-250 VDC adjustable
(chassis only) ................................................................ -55G2*
-55G2 option with Auto/Manual function ..................-56G2
Other options are available, please consult factory for your requirement.
* Field installable 1–Enclosed version is factory installed only. Chassis version is fi eld
installed.
) .......-29