Dart Controls 13DVA Instruction Manual

MODEL 13DVA Rev.A / 15DVA Rev.A HOOK-UP
WARNING
IMPROPER INSTALLATION OR OPERATION OF THIS CONTROL MAY RESULT IN INJURY TO PERSONNEL OR ELECTRONIC FAILURE. THE
CONTROL MUST BE INSTALLED AND GROUNDED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL SAFETY CODES. AT NO TIME
SHOULD THE CIRCUIT CONTINUITY BE CHECKED BY SHORTING TERMINALS WITH A SCREWDRIVER OR OTHER METAL DEVICE.
PLEASE READ COMPLETELY BEFORE MAKING ANY ADJUSTMENTS
HOOK-UP & TERMINAL IDENTIFICATION
1) Before attempting to wire the control, make sure all power is turned off.
AC lines should be fused for 240 VAC input.
CAUTION SHOULD BE USED IN SELECTING THE SIZE OF HOOK-UP WIRING. LIMIT THE VOLTAGE DROP THROUGH THE WIRING TO 5% OF
THE LINE VOLTAGE AT FULL LOAD.
3) +ARM: Connect to plus (+) Armature wire on motor. 0-90 VDC for 120 VAC input, and 0-180 VDC for 240 VAC input.
4) -ARM: Connect to minus (-) Armature wire on motor.
5) -FIELD: Connect to minus (-) Field wire of Shunt Wound Motor.
6) AC1 and AC2: 120 VAC - Connect incoming hot AC (black wire) to AC1 and neutral (white wire) to AC2
240 VAC - Connect both hot sides, one to AC1 and one to AC2.
7) +FIELD: Do not use for permanent magnet motor. This supplies +Field voltage for a Shunt Wound Motor. For motors
with dual voltage field (ie; 50/100V or 100/200V), make sure the highest value is connected.
CAUTION: DO NOT ATTEMPT TO PERFORM A HI-POT TEST ACROSS AC LINES WITH CONTROL IN CIRCUIT.
THIS WILL RESULT IN IMMEDIATE OR LONG TERM DAMAGE TO THE CONTROL.
1) Preset trimpots in the counter-clockwise (CCW) position.
ADJUSTMENTS
2) Apply power.
3) Rotate the Speedpot fully CW and adjust MAX trimpot in the CW direction until the maximum desired
speed is obtained.
4) Rotate the Speedpot fully counter-clockwise (CCW) and adjust the MIN trimpot in the CW
direction until deadband or the minimum desired speed is obtained.
5) The IR COMP trimpot is used as a regulation adjustment. If better motor regulation is needed between minimum and maximum loads, then
adjust IR COMP trimpot as follows. Rotate the Speedpot CW to the 50% position and rotate the IR COMP trimpot CW as needed to increase
regulation.
6) Recheck and readjust trimpots if necessary. Trimpot interaction with each other will be minimal.
SPEEDPOT HI
SPEEDPOT WIPER
SPEEDPOT LO
MIN
IR COMP
SPEEDPOT LO
(orange wire)
SPEEDPOT WIPER
(red wire)
SPEEDPOT HI
(white wire)
TO REMOTE
SPEEDPOT
MIN
IR COMP
-TS OPTION
+ARM
-ARM
-FIELD
AC2
AC1
MAX
+FIELD
A-1-2718B-A
LT01
MAX
+ARM
-ARM
-FIELD
AC2
AC1
+FIELD
HEATSINK DIMENSIONS & IDENTIFICATION
.592
.140
.216
2.500 +/-.050
2.055.240
.318 .178
1.261
C
L
.203
.377 DIA. (1 HOLE)
2.126
2.326
.140 DIA.
(2 PLACES)
.750
.230
1 or 1A HOUSING*
(SIDE PROFILE)
2 or 2A HOUSING*
13DVA Rev.A /15DVA Rev.A MODEL SPECIFICATIONS
AC Input Voltage .............................................................................................. ± 10% Rated Line Voltage
Amps - DC Output ........................................................................................................ 150mA to 2 Amps
Dimensions ............................................................. 13DV1 / 15DV1: 2.80" wide, 1.30" high, 3.30" deep
Dimensions ............................................................. 13DV2 / 15DV2: 2.80" wide, 1.50" high, 3.30" deep
Input Frequency ..................................................................................................................... 50 / 60 Hertz
Input Voltage - 13DV .................................................................................................... 12 VAC or 24 VAC
Input Voltage - 15DV ................................................................................................. 120 VAC or 240 VAC
I.R. Compensation ................................................................................................. Adjustable - full range
Max. Speed .................................................................................... Adjustable (40 - 120% of Base Speed)
Min. Speed .................................................................................................... Adjustable (0 - 30% of Max)
Output Voltage - 13DV (12 or 24 VAC Input) .................................................................. 0-12 or 0-24 VDC
Output Voltage - 15DV (120 or 240 VAC Input) .......................................................... 0-105 or 0-210 VDC
Overload Capacity ........................................................................................................ 200% for 1 minute
Shunt Field Voltage - 13DV ..................................................................... 1 Amp max, 10 VDC at 12 VAC
Shunt Field Voltage - 15DV ..................................................................... 1 Amp max, 20 VDC at 24 VAC
Shunt Field Voltage - 15DV ................................................................. 1 Amp max, 100 VDC at 120 VAC
Shunt Field Voltage - 15DV ................................................................. 1 Amp max, 200 VDC at 240 VAC
Speed Control ........................................................................................... 5K Ohm Speed Potentiometer
Speed Range ........................................................................................................................................ 25:1
Speed Regulation ...................................................................................................... ± 1% of Base Speed
Temperature Range ....................................................................... -10o to 45o C. Ambient (15o to 115o F.)
Transient Protection ........................................................................................................................ G-Mov
Weight .................................................................................................. 13DV1A / 15DV1A weighs 2.64 oz.
Weight .................................................................................................. 13DV2A / 15DV2A weighs 3.03 oz.
With suitable external heatsink, current can be increased to 4 Amps. The 13DV/15DV heatsink temperature
should not exceed 70
o
C. Equivalent to 4" x 4" x 0.125" thick aluminum plate mounted to housing.
A-1-2718B-B
LT01
Loading...