Dart Controls 130 Series Catalog Page

130 Series Reversing Control for PM and Shunt Wound DC Motors through 2 HP
INSTANT REVERSING, QUICK STOPPING, RAPID CYCLING…
The 130 Ser ies reversing cont r o l o u tp er form s o t he r dynamic braking and reversing controls by utilizing Dart’s unique zero-speed detect and dynamic braking circuits. These circuits eliminate the cont act arcing and failed braking problems associated with other reversing and dynamic braking controls. Dart’s zero speed detect circuit also elimin ates motor pl ug reversing problems.
8
www.dartcontrols.com
4.063
130 SERIES STANDARD FEATURES
VAC
VAC
SPEEDPOT
LO
W
HI
SPDT
MOTOR
LO
W
HI
COM
FWD
REV
A2
A1
L
~
N
~
P4
-1
-2
-3
-4
-5
-6
-7
-6
-7
-8
P1
• Adjustable horsepower settings
• Barrier terminal blocks
• Full wave bridge supply
130 SERIES OPERATING CONDITIONS
Temperature ..........................................-10° to +45° C
AC Input Voltage .....................±10% Rated Line Voltage
Input Frequency ............................................50/60 Hz
• Adjustable Min speed (0-30% of max)
• Adjustable Max speed (60-100% of base)
• Adjustable IR compensation
• Adjustable current limit
• Fixed accel (0.5 sec); or 6 sec “soft start” w/(-K) option
• Line voltage compensation
• 5K speed pot with leads, dial and knob included
• 50:1 speed range
• Overload capacity: 200% for one minute
• Transient voltage protection
• Shunt field supply provided (1 Amp max; 100V for 120
TYPICAL APPLICATIONS
• Indexers
• Door Openers
• Feeders
• Tapping Machines
• Pumps
• Screen Presses
• Conveyors
VAC input or 200V for 240 VAC input)
• Onboard dynamic brake resistor
• Automatic dynamic braking on power loss
• 1% speed regulation with armature voltage feedback
• cULus listed - file #78180
130 SERIES MODEL NUMBERS AND RATINGS
INPUT OUTPUT CYCLE MODEL VOLTAGE HP RANGE AMPS DC RATE
130LC12 120 VAC 1/15-1/8 1.2 3 C/MIN 130LC100 120 VAC 1/8-1/2 5.5* 3 C/MIN 130HC12 120 VAC 1/15-1/8 1.2 UP TO 30 C/MIN 130HC100 120 VAC 1/8-1.0 10.0 UP TO 30 C/MIN 132LC25 240 VAC 1/25-1/4 1.2 3 C/MIN 132LC200 240 VAC 1/8-1.0 5.5** 3 C/MIN 132HC25 240 VAC 1/25-1/4 1.2 UP TO 30 C/MIN 132HC200 240 VAC 1/4-2.0 10.0 UP TO 30 C/MIN
* Up to 10 amps continuous output current at 1 Hp 90VDC with suitable external heat sink. ** Up to 10 amps continuous output current at 2 Hp 180VDC with suitable external heat sink.
130 SERIES MECHANICAL SPECIFICATIONS, ADJUSTMENTS AND HOOK-UPS
130 Series HC Models
www.dartcontrols.com
130 Series LC Models
130 Series Hook-up
All dimensions in inches
9
Loading...