TP9000
TP9000
Electronic Programmable Room Thermostat
plus Domestic Hot Water Timer
Please note: This product should only be installed by a
qualifi ed electrician or competent Heating installer, and should
be in accordance with the current edition of the IEEE wiring
regulations.
PL
GR
ES
1.0 Product specifi cation
Specifi cation230V model24V model
Power supply230 Vac, ±15%,
50/60 Hz
Switching action
Unit switch rating230 Vac, 3(1)A24Vac, 3(1)A
Memory BackupRetained for life of product
Heat Temperature Range
Setting
Factory Set Calendar
Clock
2 x SPDT internally linked, Type 1BS
5°C - 30°C
Automatic Summer/Winter time
change
24 Vac, ±15%,
50/60 Hz
Remote Sensor Inputs
(‘A’ models only)
Programme resolution± 1 minute
Timing Accuracy± 1 minute
Dimensions, mm (W, H, D) 135 x 88 x 32mm
Design standardEN 60730-2-7 +EN60730-2-9
Control Pollution Situation
Rated Impulse Voltage 2.5 kV
Ball Pressure Test75°C
Can be set by installer for remote sen-
sor, limited sensor, window contact,
tele-switch or outdoor sensor
Degree 2
4
TP9000
1.1 Installation
• Remove wallplate from unit by unscrewing the two screws on
the bottom edge of the unit.
• From the top left hand corner of the wallplate, there must be
clearances of at least 140 mm to the right, 15mm to the left,
30mm above and 100mm below in order to mount the plug-on
GB
GB
module.
• The wallplate must be securely mounted either directly to the
wall using suitable wood screws or to a fl ush mounted 1-gang
electrical accessory box using M3.5 screws.
• Cable access can either be from behind for concealed cabling, or
from below for surface cabling. If surface cable is used, cut out
cable access slot on plug-on module prior to mounting.
• For wiring connections refer to diagram on page 7.
The TP9000 is double insulated and does not require an earth
connection, however a parking terminal is provided on the
wallplate. This is clearly marked with an Earth symbol.
• Prior to mounting the plug-on module, DIL switches on the
rear of the plug-on module must be set. See diagram below for
available options.
PL
GR
ES
• Mount plug-on module to wallplate by locating tabs on top of
wallplate in apertures on rear of module, hinge down and press
fi rmly to wallplate before tightening securing screws on bottom
of wallplate.
Prior to mounting the unit the 2 DIL switches on the rear of the
unit have to be moved to the required position. The factory
presets are shown below.
Sw. No.
1
2
Keyboard disabled
Reset disabledReset enabled
OFF
ON
Keyboard enabled
Danfoss Heating
5
IMPORTANT: The supply to this unit should by wired via a double
pole isolation switch in accordance with BS EN60730-1, i.e. one
which provides air gaps of at least 3mm in both poles of the mains,
GB
GB
PL
GR
ES
!
and incorporates a 3 amp fuse. It is strongly recommended that solid
conductors be used.
Outline of unit
30mm minimum
C/L
Terminal block
Wall or
Plaster box
fitting
N &
looping
terminals
Clearance for
screwdriver
access
Surface fixed cable
bottom entry knockouts
Rear entry
cable access
Thermostat and Remote Room Sensor:
Fix at a height of approximately 1.5m from the fl oor, away from
draughts or heat sources such as radiators, open fi res or direct
sunlight.
6
TP9000
1.2 Wiring
NOTE:
The 230V TP9000 does not have voltage free contacts, therefore it is
NOT suitable for connection to extra low voltage equipment.
Remote Sensor to be wired with 1mm 2 core double insulated cable
only. Cable length should not exceed 50 metres. Sensor cable should
NOT be run parallel to mains cable.
N-L = 230V
B-C = 24V
(B=0v / C=24v)
GB
GB
PL
GR
ES
B
L
C
N
Remote sensor inputs
The TP9000 incorporates an input which can be used to connect one
of the following:
1) remote room temperature sensor
2) limit sensor, for example, fl oor temperature sensor (sold as
accessory).
3) window contacts, card reader contacts, outdoor sensor (sold as
accessory) or teleswitch contacts.
See Installer Advanced Programming Options for set-up
instructions.
Danfoss Heating
7
GB
GB
PL
Remote sensor inputs
Terminals 5 and 6 are the designated remote sensor inputs. These can
be found on the top right hand side of the wallplate.
5
6
5
6
5
6
GR
ES
Confi gured for
remote room,
limit or outdoor
sensor
Window or
teleswitch
contact
(NO or NC)
Confi gured for
window contact or
other contact such
as teleswitch
Window
contact (NC)
Teleswitch
contact (NC)
Confi gured for
window contact
and other contact
such as teleswitch
8
TP9000
2.0 Installer advanced
programming options
TP9000 incorporates a number of advanced features which can be set
GB
GB
by the user. These are accessed via a User Advanced Programming
Mode, please refer to User Advanced Programming in the user
instructions for details (see page 23)
2.1 Installer advanced programming options
TP9000 incorporates an additional number of advanced features
which can be set by the installer to improve the operating effi ciency
of the system and where required, to change the user functionality
of the product. These are accessed via an Installer Advanced
Programming Mode. These settings are optional and need only be
made if there is a demand for the enhanced functions.
2.2 Service Interval Timer
Instructions on how to access this feature are available from our
PL
GR
ES
customer support desk. Please note these are only issued to boni-fi de
Heating installers.
2.3 Entering Installer Advanced Programming
Mode
To access the Installer Advanced Programming Mode follow the
steps below:
a) Press and hold
to enter User Advanced Programming, the
display will change to fi gure opposite.
b) Press and hold
to enter Installer Advanced Programming, the
display will change to fi gure opposite.
V and PROG for 3 seconds
V, Λ and PROG for 5 seconds
Danfoss Heating
9
c) Use + and - keys to scroll backwards and forwards between
GB
GB
PL
GR
ES
options then
fl ashing digit on the right hand of the display indicates the
number of the selected option. The large characters display the
option value selected.
d) To return to RUN, press and hold PROG until the display returns
to RUN mde.
Option 30 - Set upper limit of temperature range
This allows the upper limit of the thermostat
setting range to be electronically limited. Press +
until Option 30 is displayed, use V and Λ to select
required setting.
Setting40 - 5°C (factory setting is 30°C)
Option 31 - Set lower limit of temperature range
V and Λ keys to change the option settings. The
This allows the lower limit of the thermostat
setting range to be electronically limited. Press +
until Option 31 is displayed, use V and Λ to select
required setting.
Setting5 - 40°C (factory setting is 5°C)
Option 32 - Enable Off at lower limit
This enables an OFF function to be selected if a
set point below the lower limit is selected. Press +
until Option 32 is displayed, use
required setting.
This allows the thermostat to be set to run in On/Off
mode or for a chrono-proportional cycle rate to be
selected. Press + until Option 34 is displayed, use V
and Λ to select required setting.
0On/Off
33 cycles per hour
GB
GB
66 cycles per hour (factory setting)
99 cycles per hour
1212 cycles per hour
Option 35 - Set integration time (Option 34 set to 3, 6, 9 or 12)
(seek advice prior to adjusting)
This adjusts the integration time of the PI
algorithm to increase control accuracy. It is only
active if option 34 has been set to Chrono 3, 6,
9 or 12. It should only be adjusted after seeking
advice from the manufacturer. Press + until
Option 35 is displayed, use
required setting.
2.5Integration time set to 2.5% (factory setting)
5Integration time set to 5%
V and Λ to select
PL
GR
ES
10Integration time set to 10%
Option 36 - Set temperature override rule
This establishes the degree of temperature override
available to the user. Press + until Option 36 is
Option 37 - Set time duration of override rule
(Option 36 set to 1 or 2)
This establishes the duration of a temperature
override available to the user. Press + until Option 37
is displayed, use V and Λ to select required setting.
This sets the thermostat to operate with either 2,
4 or 6 switching events per day or to run it in stat
mode. Press + until option 40 is displayed, use Λ or V to select required setting.
1Stat mode
2Two switching events per day
4Four switching events per day
6Six switching events per day (factory setting)
Option 41 - Operating Mode (Heating) (option 40 set to 2, 4, or 6)
This sets the thermostat to operate using either
5/2 day or 24 hour mode. Press + until option 41 is
displayed, use Λ or V to select required setting.
77 Day programming (factory setting)
5-2 or A-B 5-2 Day programming or A-B programming
2424 hour programming
Option 60 - Number of events per day (Hot Water)
This sets the number of Hot Water on/off switching
times per day. Press + until option 60 is displayed,
use Λ or V to select required setting.
Setting 11 on/off event per day
Setting 22 on/off events per day
Setting 33 on/off events per day (factory setting)
12
TP9000
Option 61 - Hot Water Event - Days per week
This sets the schedule of Hot Water on/off switching
times per week. Press + until Option 61 is displayed,
use V and Λ to select required setting.
2424 Hour
5-2Either 5+2 day or A+B days depending on user APM
setting
GB
GB
77 Day (factory setting)
Option 70 - Keyboard disable rules
This establishes the degree of functionality of the
keyboard available to the user. It is only active if DIL
switch 1 is set to “Disabled”. Press + until Option 70
is displayed, use V and Λ to select required setting.
Option 71 - Random start rules (24V/230 Volt models only)
This enables a random start on power-up following
a power cut to reduce load on the electrical network.
Random delay is in the range of 2 - 90 seconds. Press
PL
GR
ES
+ until Option 71 is displayed, use V and Λ to select
This enables multi-site owners to store a site
reference number in the thermostat. Press + until
Option 72 is displayed, use V and Λ to select
required setting.
Setting Any value between 00 and 99 can be set
Factory setting is 00
Danfoss Heating
13
Option 73 - Owner thermostat reference number
This enables site owners to store a thermostat
reference number in the thermostat. Press +
until Option 73 is displayed, use V and Λ to select
GB
GB
PL
GR
ES
required setting.
Setting Any value between 000 and 999 can be set
Factory setting is 000
Option 74 - Date format for calendar clock
This allows date format to be chosen. Press +
until Option 74 is displayed, use V and Λ to
select required setting.
Setting 0European format (dd/mm/yy), (Factory setting)
Setting 1North American format (mm/dd/yy)
Option 80 - Enable/Disable + Hrs Boost
Enables or disables the +Hrs button. use V and
Λ to select required setting. Press + until Option
80 is displayed, use V and Λ to select required
setting.
Option 93 - Set limit sensor set-point
(option 90 set to 2)
This allows the thermostat limit sensor to be set,
typical application is fl oor Heating. Press + until
Option 93 is displayed, use V and Λ to select
required setting. If the temperature sensed by
the limit sensor exceeds the limit setting the
output will be turned off until the temperature
PL
GR
ES
has dropped by 2°C. “F10” will fl ash in the display
while the output is disabled.
Setting Any value between 20 - 50°C (Factory setting is 27°C)
Option 94 - Confi gure digital input switch type, “A” models only,
(option 90 set to 3)
This allows switch type of digital input to be
confi gured. Press + until Option 94 is displayed,
use V and Λ to select required setting.
Setting 0Contacts NC, open circuit contact to force unit into
thermostat mode, short circuit contacts to return to
normal operation
Setting 1Contacts NO, short circuit contacts to force unit into
thermostat mode, open circuit contacts to return to
normal operation (Factory setting)
Danfoss Heating
15
GB
PL
PL
GR
ES
TP9000
Programowalny termostat pokojowy do układów
C.O. i C.W.U.
programowanych przez instalatora ..................................... 23
16
TP9000
1.0 Podstawowy
Uwaga: Urządzenie to powinno być instalowane jedynie przez
wykwalifi kowanego elektryka lub uprawnionego instalatora
urządzeń grzewczych. Montaż powinien spełniać wymagania
stawiane przez aktualne przepisy Instytutu Inżynierów
Elektryków i Elektroników (IEEE wiring regulations).
Dane techniczneModel 230VModel 24V
GB
PL
PL
Zasilanie230 V~, ±15%,
50/60 Hz
Przełączanie
Dane przełącznika
urządzenia
Podtrzymanie pamięciNa cały okres użytkowania urządzenia
Zakres ustawień tempera-
tury
Zegar kalendarzowy
ustawiony fabrycznie
Sygnały wejściowe ze
zdalnego czujnika (tylko
modele A)
Dwa pojedyncze przełączniki dwupozy-
cyjne, wewnętrznie połączone, typ 1BS
230 V~, 3(1)A24V~, 3(1)A
5°C - 30°C
Automatyczna zmiana czasu z letniego
na zimowy i na odwrót
Mogą być ustawiane przez instalatora dla
zdalnego czujnika, czujnika z ograniczeniem, styku okiennego, teleprzełącznika
lub czujnika zewnętrznego
24 V~, ±15%,
50/60 Hz
GR
ES
Skok czasowy programowania
Dokładność regulatora
czasowego
Wymiary, mm (szerokość,
wysokość, grubość)
Zgodność z normąEN 60730-2-7 +EN60730-2-9
Poziom zakłóceńStopień 2
Znamionowe napięcie
impulsowe
Temperatura próby
twardości metodą Brinella
Danfoss Heating
± 1 minuta
± 1 minuta
135 x 88 x 32mm
2.5 kV
75°C
17
GB
PL
PL
1.1 Montaż
• Zdjąć płytkę ścienną z urządzenia po uprzednim odkręceniu
dwóch śrub na dolnej krawędzi.
• Aby zamontować moduł nasadzany, od górnego lewego rogu
płytki ściennej musi być odstęp co najmniej 140 mm w prawo,
15 mm w lewo, 30 mm w górę i 100 mm w dół.
• Płytka ścienna musi być odpowiednio przymocowana, albo
bezpośrednio do ściany przy pomocy wkrętów do drewna lub
GR
ES
do jednobiegunowej puszki instalacyjnej przy pomocy śrub
M3,5.
• Przewody można podłączyć albo od tyłu (gdy biegną w ścianie),
albo od dołu (gdy nie są schowane). Przed podłączeniem
przewodu znajdującego się na powierzchni ściany należy
wyciąć w module nasadzanym odpowiedni otwór na jego
przeprowadzenie.
• Sposób podłączenia przewodów przedstawiono na diagramie
na stronie 20.
Model TP9000 jest podwójnie izolowany i nie wymaga
uziemienia. Istnieje jednak możliwość podłączenia przewodu
uziemiającego do płytki ściennej – miejsce podłączenia jest
wyraźnie oznaczone symbolem uziemienia.
• Przed zainstalowaniem modułu nasadzanego należy ustawić
przełączniki DIL (dwupozycyjne) z tyłu modułu. Możliwe
warianty pokazano na diagramie poniżej.
• Założyć moduł nasadzany na płytkę ścienną przez wsunięcie
wypustek na górze płytki do otworów z tyłu modułu, obrócić
go do pozycji pionowej i docisnąć mocno do płytki przed
dokręceniem śrub zabezpieczających na dole płytki.
18
TP9000
o Przed zamontowaniem urządzenia przełączniki DIL znajdujące
się z tyłu muszą być ustawione w wymaganym położeniu.
Poniżej pokazano ustawienia fabryczne.
GB
!
Numer przełącznika
Klawiatura nieaktywna
1
Resetowanie nieaktywne resetowanie aktywne
2
Wyłączony
Włączony
klawiatura aktywna
WAŻNE: Zasilanie tego urządzenia powinno odbywać się poprzez
dwuobwodowy przełącznik izolacyjny zgodny z normą BS EN60730-1,
tzn. taki, który tworz y co najmniej trzymilimetrowe szczeliny powietrzne
na obu obwodach (fazowym i zerowym) przewodu zasilającego i
posiada bezpiecznik trzyamperowy. Zaleca się stosowanie przewodów
jednożyłowych.
PL
PL
GR
ES
Minimum 30 mm
Miejsce na
włożenie
śrubokręta
Obrys urządzenia
Miejsce na samodzielnie
wykonywane dolne otwory dla
przewodów zewnętrznych
C/L
Zespół złączy
Otwory na wkręty
mocujące do
ściany lub płyty
gipsowej
Złącza pętlowe N
(zerowe) i uziemienia
Miejsce na podłączenie
przewodów od tyłu
Danfoss Heating
19
GB
PL
PL
GR
ES
Termostat i zdalny czujnik pokojowy:
Zamocować na wysokości około 1,5 m od podłogi, z dala od
ciągów powietrza i źródeł ciepła, takich jak grzejniki i kominki,
oraz miejsc bezpośrednio nasłonecznionych.
1.2 Przewody
UWAGA:
Model 230V TP9000 nie posiada styków beznapięciowych, dlatego
NIE można go podłączać do urządzeń o bardzo niskim napięciu.
Zdalny czujnik powinien być podłączany wyłącznie za pomocą
jednomilimetrowego, dwużyłowego, podwójnie izolowanego
przewodu. Długość przewodu nie powinna przekraczać 50 m.
Przewód czujnika NIE powinien być prowadzony równolegle do
przewodu zasilającego.
Układy elektroniczne
N-L = 230V
B-C = 24V
(B=0v / C=24v)
20
N
B
L
C
Wyłączony
ciepła woda
użytkowa
Wyłączony
ogrzewanie
Włączony
ciepła woda
użytkowa
Włączony
ogrzewanie
Zdalny czujnik
TP9000