Installation Instructions
1.0 Basics
1.0 Product specifi cation ...................................................................4
1.1 Installation .......................................................................................5
1.2 Wiring ................................................................................................7
2.0 Installer advanced programming options
2.1 Installer advanced programming options ...........................9
2.2 Service Interval Timer ..................................................................9
2.3 Entering Installer Advanced Programming Mode ............9
Danfoss Heating
3
GB
GB
1.0 Basics
Please note: This product should only be installed by a qualifi ed electrician or competent Heating installer, and should be in accordance with the current edition of the IEEE wiring regulations.
PL
GR
ES
1.0 Product specifi cation
Specifi cation 230V model 24V model
Power supply 230 Vac, ±15%,
50/60 Hz
Switching action
Unit switch rating 230 Vac, 3(1)A 24Vac, 3(1)A
Memory Backup Retained for life of product
Heat Temperature Range Setting
Factory Set Calendar Clock
2 x SPDT internally linked, Type 1BS
5°C - 30°C
Automatic Summer/Winter time
change
24 Vac, ±15%,
50/60 Hz
Remote Sensor Inputs (‘A’ models only)
Programme resolution ± 1 minute
Timing Accuracy ± 1 minute
Dimensions, mm (W, H, D) 135 x 88 x 32mm
Design standard EN 60730-2-7 +EN60730-2-9
Control Pollution Situ­ation
Rated Impulse Voltage 2.5 kV
Ball Pressure Test 75°C
Can be set by installer for remote sen-
sor, limited sensor, window contact,
tele-switch or outdoor sensor
Degree 2
4
TP9000
1.1 Installation
Remove wallplate from unit by unscrewing the two screws on the bottom edge of the unit.
From the top left hand corner of the wallplate, there must be clearances of at least 140 mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-on
GB
GB
module.
The wallplate must be securely mounted either directly to the wall using suitable wood screws or to a fl ush mounted 1-gang electrical accessory box using M3.5 screws.
Cable access can either be from behind for concealed cabling, or from below for surface cabling. If surface cable is used, cut out cable access slot on plug-on module prior to mounting.
For wiring connections refer to diagram on page 7.
The TP9000 is double insulated and does not require an earth
connection, however a parking terminal is provided on the wallplate. This is clearly marked with an Earth symbol.
Prior to mounting the plug-on module, DIL switches on the rear of the plug-on module must be set. See diagram below for available options.
PL
GR
ES
Mount plug-on module to wallplate by locating tabs on top of wallplate in apertures on rear of module, hinge down and press fi rmly to wallplate before tightening securing screws on bottom of wallplate.
Prior to mounting the unit the 2 DIL switches on the rear of the
unit have to be moved to the required position. The factory presets are shown below.
Sw. No.
1
2
Keyboard disabled
Reset disabled Reset enabled
OFF
ON
Keyboard enabled
Danfoss Heating
5
IMPORTANT: The supply to this unit should by wired via a double pole isolation switch in accordance with BS EN60730-1, i.e. one which provides air gaps of at least 3mm in both poles of the mains,
GB
GB
PL
GR
ES
!
and incorporates a 3 amp fuse. It is strongly recommended that solid conductors be used.
Outline of unit
30mm minimum
C/L
Terminal block
Wall or Plaster box fitting
N & looping terminals
Clearance for screwdriver access
Surface fixed cable bottom entry knockouts
Rear entry cable access
Thermostat and Remote Room Sensor:
Fix at a height of approximately 1.5m from the fl oor, away from
draughts or heat sources such as radiators, open fi res or direct sunlight.
6
TP9000
1.2 Wiring
NOTE:
The 230V TP9000 does not have voltage free contacts, therefore it is NOT suitable for connection to extra low voltage equipment.
Remote Sensor to be wired with 1mm 2 core double insulated cable only. Cable length should not exceed 50 metres. Sensor cable should
NOT be run parallel to mains cable.
N-L = 230V B-C = 24V (B=0v / C=24v)
GB
GB
PL
GR
ES
B
L
C
N
Remote sensor inputs
The TP9000 incorporates an input which can be used to connect one of the following:
1) remote room temperature sensor
2) limit sensor, for example, fl oor temperature sensor (sold as
accessory).
3) window contacts, card reader contacts, outdoor sensor (sold as
accessory) or teleswitch contacts.
See Installer Advanced Programming Options for set-up
instructions.
Danfoss Heating
7
GB
GB
PL
Remote sensor inputs
Terminals 5 and 6 are the designated remote sensor inputs. These can be found on the top right hand side of the wallplate.
5
6
5
6
5
6
GR
ES
Confi gured for
remote room,
limit or outdoor
sensor
Window or
teleswitch
contact
(NO or NC)
Confi gured for window contact or other contact such
as teleswitch
Window
contact (NC)
Teleswitch
contact (NC)
Confi gured for
window contact and other contact such as teleswitch
8
TP9000
2.0 Installer advanced
programming options
TP9000 incorporates a number of advanced features which can be set
GB
GB
by the user. These are accessed via a User Advanced Programming Mode, please refer to User Advanced Programming in the user instructions for details (see page 23)
2.1 Installer advanced programming options
TP9000 incorporates an additional number of advanced features which can be set by the installer to improve the operating effi ciency of the system and where required, to change the user functionality of the product. These are accessed via an Installer Advanced Programming Mode. These settings are optional and need only be made if there is a demand for the enhanced functions.
2.2 Service Interval Timer
Instructions on how to access this feature are available from our
PL
GR
ES
customer support desk. Please note these are only issued to boni-fi de Heating installers.
2.3 Entering Installer Advanced Programming Mode
To access the Installer Advanced Programming Mode follow the steps below:
a) Press and hold
to enter User Advanced Programming, the display will change to fi gure opposite.
b) Press and hold
to enter Installer Advanced Programming, the display will change to fi gure opposite.
V and PROG for 3 seconds
V, Λ and PROG for 5 seconds
Danfoss Heating
9
c) Use + and - keys to scroll backwards and forwards between
GB
GB
PL
GR
ES
options then fl ashing digit on the right hand of the display indicates the number of the selected option. The large characters display the option value selected.
d) To return to RUN, press and hold PROG until the display returns
to RUN mde.
Option 30 - Set upper limit of temperature range
This allows the upper limit of the thermostat setting range to be electronically limited. Press + until Option 30 is displayed, use V and Λ to select required setting.
Setting 40 - 5°C (factory setting is 30°C)
Option 31 - Set lower limit of temperature range
V and Λ keys to change the option settings. The
This allows the lower limit of the thermostat setting range to be electronically limited. Press + until Option 31 is displayed, use V and Λ to select required setting.
Setting 5 - 40°C (factory setting is 5°C)
Option 32 - Enable Off at lower limit
This enables an OFF function to be selected if a set point below the lower limit is selected. Press +
until Option 32 is displayed, use required setting.
Setting 0 Disabled Setting 1 Enabled (factory setting)
Option 33 - Enable On at upper limit
V and Λ to select
This enables an ON function to be selected if a set point above the upper limit is selected. Press +
until Option 33 is displayed, use required setting.
Setting 0 Disabled (factory setting) Setting 1 Enabled
10
V and Λ to select
TP9000
Option 34 - Select On/Off or Chrono-proportional
This allows the thermostat to be set to run in On/Off mode or for a chrono-proportional cycle rate to be selected. Press + until Option 34 is displayed, use V and Λ to select required setting.
0 On/Off 3 3 cycles per hour
GB
GB
6 6 cycles per hour (factory setting) 9 9 cycles per hour
12 12 cycles per hour
Option 35 - Set integration time (Option 34 set to 3, 6, 9 or 12) (seek advice prior to adjusting)
This adjusts the integration time of the PI algorithm to increase control accuracy. It is only active if option 34 has been set to Chrono 3, 6, 9 or 12. It should only be adjusted after seeking advice from the manufacturer. Press + until
Option 35 is displayed, use required setting.
2.5 Integration time set to 2.5% (factory setting) 5 Integration time set to 5%
V and Λ to select
PL
GR
ES
10 Integration time set to 10%
Option 36 - Set temperature override rule
This establishes the degree of temperature override available to the user. Press + until Option 36 is
displayed, use
Setting 0 No limit (factory setting) Setting 1 Limited to ±2°C Setting 2 No override allowed
V and Λ to select required setting.
Danfoss Heating
11
GB
GB
Option 37 - Set time duration of override rule (Option 36 set to 1 or 2)
This establishes the duration of a temperature override available to the user. Press + until Option 37 is displayed, use V and Λ to select required setting.
Setting 0 Next event (factory setting) Setting 1 1 hour
PL
GR
ES
Setting 2 2 hours Setting 3 3 hours Setting 4 4 hours
Option 40 - Number of Events per Day (Heating)
This sets the thermostat to operate with either 2, 4 or 6 switching events per day or to run it in stat mode. Press + until option 40 is displayed, use Λ or V to select required setting.
1 Stat mode 2 Two switching events per day 4 Four switching events per day 6 Six switching events per day (factory setting)
Option 41 - Operating Mode (Heating) (option 40 set to 2, 4, or 6)
This sets the thermostat to operate using either 5/2 day or 24 hour mode. Press + until option 41 is displayed, use Λ or V to select required setting.
7 7 Day programming (factory setting)
5-2 or A-B 5-2 Day programming or A-B programming
24 24 hour programming
Option 60 - Number of events per day (Hot Water)
This sets the number of Hot Water on/off switching times per day. Press + until option 60 is displayed, use Λ or V to select required setting.
Setting 1 1 on/off event per day Setting 2 2 on/off events per day Setting 3 3 on/off events per day (factory setting)
12
TP9000
Option 61 - Hot Water Event - Days per week
This sets the schedule of Hot Water on/off switching times per week. Press + until Option 61 is displayed, use V and Λ to select required setting.
24 24 Hour 5-2 Either 5+2 day or A+B days depending on user APM
setting
GB
GB
7 7 Day (factory setting)
Option 70 - Keyboard disable rules
This establishes the degree of functionality of the keyboard available to the user. It is only active if DIL switch 1 is set to “Disabled”. Press + until Option 70 is displayed, use V and Λ to select required setting.
Setting 0 Normal lock: Programming functions locked (factory
setting)
Setting 1 Full lock: All keys are disabled
Option 71 - Random start rules (24V/230 Volt models only)
This enables a random start on power-up following a power cut to reduce load on the electrical network. Random delay is in the range of 2 - 90 seconds. Press
PL
GR
ES
+ until Option 71 is displayed, use V and Λ to select
required setting.
Setting 0 Disabled (factory setting) Setting 1 Enabled
Option 72 - Owner site reference number
This enables multi-site owners to store a site reference number in the thermostat. Press + until Option 72 is displayed, use V and Λ to select required setting.
Setting Any value between 00 and 99 can be set Factory setting is 00
Danfoss Heating
13
Option 73 - Owner thermostat reference number
This enables site owners to store a thermostat reference number in the thermostat. Press + until Option 73 is displayed, use V and Λ to select
GB
GB
PL
GR
ES
required setting. Setting Any value between 000 and 999 can be set Factory setting is 000
Option 74 - Date format for calendar clock
This allows date format to be chosen. Press + until Option 74 is displayed, use V and Λ to select required setting.
Setting 0 European format (dd/mm/yy), (Factory setting) Setting 1 North American format (mm/dd/yy)
Option 80 - Enable/Disable + Hrs Boost Enables or disables the +Hrs button. use V and
Λ to select required setting. Press + until Option
80 is displayed, use V and Λ to select required setting.
Setting 0 +Hrs Boost button disabled Setting 1 +Hrs Boost button enabled (factory setting)
Option 81 - Thermostat calibration bias
This allows the thermostat calibration to be biased by up to ±1.5°C. Press + until Option 81 is displayed, use V and Λ to select required setting.
Setting Any value between ±1.5 in 0.5°C steps (Factory setting is
0°C)
14
TP9000
Option 90 - Defi ne remote sensor type
This allows type of remote sensor input type to be defi ned. Press + until Option 90 is displayed, use V and Λ to select required setting.
Setting 0 No remote sensor fi tted Setting 1 Remote room or duct sensor fi tted, internal sensor disabled
(factory setting)
GB
GB
Setting 2 Remote limit sensor fi tted, refer to option 93 to defi ne
set-point
Setting 3 Confi gured as digital input for window, card reader or
teleswitch, refer to option 94 to defi ne o/c or s/c.
Setting 4 Outdoor sensor fi tted internal sensor active, outdoor
sensor used for display purposes only
Option 93 - Set limit sensor set-point (option 90 set to 2)
This allows the thermostat limit sensor to be set, typical application is fl oor Heating. Press + until Option 93 is displayed, use V and Λ to select required setting. If the temperature sensed by the limit sensor exceeds the limit setting the output will be turned off until the temperature
PL
GR
ES
has dropped by 2°C. “F10” will fl ash in the display while the output is disabled.
Setting Any value between 20 - 50°C (Factory setting is 27°C)
Option 94 - Confi gure digital input switch type, “A” models only, (option 90 set to 3)
This allows switch type of digital input to be confi gured. Press + until Option 94 is displayed, use V and Λ to select required setting.
Setting 0 Contacts NC, open circuit contact to force unit into
thermostat mode, short circuit contacts to return to normal operation
Setting 1 Contacts NO, short circuit contacts to force unit into
thermostat mode, open circuit contacts to return to normal operation (Factory setting)
Danfoss Heating
15
GB
PL
PL
GR
ES
TP9000
Programowalny termostat pokojowy do układów C.O. i C.W.U.
Instrukcja montażu
1.0 podstawowy
1.0 Instrukcja montażowa .............................................................. 17
1.1 Montaż ........................................................................................... 18
1.2 Przewody .......................................................................................20
2.0 Zaawansowane funkcje programowane
przez instalatora
2.1 Zaawansowane funkcje programowane
przez instalatora ........................................................................ 22
2.2 Wskaźnik czasu następnego przeglądu
serwisowego ................................................................................ 22
2.3 Wejście w tryb zaawansowanych funkcji
programowanych przez instalatora ..................................... 23
16
TP9000
1.0 Podstawowy
Uwaga: Urządzenie to powinno być instalowane jedynie przez wykwalifi kowanego elektryka lub uprawnionego instalatora urządzeń grzewczych. Montaż powinien spełniać wymagania stawiane przez aktualne przepisy Instytutu Inżynierów Elektryków i Elektroników (IEEE wiring regulations).
Dane techniczne Model 230V Model 24V
GB
PL
PL
Zasilanie 230 V~, ±15%,
50/60 Hz
Przełączanie
Dane przełącznika urządzenia
Podtrzymanie pamięci Na cały okres użytkowania urządzenia Zakres ustawień tempera-
tury Zegar kalendarzowy
ustawiony fabrycznie Sygnały wejściowe ze
zdalnego czujnika (tylko modele A)
Dwa pojedyncze przełączniki dwupozy-
cyjne, wewnętrznie połączone, typ 1BS
230 V~, 3(1)A 24V~, 3(1)A
5°C - 30°C
Automatyczna zmiana czasu z letniego
na zimowy i na odwrót
Mogą być ustawiane przez instalatora dla
zdalnego czujnika, czujnika z ogranicze­niem, styku okiennego, teleprzełącznika
lub czujnika zewnętrznego
24 V~, ±15%,
50/60 Hz
GR
ES
Skok czasowy programow­ania
Dokładność regulatora czasowego
Wymiary, mm (szerokość, wysokość, grubość)
Zgodność z normą EN 60730-2-7 +EN60730-2-9 Poziom zakłóceń Stopień 2 Znamionowe napięcie
impulsowe Temperatura próby
twardości metodą Brinella
Danfoss Heating
± 1 minuta
± 1 minuta
135 x 88 x 32mm
2.5 kV
75°C
17
GB
PL
PL
1.1 Montaż
Zdjąć płytkę ścienną z urządzenia po uprzednim odkręceniu
dwóch śrub na dolnej krawędzi.
Aby zamontować moduł nasadzany, od górnego lewego rogu
płytki ściennej musi być odstęp co najmniej 140 mm w prawo, 15 mm w lewo, 30 mm w górę i 100 mm w dół.
Płytka ścienna musi być odpowiednio przymocowana, albo
bezpośrednio do ściany przy pomocy wkrętów do drewna lub
GR
ES
do jednobiegunowej puszki instalacyjnej przy pomocy śrub M3,5.
Przewody można podłączyć albo od tyłu (gdy biegną w ścianie),
albo od dołu (gdy nie są schowane). Przed podłączeniem przewodu znajdującego się na powierzchni ściany należy wyciąć w module nasadzanym odpowiedni otwór na jego przeprowadzenie.
Sposób podłączenia przewodów przedstawiono na diagramie
na stronie 20.
Model TP9000 jest podwójnie izolowany i nie wymaga
uziemienia. Istnieje jednak możliwość podłączenia przewodu uziemiającego do płytki ściennej – miejsce podłączenia jest wyraźnie oznaczone symbolem uziemienia.
Przed zainstalowaniem modułu nasadzanego należy ustawić
przełączniki DIL (dwupozycyjne) z tyłu modułu. Możliwe warianty pokazano na diagramie poniżej.
Założyć moduł nasadzany na płytkę ścienną przez wsunięcie
wypustek na górze płytki do otworów z tyłu modułu, obrócić go do pozycji pionowej i docisnąć mocno do płytki przed
dokręceniem śrub zabezpieczających na dole płytki.
18
TP9000
o Przed zamontowaniem urządzenia przełączniki DIL znajdujące
się z tyłu muszą być ustawione w wymaganym położeniu. Poniżej pokazano ustawienia fabryczne.
GB
!
Numer przełącznika
Klawiatura nieaktywna
1
Resetowanie nieaktywne resetowanie aktywne
2
Wyłączony
ączony
klawiatura aktywna
WAŻNE: Zasilanie tego urządzenia powinno odbywać się poprzez dwuobwodowy przełącznik izolacyjny zgodny z normą BS EN60730-1, tzn. taki, który tworz y co najmniej trzymilimetrowe szczeliny powietrzne na obu obwodach (fazowym i zerowym) przewodu zasilającego i posiada bezpiecznik trzyamperowy. Zaleca się stosowanie przewodów
jednożyłowych.
PL
PL
GR
ES
Minimum 30 mm
Miejsce na włożenie śrubokręta
Obrys urządzenia
Miejsce na samodzielnie wykonywane dolne otwory dla przewodów zewnętrznych
C/L
Zespół złączy
Otwory na wkręty mocujące do ściany lub płyty gipsowej
Złącza pętlowe N (zerowe) i uzie­mienia
Miejsce na podłączenie przewodów od tyłu
Danfoss Heating
19
GB
PL
PL
GR
ES
Termostat i zdalny czujnik pokojowy:
Zamocować na wysokości około 1,5 m od podłogi, z dala od
ciągów powietrza i źródeł ciepła, takich jak grzejniki i kominki, oraz miejsc bezpośrednio nasłonecznionych.
1.2 Przewody
UWAGA:
Model 230V TP9000 nie posiada styków beznapięciowych, dlatego NIE można go podłączać do urządzeń o bardzo niskim napięciu.
Zdalny czujnik powinien być podłączany wyłącznie za pomocą jednomilimetrowego, dwużyłowego, podwójnie izolowanego przewodu. Długość przewodu nie powinna przekraczać 50 m. Przewód czujnika NIE powinien być prowadzony równolegle do przewodu zasilającego.
Układy elektroniczne
N-L = 230V B-C = 24V (B=0v / C=24v)
20
N
B
L
C
Wyłączony
ciepła woda
użytkowa
Wyłączony
ogrzewanie
ączony
ciepła woda
użytkowa
ączony
ogrzewanie
Zdalny czujnik