Danfoss TP9000 Data sheet

Datasheet
TP9000 Programmable Room Thermostat with DHW Time Control
Features
The TP9000 is a programmable room thermostat with remote temperature sensor. The TP9000 allows the user to select up to 6 dierent temperature levels per day and the times which the changes occur.
The TP9000 can be set at installation to operate both heating and hot water independently in either 7 day mode - individual times and temperatures for each day of the week, 5 day/2 day mode, which allows dierent programmes to be set for the weekend, or in 24 hour mode, in which case the programmed events are repeated every 24 hours.
Accessed via the APM (Advanced Programming Menu), settings made by the installer or the end user are stored for the life of the product in a non-volatile memory chip which does not require power.
Using the APM, the operating temperature range, which is factory preset to 5-30°C, can also be preset by the installer for any min/max temperature between 5-40°C. This makes the TP9000 a safe solution for use in sheltered accommodation where hypothermia may be of concern.
For installation convenience, the TP9000 is supplied with a remote room sensor which can be mounted up to 50 metres away from the programming unit.
In addition to the programmable room thermostat function, TP9000 also incorporates a Domestic Hot Water time control channel which allows up to 3 Domestic Hot Water on/o events to be programmed each day.
The TP9000 has the ability to be set in Holiday mode. Using the Holiday mode, the Hot Water is switched o and the Central Heating is placed in frost protection mode. Upon reaching the set holiday return date, normal operation is resumed.
The inclusion of an information button on the unit allows quick viewing of items like the next timed event, service due date (if activated), and outdoor temperature (if outdoor sensor is tted).
Designed to be fully compliant with Part L and Best Practice requirements, the TP9000 is the obvious choice for new and retrot applications.
The TP9000 incorporates convenient user overrides which allows the user to:
l Obtain an extra 1, 2, or 3 hour’s Hot Water or
Central Heating.
l Temporarily override room temperatures up or
down.
l Select Heating and Water O, with frost
protection for periods away from home.
l Up to 6 time/temperature changes per day for
heating.
l Can be set at installation for 24 hour, 5 day/2
day or 7 day operation.
l Remote sensor for installation convenience. l Integrated DHW time control. l Convenient user overrides. l Clear, easy to read LCD display and LED status
indicators.
l Wallplate construction for ease of installation.
© Danfoss HS | 09/2015 | 736v02 VDBYD202
1
Datasheet
Mains Water
TP9000 Programmable Room Thermostat
Application
Specications
Feed &
Expansion Tank
Wiring
Cylinder
Stat
AVDO
Box
Zone Valves
TP9000
Heatplan Control System
Remote
Sensor
Feed &
Expansion Tank
Mains Water
Wiring
Cylinder
Stat
AVDO
Box
Zone Valve
TP9000
Heatshare Control System
TP9000
Code Number 087N789200
Factory set clock
l
Room time and temperature changes up to 6 per day
Room temperature control range (°C) 5-30°C
Remote room temperature sensor
Selectable 7 day, 5/2 day or 24 hour operating mode
Fully independent Hot Water and Central Heating times
l
l
l
DHW time control events up to 3 on/o events per day
Frost protection override option
+1, +2, +3 hour DHW and/or CH override
Room temperature overrides
Holiday mode
l
l
l
l
Event 1 20°C 6:30am
Heating Programme Factory preset times and temperatures for every day in 24 hour mode or Mon-Fri 5/2 day or 7 day mode.
Event 2 15°C 8:30am
Event 3 20°C 11:30pm
Event 4 15°C 1:30pm
Event 5 21°C 4:30pm
Event 6 15°C 10:30pm
Event 1 20°C 7:30am
Heating Programme Factory preset times and temperatures Saturday and Sunday in 5/2 day or 7 day mode.
Event 2 20°C 9:30am
Event 3 20°C 11:30pm
Event 4 20°C 1:30pm
Event 5 21°C 4:30pm
Event 6 15°C 10:30pm
Event 1 On 6:30am
Hot Water Programme Factory preset times for every day in 24 hour mode or Mon-Fri in 5-2 day or 7 day mode
Event 2 O 8:30am
Event 3 On 11:30pm
Event 4 O 1:30pm
Event 5 On 4:30pm
Event 6 O 10:30pm
Event 1 On 7:30am
Hot Water Programme Factory preset times for Saturday and Sunday in 5-2 day or 7 day mode
Event 2 O 9:30am
Event 3 On 11:30pm
Event 4 O 1:30pm
Event 5 On 4:30pm
Event 6 O 10:30pm
Optional service interval operation
l
Voltage rating 230 Vac, 50Hz
Switch action 2 x SPDT (linked internally)
Switch current rating 3 (1) A
Maximum ambient temperature 45°C
Memory back-up Retained for life of product
Dimensions - Controller (mm) 135 wide x 88 high x 32 deep
Dimensions - TS2 Remote Sensor (mm) 61 wide x 45 high x 22 deep
Remote
Sensor
NB All may be changed as required.
NB All may be changed as required.
NB All may be changed as required.
NB All may be changed as required.
2
© Danfoss HS | 09/2015 | 736v02 VDBYD202