Danfoss TMM 070, TMM 084, TMM 089 User guide

Technical Information

Transit Mixer Axial Piston Motor

Size 070/084/089

powersolutions.danfoss.com

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Revision history

Table of revisions

 

 

 

 

 

 

 

Date

Changed

Rev

 

 

 

 

 

June 2017

Update to Engineering Tomorrow

0202

 

 

 

 

 

Mar 2014

Converted to Danfoss layout – DITA CMS

BA

 

 

 

 

 

10 Aug 2012

New TMM images

AD

 

 

 

 

 

15 Feb 2012

TMM detail view added

AC

 

 

 

 

 

20 Jan 2012

Pictures` numbers were added, MMC change.

AB

 

 

 

 

 

08 Dec 2011

First edition

AA

 

 

 

 

2 | © Danfoss | June 2017

L1108123 | BC00000193en-US0202

Technical Information

 

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

 

Contents

 

Revisions

 

Technical Specifications

 

Literature reference ........................................................................................................................................................................

5

General description.........................................................................................................................................................................

5

TMM fixed displacement motor sectional view....................................................................................................................

6

System schematic.............................................................................................................................................................................

6

TMM technical data.........................................................................................................................................................................

7

Output Speed...............................................................................................................................................................................

9

System Pressure...........................................................................................................................................................................

9

Case Pressure................................................................................................................................................................................

9

External Shaft Seal Pressure....................................................................................................................................................

9

Temperature.................................................................................................................................................................................

9

Viscosity........................................................................................................................................................................................

10

Filtration............................................................................................................................................................................................

10

Case Drain.........................................................................................................................................................................................

10

Reservoir............................................................................................................................................................................................

10

Determination of nominal motor sizes..................................................................................................................................

11

High-pressure relief valve (HPRV).............................................................................................................................................

11

Anti-cavitation valve.....................................................................................................................................................................

12

Loop flushing shuttle spool........................................................................................................................................................

12

Loop flushing relief valve............................................................................................................................................................

12

Speed sensor description............................................................................................................................................................

13

Speed and temperature sensor...........................................................................................................................................

13

Sensor PPU, KPP*13808..........................................................................................................................................................

14

Master Model Code

 

TMM master model code............................................................................................................................................................

15

Operation

 

Bearing life........................................................................................................................................................................................

17

Bearing life with no external shaft side load...................................................................................................................

17

External radial shaft loads......................................................................................................................................................

17

Mounting Flange Loads...............................................................................................................................................................

18

Estimating overhung load moments.................................................................................................................................

18

Output shafts...................................................................................................................................................................................

19

Installation drawings

 

Dimensions.......................................................................................................................................................................................

22

© Danfoss | June 2017

L1108123 | BC00000193en-US0202 | 3

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Revisions

4 | © Danfoss | June 2017

L1108123 | BC00000193en-US0202

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Technical Specifications

Literature reference

Further available literature

Title

Type

Literature number

 

 

 

Speed and Temperature Sensor

Technical Information

11046759

 

 

 

Hydraulic Fluids and Lubricants

Technical Information

520L0463

 

 

 

Design Guideline for Hydraulic Fluid Cleanliness

Technical Information

520L0467

 

 

 

TMM Axial Piston Motor

Service Manual

L1211037

 

 

 

General description

This motor is designed primarily to be combined with others pumps in closed circuit system to transfer hydraulic power, especially for Transit Mixer Application.

Innovation with reliable technology

Loop flushing device integrated

High pressure relieve valves integrated

Anti-cavitation valves – optional

Speed and temperature sensor – optional

Speed sensor

Metric / Inch connections

High pressure ports for 3000 and 6000 psi on one side

Sizes: 70 cm3, 84 cm3 and 89 cm3

TMM fixed displacement motor

© Danfoss | June 2017

L1108123 | BC00000193en-US0202 | 5

Danfoss TMM 070, TMM 084, TMM 089 User guide

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Technical Specifications

TMM fixed displacement motor sectional view

TMM cross-sectional view

Loop flushing valve

Anti-cavitation valve

High pressure relieve valve

Valve plate

Piston

Conical bearings

 

 

Output shaft

 

Cylinder block

Fixed swashplate

System schematic

The schematic below shows the function of a hydrostatic transmission using a TMP axial variable displacement pump with electric proportional displacement control (EDC) and a TMM fixed displacement motor with integrated loop flushing device.

6 | © Danfoss | June 2017

L1108123 | BC00000193en-US0202

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Technical Specifications

TMM with TMP EDC

C1

C2

 

 

 

 

 

 

L1

M1

M3

 

 

 

A

 

 

 

 

M5

 

 

 

 

M4

 

 

 

 

 

 

 

 

B

 

M10

S

L2

M2

 

TMP

 

 

 

L1

 

 

 

 

M1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

 

 

L2

M3

M2

 

TMM

 

Legend:

M3 – Charge gage port, after filtering

A, B – System ports

M4, M5 – Servo gage ports

L1, L2 – Case drain ports

M10 – Charge pump inlet pressure port

M1, M2 – System A/B gage ports

S – Charge inlet port

Detailed information about ports see the section Installation drawings, pages Dimensions on page 22.

TMM technical data

General specifications

Design

Axial piston motor with fixed swashplate design with fixed displacement

 

 

Direction of rotation

Bi-directional

 

 

Pipe connections

Main pressure ports: ISO split flange boss

 

 

 

Remaining ports: ISO/SAE straight thread O-ring boss

 

 

Recommended

Motor installation position is discretionary

installation position

The housing must always be filled with hydraulic fluid. .

 

 

W Warning

The front shaft seal must not be exposed to oil pressure from outside of the unit.

© Danfoss | June 2017

L1108123 | BC00000193en-US0202 | 7

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Technical Specifications

Technical data

Features

Unit

Size

 

 

 

 

 

 

 

 

 

070

084

089

 

 

 

 

 

Displacement maximum

cm3

68.3

83.8

89.0

 

[in3]

[4.17]

[5.11]

[5.43]

Flow at rated (continuous) speed

l/min

171

209.5

222.5

 

[US gal/min]

[45.2]

[55.3]

[58.8]

 

 

 

 

 

Torque (theoretical)

N•m/bar

1.09

1.33

1.42

 

[lbf•in/1000 psi]

[665]

[812]

[867]

 

 

 

 

 

Mass moment of inertia of

kg•m2

0.0209

0.0209

0.0209

rotating components

[lbf•ft2]

[0.0159]

[0.0159]

[0.0159]

Weight dry (standard)

kg

34.8

34.8

34.8

 

[lb]

[76.9]

[76.9]

[76.9]

 

 

 

 

 

Oil volume

l [US gal]

2 [0.53]

2 [0.53]

2 [0.53]

 

 

 

 

 

Mounting flange

SAE ISO 3019/1 flange 127-4 (SAE C), M12x1,75

 

 

 

 

 

Output shaft

Spline shaft SAE, 21 teeth, pitch = 16/32

 

 

 

Spline shaft SAE, 23 teeth, pitch = 16/32

 

 

 

 

 

Main port configuration

Twin ports SAE J518b Size 1, with metric or inch screws

 

 

 

 

 

Case drain ports L1, L2

M22x1,5 (O-ring boss) or 7/8–14 UNF-2B

 

 

 

 

Other ports

ISO straight thread O-ring boss or SAE. See Installation drawings, page

 

Dimensions on page 22.

 

 

 

 

 

 

 

Operating parameters

Features

 

Unit

070/084/089

 

 

 

 

Output speed

Minimum

min-1 (rpm)

100

 

Rated

 

2500

 

 

 

 

 

Maximum

 

2900

 

 

 

 

System pressure

Max. working pressure

bar

420 [6090]

 

 

[psi]

 

 

 

Maximum pressure

450 [6525]

 

 

 

 

 

 

 

Minimum pressure

 

10 [145]

 

 

 

 

 

Case pressure

Rated

bar

3.0

[44]

 

 

[psi]

 

 

 

Maximum

5.0

[73]

 

 

 

 

 

 

 

Lip seal external pressure

Maximum

 

0.4

[5.8]

 

 

 

 

 

Fluid specifications

Features

 

Unit

070/084/089

 

 

 

 

Viscosity

Intermittent 1

mm2/s [SUS]

5 [42]

 

Minimum

 

7 [49]

 

 

 

 

 

Recommended range

 

12-80 [66-370]

 

 

 

 

 

Maximum

 

1600 [7500]

 

 

 

 

Temperature

Minimum (cold start) 3

°C [°F]

-40 [-40]

range 2

 

 

 

Recommended range

 

60-85 [140-185]

 

 

 

 

 

 

 

Rated

 

104 [220]

 

 

 

 

 

Maximum intermittent 1

 

115 [240]

8 | © Danfoss | June 2017

L1108123 | BC00000193en-US0202

Technical Information

TMM Transit Mixer Axial Piston Motor, Size 070/084/089

Technical Specifications

Fluid specifications (continued)

Features

 

Unit

070/084/089

 

 

 

 

Filtration

Cleanliness per ISO 4406

 

22/18/13

(recommended

 

 

 

Efficiency (charge pressure filtration)

β-ratio

β15-20 = 75 (β10 ≥ 10)

minimum)

 

 

 

 

 

Efficiency (suction and return line filtration)

 

β35-45 = 75 (β10 ≥ 2)

 

 

 

 

 

 

 

Recommended inlet screen mesh size

µm

100 – 125

 

 

 

 

 

1

Intermittent = Short term t < 1 min per incident and not exceeding 2 % of duty cycle based load-life

2

At the hottest point, normally case drain port

 

 

3

Cold start = Short term t < 3 min, p ≤ 50 bar [725 psi], n ≤ 1000 min-1(rpm)

 

 

 

 

 

 

Output Speed

Minimum speed is the lowest output speed. Operating below minimum speed limits the system can be unstable.

Rated speed is the highest input speed recommended at full power condition. Operating at or below this speed should yield satisfactory product life.

Maximum speed is the highest operating speed permitted. Exceeding maximum speed reduces product life and can cause loss of hydrostatic power and braking capacity. Never exceed the maximum speed limit under any operating conditions.

System Pressure

Maximum working pressure is the highest recommended application pressure; and it is not intended to be a continuous pressure. Propel systems with application pressures at, or below, this pressure should yield satisfactory unit life given proper component sizing.

Maximum pressure is the highest allowable application pressure under any circumstance. Application pressures above maximum working pressure will only be considered with duty cycle analysis and factory approval.

Minimum pressure must be maintained under all operating conditions to avoid cavitation.

Case Pressure

Under normal operating conditions, the rated case pressure must not be exceeded. During cold start, case pressure must be kept below maximum intermittent case pressure.

External Shaft Seal Pressure

In certain applications, the input shaft seal may be exposed to external pressures.

The shaft seal is designed to withstand an external pressure up to 0.4 bar [5.8 psi] above the case pressure.

The case pressure limits must also be followed to ensure the shaft seal is not damaged.

Temperature

High temperature limits apply at the inlet port of the motor. The motor should run at or below the maximum continuous temperature.

Cold oil generally does not affect the durability of motor components. It may affect the ability of oil to flow and transmit power. For this reason, keep the temperature at 16°C

[60 °F] above the pour point of the hydraulic fluid.

Minimum (cold start) temperature relates to the physical properties of component materials. Maximum continuous temperature is the allowed temperature at which normal life can be expected.