Danfoss TLY5.7KK.3 Data sheet

TLY5.7KK.3
102H
4642
TLY5.7KK.3
R600a
SUCTION CONNECTOR
8538-2
DANFOSS COMPRESSORS
Barcode on white background
Yellow background
Red stripe
Approvals
Application
8122
R600a
Yellow warning label
157
66
60.5
102
96
117
29
71
51°
20°
45°
170
178
70
100
ø16
186
204
ø9
35
105
107
105
B
A
30°
31.5°
28°
176
222
C
D
E
8244
High Energy-optimized Compressor R600a 220-240V 50Hz
General
Code number
Compressors on pallet
Application
Application
Frequency Hz
Evaporating temperature
Voltage range
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short)
°C -35 to -10
V 198 - 254
°C 60 (70)
°C 125 (135)
102H4642
125
LBP
50 60
Cooling requirements
Frequency Hz
Application
32°C S
38°C S
43°C S
Remarks on application:
Motor
Motor type
LRA (rated after 4 sec. UL984), HST | LST
Cut in Current, HST | LST
Resistance, main | start winding (25°C)
Design
Displacement
Oil quantity (type)
Maximum refrigerant charge
Free gas volume in compressor
Weight without electrical equipment
Dimensions
Height
Suction connector location/I.D. mm | angle
Process connector location/I.D. mm | angle
Discharge connector location/I.D. mm | angle
Oil cooler connector location/I.D. mm | angle
Connector tolerance I.D. mm
Remarks:
December 2005 DEHC.ED.520.Y1.02 1/2
50 60
LBP MBP HBP LBP MBP HBP
RSIR/RSCR
A 2.3
A 6.3
35.0 21.0
3
cm
3
cm
180 (mineral)
g 150
3
cm
kg 6.8
mm A 163
B 159
B1
B2
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
C 6.2 | 30°
D 6.2 | 31.5°
E 5.0 | 28°
material | comment Cu-plated steel | Al caps
F
material | comment
±0.09, on 5.0 +0.12/+0.20
S = Static cooling normally sufficient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufficent – = not applicable in this area
5.70
1690
EN 12900 Household (CECOMAF) 220V, 50Hz, 2 W PTC consumption incl., static cooling
8223
N
N
L
C
S
b
d
a1
e
a1
Winding protector
Start winding
Main winding
e
g
pos.2
8217
N
N
L
C
b
d
a1
a1
Winding protector
Start winding
Main winding
g
pos.1
Evap. temp. in °C
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W
-45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
36.4 50.7 68.0 74.7 89.0 114 144
49.7 57.9 66.0 68.8 74.3 83.1 92.8
0.41 0.43 0.46 0.47 0.49 0.52 0.55
0.73 0.87 1.03 1.09 1.20 1.37 1.55
EN 12900 Household (CECOMAF) 220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W
-45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
36.4 50.7 68.0 74.7 89.0 114 144
48.5 56.3 64.0 66.7 71.9 80.3 89.5
0.26 0.27 0.28 0.29 0.30 0.31 0.33
0.75 0.90 1.06 1.12 1.24 1.42 1.61
ASHRAE LBP 220V, 50Hz, 2 W PTC consumption incl., static cooling
Evap. temp. in °C
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W
-45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
44.6 62.0 83.2 91.3 109 139 175
49.9 57.9 65.9 68.6 74.0 82.7 92.3
0.41 0.43 0.46 0.47 0.49 0.52 0.55
0.89 1.07 1.26 1.33 1.47 1.68 1.90
ASHRAE LBP 220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W
-45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
44.6 62.0 83.2 91.3 109 139 175
48.6 56.3 63.9 66.5 71.7 79.9 89.1
0.26 0.27 0.28 0.29 0.30 0.31 0.33
0.92 1.10 1.30 1.37 1.52 1.74 1.97
Accessories TLY5.7KK.3 Figure Code number Test conditions EN 12900/CECOMAF ASHRAE
PTC starting device 6.3 mm spade connectors
PTC starting device 6.3 mm spade connectors
ePTC starting device 4.8 mm spade connectors
Cover
Cord relief
Run capacitor 4 µF (optional)
Protection screen for PTC
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 DEHC.ED.520.Y1.02 December 2005
4.8 mm spade connectors
4.8 mm spade connectors
6.3 mm spade connectors
4.8 mm spade connectors
a1
(pos.1)
a1
(pos.2)
b 103N2010
d 103N1010 Mounting accessories Code number
e
g 103N0476 Snap-on in quantities Ø: 16 mm 118-1919
103N0011 Condensing temperature 55°C 54.4°C
103N0018 Ambient temperature 32°C 32°C
103N0016 Suction gas temperature 32°C 32°C
103N0021 Liquid temperature no subcooling 32°C
103N0050
117-7117 Bolt joint for one compressor Ø: 16 mm 118-1917
117-7119 Bolt joint in quantities Ø: 16 mm 118-1918
Loading...