High Energy-optimized Compressor R600a 220-240V 50Hz
General
Code number 102H4542
Approvals EN 60335-2-34 with Annex AA
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S
38°C S
43°C S
Remarks on application:
Motor
Motor type RSIR/RSCR
LRA (rated after 4 sec. UL984), HST | LST A 1.8
Cut in Current, HST | LST A 6.1
Resistance, main | start winding (25°C) 39.0 18.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 6.8
Dimensions
Height mm A 163
Suction connector location/I.D. mm | angle C 6.2 | 30°
Process connector location/I.D. mm | angle D 6.2 | 31.5°
Discharge connector location/I.D. mm | angle E 5.0 | 28°
Oil cooler connector location/I.D. mm | angle F
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
December 2004 DEHC.ED.520.L1.02 1/2
LBP MBP HBP LBP MBP HBP
3
3
3
180 (mineral)
B 159
B1
B2
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment
S = Static cooling normally sucient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sucent – = not applicable in this area
4.78
1690
EN 12900 Household (CECOMAF) 220V, 50Hz, 2 W PTC consumption incl., static cooling
8223
N
N
L
C
S
b
d
a1
e
a1
Winding protector
Start winding
Main winding
e
g
pos.2
8217
N
N
L
C
b
d
a1
a1
Winding protector
Start winding
Main winding
g
pos.1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 27.5 40.0 55.0 60.7 72.9 94.2 119
Power cons. in W 39.6 46.4 53.0 55.3 59.8 67.1 75.1
Current cons. in A 0.31 0.33 0.36 0.37 0.38 0.41 0.44
COP in W/W 0.70 0.86 1.04 1.10 1.22 1.40 1.59
EN 12900 Household (CECOMAF) 220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 27.5 40.0 55.0 60.7 72.9 94.2 119
Power cons. in W 38.8 45.5 52.0 54.2 58.7 65.8 73.6
Current cons. in A 0.21 0.22 0.24 0.25 0.26 0.28 0.31
COP in W/W 0.71 0.88 1.06 1.12 1.24 1.43 1.62
ASHRAE LBP 220V, 50Hz, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 33.9 49.0 67.2 74.3 89.1 115 146
Power cons. in W 39.7 46.4 52.9 55.2 59.6 66.8 74.7
Current cons. in A 0.31 0.33 0.36 0.36 0.38 0.41 0.44
COP in W/W 0.85 1.06 1.27 1.35 1.49 1.72 1.95
ASHRAE LBP 220V, 50Hz, RC 4µF, 2 W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 33.9 49.0 67.2 74.3 89.1 115 146
Power cons. in W 39.0 45.5 51.9 54.1 58.5 65.5 73.2
Current cons. in A 0.21 0.22 0.24 0.25 0.26 0.28 0.31
COP in W/W 0.87 1.08 1.30 1.37 1.52 1.76 1.99
Accessories TLY4.8KK.3 Figure Code number Test conditions EN 12900/CECOMAF ASHRAE
PTC starting device 6.3 mm spade connectors
PTC starting device 6.3 mm spade connectors
ePTC starting device 4.8 mm spade connectors 103N0050
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Run capacitor 4 µF (optional)
Protection screen for PTC g 103N0476 Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 DEHC.ED.520.L1.02 December 2004
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
4.8 mm spade connectors 103N0021 Liquid temperature no subcooling 32°C
6.3 mm spade connectors
4.8 mm spade connectors 117-7119 Bolt joint in quantities Ø: 16 mm 118-1918
a1
(pos.1)
a1
(pos.2)
e
103N0011 Condensing temperature 55°C 54.4°C
103N0016 Suction gas temperature 32°C 32°C
117-7117 Bolt joint for one compressor Ø : 16 mm 118-1917