TLX8.7KK.3
High Energy-optimized Compressorr
R600a
220-240V 50Hz
General
Code number 102H4947
Approvals EN 60335-2-34 with Annex AA
Compressors on pallet 125
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 60 (70) –
Max. winding temperature continuous (short) °C 105 (115) –
Cooling requirements
Frequency Hz 50 60
Application
32°C S – – – – –
38°C S – – – – –
43°C S – – – – –
Remarks on application:
Motor
Motor type RSCR
LRA (rated after 4 sec. UL984), HST | LST A – 3.6
Cut in Current, HST | LST A – 8.4
Resistance, main | start winding (25°C) Ω 19.0 13.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 8.3
Dimensions
Height mm A 173
Suction connector location/I.D. mm | angle C 6.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 169
B1 –
B2 –
8.67
180 (mineral)
1790
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
February 2011 Manufactured by Secop for Danfoss - DEHC.ED.520.O4.02 / 520N1330 1/2

EN 12900 Household (CECOMAF) 220V, 50Hz, RC 4μF, ePTC consumption incl., static cooling
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 64.8 87.9 115 125 146 184 227
Power cons. in W 65.7 76.9 87.7 91.4 98.7 110 123
Current cons. in A 0.33 0.37 0.42 0.44 0.47 0.53 0.59
COP in W/W 0.99 1.14 1.31 1.37 1.48 1.66 1.84
ASHRAE LBP 220V, 50Hz, RC 4μF, ePTC consumption incl., static cooling
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 78.8 107 140 152 178 224 276
Power cons. in W 65.7 76.9 87.7 91.4 98.7 110 123
Current cons. in A 0.33 0.37 0.42 0.44 0.47 0.53 0.59
COP in W/W 1.20 1.39 1.59 1.66 1.81 2.02 2.24
Accessories for TLX8.7KK.3 Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0021 Ambient temperature 32°C 32°C
a1
103N0016 Condensing temperature 55°C 55°C
ePTC starting device 4.8 mm spade connectors 103N0050 Suction gas temperature 32°C 32°C
Cover b 103N2010 Liquid temperature no subcooling 32°C
Cord relief d 103N1010
Run capacitor 4 µF 6.3 mm spade connectors
(compulsory) 4.8 mm spade connectors 117-7119 Bolt joint for one comp. Ø : 16 mm 118-1917
e
117-7117 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint in quantities Ø : 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.520.O4.02 / 520N1330 June 2012