TLS7F Standard Compressor R134a 220-240V 50Hz
General
Code number 102G4720
Approvals EN 60335-2-34 w. Annex AA
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S
38°C S
43°C
Remarks on application: run capacitor 4 µF compulsory in 38°C ambient temperature
Motor
Motor type RSIR/RSCR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.7 5.4
Cut in Current, HST | LST A 5.7 9.7
Resistance, main | start winding (25°C) 14.5 14.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 7.5
Dimensions
Height mm A 173
Suction connector location/I.D. mm | angle C 6.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 169
B1
B2
6.49
180 (polyolester)
1790
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.H3.02 / 520N1374 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 66 89 120 133 160 208 264
Power cons. in W 97 116 136 143 158 182 207
Current cons. in A 0.87 0.91 0.96 0.98 1.03 1.11 1.20
COP in W/W 0.68 0.77 0.88 0.92 1.01 1.14 1.28
ASHRAE LBP 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 81 109 148 163 197 256 326
Power cons. in W 97 116 136 143 158 182 207
Current cons. in A 0.87 0.91 0.96 0.98 1.03 1.11 1.20
COP in W/W 0.84 0.94 1.09 1.14 1.24 1.41 1.57
Accessories for TLS7F Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0021 Liquid temperature no subcooling 32°C
a1
(pos. 1)
a1
(pos. 2)
103N0011 Condensing temperature 55°C 54.4°C
103N0016 Suction gas temperature 32°C 32°C
Starting relay 6.3 mm spade connectors a2 117U6000
Start capacitor 60 µF 6.3 mm spade connectors c 117U5014 Mounting accessories Code number
Cover b 103N2010 Bolt joint for one comp. Ø: 16 mm 118-1917
Cord relief d 103N1010 Bolt joint in quantities Ø: 16 mm 118-1918
Run capacitor 6.3 mm spade connectors
4 µF (optional) 4.8 mm spade connectors 117-7119
e
117-7117 Snap-on in quantities Ø: 16 mm 118-1919
Protection screen for PTC g 103N0476
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.H3.02 / 520N1374 June 2012