Danfoss RAW 5215, RAW 5216, RTD 5215, RTD 5216 Data sheet

Data Sheet
Thermostatic Radiator Sensor, Type RAW with RTD Connection
Application
Ordering and Technical Data
The sensors are equipped with RTD connection.
RAW 5216 is identical to 5215 except for the temperature range 16 - 28 °C.
The RAW 5215 sensor incorporates a frost protection setting for maximum user flexibility.
RAW/RTD 5215/5216
The RAW series is a programme of radiator thermostats which covers all central and district heating systems.
RAW is a self-actuating proportional controller with a small P-band.
RAW radiator thermostats are designed for use in 2-pipe domestic heating systems.
Sensor range
Product Model Colour
RAW 5215 Built-in temperature sensor RAL 9016 8-28 °C 013G5215 RAW 5216 Built-in temperature sensor, limited temperature area RAL 9016 16-28 °C 013G5216
The RAW sensors also provide the option to limit the temperature range. On 013G5215 both maximum and minimum setting temperature can be limited. On 013G5216 only the maximum temperature can be limited.
The RAW design is particularly robust, with both End-Stop strength limits and sensor bending force limits being substantially above the requirements of the European Standard EN215.
Temp.
range
1)
Code no.
1)
Xp = 2 K. (The valve closes at 2 °C higher room temperature)
Accessories and Spare
Product Code no.
Parts
Theft protection 013G5287
Danfoss Heating Solutions VDFNP202 © Danfoss 03/2011 1
*
10 14 18 22 26 30 °C
*
8 12 16 20 24 28 °C
1
2
3
4
5
. . . . . .
Data Sheet Thermostatic Radiator Sensor, Type RAW with RTD Connection
Temperature Setting
Mounting
The required room temperature is set by turning the setting dial. The temperature scales show the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room temperature will often be influ-enced by installation conditions.
1. 2.
= Frost protection setting
The temperature scales are stated according to European standards at Xp = 2°C. This means that
the radiator thermostats close at a sensor temperature which is 2°C higher than stated on the temperature scales.
3. 4.
An open-end spanner is used for mounting the sensor onto the valve body (1 & 2). The sensor should always be placed where the room air can circulate freely around it.
RAW5215 only
Setting the upper and lower limit
The thermostat features two tabs with which the temperature setting area can be decreased. If 4 should be max. setting, turn the thermostat to max. position (3) and press and hold right tab while turning the thermostat to 4 (3), now release tab. With the left tab the lower temperature must be turned to min. position (4).
2 VDFNP202 © Danfoss 03/2011 Danfoss Heating Solutions