Data Sheet
Thermostatic Radiator Sensor, Type RAW
Application
RAW 5010 RAW 5012 with remote sensor
The raw series is a programme of radiator thermostats which covers all central and district heating systems.
RAW is a self-acting proportional controller with a
small P-band.
RAW radiator thermostats are designed for use in
2-pipe domestic heating systems. They are equipped with snap connection.
The RAW sensor incorporates a frost protection
setting for maximum user flexibility, and provides
also the option to limit the temperature range.
The RAW desig is particularly robust, with both
End-Stop strength limits and sensor bending
force limits being substantially above the requirements of the European Standard EN215.
Approved to EN 215
Coefficient de Variation
Thermostatic sensors RAW are manufactured to the highest standards, and are approved to the European standard EN 215.
RAW 5010: Vt = 0,29 K
Temporelle
Ordering and Specifications
Danfoss Heating Solutions VDIDD102 © Danfoss 02/2013 1
Type Version Colour
RAW 5010 Built-in sensor RAL 9016 8-28 °C 013G5010
RAW 5012
1)
Xp= 2K (the valve closes at 2 °C higher room temperature)
2)
The remote sensor is equipped with 2 m of ultra-thin capillary tube, which is coiled up within the
remote sensor housing. After sensor mounting capillary tube is pulled out to the required length.
Remote sensor 0-2 m
2)
Setting range
1)
Code no.
013G5012
10 14 18 22 26 30 °C
*
8 12 16 20 24 28 °C
1
2
3
4
5
. . . . . .
Data Sheet Thermostatic Radiator Sensor, Type RAW
Setting the Temperature
Mounting
The required room temperature is set by turning
the setting dial. The temperature scales show the
correlation between scale values and the room
temperature. The temperature values stated are
for guidance only as the obtained room temperature will often be influenced by installation conditions.
The temperature scales are stated according to
European standards at Xp = 2°C. This means that
the radiator thermostats close at a sensor temperature which is 2°C higher than stated on the
temperature scales.
= Frost protection setting
Setting the upper and lower limit
The thermostat features two tabs with which the
temperature setting area can be decreased. If 4
should be max. setting, turn the thermostat to
max. position (3) and press and hold right tab
while turning the thermostat to 4 (3), now release
tab. With the left tab the lower temperature must
be turned to min. position (4).
The mounting of the sensor onto the valve is simply and is carried out without the use of tools.
Place the sensor onto the valve and push and it
snaps onto the valve.
Removing the sensor, the ring back is to be
turned to activate the mechanisme again. How
to mount the sensor is described on the packagage of the product..
The snapp ring fixes the sensor automatically
onto the valve. The snapp mechnisme is active
ex works and ready for mounting.
2 VDIDD102 © Danfoss 02/2013 Danfoss Heating Solutions