Danfoss RAW 5010, RAW 5012 Data sheet

Data Sheet
Thermostatic Radiator Sensor, Type RAW
Application
RAW 5010 RAW 5012 with remote sensor
The raw series is a programme of radiator ther­mostats which covers all central and district heat­ing systems.
RAW is a self-acting proportional controller with a small P-band.
The RAW sensor incorporates a frost protection setting for maximum user flexibility, and provides also the option to limit the temperature range.
The RAW desig is particularly robust, with both End-Stop strength limits and sensor bending force limits being substantially above the require­ments of the European Standard EN215.
Approved to EN 215
Coefficient de Variation
Thermostatic sensors RAW are manufac­tured to the highest standards, and are ap­proved to the European standard EN 215.
RAW 5010: Vt = 0,29 K
Temporelle
Ordering and Specifica­tions
Danfoss Heating Solutions VDIDD102 © Danfoss 02/2013 1
Type Version Colour RAW 5010 Built-in sensor RAL 9016 8-28 °C 013G5010 RAW 5012
1)
Xp= 2K (the valve closes at 2 °C higher room temperature)
2)
The remote sensor is equipped with 2 m of ultra-thin capillary tube, which is coiled up within the
remote sensor housing. After sensor mounting capillary tube is pulled out to the required length.
Remote sensor 0-2 m
2)
Setting range
1)
Code no.
013G5012
*
10 14 18 22 26 30 °C
*
8 12 16 20 24 28 °C
1
2
3
4
5
. . . . . .
Data Sheet Thermostatic Radiator Sensor, Type RAW
Setting the Temperature
Mounting
The required room temperature is set by turning the setting dial. The temperature scales show the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room tempera­ture will often be influenced by installation con­ditions.
The temperature scales are stated according to European standards at Xp = 2°C. This means that
the radiator thermostats close at a sensor tem­perature which is 2°C higher than stated on the temperature scales.
= Frost protection setting
Setting the upper and lower limit
The thermostat features two tabs with which the temperature setting area can be decreased. If 4 should be max. setting, turn the thermostat to max. position (3) and press and hold right tab while turning the thermostat to 4 (3), now release tab. With the left tab the lower temperature must be turned to min. position (4).
The mounting of the sensor onto the valve is sim­ply and is carried out without the use of tools. Place the sensor onto the valve and push and it snaps onto the valve.
Removing the sensor, the ring back is to be turned to activate the mechanisme again. How to mount the sensor is described on the pack­agage of the product..
The snapp ring fixes the sensor automatically onto the valve. The snapp mechnisme is active ex works and ready for mounting.