Logic Elements Technical Information
Spool Type
HLEA10-CPC
OPERATION
The HLEA10-CPC is a 10-size, high pressure, normally-closed,
pilot-to-close, spring biased dierential-sensing logic
element that includes an adjustable compensator feature. It
will modulate ow from 1 to 2 based on the spring control
pressure, inlet pressure at port 1, and pilot pressure at port 3.
APPLICATION
Common applications include load-sensing bypass compensator for a xed displacement
pump with single or multiple actuators as well as bypass-type pressure-compensated ow
control. Eective use of logic elements is a key to designing cost-eective circuits, and is
limited only by the imagination of the designer.
SPECIFICATION
Rated Pressure* 350 bar [5075 psi]
Rated Flow at 7 bar
[100 psi]
Weight 0.29 kg [0.64 lbs]
Cavity SDC10-3S
* Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles).
80 l/min
[21.1 US gal/min]
PERFORMANCE CURVE
SCHEMATIC
Theoretical Performance
BC332375783111en-000101 • February 2020
LE - 17
Logic Elements Technical Information
Spool Type
HLEA10-CPC
DIMENSION
mm [in]
1
EXAMPLE CIRCUITS
Cross-sectional view
7/8-14 UNF
25.4 mm [1.00]
68-75 Nm
3
[50-55 lbf*ft]
2
46.8
[1.84]
19.1 mm [.75]
4.1-5.4 Nm
[36-48 lbf*in]
80.0 MAX
[3.15]
6.4 mm [.25]
Double Acng Cylinder with Proporonal Speed
Control, Unloading Valve and Circuit Relief
ORDERING
INFORMATION
BC332375783111en-000101 • February 2020
Proporonal Bypass Flow Control
Dump and Relief Valve for a Fixed Pump
LE - 18