Danfoss Fan Drive HIC Technical Information

Fan Drive HIC Technical Information
P108 319E
A
B
GP
T
P108 311E
GT
GP
T
Quick Reference
Fan Drive HICs Model No. Description Flow Pressure Page
RFDE-40-000 Fan Drive HIC with
Reversing Control
10 - 40 l/min
[2.6 - 10.5 US gal/min]
[3000 psi]
FD - 5
RFDE-80-000 20 - 80 l/min
[5.3 - 21.1 US gal/min]
Fan Drive HICs Model No. Description Flow Pressure Page
RFD-120-000 Fan Drive HIC with
A
Reversing Control
Up to 120 l/min
[31.7 US gal/min]
See performance chart
[3000 psi]
[3000 psi]
FD - 5
FD - 7
P
B
Fan Drive HICs Model No. Description Flow Pressure Page
RFDE-40-PRV Fan Drive HIC with
Proportional and
Reversing Control
RFDE-80-PRV 20 - 80 l/min
10 - 40 l/min
[2.6 - 10.5 US gal/min]
[5.3 - 21.1 US gal/min]
[3000 psi]
[3000 psi]
FD - 9
FD - 9
Fan Drive HICs Model No. Description Flow Pressure Page
RFD-120-PRV Fan Drive HIC with
Proportional and
Reversing Control
P
Up to 120 l/min
[31.7 US gal/min]
See performance chart
[3000 psi]
FD - 11
BC332376063114en-000101 • February 2020
GT
FD - 1
Fan Drive HIC Technical Information
Application notes
OVERVIEW
Variable pump fan drive circuits:
- Provide reversing control and over-
pressure protection/anti-cavitation
Fixed pump fan drive circuits:
- Provide modulating and reversing
control with over-pressure protection/
anti-cavitation
O-highway mobile machinery OEMs and distributors can choose from six pre­engineered Hydraulic Integrated Circuits (HICs) designed to provide speed control and reversing for hydraulic modulating fan drive motors in open circuit hydraulic fan drive systems. The program includes:
40, 80, and 120 LPM Frame Sizes
Variable piston pump or xed pump circuits
Over-Pressure Protection / Anti-Cavitation is standard
Viton O-rings are standard
40 & 80 LPM 120 LPM
RFDE-40-000 & RFDE-80-000 RFD-120-000
RFDE-40-PRV & RFDE-80-PRV RFD-120-PRV
Functions
Proportional relief valve:
– Regulates fan speed by controlling pressure drop across fan motor – Normally closed to ensure full fan speed in the absence of electrical signal – PLUS+1® compliant
Piloted directional control valve:
– Reverses ow to the fan motor to reverse fan direction – Open transition spool reduces pressure spikes during reversals – Sized to minimize parasitic losses due to pressure drop
Dual shock valve with anti-cavitation checks:
– Trims the maximum motor torque by absorbing pressure spikes (shock eects) at
the work ports
– Anti-cavitation feature allows additional ow to the motor through the tank port
when motor overruns the pump
– PVLP shock valves (from PVG) allow for a compact design
Custom designs available upon request
BC332376063114en-000101 • February 2020
FD - 2
Circuits - Variable Pump or Fixed Pump
Fan Drive HIC Technical Information
Application notes
RFDE-40-000, RFDE-80-000 & RFD-120-000
Variable Pump fan drive circuits
HIC provides reversing control and over-pressure protection/anti-cavitation
Variable pump provides modulation (speed control)
Features
Proportional Fan Speed Control:
– Electronically match fan speed with cooling demand – Conserve engine power and fuel for the majority of operating conditions - as
compared to non-proportional systems
Increased design exibility:
– The compact HIC valve can be placed in the most suitable location on the machine – Minimize fan system pressure losses when choosing the optimal fan drive HIC size
for the application
– Internal and external reversing pilot options available (40 LPM & 80 LPM ) – Drain port included on all models for motor case drain – Robust IP69K Deutsch coil standard for all three sizes
Increased productivity:
– Fan is reversible to purge (de-clog) coolers and radiators – Prevents overheating with purged cooler – More power available for useful work when radiator is not clogged
RFDE-40-PRV, RFDE-80-PRV & RFD-120-PRV
Fixed Pump fan drive circuits
HIC provides modulating and reversing control with over-pressure protection/anti-cavitation
BC332376063114en-000101 • February 2020
FD - 3
Fan Drive HIC Technical Information
Application notes
Features (continued)
Automatic cleaning sequence programmed using PLUS+1™:
– Manual or automatic activation – Reference Danfoss Power Solutions ‘Fan Drive Application Block’ information
Custom designs available upon request
Service screen below illustrates an example reversing fan drive software setup
BC332376063114en-000101 • February 2020
FD - 4
Loading...