Danfoss ECtemp Next Plus Data sheet

0 (0)
Danfoss ECtemp Next Plus Data sheet

Data Sheet

ECtemp Next Plus

All room thermostats are used for room temperature control in electric floor heating systems.

By controlling room temperature in accordance with the temperature desired by the user, the room thermostats provide optimal energy savings while upholding optimal thermal comfort in the room.

YEAR

WARRANTY Product

Product specifications

Benefits

Supply voltage/ Output voltage

85–250 V AC, 50/60 Hz

• Modern design with white backlight

Operating room temperature

5 - 35° C

• AWAY function

 

 

Operating floor temperature

5 - 45° C *

• Child safety lock

 

 

Ambient temperature

-10 - 60° C

 

 

• 3 selectable temperature control modes

 

 

Fault indication

Yes

• Maximum floor temperature limitation

 

 

Hysteresis

1° C, symmetrical around the setpoint

• Optional room temperature display

temperature

 

• Frost protection mode

 

 

LCD backlight

Yes, white

• Temperature calibration

 

 

Max. load, inductive

< 3 A

 

 

• Advanced programmable timer.

 

 

Max. load, resistive

< 16 A

 

 

 

 

 

 

 

 

Temperature calibration

Yes (+/-10° C)

Approvals:

 

 

Power consumption

2 W

 

 

 

 

 

 

 

 

Power supply

85–250 V AC, 50/60 Hz

 

 

 

 

 

 

Sensor, floor

NTC 15K accuracy: ±1%

 

 

 

 

 

 

 

 

 

 

Shell material

ABS, non-inflammable

Standard compliance

 

 

IP class

30

• EN/IEC60800:2009

 

 

Approval

CE marking, EN 60730

 

 

 

 

 

 

 

 

Colour

White RAL9010/Dark Grey RAL7024

 

 

 

 

 

 

Dimensions

86 × 86 × 16.0 mm

Types

Item no.

Product Type

Programmable

EAN no.

 

 

 

 

088L0121

ECtemp Next Plus

Yes

5703466233979

 

 

 

 

Connection scheme

NTC

 

S2 S1

N N L L

Max.

16(1)A L 85-250 VAC Wire sensor N

NTC, 15 kOhm@25°C

<![if ! IE]>

<![endif]>86.0

<![if ! IE]>

<![endif]>50.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86.0

 

 

16.0

 

24.5

 

 

50.0

 

 

 

* It will be possible to set the maximum floor temperature up to 45° C. Furthermore, it will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor.

Please contact Danfoss how to extend the maximum floor temperature and set the only room temperature control mode.

IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35° C.

Electrical heating · ©Danfoss

AI92386472451en-010304