Danfoss ECtemp Next Plus Data sheet

NTC, 15 kOhm@25°C
50.0
50.0
86.0
Data Sheet
ECtemp Next Plus
All room thermostats are used for room temperature control in electric floor heating systems.
By controlling room temperature in accordance with the temperature desired by the user, the room thermostats provide optimal energy savings while upholding optimal thermal comfort in the room.
YEAR
WARRANTY
Product
Product specifications
Benefits
• Modern design with white backlight
• AWAY function
• Child safety lock
• 3 selectable temperature control modes
• Maximum floor temperature limitation
• Optional room temperature display
• Frost protection mode
• Temperature calibration
• Advanced programmable timer.
Approvals:
Standard compliance
• EN/IEC60800:2009
Types
Supply voltage/ Output voltage 85–250 V AC, 50/60 Hz
Operating room temperature 5 - 35° C
Operating floor temperature 5 - 45° C *
Ambient temperature -10 - 60° C
Fault indication Yes
Hysteresis
LCD backlight Yes, white
Max. load, inductive < 3 A
Max. load, resistive < 16 A
Temperature calibration Yes (+/-10° C)
Power consumption 2 W
Power supply 85–250 V AC, 50/60 Hz
Sensor, floor NTC 15K accuracy: ±1%
Shell material ABS, non-inflammable
IP class 30
Approval CE marking, EN 60730
Colour White RAL9010/Dark Grey RAL7024
Dimensions 86 × 86 × 16.0 mm
1° C, symmetrical around the setpoint temperature
Item no. Product Type Programmable EAN no.
088 L0121 ECtemp Next Plus Yes 5703466233979
Connection scheme
NTC
Wire sensor
* It will be possible to set the maximum floor temperature up to 45° C. Furthermore, it will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor.
Please contact Danfoss how to extend the maximum floor temperature and set the only room temperature control mode.
IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35° C.
Electrical heating · ©Danfoss AI92386472451en-010304
NNNLL
Max.
L
16(1)A
85-250 VAC
86.0
24.516.0
Loading...