Data Sheet
ECtemp Next Plus
All room thermostats are used for room temperature control in electric floor heating systems.
By controlling room temperature in accordance with the temperature desired by the user, the room thermostats provide optimal energy savings while upholding optimal thermal comfort in the room.
YEAR
WARRANTY Product
Product specifications
Benefits |
Supply voltage/ Output voltage |
85–250 V AC, 50/60 Hz |
||
• Modern design with white backlight |
Operating room temperature |
5 - 35° C |
||
• AWAY function |
|
|
||
Operating floor temperature |
5 - 45° C * |
|||
• Child safety lock |
|
|
||
Ambient temperature |
-10 - 60° C |
|||
|
|
|||
• 3 selectable temperature control modes |
|
|
||
Fault indication |
Yes |
|||
• Maximum floor temperature limitation |
||||
|
|
|||
Hysteresis |
1° C, symmetrical around the setpoint |
|||
• Optional room temperature display |
||||
temperature |
||||
|
||||
• Frost protection mode |
|
|
||
LCD backlight |
Yes, white |
|||
• Temperature calibration |
|
|
||
Max. load, inductive |
< 3 A |
|||
|
|
|||
• Advanced programmable timer. |
|
|
||
Max. load, resistive |
< 16 A |
|||
|
|
|||
|
|
|
|
|
|
|
Temperature calibration |
Yes (+/-10° C) |
|
Approvals: |
|
|
||
Power consumption |
2 W |
|||
|
|
|||
|
|
|
|
|
|
|
Power supply |
85–250 V AC, 50/60 Hz |
|
|
|
|
|
|
|
|
Sensor, floor |
NTC 15K accuracy: ±1% |
|
|
|
|||
|
|
|||
|
|
|
|
|
|
|
Shell material |
ABS, non-inflammable |
|
Standard compliance |
|
|
||
IP class |
30 |
|||
• EN/IEC60800:2009 |
|
|
||
Approval |
CE marking, EN 60730 |
|||
|
|
|||
|
|
|
|
|
|
|
Colour |
White RAL9010/Dark Grey RAL7024 |
|
|
|
|
|
|
|
|
Dimensions |
86 × 86 × 16.0 mm |
Types
Item no. |
Product Type |
Programmable |
EAN no. |
|
|
|
|
088L0121 |
ECtemp Next Plus |
Yes |
5703466233979 |
|
|
|
|
Connection scheme
NTC |
|
S2 S1 |
N N L L |
Max.
16(1)A L 85-250 VAC Wire sensor N
NTC, 15 kOhm@25°C
<![if ! IE]> <![endif]>86.0 |
<![if ! IE]> <![endif]>50.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
86.0 |
|
|
16.0 |
|
24.5 |
|
|
50.0 |
|
|
|
* It will be possible to set the maximum floor temperature up to 45° C. Furthermore, it will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor.
Please contact Danfoss how to extend the maximum floor temperature and set the only room temperature control mode.
IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35° C.
Electrical heating · ©Danfoss |
AI92386472451en-010304 |