Danfoss BB, BE, BF, BG, BN Data sheet

Data Sheet
Solenoid coil Type BB, BE, BF, BG and BN
The Clip-on coils are available for the entire range of Danfoss solenoid valves
The coils are specially designed to operate in the aggressive environment of high humidity and temperature uctuations that you nd in most refrigeration systems.
The Clip-on fastening system ensures a faultless installation and makes the coils easy to mount and dismount. A Danfoss Clip-on coil can be mounted without any tools at all, and it is simple to dismount the coil by means of a screwdriver.
The Clip-on coils are available for the entire range of Danfoss solenoid valves for refrigeration, freezing and air conditioning purposes.
Features
• Encapsulated coils with long operating life, even under extreme conditions.
• Standard coils for AC or DC.
• Standard coils available with 3-core cable, terminal box or DIN plugs.
• Standard coils from 12 V to 420 V, 50, 60 or 50/60 Hz.
• Standard coils dimensioned for max. opening dierential pressure (MOPD) of up to 38 bar.
• Coils can be tted without the use of tools.
AI237186440089en-000802
Data
Solenoid coil type
1m 3-core
cable
Terminal box
DIN spade
and
protection
cap
DIN spade
1m 3-core
cable
Terminal
box
DIN spade
and
protection
cap
DIN spade
Terminal box IP67
BFBEBGBGBEBBBFBEBEBBBN
Enclosure
IP67
IP67
IP67
IP67
IP20
IP00
IP67
IP67
IP20
IP00
IP67
Polution de­gree
44443344333
Conductor area [mm2]
0.75
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
Cable size [mm]
Ø6.6
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.6
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Rated im­pulse volt­age [kV], if altitude < 4000 m
44444444444
Humidity [R.H.]
0 − 100%
0 − 100%
0 − 100%
0 − 100%
0 − 97%
non-con­densation condition
0 − 97%
non-con­densation condition
0 − 100%
0 − 100%
0 − 97%
non-con­densation condition
0 − 97%
non-con­densation condition
0 − 100%
Type of con­trol
11111111111
Safety clas-
sication
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Max. alti­tude above sea level [m]
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
Solenoid coil, Type BB, BE, BF, BG, and BN
Product specication
Technical data
Table 1: Solenoid coil type
NOTE:
For DIN plug, impulse withstand voltage is 3.1 kV for 2000 m < Altitude < 4000 m
Connection
3-core cable
The external thread in the screwed cable entry suits exible steel hose or corresponding cable protection (3 x 0.75 mm2).
Terminal box
Leads are connected to terminal screws in the terminal box. The box is tted with a Pg 13.5 screwed entry for 6 - 14 mm cable. Max. lead cross section: 2.5 mm2.
DIN plugs
The three pins on the coil can be tted with spade tabs, 6.3 mm wide (to EN175301-803A). The two current carrying pins can also be tted with spade tabs, 4.8 mm wide. Max. lead cross section: 1.5 mm2. Use of the protective cap supplied will prevent inadvertent contact with live parts.
DIN socket
(to EN175301-803A) Leads are connected in the socket. The socket is tted with a Pg 11 screwed entry for 6 - 12 mm.
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 2
94
Danfoss M18F03
45
57
47
71
57
45
46
86
51
45
57
47
28
110
45
57
68
Solenoid coil, Type BB, BE, BF, BG, and BN
Dimension and weight
Figure 1: Terminal box 10 W , Weight 0.29 Kg
Figure 2: Cable 10 W , Weight 0.29 Kg
Figure 3: DIN socket 10 W , Weight 0.24 Kg
Figure 4: Terminal box 12 - 20 W , Weight 0.55 Kg
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 3
Type
Valve type
Tambient
[°C]
Supply voltage
[V]
Voltage
variation
Frequency
[Hz]
Power consumption
Code no.
[W]
[VA]
BF024AS
EVR 2 – EVR 40
(NC)
EVR 6 – EVR 22
(NO)
EVRH 10 – EVR
40 EVRC EVRA
EVRAT
EVRS / EVRST
EVM (NC)
-40T80
24
-15%, +10%
501220
018F6257
BF230AS
-40T80
230
-15%, +10%
501222
018F6251
-40T80
220
-15%, +10%
501120
BF240AS
-40T80
240
-15%, +10%
501119
018F6252
BF400AS
-40T80
380 / 400
±10%501021018F6253
BF024BS
-40T80
24
-15%, +10%
601425
018F6265
BF115CS
-40T80
115
-15%, +10%
601322
018F6260
-40T80
100
-15%, +10%
501119
BF220BS
-40T80
220
-15%, +10%
601423
018F6264
BF110CS
-40T50 110
±10%5015
29
018F6280
110
±10%6013
23
BF230CS
-40T50
220 – 230
±10%5016
31
018F6282
220 - 230
±10%6014
24
Solenoid coil, Type BB, BE, BF, BG, and BN
Ordering
Figure 5: BF solenoid coil with 1m 3-core cable IP67
Table 2: Ordering for BF solenoid coil with 1m 3-core cable IP67
Figure 6: BE solenoid coil with terminal box IP67
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 4
Type
Valve type
Tambient
[°C]
Supply voltage
[V]
Voltage
variation
Frequency
[Hz]
Power consumption
Code no.
[W]
[VA]
BE012AS
EVR 2 – EVR 40
(NC)
EVR 6 – EVR 22
(NO)
EVRH 10 – EVRH
40 EVRC EVRA
EVRAT
EVRS / EVRST
EVM (NC)
-40T80
12
-15%, +10%
501018
018F6706
BE024AS
-40T80
24
-15%, +10%
501221
018F6707
BE042AS
-40T80
42
-15%, +10%
501021
018F6708
BE048AS
-40T80
48
-15%, +10%
501021
018F6709
BE115AS
-40T80
115
-15%, +10%
501119
018F6711
BE230AS
-40T80
230
-15%, +10%
501222
018F6701
-40T80
220
-15%, +10%
501119
BE240AS
-40T80
240
-15%, +10%
501119
018F6702
BE440CS
-40T80
380 – 400
-15%, +10%
501323
018F6703
440
-15%, +10%
601424
BE440AS
-40T80
420
-15%, +10%
501121
018F6704
BE024BS
-40T80
24
-15%, +10%
601425
018F6715
BE115CS
-40T80 100
-15%, +10%
501119
018F6710
115
-15%, +10%
601322
BE220BS
-40T80
220
-15%, +10%
601323
018F6714
BE240CS
-40T80
200
-15%, +10%
501120
018F6713
-40T80
240
-15%, +10%
601525
BE110CS
-40T50
110
±10%5015
28
018F6730
-40T50
110
±10%6013
22
BE230CS
-40T50
220 - 230
±10%5017
31
018F6732
220 - 230
±10%6014
24
Type
Valve type
Tambient
[°C]
Supply
voltage
[V]
Voltage
variation
Frequency
[Hz] Power consumption
Code no.
[W]
[VA]
BG024AS
EVR 3 – EVR 40
EVRC EVRA
EVRAT
EVRS/EVRST
EVM (NC/NO)
-40T80
24
-15%, +10%
501121
018F6807
BG048AS
-40T80
48
-15%, +10%
501226
018F6809
BG110AS
-40T80
110
-15%, +10%
501325
018F6811
BG230AS
-40T80
230
-15%, +10%
501528
018F6801
-40T80
220
-15%, +10%
501325
BG240AS
-40T80
240
-15%, +10%
501325
018F6802
BG400AS
-40T80
380 / 400
-15%, +10%
501226
018F6803
BG024BS
-40T80
24
-15%, +10%
601226
018F6815
BG110BS
-40T80
110
-15%, +10%
601629
018F6813
BG220BS
-40T80
220
-15%, +10%
601629
018F6814
Solenoid coil, Type BB, BE, BF, BG, and BN
Table 3: Ordering for BE solenoid coil with terminal box IP67
NOTE:
See „Opening dierential pressure“ under „Technical data“ for the valve concerned. When replacing a coil with terminal box, it is sucient to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap.
Figure 7: BG solenoid coil with terminal box IP67
Table 4: Ordering for BG solenoid coil with terminal box IP67
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 5
Type
Valve type
Tambient
[°C]
Supply
voltage
[V]
Voltage
variation
Frequency
[Hz] Power consumption
Code no.
[W]
[VA]
BG012DS
EVR 2 – 8
EVR 25 – 40
EVRA 3 – EVRA 15 (NC)
EVRA 25 – EVRA 40 (NC)
EVRAT 10 – EVRAT 15 (NC)
EVRS/EVRST 3 –
EVRS/EVRST 15
EVM (NC/NO)
-40T5012±10%DC20–018F6856
BG024DS
-40T5024±10%DC16–018F6857
BG048DS
-40T5048±10%DC20–018F6859
BG110DS
-40T50
110
±10%DC16–018F6860
BG115DS
-40T50
115
±10%DC19–018F6861
BG220DS
-40T50
220
±10%DC20–018F6851
BG012DS
EVR 10 – 22
EVRC 15 – 20
EVRC 20
EVRA 20 EVRAT 20 EVRST 20
-40T5012±10%DC20–018F6886
BG024DS
-40T5024±10%DC20–018F6887
BG048DS
-40T5048±10%DC20–018F6889
BG110DS
-40T50
110
±10%DC20–018F6890
BG220DS
-40T50
220
±10%DC20–018F6881
Type
Valve type
Tambient
[°C]
Supply voltage
[V]
Voltage varia‐
tion
Frequency
[Hz]
Power consumption
Code no.
[W]
[VA]
BE024AS
EVR 2 – EVR 40
(NC)
EVR 6 – EVR 22
(NO)
EVRH 10 – EVRH
40 EVRC EVRA
EVRAT
EVRS/EVRST
EVM (NC)
-40T80
24
-15%, +10%
501221
018F6182
BE230AS
-40T80
230
-15%, +10%
501222
018F6176
-40T80
220
-15%, +10%
501119
BE240AS
-40T80
240
-15%, +10%
501119
018F6177
BE420AS
-40T80
420
-15%, +10%
501021
018F6179
BE115CS
-40T80
100
-15%, +10%
501119
018F6185
-40T80
115
-15%, +10%
601322
BE220BS
-40T80
220
-15%, +10%
501323
018F6189
BE110CS
-40T50
110
±10%5015
28
018F6192
-40T50
110
±10%6013
22
BE230CS
-40T50
220-230
±10%5017
31
018F6193
-40T50
220-230
±10%6014
24
Solenoid coil, Type BB, BE, BF, BG, and BN
NOTE:
See „Opening dierential pressure“ under „Technical data“ for the valve concerned. When replacing a coil with terminal box, it is sucient to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap.
Figure 8: BE solenoid coil with DIN spade and protection cap IP20
Table 5: Ordering for BE solenoid coil with DIN spade and protection cap IP20
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 6
Type
Valve type
Tambient
[°C]
Supply voltage
[V]
Voltage varia‐
tion
Frequency
[Hz]
Power consumption
Code no.
[W]
[VA]
BB024AS
EVR 2 – EVR 40
(NC)
EVR 6 – EVR 22
(NO)
EVRH 10 – EVRH
40 EVRC EVRA
EVRAT
EVRS/EVRST
EVM (NC)
-40T80
24
-15%, +10%
501119
018F7358
BB115AS
-40T80
115
-15%, +10%
501119
018F7361
BB230AS
-40T80
220 - 230
-15%, +10%
501119
018F7351
BB240AS
-40T80
240
-15%, +10%
501119
018F7352
BB024BS
-40T80
24
-15%, +10%
601423
018F7365
BB110CS
-40T50 110
±10%5015
28
018F7360
110
±10%6013
22
BB230CS
-40T50
220 - 230
±10%5016
31
018F7363
220 - 230
±10%6013
24
Type
Valve type
Tambient
[°C]
Supply voltage
[V]
Voltage varia‐
tion
Frequency
[Hz]
Power consumption
Code no.
(1)
)
[W]
[VA]
BN024AS
EVR 2 – EVR 40
(NC)
EVR 6 – EVR 22
(NO)
EVRH 4 – EVRH
40
EVRC/EVRA/
EVRAT/
EVRS/
EVRST/EVM (NC)
-40T50
24
-15%, +10%
502449
018F6904
BN024BS
-40T50
24
-15%, +10%
602242
018F6906
BN230AS
-40T50
230
-15%, +10%
501943
018F6905
Solenoid coil, Type BB, BE, BF, BG, and BN
Figure 9: BB solenoid coil with DIN spade*)
Table 6: Ordering for BB solenoid coil with DIN spade*)
*) Can only be used with DIN plug
NOTE:
See „Opening dierential pressure“ under „Technical data“ for the valve concerned. When replacing a coil with terminal box, it is sucient to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap.
Figure 10: BN special solenoid coil with terminal box IP67
Table 7: Ordering for BN special solenoid coil with terminal box IP67
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 7
Type
Description
Code no.
Terminal box
With built-in light emitting indicator diode for sole­noid valves
018Z0089 DIN plug
Enclosure IP65, EN 175301-803A
042N0156
Solenoid coil, Type BB, BE, BF, BG, and BN
(1)
(1)
Recommended use for EVRH with high MOPD (38 bar).
Recommended use for EVRH with high MOPD (38 bar).
Figure 11: Coil with DIN plug
Table 8: Ordering for Coil with DIN plug
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 8
Document name
Document type
Document topic
Approval authority
RMRS 19.10034.262
Marine - Safety Certicate
-
RMRS
Solenoid coil, Type BB, BE, BF, BG, and BN
Certicates and declaration
The list contains all certicates, declarations, and approvals for this product type. Individual code number may have some or all of these approvals, and certain local approvals may not appear on the list.
Some approvals may change over time. You can check the most current status at danfoss.com or contact your local Danfoss representative if you have any questions.
Table 9: Certicates, declarations, and approvals
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 9
Online support
Danfoss oers a wide range of support along with our products, including digital product information, software, mobile apps, and expert guidance. See the possibilities below.
The Danfoss Product Store
The Danfoss Product Store is your one-stop shop for everything product related—no matter where you are in the world or what area of the cooling industry you work in. Get quick access to essential information like product specs, code numbers, technical documentation, certications, accessories, and more. Start browsing at store.danfoss.com.
Find technical documentation
Find the technical documentation you need to get your project up and running. Get direct access to our ocial collection of data sheets, certicates and declarations, manuals and guides, 3D models and drawings, case stories, brochures, and much more.
Start searching now at www.danfoss.com/en/service-and-support/documentation.
Danfoss Learning
Danfoss Learning is a free online learning platform. It features courses and materials specically designed to help engineers, installers, service technicians, and wholesalers better understand the products, applications, industry topics, and trends that will help you do your job better.
Create your Danfoss Learning account for free at www.danfoss.com/en/service-and-support/learning.
Get local information and support
Local Danfoss websites are the main sources for help and information about our company and products. Find product availability, get the latest regional news, or connect with a nearby expert—all in your own language.
Find your local Danfoss website here: www.danfoss.com/en/choose-region.
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order conrmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, t or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 10
Loading...