Danfoss Bi-Directional Installation guide

INSTRUCTION
HOME Radiator Thermostat Bi-Directional valve with flow- selectable feature
Installation of valve
The valve is a bi-directional valve and can be installed horizontally or vertically in either the flow or return pipe.
A built in flow direction selection feature can be used to eliminate the risk of water hammer.
1, Close all radiator valves by turning the valve cover cap clockwise. Leave system to cool.
2, Start boiler/heating. 3, Open one valve and deter-
Troubleshooting
In the unlikely event of water hammer being encountered turn the setting ring (see diagram 4) to the other setting. Alternatively if commissioning the whole system, establish the flow direction through each valve using the diagrams below.
If the flow direction needs to be changed there is no need to remove the valve, simply turn the setting ring.
mine flow direction. Which pipe heats first?
4, Remove cap and turn setting ring according to the drawings. The setting ring is turned by hand only.
Note: Maximum pressure drop should not exceed
0.45 bar
© Danfoss HS | 2019.07| VIMQC202 | 013R9672
5, Repeat step 3 and 4 until all valves have been set correctly. Sensor may now be fitted or the valve cap temporarily refitted.
1
Installation Guide User Guide
Danfoss can a ccept no responsib ility for possi ble errors in cat alogues, broc hures and other pri nted material. Dan foss reserves th e right to alter its pr oducts witho ut notice. This also a pplies to product s already on orde r provided that suc h alterations can b e made without sub sequential chan ges being necess ary in specic ations already a greed. All tradem arks in this mater ial are propert y of the respec tive companies. D anfoss and all Danfo ss logotypes a re trademark s of Danfoss A/S. Al l rights reserv ed.
Danfoss Limited
Heating Segment heating.danfoss.co.uk +44 (0)330 808 6888
E-mail: customerservice.uk@danfoss.com
Fitting the Sensor
1. The Danfoss snap-on mounting is easy to install and requires no use of tools.
2. When the sensor is in place, the snap­on mechanism is activated and the sensor is mounted correctly.Tighten the coupling by turning the snap-on ring clockwise.
3. Set desired room temperature.
Removing the Sensor
1. The sensor is removed by turning the snap-on ring counter-clockwise.
2. Before remounting the snap-on mechanism must be activated manually by turning the snap­on ring counter­clockwise.
Setting the desired room temperatures
The desired room temperature is set by turning the head. The temperatures obtained are approximately:
Do not cover the thermostat
The thermostat opens and closes as determined by the temperature around it. Therefore the sensor must never be hidden behind thick curtains, furniture, etc. Alternatively a thermostat with remote sensor should be used.
Lockshield valve (type RLV-D) is only included in codes: 013G6545 & 013G6546.
Removal of protective cap
Balancing