Danfoss AT BTD Fact sheet

Fact sheet
Termix AT BTD
Tank solution for domestic hot water preparation with thermostatic control.
Application
The Termix AT BTD is a complete tank solution for DHW preparation with a pressure independent balancing and control valve. The AT BTD is available in two versions: with and without connection for domestic cold water tap. The substation is used instead of a conventional DHW unit with a plate heat exchanger; making it the perfect choice for areas where problems with corrosion-aggressive fresh water is known to occur.
District heating (DH)
On the primary side, the unit consists of a combined balancing and control valve for thermostatic DHW control and shut-o valves for ow and return lines.
Domestic hot water (DHW) The do­mestic hot water circuit consists of a hot water tank with coil. The hot wa­ter tank and coil are enameled and the tank contains a magnesium anode. A safety valve is installed in the cold wa­ter mains.
Options
The AT BTD is available in a version with a connection for cold water tap. This unit also comprises tting pieces for metering of the cold water mains and the cold water tap. Furthermore the unit has DHW shut-o valves for both DCW and DHW circuits. A mounting rail for in-wall mounting of the connections is oered as an ac­cessor y.
Construction
All pipes are made of stainless steel. The connections are made by nuts and gaskets. The Termix AT BTD is completed by a white steel cover in
modern design with door.
FEATURES AND BENEFITS
• Substation for single - family houses or apartments
• DHW regulation with a pressure independent balancing and control valve
• Ideal for areas with corrosion aggressive fresh water
• 100 or 150 ltr. tank
• Available with 4 or 5 connections; 5 connections for domestic cold water tap
• Suitable in cases of low district heating capacity
• Pipes made of stainless steel
www.danfoss.com
CIRCUIT DIAGRAM - EXAMPLE
100/4 + 150/4
DHW
DCW
DHF
DHR
Technical parameters:
Nominal pressure: PN 10* DH supply temperature: T
= 95° C
max
Weight incl. cover:
85-100 kg (incl. packing)
Cover: White-lacquered steel
Dimensions (mm):
H 1220 x W 540 x D 520 (type 100/4 + 100/5)
H1550 x W 540 x D 520 (type 150/4 + 150/5)
100/5 + 150/5
DHW
DCW
DWM
DHF
DHR
Connections:
The connections are situated underneath the hot water tank
Connections sizes:
DH + CWM + DCW + DHW: ¾“G (int. thread)
100/4 + 150/4 E Hot water tank with coil 1 Ball valve 4 Safety valve 20 Filling/drain valve 59 Di./Temp. Reg. w. ow lim.
100/5 + 150/5 E Hot water tank with coil 1 Ball valve 1A Ball valve, DVGW 2 Single check valve 4 Safety valve 20 Filling/drain valve 41A Fitting piece, cold water mains
Options:
• Fitting pieces for metering of the cold water mains and the cold water tap (type 100/5 + 150/5)
• Accessory - Mounting rail for in-wall mounting of connections
Module code number:
AT BTD 100/4: 144H1741 AT BTD 150/4: 144H1742 AT BTD 100/5: 144H1739 AT BTD 150/5: 144H1740 Mounting rail: 144H1752
DHW: Capacity examples, 10 °C / 50 °C
Substation type
AT BTD - 1 100
AT BTD - 2 150
* Output first hour = constant output + 60 % of tank volume
Tank volume
[ l ]
Coil supply / return
temperature
[ °C ]
80 / 40 486 546 22,6 70 / 30 245 305 11,4 60 / 30 172 232 8,0 80 / 40 486 576 22,6 70 / 30 245 335 11,4 60 / 30 172 262 8,0
DHW
constant output
[ l/h ]
DHW
output first hour*
[ l/h ]
Gemina Termix A/S · Member of the Danfoss Group · Navervej 15-17 · DK-7451 Sunds · Denmark Tel.: +45 9714 1444 · Fax: +45 9714 1159 · mail@termix.dk · www.heating.danfoss.com
© Danfoss | DHS-SRMT/ PL | 2017. 05
DHW
constant output
[ kW ]
VL.JV.Y2.02
Loading...