Danby ADR70B1C User Manual [en, es, fr]

USER’S MANUAL
FOR YOUR SAFETY: Read these instructions carefully before operating the unit. POUR VOTRE SÉCURITÉ: Lire attentivement ces instructions avant d’utiliser l’appareil. PARA SU SEGURIDAD: Lea y observe todas las reglas de seguridad y las instrucciones de operación antes
MODEL • MODÈLE • MODELO
• OWNER’S USE AND CARE GUIDE
• GUIDE D’UTILISATION ET SOINS DE PROPRIÈTAIRE
GUÍA DE UTILIZACIÓN Y CUIDADO PARA EL PROPIETARIO
PORTABLE DEHUMIDIFIER DESHUMIDIFICATEUR PORTATIF DESHUMIDIFICADOR PORTÁTIL
ENGLISH
FRANÇAIS
ESPAÑOL
ADR30B1G • ADR50B1G • ADR70B1G • ADR70B1C
PAGE 1
PAGE 13
PAGE 25
DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9
DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840
V1.21.11.13
TO OBTAIN WARRANTY SERVICE YOU MUST PROVIDE A VALID PROOF OF PURCHASE. PLEASE STAPLE YOUR RECEIPT TO THIS PAGE FOR FUTURE REFERENCE.
------------------------------------------------------------------------------------------------------------------­POUR OBTENIR LE SERVICE SUR GARANTIE VOUS DEVEZ FOURNIR UNE
PREUVE D’ACHAT VALIDE. VEUILLEZ AGRAFER VOTRE REÇU À CETTE PAGE POUR RÉFÉRENCE FUTURE.
------------------------------------------------------------------------------------------------------------------­PARA OBTENER SERVICIO DE GARANTÍA, DEBE PROVEER UN RECIBO
ORIGINAL. POR FAVOR ENGRAPE SU RECIBO A ÉSTA PÁGINA EN CASO QUE NECESITE HACER UN RECLAMO.
IMPORTANT - GROUNDING METHOD
This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed.
IMPORTANT - MÉTHODE POUR LA MISE À LA TERRE
Ce produit arrive d’origine avec un cordon d’alimentation équipé d’une prise à trois fi ches. Il doit être branché dans une prise avec une fi che de mise à la terre en conformité avec le Code National de l’Électricité et les codes et règles locales applicables. Si le prise murale n’a pas de mise à la de terre, il est de la responsabilité et l’obligation du client de changer la prise existante pour la rendre conforme aux Codes Nationaux de l’Électricité, aux codes et règles locaux applicables. La fi che de la mise à la terre ne doit pas, en aucune circonstance, être coupée ou retirée.
IMPORTANTE - MÉTODO DE CONEXIÓN A TIERRA
Este producto viene equipado con un cable eléctrico que tiene un enchufe de tres patas con conexión a tierra. Este debe colocarse en una toma de corriente con conexión a tierra de acuerdo con el Código nacional de electricidad y códigos y ordenanzas locales correspondientes. Si el circuito no cuenta con una toma de corriente con conexión a tierra, es responsabilidad y obligación del cliente sustituir la toma de corriente actual de acuerdo con el Código nacional de electricidad y códigos y ordenanzas locales correspondientes. Bajo ninguna circunstancia se debe cortar o eliminar la tercera pata de conexión a tierra.
CONTENTS
PORTABLE DEHUMIDIFIER
Owner’s Use and Care Guide ................................1-12
• Welcome
• Important Safety Information
• Installation Instructions
• Operation Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
DESHUMIDIFICATEUR PORTATIF
Guide d’utilisation et d’entretien du propriétaire...13-24
• Bienvenue
• Consignes de sécurité importantes
• Consignes d’installation
• Consignes d’utilisation
• Soins et entretien
• Dépannage
• Garantie
DESHUMIDIFICADOR PORTÁTIL
Guía de utilización y cuidado para el propietario..25-36
• Bienvenido
• Instrucciones de seguridad importantes
• Instrucciones de instalación
• Operación
• Cuidado y mantenimiento
• Diagnósticos de problemas
• Garantía
CAUTION:
Read and follow all safety rules and operating instructions before ¿ rst use of this product.
PRÉCAUTION:
Veuillez lire attentivement les consignes de sécurité et les instructions d’utilisation avant l’utilisation initiale de ce produit.
PRECAUCIÓN:
Lea y observe todas las relgas de seguridad y las instrucciones de operación antes de usar este producto por la primera vez.
Model • Modèle • Modelo
ADR30B1G • ADR50B1G • ADR70B1G • ADR70B1C
WELCOME
Welcome to the Danby family. We’re proud of our quality products, and we believe in dependable service, like you will ¿ nd in this Owner’s Use and Care Guide, and like you will receive from our friendly customer service department. Best of all, you will experience these values each and every time you use your Danby appliance. That’s important, because your new appliance will be a part of your family for a long time.
Note the information below; you will need this information to obtain service under warranty. To receive service, you must provide the original receipt.
Model No:
Serial No:
Date Purchased:
NEED HELP?
Before you call for service, here are a few things you can do to help us serve you better:
Read this Owner’s Use and Care Guide:
It contains instructions to help you use and maintain your appliance properly.
If you received a damaged appliance:
Immediately contact the retailer (or builder) that sold you the appliance.
Save time and money:
Check the Troubleshooting section at the end of the guide before calling. This section helps you solve common problems that may occur.
If you do need service, you can relax, knowing help is only a phone call away.
Tel: 1-800-26-
(1-800-263-2629)
WARNING
Improper connection of the grounding plug can result in risk of Fire, Electric Shock and/or injury to Persons associated with the appliance. Check with a qualifi ed service representative if in doubt that the appliance is properly grounded.
1
IMPORTANT SAFETY INFORMATION
READ AND FOLLOW ALL SAFETY INSTRUCTIONS FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
NOTE
The WARNING instructions issued in this manual are not meant to cover all possible conditions and situations that may occur. Person(s) installing, maintaining, or operating the appliance must exercise caution and care. Failure to install, maintain, and/or operate the equipment according to the manufacturer’s instructions may result in conditions which can produce personal injury and damage to your unit and/or property damage. Contact your dealer, service agent, and/or the manufacturer about any problems or conditions you do not fully understand. For Danby Customer Service call (1-800-
263-2629).
ELECTRICAL REQUIREMENTS
To reduce the risk of ¿ re, electric shock, or personal injury, all wiring and grounding must conform with the latest edition of Local and National Electrical codes.
• It is the customer’s responsibility to have the wiring and fuses checked by a quali¿ ed electrician to make sure adequate electrical power is available.
• This appliance is designed to operate on an effectively grounded, separately branched, polarized, 3-wire, 120 Volt 60 Hertz (alternating current) circuit protected by a 15 ampere fuse, equivalent fuse or circuit breaker.The three-prong grounding plug on the power cord should be plugged directly into the aforementioned receptacle rated 110/120 V.A.C.
• Do not connect the dehumidi¿ er to a multiple socket outlet that is also being used for other electrical appliances.
FOR YOUR SAFETY: To reduce the risk of fi re or explosion, do not store or use gasoline or other fl ammable va- pors or liquids in the vicinity of this or any other appliance.
GROUNDING INSTRUCTIONS
Improper connection of the equipment-grounding conductor can result in a risk of electrical shock. Check with a quali¿ ed electrician or serviceperson if you are in doubt as to whether your appliance outlets are properly grounded.
• This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical current. This appliance is equipped with a cord that has an equipment-grounding conductor and 3 prong grounding plug. The plug must be connected into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
• Do not modify the plug provided with this appliance. If it will not ¿ t the outlet, have a proper outlet installed by a quali¿ ed electrician.
• If the household electrical supply does not meet the above speci¿ cations, or if you are not sure your home has an effective ground, have a quali¿ ed electrician or your local electrical utility company check it and correct any problems.
SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INFORMATION
READ AND FOLLOW ALL SAFETY INSTRUCTIONS FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
SAFETY PRECAUTIONS
When using this dehumidifi er, always follow basic safety precautions, including the following:
• Use this appliance only for its intended purpose as described in this Owner’s Manual.
• This dehumidi¿ er must be properly installed and grounded as described in this manual before it is used.
• Never operate this dehumidi¿ er in an area that is likely to accumulate standing water. If this condition develops, for your safety disconnect the power supply before stepping into the water.
• Never unplug your dehumidi¿ er by pulling on the power chord. Always grip the plug ¿ rmly and pull straight out from the receptacle.
• Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
• If the receptacle does not match the plug, the receptacle must be changed out by a quali¿ ed electrician.
• Turn the dehumidi¿ er OFF and unplug it before cleaning.
• For your safety, do not store or use combustible materials, gasoline or other À ammable vapors or liquids in the vicinity of this or any other appliance.
• All dehumidi¿ ers contain refrigerants, which under federal law must be removed prior to product disposal. If you are disposing of a product with refrigerants, check with the company handling disposal about what to do. Check for local regulatory compliance regarding the approved and safe disposal of this appliance.
• Do not use outdoors.
• This dehumidi¿ er is intended for indoor residential applications only. This dehumidi¿ er should not be used for commercial or industrial applications.
SAVE THESE INSTRUCTIONS
3
INSTALLATION INSTRUCTIONS
LOCATION
• Select a suitable location, making sure you have easy access to an electrical outlet (avoid the use of extension cords). If it is absolutely necessary to use an extension cord, use an approved “air conditioner” heavy duty extension cord ONLY (available at most local hardware stores).
• Make sure there are no obstructions restricting airÀ ow through the front air intake grill. Maintain a minimum clearance of at least 20 cm (8”) between adjacent walls and the back of the unit, to allow for proper air circulation and maximum ef¿ ciency. To achieve maximum operating ef¿ ciency from your dehumidi¿ er, the recommended (room ambient) operating temperatures should be between 5°C (41°F) - 35°C (95°F).
• It is important to remember the ef¿ ciency of a dehumidi¿ er will be affected/inÀ uenced by the rate at which new humid air (moisture) is allowed to in¿ ltrate the same space/area. To maintain ef¿ ciency, the dehumidi¿ er must be operated in an enclosed area. Keep all doors and windows closed.
• Do not use this unit outdoors. This dehumidifer is intended for indoor residential applications only. This dehumidi¿ er should not be used for commercial or industrial applications.
• Place the dehumidi¿ er on a smooth, level À oor strong enough to support the unit with a full bucket of water.
• Place the unit where it has access to an electrical outlet.
• This unit has 4 castors which can move freely. Do not force castors to move over carpet, and refrain from moving the unit with water in the bucket (the unit may tip over and spill water). Protect wood À oors from possible spillage or scratches when moving unit.
• Remove accessory bag from bucket and store it in a safe place.
FEATURES
• Soft Touch (Electronic) Control Key Pads
• Auto-Sensing Humidity Control
• Adjustable Humidity Settings (35% - 85%)
• 2 Fan Speed Settings (Turbo/ Normal)
• Delay Start Protection (Compressor)
• Auto-Defrost (De-Icer)
• Full Bucket Indicator Light
• Easy Roll Castors (4)
• Front Mounted Water Tank (Removable)
• Direct Drain Option (Hose not included)
• Quiet Operation
• Removable Air Filter
4
OPERATION INSTRUCTIONS
CONTROL PANEL INSTRUCTIONS
(2) Reset filter button
(1) Continuous mode
Continuous mode indicator
CONTROLS
NOTE: The control panel of the unit you purchased may be slightly different
depending on the model number.
(7)Display Check filter light
Auto on indicator light
Bucket full
(6)
Timer button
(5)
Up and
down
buttons
Auto off indicator light
Turbo fan speed indicator
(3) Fan button Normal fan speed
indicator
(4) Power button
Auto defrost
When you push the button to change operation modes, the unit will make a beeping sound to indicate that it is changing modes.
1) CONTINUE BUTTON Press to activate the continuous dehumidifying operation. Refer to page 7.
2) FILTER BUTTON This product has a check ¿ lter feature that is a reminder to clean the air ¿ lter for more ef¿ cient operation. The check ¿ lter light will illuminate after 250 hours of operation. To reset this function after cleaning the ¿ lter, press the reset ¿ lter button and the light will go off.
3) FAN BUTTON Controls the fan speed. Press to select either High (Turbo) or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control back to Normal.
4) POWER BUTTON Press to turn the dehumidi¿ er on or off.
5) ( + / - ) BUTTONS
The humidity level can be set within a range of 35% RH (Relative Humidity) to 85% RH in 5% increments using these buttons.
• For drier air, press the (-) button and set to a lower percentage value (%)
• For more damp air, press the (+) button and set a higher percentage value (%)
6) TIMER BUTTON Press to initiate the auto-start and auto-stop feature. Set a start or stop time from 0.0 to 24 hours using the (+) and (-) keys. Refer to page 6.
7) DISPLAY Shows the actual (± 5% accuracy) room humidity level in a range of 30% RH to 90% RH. Otherwise, displays selection when programming humidity or timer.
5
OPERATION INSTRUCTIONS
ERROR CODES
AS - Humidity sensor error -- Unplug the unit and plug it back in. If error repeats, call for service. ES - Temperature sensor error -- Unplug the unit and plug it back in. If error repeats, call for service. P2 - Bucket is full or the bucket is not in correct position -- Empty the bucket and/or adjust it to the proper position. EC - Please ensure that the room ambient temperature matches the recommended operating temperature for the unit,
5°C (41°F) - 35°C (95°F). If the temperature is within this range, call for service.
INDICATOR LIGHT FUNCTIONS
IMPORTANT NOTE: Depending on the humidity conditions of the surrounding environment, the dehumidi¿ er may not start
automatically when the “on/off” button is pressed (see dehumidifying mode instructions on page 7 for details).
MEMORY SETTING:
Each time the unit is disconnected/re-connected and/or in the event of a power failure, the electronic circuit board automatically defaults to the last program setting that was used. After the unit has stopped, it may take several minutes before operating conditions resume.
AUTO-RESTART:
If the unit shuts off unexpectedly due to a power outage, it will restart with the previous function settings automatically when the power resumes.
BUCKET FULL INDICATOR LIGHT: When the bucket is full and/or incorrectly positioned inside the cabinet, the bucket full light will turn on and remain on until the bucket is emptied and/or correctly re-positioned. This condition will result in the immediate shut down of the dehumidifying system (both compressor and fan motor operation are terminated). This is a safety feature. When the bucket is emptied and/or correctly re-positioned, the dehumidi¿ er will resume operation automatically. NOTE: It may take several minutes before operating conditions resume.
AUTO-DEFROST:
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
TIMER FUNCTIONS
Follow these steps to program the Auto-On or Auto-Off feature using the control panel: Auto-Off:
1) When the unit is on, and the TIMER button is pressed, the Timer Off indicator light illuminates to indicate that the Auto- Off program is initiated.
2) Press or hold the UP or DOWN button to change the ‘Auto’ time by 0.5 hour increments, up to 10 hours (then at 1 hour increments up to 24 hours). The unit control will count down the time remaining until start.
3) Within 5 seconds of setting Auto Off time, press the TIMER button again to complete the Auto-Off program. Auto-On:
4) When the unit is off, and the TIMER button is pressed, the Auto-On program is initiated. Set the Auto-On time as in step 2 above. Within 5 seconds of setting Auto-On time, press the TIMER button again to complete the Auto On program. NOTE: When the Auto On & Auto Off times are set, within the same program sequence, TIMER ON OFF indicator lights illuminate indicating that both ON and OFF times are now programmed. NOTE: Turning the unit ON or OFF at any time, changing the On/Off timer setting to 0.0, and a P2 error code will cancel the Auto-On/Off function.
6
OPERATION INSTRUCTIONS
W ATER T ANK OPERATION
The water tank holds accumulated condensed water, and us­ing a safety switch, controls both the water level and opera­tion of the dehumidi¿ cation process - i.e. when the water tank is full and/or accidentally displaced inside the cabinet, the À oat switch actuator (inside the tank) breaks contact with the safety switch. This condition results in the immediate shut down of the compressor and fan motor system, preventing moisture from being condensed.
NOTE: On some models, the fan will continue to run for approximately 2-3 minutes after the unit has stopped and the bucket has been removed. As a result, water may drip from the tray onto the base of the unit, and then onto the fl oor. Please ensure that you protect your wood and carpet fl oors from such leakage.
IMPORTANT:
Never tamper with or attempt to defeat the water level (safety) fl oat switch system. Proper installation of the water tank is crucial to maintaining reliable dehumidifi er operation.
DEHUMIDIFYING
DEHUMIDIFYING is a means of removing moisture from the air. A dehumidi¿ er will help to protect your home and valued
possessions from damage (swelling) caused by moisture in the air. Essentially a dehumidi¿ er removes moisture from air as moist air passes over a dehumidifying (evaporator) coil. Moisture is condensed on the evaporator coil, drained, and collected inside an internal (removable) water tank located at the front of the unit. The exhausted air being returned into the room environment is elevated several degrees causing the surrounding air temperature to increase (slightly). This process also contributes to lowering the relative humidity of the surrounding air.
DEHUMIDIFYING MODE INSTRUCTIONS
When the unit is ¿ rst connected to the electrical outlet, the (green) power light will not light up until the “on/off” button is pressed. When the “on/off” button is pressed, the power light turns on and the dehumidi¿ er automatically defaults to:
Display: Current Ambient Room Humidity (RH%) Humidity Setting: 60% RH Fan Speed: High
IMPORTANT NOTE: Depending on humidity conditions of the surrounding environment, the dehumidi¿ er may not start
automatically under the default setting (this is an indication that the humidity level of the surrounding environment is lower than the “default” setting of 60% RH). Therefore, it may be necessary to scroll through each of the different dehumidi¿ er settings 35% - 80% until the “humidistat” (sensor) recognizes conditions that will allow the unit to operate.
DEHUMIDIFYING MODE SELECTION:
1) The unit enters dehumidify mode when the ON/OFF button is pressed. 2a) Press the
OR
2b) Press the CONTINUOUS button. When CONTINUOUS mode is selected, the humidistat (sensor) will be by-passed and the compressor will operate non-stop regardless of humidity conditions.
FAN SPEED SELECTION:
3) You can choose a fan speed (normal/turbo) using the keypad. The speed you select is identi¿ ed by the (illuminated) indicator light located directly above the selection made.
+ / - buttons to select a desired RH operating value (35% -85%).
7
OPERATION INSTRUCTIONS
AIR FILTER
Your dehumidifer features a removable air ¿ lter, located at the front of the unit (behind the air intake grill) directly above the water tank compartment. The air ¿ lter plays an important role in helping to reduce dust/dirt particles from the surrounding environment. A blocked/clogged air ¿ lter reduces air intake, negatively impacting operating ef¿ ciency. To maintain maximum operating ef¿ ciency:
• The ¿ lter must be checked and cleaned regularly (every 2 weeks) or when the check ¿ lter light illuminates.
• More frequent cleaning may be required depending upon indoor air quality.
IMPORTANT: Never operate the unit without the air ¿ lter in place.
AIR FILTER REMOVAL:
1) There are two options depending on your model. Option A: Grasp the ¿ lter handle, and pull the ¿ lter out. The ¿ lter will slide out easily (see Fig. 2). Option B: Remove the bucket and pull the ¿ lter downwards (see Fig. 3 on page 10).
2) Clean the ¿ lter thoroughly using a vacuum cleaner or wash using lukewarm water and mild detergent. Dry thoroughly before re-installing.
3) To re-install the air ¿ lter, slide the ¿ lter back inside the tracks and push inward.
4) Press reset ¿ lter button.
Fig.2
Front:
1. Control Panel
2. Air Intake Grille
3. Air Outlet Grille
4. Air Filter (behind the grille)
5. Water Bucket
6. Handle (both sides)
Back:
1. Drain Hose Outlet
2. Castor
3. Power Cord and Plug
4. Band (Used only when storing the unit.)
NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same
8
OPERATION INSTRUCTIONS
REMOVING COLLECTED WATER
A1. Pull the bucket out a little
A2. Hold both sides of the bucket with
even strength, and pull it out from the unit. Pour the water out.
B1.
Drain hose
Adaptor A
There are two ways to remove collected water.
A. Use the bucket
When the unit is off and the bucket is full, the unit will beep 8 times, the Bucket Full indicator light will À ash, and the digital display shows P2. When the unit is on and the bucket is full, the compressor turns off and the fan turns off after drying the water off the condenser for 30 seconds. The unit will then beep 8 times and the Bucket Full indicator light will À ash, and the digital display shows P2.
To empty the full bucket, slowly pull out the bucket. Grip the left and right handles securely, and carefully pull it straight out so water does not spill. Do not put the tank on the À oor because the bottom of the bucket is uneven. Otherwise the bucket will fall and cause the water to spill. Discard the water and return the bucket to the unit. The bucket must be in place and properly positioned for the dehumidi¿ er to operate. The machine will re-start when the bucket is restored in its correct position.
NOTE:
When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product. Be sure to push the bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in securely may cause the unit not to operate. When you remove the bucket, if there is some water inside the unit you must dry it.
B2.
Plastic cover
Drain hose subassembly
B3.
Connector
Drain hose
B4.
Water hose
B. Continuous draining
Water can be automatically emptied into a À oor drain by attaching the unit to a ID 5/16” water hose with a ID:M=1 female threaded end (not included). Install the drain hose onto the adaptor A (see B1). The adaptor is found in the accessory bag located in the bucket. Remove the plastic cover from the back drain outlet of the unit and set it aside. Remove the bucket, then insert the drain hose through the drain outlet of the unit and securely press it into the connector on the front of the unit. (See B2.)
Tighten the adaptor A and the unit by using two screws (found in the accessory bag located in the bucket upon purchase). Install the female threaded end of the water hose into the adaptor A. (See B4), then lead the water hose to the À oor drain or a suitable drainage facility. Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will stop the water from À owing. Place the end of the hose into the drain and make sure the end of the hose is level or declining to let the water À ow smoothly. Place the bucket back in the unit and make sure that it is located correctly. Select the desired humidity setting and fan speed on the unit for continuous draining to start.
Accessories (for continuous drain):
Drain hose (1 pc) Adaptor A (1 pc) Screw (2 pc)
Female thread end