Daktronics SETTING LIMIT SWITCHES User Manual

SETTING LIMIT SWITCHES
The limit switches are typical for Daktronics Pro Series and S Series control systems. Access the limit switches by opening the electrical cover on the offstage end of the hoist.
The limit switch adjusters are two 3/8" Hex Head Nuts located on the back upper wall of the enclosure. The nuts are partially hidden by the electrical wiring.
Use a nut driver to adjust the limits:
Lower Limit switch (left) – rotate the
adjusters counter-clockwise to set limits to a lower position
Higher Limit switch (located toward the
hoist center) – rotate the adjuster clockwise to set limits to a higher position
Do not force the limit switch adjusters or damage may occur to the limit switch assembly inside the hoist. The upper and lower limit switches are preset at the factory to approximate settings based on project information.
Copyright © 2011 Daktronics, Inc. Page 1 of 1 DD1995254 4 April 2011