3P214218-1 M07B111

Removing and installing front panel

Opening service lid of indoor unit

Remote Control PC-Board Set <KRP980B1>
Installation Manual

Safety Precautions

Read these Safety Precautions carefully to ensure correct installation.
This manual classifies precautions into WARNING and CAUTION.
WARNING :
CAUTION : Failure to follow CAUTION may result in serious
Be sure to follow all the precautions below ; they are all important for ensuring safety.
• Installation should be left to the dealer or another qualified professional.
Improper installation by yourself may cause malfunction, electrical shock, or fire.
Install the set according to the instructions given in this manual.
Incomplete or improper installation may cause malfunction, electrical shock, or fire.
Be sure to use the standard attachments or the genuine parts.
Use of other parts may cause malfunction, electrical shock, or fire.
• Disconnect power to the connected equipment before starting installation.
Failure to do so may cause malfunction, electrical shock, or fire.
• An earth leakage circuit breaker should be installed.
If the breaker is not installed, electrical shock may occur.
Do not install the set in a location where there is danger of exposure to inflammable gas.
Gas accumulated around the unit at the worst may cause fire.
• To prevent damage due to electrostatic discharge, touch your hand to a nearby metal object (doorknob, aluminum sash, etc.) to discharge static electricity from your body before touching this kit.
Static electricity can damage this kit.
• Lay this cable separately from other power cables to avoid external electrical noises.
After installation is complete, test the operation of the PCB set to check for problems, and explain how to use the set to the end-user.
Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury.
injury or property damage, and in certain circumstances, may result in a grave consequence.
WARNING
CAUTION

Mounting Procedure

Outline/Features

This set is an interface that connects a wired remote controller to a room air conditioner.
Starting and stopping the air conditioner and making mode and temperature
• settings in the air conditioner through the wired remote controller (within a
range of 18˚C to 32˚C while in cooling mode, 14˚C to 30˚C while in heating mode, but no temperature settings while in ventilation mode).
Monitoring the operating conditions, occurrence of errors, and contents of
• errors of the air conditioner through the wired remote controller.
Restoring the operating condition of the air conditioner to the previous
• condition at the time of power recovery in case of power failure.
The set does not support the following functions.
Group control (i.e., the control a number of indoor units through a single
• remote controller)
Monitoring of the following items:
• Indoor temperature and operating conditions of thermo, compressor, indoor
fan, electric heater, and humidifier
Control of the following items:
• Forced thermo OFF, filter sign display and reset, and air-conditioner charge
management
Energy-saving reference, low-noise reference, and demand reference

Components

Check that the set is provided with the following components.
Component Component
Main component
Quantity Quantity
Installation Manual
11
• Removal method
1)Place your fingers in the indentations on the main unit (one each on the left and right sides), and open the panel until it stops.
2)Continue to open the front panel further while sliding the panel to the right and pulling it toward you in order to disengage the rotating shaft on the left side. To disengage the rotating shaft on the right side, slide the panel to the left while pulling it toward you.
Indentations on the main unit
• Installation method
Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the center of the lower surface of the panel firmly to engage the tabs.
Rotating shaft
Push the rotating shaft of the front panel into the groove.

Removing and installing front grille

• Removal method
1)Remove front panel to remove the air filter.
2)Remove the screws (2) from the front grille.
3)In front of the mark of the front grille, there are 3 upper hooks. Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand.
Upper hook
The service lid is of removable type.
• Opening method
1)Remove the single screw of the service lid.
2)Pull out the service lid frontward.
mark area (3 locations)
Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers of your other hand. (3 locations)
Service lid
Screw
Upper hook
Push down.
Upper hook
Mounting Position Wiring
Flap (in control of wind directions upward and downward)
Mounting position of the set
Electrical component box
Electrical component box
Mounting position of the set
Option BRC944A2B
PCB of indoor unit
This set
Inside indoor unit
S602 S601
S21
S403
When there is no work space because
<
the unit is close to ceiling
>
CAUTION
Be sure to wear protection gloves.
Place both hands under the center of the front grille, and while pushing up, pull it toward you.
2) Pull toward you.
1) Push up.
• Installation method
1)Install the front grille and firmly engage the upper hooks (3 locations).
2)Install 2screws of the front grille.
3)Install the air filter and then mount the front panel.

Removing electrical component cover

Connecting electrical component (this set)

* Refer to the surface page for the removal of each part in detail.
*1 Remove the front panel.
*2 Remove the front grille.
*3 Remove the service lid of the indoor unit.
4 Remove the cover of the electrical component cover.
On completion of the connection of the electrical component (this set), mount the removed parts to the original positions.
Electrical component box
If there is a workspace on the right-hand side of the indoor unit, the installation work can be conducted without removing the electrical component box.
Mounting screw of electrical component box.
WARNING
• Be sure to turn OFF the power at the time of installation work.
Do not touch any electric parts with the power turned ON. Otherwise, an electric shock may be received.front panel.
Remove the tabs.
Electric component cover
Tab
Prepare the electrical component (this set).
1.
(See Fig. 1)
1) Remove the electrical component cover
of the set.
2) Insert the connection cord into the S21
connector (white) of the set.
3) Route each connection cord through the
cut-out of the set and mount the electrical
component cover to the original position.
4) Insert the connector of the set into the
S403 in the indoor unit electrical
component connector. Then route the
connection cord to the cut-out (cut-out A)
in the indoor unit electrical component.
2.
Mount the electrical component cover to
the original position. (See Fig. 2)
3.
Mount the set. (See Fig. 2)
1) Mount the set to the electrical component
box of the indoor unit.
2) Route the connection cord as shown in
Fig. 2 (Routing connection cord).
Fig. 1
Remove the electrical component cover.
Disengage the tab.
S21
Route each connection cord through the cut-out.
Preparing the electrical component (this set).
Electrical component
Insert the cord into the S403.
Cut-outs
Electric component cover
*1 Route the connection cord through the cut-out (cut-out A).
*1 Connection cord cut-out
Cut-out A
S403 connection cut-out
Cut-out B
S403 connection cut-out
Cut-out C
Connection cord cut-out

Removing electrical component box

If there is a workspace on the right-hand side of the indoor unit, the installation work can be conducted without removing the electrical component box.
1. Remove the flap (in control of wind directions upward and downward).
2. Disconnect the communication wiring (see Fig. 1).
3. Disconnect the S200 connector (see Fig. 2).
4. Disconnect the heat changer from the thermistor (see Fig. 3).
5. Remove the mounting screw of the electrical component box, and remove the electrical component box (see Fig. 1).
Positions of communication wiring and mounting
screw of electrical component box
Position of thermistor
Fig. 3
Thermistor
Fig. 1
On completion of the connection of the electrical component (this set), mount the removed parts to the original positions.
Fig. 2
Position of each
connector
S200
Fig. 2
Install the electrical component cover in its original position.
Electric component cover
Electrical component
Push the electrical component until it snaps into engagement with the tab.
Installing electrical component
Install the electrical component.
Place the connection cord to come in contact with the protruding part.
Connection cord
Protruding part
Fit in.
Routing connection cord
S403 connection cord
Make sure that the mounting bracket of the thermistor will not fall off.
Flap
Communication wiring
Mounting screw of electrical component box
Connection cord
Tab
3P214218-1