DIGITAL THERMOSTAT 230 V |
|
|
|
|
|
EKWCTRDI1V3 |
1 |
2 |
|
3 |
|
|
|
|
|||
|
4a |
3,5 mm |
|
4b |
60 mm |
|
|
|
|||
|
|
|
|
||
1x |
|
Protective cover |
|
||
|
|
|
|
|
|
|
5 |
6 |
|
7 |
|
The EKWCTRDI1V3 with display is intended for regulating the room |
|
|
|
|
|
temperature by setting the desired target temperature for the activation of |
|
|
|
|
|
actuators in heating/cooling operation. Every other use is considered not |
|
|
|
|
|
intended; the manufacturer cannot be held liable for unintended use. |
|
|
|
|
|
¾¾ The electrical installation must be performed according to the |
5 |
> L/L1 |
|
|
|
current national VDE regulations as well as according to the |
|
Cleaning |
|
||
regulations of your local electric power utility company, by an |
|
> N/L2 |
|
||
authorised and trained electrician, and in a de-energised state. |
|
Only use a dry and solvent-free soft |
|||
¾¾ Only an authorised electrician may open the device. It may only |
|
|
cloth for cleaning. |
|
|
be opened in de-energized state. |
|
|
Dismantling |
|
|
¾¾ Only use the device if it is in perfect state. |
|
|
1. |
Switch off the voltage supply. |
|
¾¾ Ensure that children do not play with this device. Children must |
|
|
2. |
Remove the wiring. |
|
be monitored if necessary. |
|
|
3. |
Take off the thermostat and dispose |
|
|
|
|
|
of it properly. |
|
1a 2 |
1 b2 |
1c 2 |
<![if ! IE]> <![endif]>L/L1 N/L2 |
<![if ! IE]> <![endif]>=> |
<![if ! IE]> <![endif]>CO N‘/L2‘ |
± 30 cm
± 150 cm
|
|
|
|
|
|
|
|
|
|
|
|
1. |
Display with function indicators |
||
|
|
|
|||||
|
|
2. |
Dial |
|
|||
|
|
|
|
|
• Rotate: |
Set target temperature/ |
|
|
|
|
|
|
|
operate menu |
|
|
|
|
|
|
• Press: |
Activate menu level/ |
|
1 |
|||||||
|
functions |
2 |
Press the dial to activate menus or features. Rotate the dial to switch between menus and features and press again to open. Adjust settings and press to confirm. If no further operation is performed, the display will return to its original state after max. 30 seconds.
1
Lifestyle functions |
Minimum temperature |
Settings |
Maximum temperature |
Heating |
Confirm settings |
Operating lock |
Temperature correction |
Switching off |
Back |
Automatic operation |
Service |
Day operation |
Cooling |
Night operation |
Display illumination |
Target/actual temperature |
Loading factory settings |
|
|
|
https://qr.daikin.eu?N=EKWCTRDI1V3 |
|
|
|
|
Technical data |
|
Operating voltage: |
230 V ±10 %, 50 Hz |
Fuse 230 V: |
T1AH |
Switch. element 230 V: |
Relay |
Switching power: |
1 A resistive load |
Rated current w/o valve drives: |
230 V: ≤2 mA |
Max. current draw allowed with |
|
connect. valve drives 230V: |
1 A |
Temperature setting range: |
5 - 30 °C |
Connection terminals: |
0.22 mm² to 1.5 mm² |
Reduction difference: |
adjustable |
Temperature measurement: |
0 - 40 °C |
Ambient temperature: |
0 - 50 °C |
Storage temperature range: |
-20 to +70 °C |
Admissible ambient humidity: |
80%, not condensing |
Temp. for ball pressure test: |
Terminals: 100 °C |
|
Plastic enclosure: 75 °C |
CE conformity according to: |
EN 60730 |
Protection class 230 V: |
II |
Protection degree: |
IP 20 |
Pollution degree: |
2 |
Rated impulse voltage: |
1500 V |
Type action: |
Type 1 / Type 1.C |
Weight: |
105 g |
Dimensions (W x H x D): |
86 x 86 x 31 mm |
Valve protection function: |
Once every 14 days for 10 minutes |
|
after the last triggering. |
Antifreeze function: |
From +5 °C in heating mode. Inactive |
|
in cooling mode. |
This symbol means that electrical and electronic products may NOT be mixed with unsorted household waste. Units must be treated at a specialized treatment facility for reuse, recycling and recovery.