Daikin EKHTS200A, EKHTS260A, EKHTSU260AA, EKHTSP200AA, EKUHWHTA Installation Manual

...
INSTALLATION MANUAL
EKHTS200A EKHTS260A
EKHTSP200AA EKHTSP260AA
EKHTSU200AA EKHTSU260AA EKUHWHTA
Domestic hot water tank for air to
water heat pump system
2
4
1
3
2x 2x 5x 1x 1x 1x
+
+
+
+
++
13 6 75
2
4
1x
+
+
340 mm
11
10
12
12
13
2
1
5 4
6
8
3 9
1
2
7
772
902
1032
H
120
Ø60
1156
778
653
694
443
600
300
5
BC
>250
>250
A
>600
30
D
>30
2x
8
9
6
+
+
+
+
+
+
1
2
1
2
5
9
3
5
9
3
76
10
10
4104
(
*KHBRD
)
2
1
3
4
EKHTS200+260A + EKHTSP200+260AA
Domestic hot water tank for air to water heat pump system
4PW53247-1B
Installation manual
1
C
ONTENTS
P
age
Introduction........................................................................................ 1
General information ...................................................................................1
Scope of this manual .................................................................................1
Model identification ....................................................................................1
Accessories .......................................................................................1
Accessories supplied with the domestic hot water tank............................. 1
Optional equipment.................................................................................... 1
Overview of the unit........................................................................................... 2
Main components....................................................................................... 2
Outlook diagram......................................................................................... 2
Installation of the EKHTS domestic hot water tank ...........................3
Installation guidelines................................................................................. 3
Installing and commissioning the domestic hot water tank........................3
Maintenance......................................................................................6
Descaling ...................................................................................................7
Draining...................................................................................................... 7
Troubleshooting .................................................................................7
General guidelines.....................................................................................7
General symptoms..................................................................................... 7
Disposal requirements....................................................................... 7
Technical specifications .....................................................................8
Domestic hot water tank specifications...................................................... 8
The English text is the original instruction. Other languages are translations of the original instructions.
I
NTRODUCTION
General information
Thank you for purchasing this domestic hot water tank. The EKHTS domestic hot water tank can only be connected to the
EKHBRD indoor unit. The domestic hot water tank is available in two sizes: approximately 200 and 260 litre. All models can be mounted on top of the indoor unit. For installation of the domestic hot water tank on the floor next to the indoor unit, the dedicated EKFMAHTA connection kit is required.
Scope of this manual
This installation manual describes the procedures for unpacking, installing and connecting the domestic hot water tank.
Model identification
A
CCESSORIES
Accessories supplied with the domestic hot water tank
See figure 1
Optional equipment
EKFMAHTA Connection kit for installation of the domestic hot water tank on the
floor next to the indoor unit. Refer to the installation manual of the kit for more details.
EKHTS200A EKHTSP200AA EKHTS260A EKHTSP260AA
Domestic hot water tank
for air to water heat pump system
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION.
THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT TEMPERATURES RANGING 5°C~35°C.
NOTE
Especially for the United Kingdom
For installation of an EKHTSU domestic hot water tank, refer to the part of EKHTSU in this manual.
EK HTS P 200 A
Series
Identification of type
P = Special version with service opening (125 mm) Standard version when no letter is mentioned
Hot water Tank Stainless steel
European Kit
1
Flexible hose of heat exchanger coil
2
Hot/cold water flexible hose
3
Clamp
4
Installation manual
5
Unpacking instruction sheet
6
3-way valve assembly (body + motor + clamps + pipe + screws)
7
Knockout hole assembly (grommet + clamps + screws)
Installation manual
2
EKHTS200+260A + EKHTSP200+260AA
Domestic hot water tank for air to water heat pump system
4PW53247-1B
O
VERVIEW OF THE UNIT
Main components
Safety devices
Thermal protector — The EKHBRD indoor unit is equipped with a thermal protector. The thermal protector is activated when the temperature becomes too high. When activated, the protector has to be reset on the indoor unit by pressing the red button (for access, remove the decoration panels like indicated in the manual of the indoor unit).
Pressure relief valve — A pressure relief valve (field supply) in accordance with relevant local and national regulations, and with an opening pressure of maximum 10 bar must be connected to the pressure relief valve connection.
If a discharge pipe is connected to the pressure relief device it must be installed in a continuously downward direction and in a frost-free environment. It must be left open to the atmosphere.
Outlook diagram
Outlook diagram, see figure 2.
The total system (indoor unit and outdoor unit) is designed for combination with a Daikin domestic hot water tank. In case another tank is being used in combination with the Daikin indoor unit, Daikin cannot guarantee neither good operation nor reliability of the system. For those reasons Daikin cannot give warranty of the system in such case.
A
Hot water out connection (G 3/4" Female)
B
T-piece (field supply)
C
Pressure relief valve connection
D
Pressure relief valve (field supply)
E
Recirculation connection (G 1/2" Male)
F
Thermistor socket
G
Flow inlet connection from the main EKHBRD indoor unit at the bottom of the tank (quick coupling)
H
Heat exchanger coil
J
Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank (quick coupling)
K
Cold water in connection (G 3/4" Female)
L
Thermistor
A
H
K
G
J
F
E
M
Q
P
G
C D
J
L
N
B
E A
K
Q
M
Anode
N
Service opening (Ø125 mm) (only for EKHTSP models)
P
Casing
Q
Knockout holes for water piping
The domestic hot water tank relief valve connections may not be used for other purpose.
This domestic hot water tank can only be used with an EKHBRD indoor unit.
Switch off the power supply before opening the decoration panels of the indoor unit.
1
Hot water out connection (G 3/4" Female)
2
Cold water in connection (G 3/4" Female)
3
Hot water out connection at the bottom of the tank (quick coupling)
4
Cold water in connection at the bottom of the tank (quick coupling)
5
Recirculation connection (G 1/2" Male)
6
Flow inlet connection from the main EKHBRD indoor unit (quick coupling)
7
Return outlet connection to the main EKHBRD indoor unit (quick coupling)
8
3-way valve
9
Flow inlet connection from the main EKHBRD indoor unit at the bottom of the tank (quick coupling)
10
Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank (quick coupling)
11
Service opening (Ø125 mm) (only for EKHTSP models)
12
Knockout holes for water piping
13
Levelling feet (EKHBRD unit only)
Domestic hot water tank model H
EKHTS200A, EKHTSP200AA
2010 mm
EKHTS260A, EKHTSP260AA
2285 mm
Loading...