Domestic hot water tank specifications ..................................... 14
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
PLEASE LEAVE THIS MANUAL WITH THE EKHWSU
DOMESTIC HOT WATER TANK AFTER INSTALLATION.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.
THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED
FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT
TEMPERATURES RANGING 5°C~30°C.
INTRODUCTION
General information
Thank you for purchasing this domestic hot water tank.
The domestic hot water tank must be installed by a licensed
technician and be installed in compliance with instructions as of
subject in this manual, all current legislation, codes of practice and
regulations governing the installation of unvented hot water cylinders
in force at the date of installation.
This installation is subject to building regulation approval, notify
Local Authority of intention to install.
The EKHTS domestic hot water tank can be connected to EKHBRD,
EKHVMRD, EKHVMYD, EKHVH and EKHVX indoor units. The
domestic hot water tank is available in two sizes: approximately 200
and 260 litre. All models can be mounted on top of the indoor unit.
For installation of the domestic hot water tank on the floor next to the
indoor unit, the dedicated EKFMAHTB connection kit is required.
In case of EKHBRD*AA* indoor unit, the kit EKMKHT1 is required.
Scope of this manual
This installation manual describes the procedures for installing and
connecting the EKHTSU domestic hot water tank together with the
EKUHWHTA kit.
Model identification
Domestic hot water tank
EKHTSU200AC
Series
Identification of type
U = Special version for United Kingdom only
Hot water Tank Stainless steel
European Kit
The English text is the original instruction. Other languages are
translations of the original instructions.
EKHTSU200+260AC + EKUHWHTA
Domestic hot water tank with UK kit for air to water heat pump system
4PW64052-1 – 08.2010
Installation manual
1
ACCESSORIES
A
K
B
E
F
E
B
M
A
K
H
L
G
J
P
N
G
J
Accessories supplied with the domestic hot water tank
Connection kit for installation of the domestic hot water tank on
the floor next to the indoor unit.
Refer to the installation manual of the kit for more details.
■EKMKHT1
In case the EKHTS*AC domestic hot water tank is to be installed
on top of an EKHBRDAA series indoor unit, the additional
EKMKHT1 kit is required.
Refer to the instruction sheet of the kit for more details.
OVERVIEWOFTHEUNIT
The total system (indoor unit and outdoor unit) is designed
for combination with a Daikin domestic hot water tank. In
case another tank is being used in combination with the
Daikin indoor unit, Daikin cannot guarantee neither good
operation nor reliability of the system. For those reasons
Daikin cannot give warranty of the system in such case.
AHot water out connection
(G 3/4" Female)
BTemperature and pressure
relief valve
ERecirculation connection
(G 1/2" Male)KCold water in connection
FThermistor socket
GFlow inlet connection from
the main indoor unit at the
bottom of the tank (quick
coupling)
HHeat exchanger coil
JReturn outlet connection
to the mainindoor unit at
the bottom of the tank
(quick coupling)
(G 3/4" Female)
LThermistor
MAnode
NCasing
PKnockout holes for water
piping
Installation manual
2
Domestic hot water tank with UK kit for air to water heat pump system
EKHTSU200+260AC + EKUHWHTA
4PW64052-1 – 08.2010
Safety devices
13
10
11
11
12
2
1
5
4
6
8
3
9
1
2
7
772
902
1032
H1
120
Ø60
H2
778
694
443
600
300
11
5
3
9
4
10
B
C
>250
>250
50
D
>30
A
>600
■The domestic hot water tank relief valve connections
may not be used for other purpose.
■This domestic hot water tank can only be used with an
EKHBRD, EKHVMRD, EKHVMYD, EKHVH or EKHVX
indoor unit.
■Thermal protector — The indoor unit is equipped with a thermal
protector. The thermal protector is activated when the
temperature becomes too high. When activated, the protector
has to be reset on the indoor unit by pressing it (for access,
remove the decoration panels like indicated in the manual of the
indoor unit).
Switch off the power supply before opening the
decoration panels of the indoor unit.
Outlook diagram
■Temperature and pressure relief valve
The temperature and pressure relief valve prevents excessive
water temperature (>95°C) and excessive water pressure
(≥10 bar) in the domestic hot water tank.
■Expansion relief valve (EKUHWHTA kit)
The pressure relief valve prevents excessive water pressure
(≥8 bar) in the water circuit.
NOTE
Refer to "Installation of the EKUHWHTA kit on the
domestic hot water tank" on page 11 for connection of
other safety devices in accordance with relevant local
and national regulations.
1Hot water out connection (G 3/4" Female)
2Cold water in connection (G 3/4" Female)
3Hot water out connection at the bottom of the tank (quick coupling)
4Cold water in connection at the bottom of the tank (quick coupling)
5Recirculation connection (G 1/2" Male)
6Flow inlet connection from the main indoor unit (quick coupling)
7Return outlet connection to the main indoor unit (quick coupling)
83-way valve
9Flow inlet connection from the main indoor unit at the bottom of the tank (quick coupling)
10Return outlet connection to the main indoor unit at the bottom of the tank (quick coupling)
11Knockout holes for water piping
12Levelling feet
13Temperature and pressure relief valve (15 mm Male)
Domestic hot water tank modelH1H2
EKHTSU200AC2010 mm1935 mm
EKHTSU260AC2285 mm2230 mm
EKHTSU200+260AC + EKUHWHTA
Domestic hot water tank with UK kit for air to water heat pump system
4PW64052-1 – 08.2010
Installation manual
3
INSTALLATIONOFTHE EKHTSU DOMESTICHOT
3
4
12
1Recirculation connection
4x
4x
WATERTANK
Installing and commisioning the domestic hot water tank
Installing the hot water tank on top of the indoor unit
■Installation shall be done by a licensed technician, the
choice of materials and installation shall comply with
local and national regulations.
■The equipment is not intended for use in a potentially
explosive atmosphere.
■Domestic hot water quality must be according to EU
directive 98/83 EC.
■For safety reasons, it is not allowed to add any kind of
glycol to the water circuit.
■To avoid stagnation of water, it is important that the
storage capacity of the domestic hot water tank meets
the daily consumption of domestic hot water.
In cases where during longer periods of time there is
no consumption of hot water, the equipment must be
flushed with fresh water before usage.
The disinfection function provided on the equipment is
specified in the operation manual of the indoor unit.
■It is advised to avoid long runs of piping between the
domestic hot water tank and the hot water end point
(shower, bath, ...) and to avoid dead ends.
■The installation must be in compliance with local and
national regulations and may require additional
hygienic installation measures.
■For compliance with UK Building Regulations,
thermostatic mixing valves must be installed.
■Immediately after installation, the domestic hot water
tank must be flushed with fresh water. This procedure
must be repeated at least once a day the first 5
consecutive days after installation.
If required by relevant local and national regulations, connect a
recirculation pump in between the hot water end point and the
recirculation connection of the domestic hot water tank.
1Unpack the domestic hot water tank according to the
instructions mentioned on the unpacking instruction sheet.
2Check if all domestic hot water tank accessories are enclosed
(see "Accessories" on page 2).
3Remove the decoration panels and top plates of the indoor unit.
Ta ke away the decoration panels by removing the 2 bottom
screws and then unhitching the panel.
Mount the top plate of the indoor unit on the domestic hot water
tank module.
2x
2x
2x
1
3
1
1
3
2x2x
4Connect the 3-way valve
1A
Only for EKHBRD and
EKHVMR/YD units.
Remove both parts of the drain
plate on top of the indoor unit
before installing the 3-way valve.
2Hot water connection
3Shower
4Recirculation pump
Installation guidelines
Keep in mind the following guidelines when installing the domestic
hot water tank:
■The installation location is frost-free.
■Standard installation location of the domestic hot water tank is
on top of the indoor unit.
If available service space to left and/or right side is
limited, carefully consider all indoor module
installation steps first.
■The domestic hot water tank can be floor mounted as well. In
that case, the dedicated EKFMAHTB connection kit for
installation of the domestic hot water tank next to the indoor unit
is required and to be ordered separately.
■Locate the domestic hot water tank in a suitable position to
facilitate ease of maintenance. Refer to the grey-coloured zones
indicated in the outlook diagram figure and to the installation
manual of the indoor unit.
■To avoid back siphonage it is advised to install a non-return
valve on the water inlet of the domestic hot water tank in
accordance with local and national regulations.
■Ta ke care that in the event of a leak, water can not cause any
damage to the installation space and surroundings.
■If installing an EKHTSU* domestic hot water tank, installing the
kit EKUHWHTA is obligatory. Refer to the UK Building
Regulation G3.
Installation manual
4
B
Only for EKHVH/X indoor units.
Remove the indoor unit switch box by unscrewing fixations
and by then sliding the switch box aside without
disconnecting any wiring connections.
4x
MAX.
15cm
Domestic hot water tank with UK kit for air to water heat pump system
EKHTSU200+260AC + EKUHWHTA
4PW64052-1 – 08.2010
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.