Daikin EKEXFCBAV3, EKEXDCBV3 Operation manuals [sv]

Page 1
INSTALLATIONS- OCH
ANVÄNDARHANDBOK
Tillbehörssats för kombination av
anskaffade förångare
EKEXFCBAV3 EKEXDCBAV3
Page 2
1
1563
2
4
7
9
10 1311
1 2
8
EKEXFCBAV3
2
1563
2
7
12
9
13
8
EKEXDCBAV3
3
L NR3R4 R1 R2Y6Y5Y4Y3Y2Y1
NL
H1
expansion valve gas liquid
Y6Y5Y4Y3Y2Y1
R3T
H2 H3 H4
R2T
outdoor
remocon
P1 P2 C5 C6
F1 F2 T1 T2
error
C1 C2
operation
C3 C4
H6
0-10 V
0 +10
ON/OFF
F2F1
H5
3 4
5
EKEXFCBAV3
4
89 375 61 X24A24
H1
H2 H5 H6
H3 H4
6
5
EKEXFCBAV3
expansion valve gas liquid
L NR3R4 R1
NL
H1
5
Y6Y5Y4Y3Y2Y1
R3T
H2 H3 H4
R2Y6Y5Y4Y3Y2Y1
R2T
air
R5 R6
H6
remocon outdoor
P1 P2
R1T
H7
ON/OFF
F1 F2 T1 T2
H5
H8
F2 F1
EKEXDCBAV3
345 12 10
H1
6
H4H2 H7
H5
H3
H6 H8
EKEXDCBAV3
X24A
Page 3
Tillbehörssats för kombination av Daikin-kondensorenheter
med lokalt anskaffade förångare
Sida
I
NNEHÅLL
EKEXFCBAV3 EKEXDCBAV3
Introduktion ................................................................1
Installation ..................................................................1
Tillbehör............................................................................................. 1
Komponenternas benämning och funktioner..................................... 2
Före installation .................................................................................2
Välja plats för installationen............................................................... 2
Ventilsatsinstallation..........................................................................3
Installation av elreglerboxen.............................................................. 4
Elektriska kopplingar .........................................................................4
Installation av termistorer ..................................................................7
Anslutning av kylrör ........................................................................... 8
Testkörning ........................................................................................8
Drift och underhåll .....................................................8
Att göra före drift................................................................................ 8
Drift- och displaysignaler ................................................................... 9
Felsökning ......................................................................................... 9
Underhåll ......................................................................................... 10
Avfallshantering ...............................................................................10
LÄS DESSA INSTRUKTIONER NOGGRANT FÖRE INSTALLATION OCH ANVÄNDNING.
FELAKTIG INSTALLATION ELLER ANSLUTNING AV UTRUSTNING ELLER TILLBEHÖR KAN ORSAKA ELEK­TRISK CHOCK, KORTSLUTNING, LÄCKAGE, BRAND ELLER ANNAN SKADA PÅ UTRUSTNINGEN. ANVÄND ENDAST TILLBEHÖR FRÅN DAIKIN SOM ÄR SPECIELLT TILLVERKADE FÖR ATT ANVÄNDAS MED UTRUSTNINGEN. LÅT EN YRKESMAN INSTALLERA DEM.
OM DU HAR FRÅGOR ANGÅENDE INSTALLATIONS­FÖRFARANDET ELLER ANVÄNDNINGEN TAR DU KONTAKT MED NÄRMASTE DAIKIN-ÅTERFÖR­SÄLJARE FÖR RÅD OCH INFORMATION.
Installations- och
användarhandbok
Vi skiljer på 2 olika reglerboxar, var och en med sina egna tillämpnings- och installationskrav.
Reglerboxen EKEXFCB (2 möjliga driftlägen)
Drift med 0–10 V insignal för styrning av kapaciteten En extern styrenhet krävs för styrning av kapaciteten. För detaljer om nödvändiga funktioner för den externa styr­enheten, se avsnittet "Drift med 0–10 V kapacitetsstyrning"
på sid 8. Den kan användas för styrning av rums-
temperaturen eller luftutloppstemperaturen. Drift med fast T
Detta system körs med en fast förångningstemperatur.
Reglerbox EKEXDCB Systemet fungerar som en vanlig inomhusenhet för styrning av rumstemperaturen. Detta system kräver ingen specifik extern styrenhet.
NSTALLATION
I
ILLBEHÖR
T
Te r mistor (R1T) 1
Te r mistor (R3T/R2T) (2,5 m kabel)
Isolerskikt 2
Gummiskikt 2
Kabelskarv 4 6
Installations- och användarhandbok
Skruvmutter 6 8
Buntband 6
Kapacitets­inställningsadapter
Plugg (stängningstratt) 2

Obligatoriskt tillbehör

-temperaturkontroll
e
EKEXFCB EKEXDCB
2
1
7
NTRODUKTION
I
Använd endast detta system i kombination med en lokalt anskaffad lufthanteringsenhet. Anslut inte detta system till andra inomhusenheter.
Endast tillbehörskontroller som anges i listan över tillbehör kan användas.
EKEXFCBAV3 + EKEXDCBAV3 Tillbehörssats för kombination av Daikin-kondensorenheter med lokalt anskaffade förångare 4PW30903-3
EKEXFCB EKEXDCB
Expansionsventilsats EKEXV
Se kapitel "Ventilsatsinstallation" på sid 3 för installations- instruktioner.

Extra tillbehör

EKEXFCB EKEXDCB
Fjärrkontroll
(*) Krävs ej för drift. Användbart verktyg för service och installation.
Installations- och användarhandbok
(*)
1
1
1
Page 4
1
2
3
1
2
3
4
5
6
7
8
9
10
11
12
13
K
OMPONENTERNAS
FUNKTIONER
Delar och komponenter
Utomhusenhet Reglerbox (EKEXFCB / EKEXDCB) Lufthanteringsenhet (anskaffas separat) Styrenhet (anskaffas separat) Rör (anskaffas separat) Expansionsventilsats
Kabelanslutningar
Strömförsörjning för utomhusenhet Kabel för reglerbox
(Strömförsörjning och kommunikation mellan reglerbox och utomhusenhet)
Förångartermistorer Kommunikation mellan styrenhet och reglerbox Strömförsörjning och kontrollkablar för förångare
(lufthanteringsenhet) och styrenhet (strömförsörjningen är separat från utomhusenheten)
Lufttermistorstyrning av förångare (lufthanteringsenhet) Fjärrkontroll ( = endast för service)
F
ÖRE
INSTALLATION
(Se bild 1 och bild 2)
BENÄMNING
OCH

Varningar för val av förångare (lufthanteringsenhet)

Se tabellen nedan för tillämpliga enheter. Välj förångare (anskaffas separat) enligt de tekniska data och
begränsningar som anges nedan. Livslängd för utomhusenheten, arbetsområde eller driftssäkerhet kan
påverkas om du inte beaktar dessa begränsningar. Begränsning för utomhusenhet (expansionsventilsats)
Utomhusenhet (klass)
100 EKEXV63~125 200 EKEXV100~250 125 EKEXV63~140 250 EKEXV125~250 140 EKEXV80~140
Beroende på värmeväxlaren måste en anslutningsbar EKEXV (expansionsventilsats) väljas enligt dessa begränsningar.
EKEXV­klass
63 0,96 1,22 6,4 7,8 80 1,22 1,53 8,1 9,9 100 1,53 1,91 10,1 12,3 125 1,91 2,14 12,6 15,4 140 2,14 2,67 14,4 17,6 200 3,06 3,82 20,2 24,6 250 3,82 4,78 25,2 30,8
EKEXV-sats
Tillåten värmeväxlarvolym
Minimum Maximum Minimum Maximum
(dm
3
)
Utomhusenhet (klass)
Tillåten värmeväxlarkapacitet
EKEXV-sats
(kW)
Välja expansionsventil Motsvarande expansionsventil måste väljas för förångaren. Välj
expansionsventil enligt begränsningarna ovan.
OBS!
Val av kapacitetsinställningsadapter (se tillbehör)
Motsvarande kapacitetsinställningsadapter måste väljas beroende på expansionsventilen.
Anslut korrekt förseglad kapacitetsinställningsadapter till X24A (A1P). (Se bild 4 och bild 6)
EKEXV­sats
63 J71 140 J160 80 J90 200 J224 100 J112 250 J280 125 J140
Om du får motstridiga resultat gäller volym före kapacitet.
Expansionsventilen är en elektronisk typ som kontrolleras av termistorer som läggs till i kretsen. Varje expansionsventil kan styra ett antal förångarstorlekar (lufthanterings­enheter).
Den valda förångarenheten måste vara konstruerad för R410A.
Kontrollera att främmande ämnen (som mineraloljor och fukt) inte kommer in i systemet.
SST: mättnadstemperatur för insugning vid förångarens utgång.
Kapacitetsinställ
ningsadapter-
etikett
(indikering)
EKEXV­sats
Kapacitetsinställ
ningsadapter-
etikett
(indikering)

Följande punkter måste utföras extra noggrant och kontrolleras efter installation

Pricka
av
när
kontroll
utförts
Sitter termistorerna fast ordentligt?
Te r mistor kan lossna.
Är frysskyddet korrekt utfört?
Förångaren (lufthanteringsenheten) kan frysa.
Sitter reglerboxen fast ordentligt?
Enheten kan ramla ner, vibrera eller föra oljud.
Uppfyller elektriska anslutningar specifikationerna?
Enheten kan sluta fungera eller komponenter kan börja brinna.
Är elektriska ledningar och rör anslutna som de ska?
Enheten kan sluta fungera eller komponenter kan börja brinna.
Är enheten riktigt jordad?
Läckströmmar är farliga.
Uppfyllelse av direktiv 97/23/EG (Tryckutrustnings­direktivet): Anslut endast en förångare av kategori I eller mindre.
Mättnadstemperatur för insugning (SST) = 6°C, SH (superhettning) = 5 K, lufttemperatur = 27°C DB / 19°C WB.
Välja kondensorenhet Beroende på den nödvändiga kapaciteten för kombinationen
måste en utomhusenhet väljas (se databoken Engineering för kapacitet).
Varje utomhusenhet kan vara ansluten till ett antal förångare (lufthanteringsenheter).
Antalet bestäms av de tillåtna expansionsventilsatserna.
Installations- och användarhandbok
2
ÄLJA
V
Detta är en A-klassad produkt. I en hushållsmiljö kan den här produkten orsaka radiostörningar och användaren måste då vidta lämpliga åtgärder.
Välj en installationsplats som uppfyller följande krav och som även passar kundens önskemål.
PLATS
Tillbehörsboxar (expansionsventil och elreglerbox) kan installeras utomhus och inomhus).
Installera inte tillbehörsboxar i eller på utomhusenheten.
FÖR
INSTALLATIONEN
Tillbehörssats för kombination av Daikin-kondensorenheter
EKEXFCBAV3 + EKEXDCBAV3
med lokalt anskaffade förångare
4PW30903-3
Page 5
5
340
mm
C
1
2
3
4
5
6
7
8
9
A
B
C
1
2
3
4
5
6
Placera inte tillbehörsboxar så att de utsätts för direkt solljus. Direkt solljus ökar temperaturen i tillbehörsboxarna och kan sänka livslängden och påverka funktionen.
Välj en platt och stark monteringsyta. Håll utrymmet framför boxarna fritt för framtida underhåll. Dra el- och signalkablar till förångare (lufthanteringsenhet) minst
1 meter från TV- och radioapparater. Därigenom förhindras störningar i mottagningen. (Störningar kan dock uppstå även om avståndet är minst 1 meter).

Försiktighetsåtgärder

Installera eller använd inte enheten i sådana utrymmen som anges nedan.
Där mineraloljor, som t.ex. skärolja, förekommer. Där luften innehåller höga salthalter, som t ex nära havet. Där svavelhaltiga gaser förekommer, som t.ex. i områden med
varma källor. I fordon eller fartyg. Där spänningen varierar mycket, som t.ex. i fabriker. Där höga koncentrationer av ångor eller stänk finns. Där det förekommer maskiner som genererar elektromagnetiska
vågor. Där det förekommer sura eller alkaliska ångor. Tillbehörsboxarna måste installeras med öppningen nedåt.
ENTILSATSINSTALLATION
V
Mekanisk installation
Ta bort ventilsatsluckan genom att skruva loss 4x M5.
Borra 4 hål i korrekt position (mått enligt bilden nedan) och fäst ventilsatsboxen säkert med 4 skruvar genom de avsedda hålen Ø9 mm.
Hårdlödning
Förbered inlopps-/utloppsröret framför anslutningen (löd inte ännu).
192.
Ta bort den övre och undre rörisoleringen.
Hårdlöd rören.
Kontrollera att filter och ventilhus kyls med en våt trasa och att husets temperatur inte överstiger 120°C vid hårdlödningen.
Kontrollera att övriga komponenter, som elbox, buntband och kablar är skyddade vid hårdlödningen.
Efter hårdlödningen återställer du den nedre rörisoleringen och täcker den med den övre isoleringen (efter att ha tagit bort linern).
Fäst rörfixeringsklämman (C) igen (2x M5).
Kontrollera att rören är helt isolerade. Rörisoleringen måste gå upp över den isolering som du
återställt enligt steg 7. Kontrollera att det inte finns något gap mellan ändarna som kan orsaka kondensdropp (täck slutligen med tejp).
Säkerhetsföreskrifter vid hårdlödning
Utför alltid en kväveblåsning vid hårdlödning. Hårdlödning utan att utföra ett kväveutbyte eller införsel av kväve i rörsystemet kommer att ge upphov till stora mängder oxiderad beläggning på rörens insida, vilket negativt påverkar ventiler och kompressorer i kylsystemet och förhindrar normal drift.
Vid hårdlödning med tillförsel av kväve i rörsystemet måste kvävetrycket justeras till 0,02 MPa med en tryckreducerings­ventil (= precis tillräckligt för att kännas mot huden).
12 345
6
Rör för kylmedel Del som ska hårdlödas Tejp Manöverventil Tr yckreduceringsventil Kväve
6
Utförligare information finns i handboken för utomhusenheten.
Inlopp från utomhusenheten Utlopp till förångare Rörfixeringsklämma
Ta bort rörfixeringsklämman (C) genom att skruva loss 2x M5.
EKEXFCBAV3 + EKEXDCBAV3 Tillbehörssats för kombination av Daikin-kondensorenheter med lokalt anskaffade förångare 4PW30903-3
Installations- och användarhandbok
3
Page 6
Elektrisk installation
C
1 Öppna locket till elboxen (A).
2 Tr yc k ut ENDAST det andra nedre hålet för kabel (B) inifrån och
ut. Skada inte membranet.
3 För igenom ventilkabeln (med kablarna Y1 ... Y6) från regler-
boxen genom membrankabelgenomföringshålet och anslut kablarna till terminalen (C) enligt instruktionerna i steg 4. Dra kabeln ut ur ventilsatsboxen enligt bilden nedan och fäst med buntbandet (D). Se "Elektriska kopplingar" på sid 4 för mer information.
INSTALLATION AV ELREGLERBOXEN (Se bild 4 och
bild 6)
1 Reglerbox 2 Konsoler 3 Huvudkretskort 4 Tr ansformator 5 Te r minal 6 Kretskort (för spänningsomvandling) 7 Kretskort (spänningskälla) 8 Magnetrelä (drift/kompressor PÅ/AV) 9 Magnetrelä (felstatus)
10 Extra kretskort (KRP4)

Mekanisk installation

1 Fäst reglerboxen med konsolerna på monteringsytan.
Använd 4 skruvar (för hål med Ø6 mm).
2 Öppna luckan på reglerboxen.
3 För elkablar: se avsnittet "Elektriska kopplingar" på sid 4.
4 Installera skruvmuttrarna.
5 Täta oanvända öppningar med pluggar (stängningstrattar).
6 Stäng locket ordentligt efter installationen för att säkerställa att
reglerboxen är vattentät.
4 Använd en liten skruvmejsel och följ instruktionerna för anslut-
ning av kablar till terminalen enligt kabeldragningsdiagrammet.
3
1
4
2
5 Kontrollera att kablaget och isoleringen inte hamnar i kläm när
du stänger ventilsatsboxens lock.
6 Stäng ventilsatsboxens lucka (4x M5).

ELEKTRISKA KOPPLINGAR

Alla lokalt anskaffade komponenter och allt material och elarbete måste uppfylla lokala föreskrifter.
Använd endast kopparledningar.
All ledningsdragning måste utföras av behörig elektriker.
En huvudbrytare eller något annat sätt att koppla från
strömmen, med en kontaktseparation för alla poler, måste installeras i den fasta kabeldragningen enligt relevanta lokala och nationella bestämmelser.
Se installationshandboken som medföljer utomhusenheten för dimensioner för spänningsledningen till utomhusenheten, kapacitet för överspänningsskydd och strömbrytare, samt anvisningar för ledningsdragning.
Anslutning av kablar i reglerboxen
1 För anslutning till utomhusenheten och styrenheten (anskaffas
separat): Dra in kablarna genom skruvmuttern och dra åt den ordentligt
för att säkerställa ett fullgott dragskydd och vattenskydd.
2 Kablarna kräver ett ytterligare
dragskydd. Fäst kabeln med det installerade buntbandet.
Installations- och användarhandbok
4
Tillbehörssats för kombination av Daikin-kondensorenheter
EKEXFCBAV3 + EKEXDCBAV3
med lokalt anskaffade förångare
4PW30903-3
Page 7

Försiktighetsåtgärder

Ansluta elkablar: EKEXFCBAV3

Te r mistorkablar och kablar från fjärrkontrollen bör dras minst 50 mm från kablar för spänningsmatning och kablar till styrenheten. Om inte dessa anvisningar följs kan elektriskt brus göra att systemet inte fungerar.
Använd endast kablar enligt specifikationerna och skruva fast alla trådar ordentligt i kopplingsplintarna. Utför kabeldragningen prydligt så att den inte stör annan utrustning. Dåliga kopplingar kan leda till överhettning och i värsta fall överslag och brand.

Anslutnings- och tillämpningstabell

Beskrivning Anslut till Typ av kabel Tvärsnitt (mm2)
L, N,
jord
Y1~Y6
R1,R2
R3,R4
P1,P2 Fjärrkontroll (tillval)
F1,F2
T1,T2 PÅ/AV C1,C2 Felsignal C3,C4 Driftsignal C5,C6 Kapacitetssteg
(*) Rekommenderad storlek (allt kablage måste uppfylla lokala bestämmelser).
(†) Maxlängden beror på vilken extern enhet som är ansluten (styrenhet/relä, ....)
(‡) Driftsignal: Indikerar kompressordrift. (**) Endast nödvändig för kapacitetsstyrda system.
Kraftförsörjning Kraftförsörjning H05VV-F3G2.5 2,5 Strömförsörjning 230 V 1~50 Hz
Expansionsventil-
anslutning
Te r mistor R2T
(vätskerör)
Te r mistor R3T
(gasrör)
Kommunikation
till utomhusenhet
(‡)
Expansionsventilsats LIYCY3 x 2 x 0,75
Utomhusenhet
Styrenhet
(anskaffas lokalt)
(**)
H05VV-F2 x 0,75
LIYCY4 x 2 x 0,75
Anslut kablarna till terminalen enligt kabeldragningsdiagrammet i bild 3. Se bild 4 för kabeldragning till reglerboxen. Hålindikeringen H1 för kabelinföring hänvisar till H1-kabeln för motsvarande kabeldragningsdiagram.
Anslut kablarna enligt specifikationerna i nästa tabell.
Var särskilt försiktig vid anslutning till styrenheten (anskaffas separat). Blanda inte ihop utdatasignalerna (drift eller fel) eller indatasignalerna (PÅ/AV). Detta skulle kunna skada hela systemet.
(*)
Maxlängd (m) Specifikationer
20 Digital utsignal 12 V DC
0,75
Standard 2,5
Max 20
100 Kommunikationslinje 16 V DC
(†)
Analog insignal 16 V DC
Digital insignal 16 V DC
Digital utsignal spänningsfri.
Max 230 V, max 0,5 A
Analog insignal: 0–10 V

Kopplingsschema

A1P.................... Kretskort
A2P.................... Tryckt kretskort (för spänningsomvandling)
A3P.................... Tryckt kretskort (strömförsörjning)
F1U.................... Säkring (250 V, F5A)(A1P)
F2U.................... Säkring (250 V, T1A)(A3P)
F3U.................... Fältsäkring
HAP ................... Lysdiod (servicemonitor grön)
K1R.................... Magnetrelä (drift/kompressor PÅ/AV)
K2R.................... Magnetrelä (felstatus)
KAR, KPR.......... Magnetrelä
Q1DI .................. Jordfelsbrytare
R2T.................... Termistor (vätska)
R3T.................... Termistor (gas)
T1R.................... Transformator (220 V/21,8 V)
X1M,X2M,X3M .. Kopplingsplint
Y1E.................... Elektronisk expansionsventil
X1M-R1/R2........ Termistor vätska
X1M-R3/R4........ Termistor gas
X1M-Y1~6 ......... Expansionsventil
X2M-P1/P2 ........ Kommunikation fjärrkontroll
X2M-C1/C2........ Utsignal: felstatus
X2M-C3/C4........ Utsignal: drift/kompressor PÅ/AV
X2M-T1/T2......... Insignal: PÅ/AV
X2M-F1/F2......... Kommunikation till utomhusenhet
X2M-C5/C6........ Insignal: 0–10 V DC kapacitetskontroll
........... Kabeldragning
L.........................Spänning
N ........................Neutral
, .......... Kontaktdon
......................... Kabelklämma
...................... Skyddsjord (skruv)
............... Separat komponent
............... Tillval
BLK .................... Svart
BLU....................Blå
BRN ...................Brun
GRN...................Grön
GRY ................... Grå
ORG................... Orange
PNK.................... Rosa
RED ...................Röd
WHT................... Vit
YLW ................... Gul
EKEXFCBAV3 + EKEXDCBAV3 Tillbehörssats för kombination av Daikin-kondensorenheter med lokalt anskaffade förångare 4PW30903-3
Installations- och användarhandbok
5
Page 8

Ansluta elkablar: EKEXDCBAV3

Anslut kablarna till terminalen enligt kabeldragningsdiagrammet i bild 5. Se bild 6 för kabeldragning till reglerboxen. Hålindikeringen H1 för kabelinföring hänvisar till H1-kabeln för motsvarande kabeldragningsdiagram.
Anslut kablarna enligt specifikationerna i nästa tabell.

Anslutnings- och tillämpningstabell

Beskrivning Anslut till Typ av kabel Tvärsnitt (mm2)
L, N,
jord
Y1~Y6
R1,R2
R3,R4
R5,R6 Termistor R1T (luft) P1,P2 Fjärrkontroll
F1,F2
T1,T2 PÅ/AV
Kapacitetssteg —Felsignal —Driftsignal
(*) Rekommenderad storlek (allt kablage måste uppfylla lokala bestämmelser).
Kraftförsörjning Kraftförsörjning H05VV-F3G2.5 2,5 Strömförsörjning 230 V 1~50 Hz
Expansionsventil-
anslutning
Te r mistor R2T
(vätskerör)
Te r mistor R3T
(gasrör)
Kommunikation
till utomhusenhet
Expansionsventilsats LIYCY3 x 2 x 0,75
Utomhusenhet
Styrenhet
(anskaffas lokalt)

Kopplingsschema

A1P ....................Kretskort
F1U ....................Säkring (250 V, F5A)(A1P)
F3U ....................Fältsäkring
HAP....................Lysdiod (servicemonitor grön)
KRP4..................Extra kretskort
Q1DI...................Jordfelsbrytare
R1T ....................Termistor (luft)
R2T ....................Termistor (vätska)
R3T ....................Termistor (gas)
T1R ....................Transformator (220 V/21,8 V)
X1M,X3M ...........Kopplingsplint
Y1E ....................Elektronisk expansionsventil
X1M-R1/R2 ........Termistor vätska
X1M-R3/R4 ........Termistor gas
X1M-R5/R6 ........Termistor luft
X1M-Y1~6 ..........Expansionsventil
X1M-P1/P2.........Kommunikation fjärrkontroll
X1M-T1/T2 .........Insignal: PÅ/AV
X1M-F1/F2 .........Kommunikation utomhus
H05VV-F2 x 0,75
LIYCY4 x 2 x 0,75
(*)
Maxlängd (m) Specifikationer
20 Digital utsignal 12 V DC
Normalt: 2,5
Max: 20
0,75
100 Kommunikationslinje 16 V DC
Digital insignal 16 V DC
Tillvalsanslutning: När funktionen för kopplingsboxen måste utökas:
se KRP4A51 för information om inställningar och instruktioner.
Analog insignal 16 V DC
........... Kabeldragning
L......................... Spänning
N........................ Neutral
, ......... Kontaktdon
........................ Kabelklämma
..................... Skyddsjord (skruv)
............... Separat komponent
.............. Tillval
BLK.................... Svart
BLU.................... Blå
BRN................... Brun
GRN................... Grön
GRY................... Grå
ORG .................. Orange
PNK ................... Rosa
RED................... Röd
WHT .................. Vit
YLW................... Gul
Installations- och användarhandbok
6
Tillbehörssats för kombination av Daikin-kondensorenheter
EKEXFCBAV3 + EKEXDCBAV3
med lokalt anskaffade förångare
4PW30903-3
Page 9

INSTALLATION AV TERMISTORER

1 Te r mistorns mest känsliga punkt 2 Maximera kontakten

Fixering av termistorn

Kyltermistorer

Termistorns plats

En korrekt installation av termistorer krävs för att säkerställa fullgod drift:
1. Vätska (R2T) Installera termistorn bakom distributören på den kallaste delen av värmeväxlaren (kontakta leverantören av värmeväxlaren).
2. Gas (R3T) Installera termistorn på värmeväxlarens utlopp så nära värme­växlaren som möjligt.
En utvärdering måste göras för att kontrollera om förångaren är frysskyddad.
Kör testdrift och kontrollera frysskyddet.
Placera termistorkabeln med lätt lutning för att undvika att vatten samlas på termistorn.
Säkerställ en god kontakt mellan termistorn och förångaren. Placera termistorns överkant på förångaren, detta är termistorns mest känsliga punkt.
21
4
5
°
1 Fixera termistorn med isolerande aluminiumtejp (anskaffas
separat) för att säkerställa en god värmeöverföring.
1
2
1 Vätska R2T 2 Gas R3T

Installera termistorkabeln

1 Placera termistorkabeln i en separat skyddstub.
2 Använd alltid ett dragskydd för termistorkabeln för att undvika
belastning på termistorkabeln som kan få termistorn att lossna. Belastning på termistorkabeln eller en termistor som lossnar kan resultera i dålig kontakt och felaktigt temperaturvärde.
1 2
4
5
°
2 Placera den medföljande gummidetaljen runt termistorn (R2T/
R3T) för att undvika att termistorn lossnar med tiden.
3 Fäst termistorn med 2 buntband.
4 Isolera termistorn med den medföljande isoleringen.
Lufttermistor (endast för EKEXDCB)
EKEXFCBAV3 + EKEXDCBAV3 Tillbehörssats för kombination av Daikin-kondensorenheter med lokalt anskaffade förångare 4PW30903-3
Lufttermistorn (R1T) kan installeras antingen i det rum som behöver temperaturstyrning eller i förångarens insugsområde.
OBS!
För rumstemperaturkontroll kan den medföljande termistorn (R1T) bytas ut mot en tillvalssats med fjärrsensor KRCS01-1(A) (beställs separat).
Installations- och användarhandbok
7
Page 10
Installation av längre termistorkabel (R1T/R2T/R3T)
Te r mistorn levereras med en standardkabel på 2,5 m. Denna kabel kan förlängas upp till 20 m.
Installera den längre termistorkabeln med de medföljande kabelskarvarna
1 Klipp kabeln eller bunta ihop resten av termistorkabeln.
Behåll minst 1 m av termistorns originalkabel. Bunta inte ihop kabeln i reglerboxen.
2 Skala kabeln ±7 mm i båda ändar och för in dessa i
kabelskarven.
3 Kläm åt skarven med rätt verktyg (tång).
4 Efter anslutning värmer du krympslangen kring kabelskarven för
att ge en vattentät anslutning.
5 Linda elisoleringstejp kring anslutningen.
6 Placera ett dragskydd före och efter anslutningen.
Anslutningen måste göras på en plats som är tillgänglig.
För en vattentät anslutning kan anslutningen också göras i en kopplingsbox.
Te r mistorkabeln bör dras minst 50 mm från kablar för spänningsmatning. Om inte dessa anvisningar följs kan elektriskt brus göra att systemet inte fungerar.

ANSLUTNING AV KYLRÖR

All extern rördragning måste utföras av en legitimerad kyl­tekniker och måste uppfylla lokala och nationella föreskrifter.
Anslutning av kylrör till utomhusenheten beskrivs i installations­handboken som medföljde utomhusenheten.
Följ utomhusenhetens specifikationer för ytterligare påfyllning, rördiameter och installation.
Den maximalt tillåtna rörlängden beror på utomhusenhetens modell.

TESTKÖRNING

Innan du testkör eller startar driften av enheten måste du kontrollera följande:
Ställ in förångarfläkten på minimalt luftflöde.
Se avsnittet "Följande punkter måste utföras extra noggrant och
kontrolleras efter installation" på sid 2.
När rör för kylvätska och för dränering samt elledningar har monterats, kör en testdrift och skydda enheten.
Öppna avstängningsventilen på gassidan.
Öppna avstängningsventilen på vätskesidan.
Genomföra testkörningen
1. Starta förångaren med fläktdrift.
2. Stäng kontakten T1/T2 (PÅ/AV).
3. Bekräfta att enheten fungerar i enlighet med handboken och
kontrollera om förångaren isats ned (dåligt frysskydd).
Om enheten isats ned: se "Felsökning" på sid 9.
Vid dålig distribution i förångaren kan 1 eller flera
genomgångar i förångaren isas ned ➞ placera termistorn (R2T) här.
Kontrollera att förångarens fläkt körs även när utomhusenhetens kompressor stannat (endast vid frysskyddskontrollen).
Beroende på driftförhållandena (d.v.s. utomhus­temperaturen) är det möjligt att inställningarna måste ändras efter driftsättning.

DRIFT OCH UNDERHÅLL

ATT GÖRA FÖRE DRIFT

Innan du driftsätter systemet bör du kontakta leveran­tören för att få användarhandboken för ditt system.
Se den dedikerade handboken för styrenheten (anskaffas separat) och förångaren (anskaffas separat).
Kontrollera att lufthanteringsenhetens fläkt är PÅ när utomhusenheten körs.
Inställningar på plats för EKEXDCB
Se installationshandboken för både utomhusenheten och fjärrkontrollen.
Inställningar på plats för EKEXFCB
Vid ändring av inställningar:
1. Gör önskade inställningar.
2. Stäng AV strömmen.
3. Ta bort fjärrkontrollen efter service och kontroll av systemet i
kylningsläge. Användning av fjärrkontrollen kan störa systemets normala drift.
4. Ändra inte T1/T2-driftsignalen vid ett strömavbrott.
5. Sätt PÅ strömmen till inomhusenheten och utomhusenheten.
Ställa in temperaturstyrningssystemet
Läge Kodnr. Inställningsbeskrivning
13(23)–0
T
eller SST = förångningstemperatur eller mättnadstemperatur för
e
insugning.
01
02
Drift med 0–10 V kapacitetsstyrning
Insignalen på 0–10 V används endast för denna systemdrift och ligger till grund för kapacitetsstyrningen.
Detta system behöver en separat anskaffad styrenhet med en temperatursensor. Temperatursensorn kan användas för att styra valfri temperatur:
Förångarens insugningsluft
Rumsluft
Förångarens utloppsluft
Programmera den separat anskaffade styrenheten för att generera en signal på 0–10 V inom de angivna förhållandena. Se även grafiken och övriga data i detta avsnitt för mer information.
När måltemperaturen uppnås: 5 V
När mer kapacitet behövs: 5–10 V
När mindre kapacitet behövs: 0–5 V
Drift med 0–10 V kapacitetsstyrning (= fabriksinställning)
Drift med fast T
-temperaturkontroll
e
Installations- och användarhandbok
8
Tillbehörssats för kombination av Daikin-kondensorenheter
EKEXFCBAV3 + EKEXDCBAV3
med lokalt anskaffade förångare
4PW30903-3
Page 11
°C

DRIFT- OCH DISPLAYSIGNALER

+T
max
T=0
T
max
0
A Styrenhetens spänningsutsignal till EKEXFCB
Kapacitetsökningsområde Kapacitetsminskningsområde
Spännings­utsignal
T =[verklig uppmätt temperatur] – [måltemperatur]
T
max
T (°C)
Spänningsutsignal från styrenhet (anskaffas lokalt)
= linjär funktion med T
När T=0 har måltemperaturen uppnåtts.
= maxtemperaturvariationen som definierats vid installationen
Rekommenderat värde för T
5 10 V
=[1°C~5°C].
max
T
max
0 V 5 V 10 V
0
+T
A
max
Drift med fast Te-temperaturkontroll
Förångningstemperaturen (Te) vid vilken drift ska köras kan ställas in med kodnummer enligt nedan.
Läge Kodnr. Inställningsbeskrivning
= 3°C
01
02
03
13(23)–1
(*) Beroende på drifttemperaturförhållanden eller val av förångningsenhet, kan drift
eller säkerhetsaktivering av utomhusenhet ta över och verklig T angiven Te.
04
05
06
07
08
T
e
T
= 4°C
e
Te = 5°C
Te = 6°C (fabriksinställning)
T
= 7°C
e
Te = 8°C
Te = 9°C
Te = 10°C
(*)
skilja sig från
e
Driftinställning vid strömavbrott
Efter ett strömavbrott måste åtgärder vidtas för att säkerställa att driftsignalen T1/T2 har önskad inställning. Annars kan detta ge upphov till driftproblem.
Onormal drift för kondensor
Fel: öppen
C1/C2-felsignal
Utdata
C3/C4-
driftsignal
C5/C6:
Insignal
kapacitetssteg
T1/T2-
driftsignal
(*) Se avsnittet "Drift med 0–10 V kapacitetsstyrning" på sid 8. (†) Se fältinställning 12(22)–5.
Inget fel: stängd
(†)
(relä aktiverat)
Öppen Kompressorn körs ej
Stängd Kompressorn körs
0–10 V
Öppen Ingen kylning begärd Stängd Kylning begärd
eller styrsystem Ingen ström Normal drift. T1/T2 är öppen: ingen
ytterligare feldetektering
Krävs endast för fältinställning 13(23)–0 = 01 0–10 V kapacitetsstyrning
(*)
Förångarens fläkt måste köras innan kylningsdrift
begärs i utomhusenheten.
När driftsignalen aktiveras måste förångaren och
fläkten köras. Detta kommer annars att utlösa en säkring eller göra att förångaren (lufthanterings­enheten) isas ned.

FELSÖKNING

För att installera systemet och möjliggöra felsökning måste du ansluta fjärrkontrollen till tillbehörssatsen.

Detta är inte ett funktionsfel i luftkonditioneraren

Systemet startar inte
Systemet återstartar inte omedelbart efter begärd kylning. Om driftlampan lyser är systemet i normalt drifttillstånd. Det startar inte om direkt eftersom en av säkerhets­anordningarna löst ut för att hindra att systemet blir överbelastat. Systemet slås på igen automatiskt efter 3 minuter.
Systemet startar inte omedelbart efter det att strömmen slagits på. Vänta 1 minut tills mikrodatorn är klar för drift.

Felsökning

Om något av följande fel inträffar, vidtag nedanstående åtgärder och kontakta din återförsäljare.
Systemet måste repareras av en utbildad servicetekniker.
Om en säkerhetsanordning, t.ex. en säkring, en brytare eller en jordfelsbrytare ofta löser ut eller om PÅ/AV-knappen inte fungerar som den ska. Stäng av huvudströmbrytaren.
Läge Kodnr. Inställningsbeskrivning
T1/T2-driftsignalkontakten måste
01
12(22)–5
02
(*) Efter ett strömavbrott måste T1/T2-driftsignalkontakten ändras till öppen (ingen
kylning begärd).
EKEXFCBAV3 + EKEXDCBAV3 Tillbehörssats för kombination av Daikin-kondensorenheter med lokalt anskaffade förångare 4PW30903-3
vara öppen när strömmen åter sätts
(*)
på. Efter ett strömavbrott måste statusen
för T1/T2-driftsignalkontakten (driftbegäran) vara identisk med den initiala T1/T2-kontaktstatusen före strömavbrottet.
Om displayen , numret på enheten och driftlampan blinkar och en felkod visas: Ta kontakt med leverantören och rapportera felkoden.
Om systemet inte fungerar som det ska och inget av de ovan nämnda felen uppstått ska systemet undersökas enligt följande procedurer.
Installations- och användarhandbok
9
Page 12
Om systemet inte fungerar alls
Kontrollera om det är strömavbrott. Vänta tills strömmen kommer tillbaka. Om strömavbrottet inträffar under drift återstartas systemet automatiskt så snart strömmen återkommer.
Kontrollera att säkringarna är hela och att ingen brytare löst ut. Byt säkringen eller återställ brytaren.
Om systemet slutar fungera när driften är klar
Kontrollera om luftintag eller -utlopp på förångaren (lufthanteringsenhet) är blockerat av något föremål. Avlägsna hindret och se till att luften kan strömma fritt.
Kontrollera om luftfiltret är igentäppt. Be en behörig servicetekniker rengöra luftfiltret.
Felsignalen ges och systemet stannar. Om felet återställs efter 5–10 minuter aktiverades enhetens säkerhet, men enheten återstartades efter utvärderingstiden. Om felet kvarstår, kontakta leverantören.
Systemet går, men det kyler inte tillräckligt
Kontrollera om luftintag eller -utlopp på förångaren (lufthanteringsenhet) för utomhusenheten är blockerat av något föremål. Avlägsna hindret och se till att luften kan strömma fritt.
Kontrollera om luftfiltret är igentäppt. Be en behörig servicetekniker rengöra luftfiltret.
Kontrollera om dörrar eller fönster är öppna. Stäng dessa så att vinden inte kan blåsa in i rummet.
Kontrollera om solen lyser direkt in i rummet. Använd gardiner eller persienner.
Kontrollera om det är för många personer i rummet. Kyleffekten minskar om värmetillförseln i rummet är för stor.
Kontrollera om det finns någon värmekälla i rummet. Kyleffekten minskar om värmetillförseln i rummet är för stor.
Förångaren (lufthanteringsenheten) isas ned
Vätsketermistorn (R2T) är inte placerad på den kallaste positionen och en del av förångaren isas ned. Te r mistorn måste placeras på den kallaste positionen.
Te r mistor har lossnat. Te r mistorn måste återställas.
Förångarens fläkt körs inte kontinuerligt. När utomhusenheten stannar måste förångarens fläkt fortsätta köras för att smälta is som ackumulerats under drift av utomhusenheten. Säkerställ att förångarens fläkt fortsätter köras.
Kontakta i dessa fall din leverantör.
ANTECKNINGAR

UNDERHÅLL

Endast en behörig servicetekniker får utföra underhåll.
Innan man gör kontaktdon åtkomliga, måste alla strömkretsar brytas.
Vatten eller rengöringsmedel kan skada elektriska komponenter isolering och orsaka kortslutning i dessa komponenter.

AVFALLSHANTERING

Nedmontering av enheten eller hantering av kylmedel, olja och andra delar ska ske i enlighet med lokala och nationella bestämmelser.
Installations- och användarhandbok
10
Tillbehörssats för kombination av Daikin-kondensorenheter
EKEXFCBAV3 + EKEXDCBAV3
med lokalt anskaffade förångare
4PW30903-3
Page 13
NOTES NOTES
Page 14
Zandvoordestraat 300, B-8400 Oostende, Belgium
4PW30903-3
Loading...