Daikin CTXM15R2V1B, CTXM15R5V1B, FTXM20R2V1B, FTXM20R5V1B, FTXM25R2V1B Installer reference guide [sv]

...
Installatörens referenshandbok
Daikin luftkonditioneringsanläggning
CTXM15R2V1B CTXM15R5V1B
FTXM20R2V1B FTXM20R5V1B FTXM25R2V1B FTXM25R5V1B FTXM35R2V1B FTXM35R5V1B FTXM42R2V1B FTXM42R5V1B
FTXM50R2V1B FTXM60R2V1B FTXM71R2V1B
ATXM20R2V1B ATXM20R5V1B ATXM25R2V1B ATXM25R5V1B ATXM35R2V1B ATXM35R5V1B ATXM50R2V1B
Innehållsförteckning
Innehållsförteckning
1 Om dokumentationen 4
1.1 Om detta dokument ....................................................................................................................................................... 4
2 Allmänna säkerhetsföreskrifter 5
2.1 Om dokumentationen .................................................................................................................................................... 5
2.1.1 Betydelse av varningstexter och symboler .................................................................................................... 5
2.2 För installatören.............................................................................................................................................................. 6
2.2.1 Allmänt............................................................................................................................................................ 6
2.2.2 Installationsplats............................................................................................................................................. 7
2.2.3 Köldmedium – R410A eller R32 ..................................................................................................................... 11
2.2.4 Bärare ............................................................................................................................................................. 12
2.2.5 Vatten ............................................................................................................................................................. 13
2.2.6 Elektricitet....................................................................................................................................................... 13
3 Specifika säkerhetsinstruktioner för installatören 16
4 Om lådan 18
4.1 Översikt: Om lådan ......................................................................................................................................................... 18
4.2 Inomhusenhet................................................................................................................................................................. 18
4.2.1 Hur du packar upp inomhusenheten ............................................................................................................. 18
4.2.2 Så här tar du bort tillbehören från inomhusenheten .................................................................................... 18
5 Om enheten 20
5.1 Systemlayout................................................................................................................................................................... 20
5.2 Driftsvillkor...................................................................................................................................................................... 20
5.3 Om den trådlösa nätverksadaptern................................................................................................................................ 21
5.3.1 Försiktighetsåtgärder vid användning av det trådlösa nätverket.................................................................. 21
5.3.2 Grundläggande parametrar............................................................................................................................ 21
5.3.3 Ställa in den trådlösa adaptern ...................................................................................................................... 22
6 Installation av enheten 23
6.1 Förberedelse av installationsplatsen.............................................................................................................................. 23
6.1.1 Krav på inomhusenhetens installationsplats ................................................................................................. 23
6.2 Öppna inomhusenheten................................................................................................................................................. 24
6.2.1 Så här tar du bort frontpanelen ..................................................................................................................... 24
6.2.2 Så här öppnar du serviceluckan ..................................................................................................................... 25
6.2.3 Så här tar du bort frontgallret ........................................................................................................................ 25
6.3 Montering av inomhusenheten...................................................................................................................................... 26
6.3.1 Så här installerar du monteringsplåten.......................................................................................................... 26
6.3.2 Borra ett hål i väggen ..................................................................................................................................... 27
6.3.3 Så här tar du bort skyddet för rördragningsporten ....................................................................................... 28
6.4 Ansluta dräneringsrör ..................................................................................................................................................... 28
6.4.1 Allmänna riktlinjer .......................................................................................................................................... 28
6.4.2 Så här ansluter du rör på höger sida, baktill på höger sida eller på undersidan till höger ........................... 29
6.4.3 Så här ansluter du rör på vänster sida, baktill på vänster sida eller på undersidan till vänster ................... 30
6.4.4 Så här söker du efter vattenläckor ................................................................................................................. 31
7 Installation av rör 32
7.1 Förbereda köldmedierören ............................................................................................................................................ 32
7.1.1 Köldmediumrörkrav........................................................................................................................................ 32
7.1.2 Isolering av köldmedierören .......................................................................................................................... 33
7.2 Anslutning av köldmedierören ....................................................................................................................................... 33
7.2.1 Om anslutning av köldmediumrör ................................................................................................................. 33
7.2.2 Försiktighetsåtgärder vid anslutning av köldmediumrör .............................................................................. 33
7.2.3 Riktlinjer vid anslutning av köldmediumrör ................................................................................................... 34
7.2.4 Riktlinjer för rörbockning ............................................................................................................................... 35
7.2.5 Flänsning av röränden .................................................................................................................................... 35
7.2.6 Hur du ansluter köldmedierören till inomhusenheten.................................................................................. 36
Installatörens referenshandbok
2
8 Elinstallation 37
8.1 Om att ansluta elledningarna ......................................................................................................................................... 37
8.1.1 Försiktighetsåtgärder vid anslutning av elledningarna.................................................................................. 37
8.1.2 Riktlinjer vid anslutning av elledningarna ...................................................................................................... 38
8.1.3 Specifikationer för standardkablar................................................................................................................. 39
8.2 Så här ansluter du elkablar till inomhusenheten ........................................................................................................... 39
9 Avsluta installationen av inomhusenheten 42
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
Innehållsförteckning
9.1 Så här isolerar du dräneringsrör, köldmediumrör och anslutningskabel ...................................................................... 42
9.2 Så här för du rören genom hålet i väggen...................................................................................................................... 42
9.3 Så här fixerar du enheten på monteringsplåten ............................................................................................................ 43
9.4 Hur du stänger inomhusenheten ................................................................................................................................... 43
9.4.1 Så här sätter du tillbaka frontgallret .............................................................................................................. 43
9.4.2 Så här stänger du serviceluckan..................................................................................................................... 43
9.4.3 Så här sätter du tillbaka frontpanelen ........................................................................................................... 43
10 Konfiguration 45
10.1 Så här anger du en annan adress ................................................................................................................................... 45
11 Driftsättning 47
11.1 Översikt: driftsättning..................................................................................................................................................... 47
11.2 Checklista före driftsättning ........................................................................................................................................... 47
11.3 Utföra en testkörning ..................................................................................................................................................... 48
11.3.1 Så här gör du en testkörning med fjärrkontrollen ......................................................................................... 48
12 Överlämna till användaren 49
13 Kassering 50
14 Tekniska data 51
14.1 Kopplingsschema ............................................................................................................................................................ 51
14.1.1 Enhetsförklaring till kopplingschema ............................................................................................................. 51
15 Ordlista 54
Installatörens referenshandbok
3
1 | Om dokumentationen

1 Om dokumentationen

1.1 Om detta dokument

INFORMATION
Se till att användaren har den tryckta dokumentationen, samt be honom/henne att förvara dem för framtida referensbruk.
Målgrupp
Behöriga installatörer
INFORMATION
Denna utrustning är avsedd att användas av utbildade användare i butiker, lätt industri och på lantbruk, eller för kommersiellt bruk och hemmabruk av icke­fackmän.
Dokumentuppsättning
Detta dokument är en del av en dokumentuppsättning. Den kompletta dokumentuppsättningen består av:
Allmänna försiktighetsåtgärder:
- Försiktighetsåtgärder som du MÅSTE läsa före installation
- Format: Papper (i boxen för inomhusenheten)
Installationshandbok för inomhusenheten:
- Installationsanvisningar
- Format: Papper (i boxen för inomhusenheten)
Installatörens referenshandbok:
- Förberedelse av installationen, goda råd, referensdata, …
- Format: Digitala filer på http://www.daikineurope.com/support-and-manuals/
product-information/
De senaste versionerna av den medföljande dokumentationen kan finnas på Daikins lokala webbplats eller genom din återförsäljare.
Den ursprungliga dokumentationen har skrivits på engelska. Alla andra språk är översättningar.
Tekniska data ▪ Delar av de senaste tekniska data är tillgängliga på den regionala Daikin-
webbplatsen (allmänt tillgänglig).
Installatörens referenshandbok
4
Alla de senaste tekniska data finns på Daikin Business Portal (inloggning krävs).
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
2 | Allmänna säkerhetsföreskrifter

2 Allmänna säkerhetsföreskrifter

2.1 Om dokumentationen

Den ursprungliga dokumentationen har skrivits på engelska. Alla andra språk är
översättningar.
Säkerhetsföreskrifterna i detta dokument omfattar oerhört viktig information, så
det är viktigt att följa dem noggrant.
Installation av systemet, och alla aktiviteter som beskrivs i
installationshandboken samt installatörens referensguide får ENDAST utföras av en behörig installatör.

2.1.1 Betydelse av varningstexter och symboler

FARA
Anger en situation som leder till död eller allvarlig skada.
FARA: RISK FÖR ELCHOCK
Anger en situation som kan leda till att du får en elchock.
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
Indikerar en situation som kan orsaka brännskada/skållning på grund av extremt höga eller låga temperaturer.
FARA: RISK FÖR EXPLOSION
Anger en situation som kan leda till en explosion.
VARNING
Anger en situation som kan leda till död eller allvarlig skada.
VARNING: BRANDFARLIGT MATERIAL
FÖRSIKTIGT
Anger en situation som kan leda till mindre eller måttliga skador.
Symboler som används på enheten:
NOTERING
Anger en situation som kan leda till skador på utrustningen eller lokalen.
INFORMATION
Anger användbara råd eller ytterligare information.
Installatörens referenshandbok
5
2 | Allmänna säkerhetsföreskrifter
Symbol Förklaring
Symboler som används i dokumentationen:
Symbol Förklaring
Läs igenom installations- och bruksanvisningen samt kopplingsinstruktionerna inför installation.
Läs servicehandboken inför underhålls- och serviceuppgifter.
Mer information finns i installations- och användarhandboken.
Enheten innehåller roterande komponenter. Var försiktig vid service eller inspektion av enheten.
Indikerar en bildrubrik eller en referens till den. Exempel: " 1–3 Bildrubrik" betyder "Bild 3 i kapitel 1".
Indikerar en tabellrubrik eller referens till den. Exempel: " 1–3 Tabellrubrik" betyder "Tabell 3 i kapitel 1".

2.2 För installatören

2.2.1 Allmänt

Kontakta din installatör om du INTE är säker på hur du installerar eller använder enheten.
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
Vidrör INTE köldmedierör, vattenledningar eller interna delar under eller
omedelbart efter drift. De kan vara för varma eller för kalla. Vänta tills de återgår till normal temperatur. Använd skyddshandskar om du måste röra vid dem.
Vidrör ALDRIG oavsiktligt läckage av köldmediet.
VARNING
Felaktig installation eller anslutning av utrustning eller tillbehör kan orsaka elchock, kortslutning, läckage, brand eller annan skada på utrustningen. Använd endast tillbehör, extrautrustning och reservdelar som tillverkats eller godkänts av Daikin.
VARNING
Se till att installationen, kontroller och använda material överensstämmer med gällande lagstiftning (utöver instruktionerna i dokumentationen Daikin).
Installatörens referenshandbok
6
FÖRSIKTIGT
Bär lämplig personlig skyddsutrustning (skyddshandskar, säkerhetsglasögon, etc.) under installationen, underhållet eller reparationen av systemet.
VARNING
Riv isär och kasta plastförpackningsmaterialet så att ingen, speciellt barn, inte kan leka med det. Möjlig risk: kvävning.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
2 | Allmänna säkerhetsföreskrifter
VARNING
Vidta nödvändiga åtgärder för att förebygga att smådjur söker skydd i enheten. Smådjur som kommer i kontakt med strömförande delar kan orsaka fel, rökutveckling eller eldsvåda.
FÖRSIKTIGT
Vidrör INTE enhetens luftintag eller aluminiumspjäll eftersom det finns risk för att du skadas.
FÖRSIKTIGT
Placera INTE föremål eller utrustning ovanpå enheten.Sitt INTE, klättra eller stå på enheten.
NOTERING
Arbeten som utförs på utomhusenheten ska helst göras under torra väderförhållanden för att förhindra vatteninträngning.
I enlighet med gällande lagstiftning kan det vara nödvändigt att föra en loggbok över utrustningen. Denna ska alltid innehålla: information om underhåll, reparationsarbete, kontrollresultat, passningstider, etc.
Dessutom SKA minst följande information om systemet vara tillgänglig på lätt åtkomlig plats:
Nedstängningsinstruktioner i händelse av nödfallNamn och adress till brandkår, polis och sjukhusNamn, adress och jourtelefonnummer till serviceavdelningar
I Europa ger EN378 nödvändig ledning för den här loggboken.

2.2.2 Installationsplats

Se till att det finns tillräckligt med utrymme runt enheten för tillräcklig
Kontrollera att golvet är tillräckligt starkt för att bära inomhusenhetens vikt och
Se till att området är väl ventilerat. Blockera ALDRIG några ventilationsöppningar.Se till att enheten står på en jämn yta.
Installera INTE enheten på någon av följande platser:
I miljöer med explosionsrisk.I närheten av maskiner som avger elektromagnetiska vågor. Elektromagnetiska
luftcirkulation.
vibrationer.
vågor kan störa styrsystemet och göra att utrustningen inte fungerar som den ska.
På platser med risk för brand på grund av läckage av brandfarliga gaser (t.ex.
lösningsmedel eller bensin), kolfiber eller lättantändligt damm.
På platser där frätande gas (t.ex. svavelsyrliga gaser) produceras. Korrosion av
kopparledningar eller lödda delar kan orsaka att köldmediet läcker ut.
I badrum.
Installatörens referenshandbok
7
2 | Allmänna säkerhetsföreskrifter
Instruktioner för utrustning med köldmedium R32
VARNING: NÅGOT LÄTTANTÄNDLIGT MATERIAL
Köldmediet i enheten är brandfarligt.
VARNING
Punktera EJ och bränn EJ.Använd INGA andra metoder för att påskynda avfrostningsprocessen eller
rengöring av utrustningen än de som rekommenderas av tillverkaren.
Var medveten om att köldmedium R32 är luktfritt.
VARNING
Utrustningen ska förvaras så att inga mekaniska skador uppstår och i ett väl ventilerat rum utan antändningskällor i kontinuerlig drift (t.ex. öppna lågor, en gasvärmare i drift eller en elvärmare i drift). Rummets dimensioner ska vara enligt nedan.
VARNING
Kontrollera att installation, service, underhåll och reparation följer instruktionerna från Daikin och tillämplig lagstiftning (till exempel nationella regler för gashantering) samt endast utförs av behöriga personer.
VARNING
Om ett eller flera rum ansluts till enheten via ett kanalsystem ska du kontrollera att:
Det inte finns några aktiva antändningskällor (till exempel öppen låga, en aktiv
gasbrännare eller en aktiv elvärmare) om golvytan är mindre än minsta tillåtna golvyta A (m²).
Inga extraenheter, som kan orsaka antändning, är installerade i kanalsystemet (till
exempel heta ytor med en temperatur som överstiger 700°C och elektrisk växlare).
Endast extraenheter som godkänts av tillverkaren används i kanalsystemet.Luftintag OCH luftutlopp är anslutna direkt till samma rum via kanaler. Använd
INTE utrymmen som t.ex. sänkt innertak som kanal för luftintaget eller luftutloppet.
NOTERING
Vidta försiktighetsåtgärder för att undvika överdrivna vibrationer eller pulseringar
i köldmediumrör.
Skyddsenheter, rör och anslutningsdon ska skyddas i så stor utsträckning som
möjligt mot negativa miljöeffekter.
Ta höjd för expansion och sammandragning av långa rör.Rör i köldmediumsystem ska utformas och installeras för att minimera risken för
att hydrauliska stötar skadar systemet.
Inomhusutrustningen och rör ska monteras säkert och skyddas så att utrustning
eller rör inte skadas vid till exempel ommöblering eller rekonstruktion.
Installatörens referenshandbok
8
FÖRSIKTIGT
Använd INTE potentiella antändningskällor när du söker efter eller identifierar köldmediumläckor.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
NOTERING
Contains fluorinated greenhouse gases
2
1
1
1
2
2
kg
tCO2eq
1000
GWP × kg
=
=
+
kg
=
kg
=
GWP: xxx
R32
Återanvänd INTE kopplingar som redan har använts.Installationskopplingar som gjorts mellan delar av köldmediumsystemet ska vara
Krav på installationsutrymme
VARNING
Om apparater innehåller köldmediet R32 MÅSTE golvytan för rummet där apparaterna är installerade, används och förvaras vara större än den minsta golvytan som definieras i tabellen under A (m2). Detta gäller:
Inomhusenheter utan sensor för köldmediumläckage. För inomhusenheter med
Utomhusenheter installerade eller förvarade inomhus (till exempel
Rördragning i oventilerade utrymmen
NOTERING
Rör måste skyddas mot fysiska skador.Rörlängden måste hållas ned till ett minimum.
2 | Allmänna säkerhetsföreskrifter
tillgängligt i underhållssyfte.
sensor för köldmediumläckage, se installationshandboken
vinterträdgård, garage, maskinrum)
Så här bestämmer du minsta golvyta
1 Bestäm total mängd påfyllt köldmedium i systemet (= fabrikspåfyllt
köldmedium + ytterligare påfyllt köldmedium).
2 Bestäm vilket diagram eller vilken tabell du vill använda.
För inomhusenheter: Är enheten takmonterad, väggmonterad eller stående
på golvet?
För utomhusenheter som installeras eller förvaras inomhus samt lokala rör i
oventilerade utrymmen beror detta på installationshöjden:
Om installationshöjden är… Använder du diagrammet eller tabellen
<1,8m Enheter som står på golvet
1,8≤x<2,2M Väggmonterade enheter
≥2,2m Takmonterade enheter
för…
3 Använd diagrammet eller tabellen för att bestämma minsta golvyta.
Installatörens referenshandbok
9
2 | Allmänna säkerhetsföreskrifter
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
1.822.2
2.4
2.6
2.833.2
3.4
3.6
3.844.2
4.4
4.6
4.855.2
5.4
5.6
5.866.2
6.4
6.6
6.877.2
7.4
7.6
7.8
1.843 7.956
8.0
A
min
(m2)
Floor-standing unit
(c)
Wall-mounted unit
(b)
Ceiling-mounted unit
(a)
m (kg)
Ceiling-mounted
unit
(a)
4.6 13.4
4.6 180
4.8 14.6
4.8 196
5.0 15.8
5.0 213
≤1.842
5.2 17.1
≤1.842
5.2 230
1.843 3.64
5.4 18.5
1.843 28.9
5.4 248
2.0 3.95
5.6 19.9
2.0 34.0
5.6 267
2.2 4.34
5.8 21.3
2.2 41.2
5.8 286
2.4 4.74
6.0 22.8
2.4 49.0
6.0 306
2.6 5.13
6.2 24.3
2.6 57.5
6.2 327
2.8 5.53
6.4 25.9
2.8 66.7
6.4 349
3.0 5.92
6.6 27.6
3.0 76.6
6.6 371
3.2 6.48
6.8 29.3
3.2 87.2
6.8 394
3.4 7.32
7.0 31.0
3.4 98.4
7.0 417
3.6 8.20
7.2 32.8
3.6 110
7.2 441
3.8 9.14
7.4 34.7
3.8 123
7.4 466
4.0 10.1
7.6 36.6
4.0 136
7.6 492
4.2 11.2
7.8 38.5
4.2 150
7.8 518
4.4 12.3
7.956 40.1
4.4 165
7.956 539
m (kg)
A
min
(m2)
4.6 20.0
4.8 21.8
5.0 23.6
≤1.842
5.2 25.6
1.843 4.45
5.4 27.6
2.0 4.83
5.6 29.7
2.2 5.31
5.8 31.8
2.4 5.79
6.0 34.0
2.6 6.39
6.2 36.4
2.8 7.41
6.4 38.7
3.0 8.51
6.6 41.2
3.2 9.68
6.8 43.7
3.4 10.9
7.0 46.3
3.6 12.3
7.2 49.0
3.8 13.7
7.4 51.8
4.0 15.1
7.6 54.6
4.2 16.7
7.8 57.5
4.4 18.3
7.956 59.9
Wall-mounted
unit
(b)
m (kg)
A
min
(m2)
Floor-standing
unit
(c)
m (kg)
A
min
(m2)
Installatörens referenshandbok
10
m Total mängd påfyllt köldmedium i systemet
A
Minsta golvyta
min
(a) Ceiling-mounted unit (=Takmonterad enhet)
Daikin luftkonditioneringsanläggning
4P518023-8G – 2020.06
ATXM50R2V1B
(b) Wall-mounted unit (=Väggmonterad enhet)
(c) Floor-standing unit (=Enhet som står på golvet)

2.2.3 Köldmedium – R410A eller R32

Om tillämpligt. Se installationshandboken eller installatörens referenshandbok för mer information.
NOTERING
Se till att köldmedierören överensstämmer med gällande lagstiftning. I Europa är EN378 den gällande standarden.
NOTERING
Se till att utomhusledningar och -anslutningar INTE utsätts för belastning.
VARNING
Under kontroller får du ALDRIG trycksätta apparaterna med ett tryck som överstiger det högsta tillåtna trycket (anges på enhetens märkplåt).
2 | Allmänna säkerhetsföreskrifter
VARNING
Vidta tillräckliga försiktighetsåtgärder i händelse av eldsvåda som orsakas av läckande köldmedium. Om köldmediumångor läcker ut ska området omedelbart ventileras. Möjliga risker:
För hög koncentration av köldmedium i slutna miljöer kan leda till syrebrist.Giftig gas kan produceras om köldmediumångor kommer i kontakt med eld.
FARA: RISK FÖR EXPLOSION
Nedpumpning – läckage av köldmedium. Om du vill tömma systemet och det finns
en läcka i köldmediumkretsen:
Använd INTE enhetens automatiska tömningsfunktion som samlar allt
köldmedium från systemet i utomhusenheten. Trolig konsekvens: Självantändning och explosion i kompressorn på grund av luft som kommer in i driftkompressorn.
Använd ett separat återvinningssystem så att enhetens kompressor INTE behöver
köras.
VARNING
Återvinn ALLTID köldmedium. Släpp ALDRIG ut dem direkt i miljön. Använd en vakuumpump för att evakuera installationen.
NOTERING
När alla rör anslutits ska man kontrollera att inte gas läcker ut. Använd kvävgas för att utföra gasläckagekontroll.
NOTERING
Fyll INTE på mer än den angivna mängden köldmedel eftersom det kan skada
kompressorn.
När köldmediumsystemet ska öppnas MÅSTE köldmedium hanteras enligt
tillämplig lagstiftning.
Installatörens referenshandbok
11
2 | Allmänna säkerhetsföreskrifter
Om påfyllning blir nödvändig finns information på enhetens namnplåt. Här anges
typ av köldmedium och nödvändig mängd.
Utomhusenheten har fyllts på med köldmedium från fabrik och beroende på
rörtjocklek och rörlängder kan vissa system behöva ytterligare påfyllning av köldmedium.
Använd endast verktyg den kylmediumtyp som används i systemet för att
upprätthålla nödvändigt tryck och förhindra att främmande föremål kommer in i systemet.
Fyll på kylmediumvätska som följer:
VARNING
Se till att det inte finns något syre i systemet. Köldmedium får endast fyllas på efter utförd läckagetest och vakuumtorkning.
Trolig konsekvens: Självförbränning och explosion av kompressorn på grund av att syre som kommer in i kompressorn som är i drift.
Om
Ett hävertrör finns
Påfyllning med cylindern upprätt.
(d.v.s. cylindern är markerad med "Liquid filling siphon attached" – hävert för vätskepåfyllning ansluten)
Ett hävertrör finns INTE Påfyllning med cylindern upp och ned.
Öppna kylmediumcylindrar långsamt.Fyll på kylmediet i vätskeform. Om du fyller på det i gasform är normal drift inte
möjlig.
FÖRSIKTIGT
När köldmediumpåfyllningen är slutförd eller när du tar en paus ska du omedelbart stänga ventilen på köldmediumtanken. Om ventilen INTE omedelbart stängs kan det återstående trycket ge ytterligare påfyllning av köldmedium. Trolig konsekvens: Felaktig mängd köldmedium.

2.2.4 Bärare

Installatörens referenshandbok
12
Om tillämpligt. Se installationshandboken eller installatörens referenshandbok för mer information.
VARNING
Valet av bärare MÅSTE ske i enlighet med gällande bestämmelser.
VARNING
Vidta tillräckliga försiktighetsåtgärder vid bärarläckage. Om bärare läcker ut måste utluftning ske omedelbart och därefter kontaktar du din lokala återförsäljare.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

2.2.5 Vatten

2.2.6 Elektricitet

2 | Allmänna säkerhetsföreskrifter
VARNING
Omgivningstemperaturen inuti enheten kan bli mycket högre än rumstemperaturen, t.ex. 70°C. Om bärare läcker ut kan varma delar inuti enheten skapa en riskfull situation.
VARNING
Användning och installation av tillämpningen MÅSTE följa de säkerhets- och miljömässiga föreskrifter som anges i gällande lagstiftning.
Om tillämpligt. Se installationshandboken eller installatörens referenshandbok för mer information.
NOTERING
Se till att vattenkvaliteten uppfyller EU-direktivet 98/83 EG.
FARA: RISK FÖR ELCHOCK
Stäng AV all strömförsörjning innan du tar bort kopplingsboxens lock, ansluter
elkablar eller vidrör elektriska komponenter.
Koppla från strömförsörjningen i mer än 10 minuter, och mät spänningen över
kontakterna för huvudkretsens kondensatorer eller elektriska komponenter innan något servicearbete inleds. Spänningen MÅSTE vara mindre än 50 V likspänning innan du kan röra vid elektriska komponenter. Du kan se var kontakterna finns i kopplingsschemat.
Vidrör INTE elektriska komponenter med fuktiga fingrar.Lämna ALDRIG enheten obevakad när serviceluckan är borttagen.
VARNING
Om enheten INTE är fabriksinstallerad MÅSTE en huvudbrytare eller andra medel för att kunna koppla ifrån enheten installeras, med en kontaktseparation i alla poler som resulterar i fullständig bortkoppling enligt villkoren i överspänningsklassIII, i den fasta kabeldragningen.
Installatörens referenshandbok
13
2 | Allmänna säkerhetsföreskrifter
VARNING
Använd ENDAST kopparledningar.Se till att lokal kabeldragning görs i enlighet med gällande lagstiftning.All lokal kabeldragning MÅSTE utföras i enlighet med kopplingsschemat som
medföljer produkten.
Kläm ALDRIG kabelbuntar och se till att de INTE kommer i kontakt med icke-
isolerade ledningar eller vassa kanter. Kontrollera att ingen extern belastning påfrestar kabelanslutningarna.
Se till att installera jordledare. Jorda INTE enheten till en vattenledning, ett
vågfrontskydd eller en jordledning för telefon. Ofullständig jordning kan leda till elektriska stötar.
Se till att använda en dedikerad strömkrets. Dela ALDRIG strömförsörjning med
någon annan apparat.
Se till att nödvändiga säkringar eller kretsbrytare installeras.Se till att installera en jordfelsbrytare. Om inte detta följs kan det resultera i
elektriska stötar eller eldsvåda.
Vid installation av jordfelsbrytaren ska du kontrollera att den är kompatibel med
invertern (som klarar högfrekvent elektriskt brus) för undvika att jordfelsbrytaren löser ut i onödan.
FÖRSIKTIGT
Vid anslutning av strömkabeln ska jordkabeln anslutas innan någon strömförande
anslutning görs.
Vid frånkoppling av strömkabeln ska strömförande anslutningar kopplas från
innan jordkabeln kopplas från.
Kabellängden mellan strömkabelns anslutning och terminalblocket måste vara
sådan att de strömförande kablarna sträcks före jordkabeln om strömkabeln dras loss från kabelfästet.
NOTERING
Säkerhetsåtgärder vid dragning av elledningar:
Anslut INTE kablar med olika tjocklek till strömförsörjningsplinten (för mycket
spelrum kan orsaka onormal värme).
När du ansluter kablar av samma tjocklek gör du enligt anvisningarna ovan.Vid ledningsdragning använder du angiven strömkabel och ansluter den
ordentligt. Fäst den sedan så att inte plinten utsätts för belastning utifrån.
Använd en lämplig skruvmejsel för att dra åt terminalskruvarna. En skruvmejsel
med för litet huvud förstör skruven och gör det omöjligt att dra åt den.
Om du drar åt terminalskruvarna för hårt kan de gå sönder.
Installatörens referenshandbok
14
VARNING
När du är färdig med elanslutningarna kontrollerar du att alla elektriska
komponenter och kontakter i eldosan är ordentligt anslutna.
Se till att alla skyddskåpor är stängda innan du sätter igång enheten.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
2 | Allmänna säkerhetsföreskrifter
NOTERING
Gäller endast om strömförsörjningen har tre faser och kompressorn har en PÅ/AV startmetod.
Om det föreligger risk för omvänd faskoppling efter tillfälligt strömavbrott och/eller om strömmen kommer och går när produkten är i drift, då kan man montera ett externt fasskydd. Om produkten körs med fasfel kan kompressorn och andra komponenter skadas.
Installatörens referenshandbok
15

3 | Specifika säkerhetsinstruktioner för installatören

3 Specifika säkerhetsinstruktioner för
installatören
Följ alltid följande säkerhetsinstruktioner och föreskrifter. Enhetsinstallation (se "6Installation av enheten"[423])
VARNING
Utrustningen ska förvaras i ett rum utan antändningskällor i kontinuerlig drift (t.ex. öppna lågor, en gasvärmare i drift eller en elvärmare i drift).
VARNING
Placera INGA föremål under inomhus- och/eller utomhusenheten som kan bli fuktiga. Kondens på huvudenheten eller köldmediumrör, smuts från luftfiltret eller blockering av dräneringen kan orsaka att vätska droppar ned och orsakar nedsmutsning eller skador.
FÖRSIKTIGT
Om väggen innehåller en metallram eller metallplattor använder du ett vägginbäddat rör och en skyddskåpa för hålet för att förebygga värmeutveckling, elektriska stötar och eldsvåda.
Rördragning (se "7Installation av rör"[432])
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
FÖRSIKTIGT
Använd kragkopplingsmuttern som är fäst på enheten.Sätt lite kylmaskinolja enbart på kragmutterns inre yta för att förhindra att gas
läcker ut. Använd kylmaskinolja för R32.
Återanvänd INTE kopplingar.
FÖRSIKTIGT
Använd INTE mineralolja på den flänsade delen.Installera ALDRIG en avfuktare för denna R32-enhet för att garantera dess
livslängd. Torkningsmaterialet kan lösas upp och skada systemet.
FÖRSIKTIGT
Ofullständig flänsning kan orsaka att köldmediegas läcker ut.Återanvänd INTE flänsar. Använd nya flänsar för att förhindra läckage av
köldmediegasen.
Använd endast de kragmuttrar som följer med enheten. Om du använder andra
kragmuttrar kan köldmediegas läcka ut.
Installatörens referenshandbok
16
Elektrisk installation (se "8Elinstallation"[437])
FARA: RISK FÖR ELCHOCK
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
3 | Specifika säkerhetsinstruktioner för installatören
VARNING
All kabeldragning FÅR ENDAST utföras av en auktoriserad elektriker och MÅSTE
följa gällande bestämmelser.
Gör alla elektriska anslutningar till den fasta kabeldragningen.Alla komponenter som anskaffats lokalt och alla elektriska konstruktioner SKALL
följa gällande bestämmelser.
VARNING
Om strömmatningen saknar eller har fel N-fas kan utrustningen förstöras.Upprätta korrekt jordning. Jorda INTE enheten till en vattenledning, ett
vågfrontskydd eller en jordledning för telefon. Ofullständig jordning kan leda till elektriska stötar.
Installera nödvändiga säkringar eller kretsbrytare.Säkra elkablarna med buntband så att de INTE kommer i kontakt med vassa
kanter eller rör, särskilt på högtryckssidan.
Använd INTE skarvade kablar, fåtrådiga ledare, förlängningssladdar eller
fasfördelade anslutningar. De kan orsaka överhettning, elektrisk chock eller eldsvåda.
Installera INTE en fasförskjutande kondensator, eftersom enheten är försedd med
en inverter. En fasförskjutande kondensator försämrar prestandan och kan orsaka olyckor.
VARNING
Använd ALLTID flerkärniga kablar till strömförsörjningsledningar.
VARNING
Använd en huvudbrytare med minst 3 mm mellan kontaktpunkterna, vilken ger fullständig bortkoppling enligt villkoren i överspänningsklass III.
VARNING
Om strömsladden är skadad MÅSTE den bytas ut av tillverkaren, en serviceagent eller andra kvalificerade personer för att undvika faror.
VARNING
Anslut INTE strömsladden till inomhusenheten. Detta kan leda till elektriska stötar eller brand.
VARNING
Använd INGA lokalt införskaffade elkomponenter inuti produkten.Förgrena ALDRIG ström för dräneringspumpen eller något annat från
kopplingsplinten. Detta kan leda till elektriska stötar eller brand.
VARNING
Separera alltid anslutningsledningar från kopparrör utan värmeisolering eftersom dessa rör kan bli väldigt varma.
Installatörens referenshandbok
17
4 | Om lådan
fe1d e2ba c g h i j

4 Om lådan

4.1 Översikt: Om lådan

Detta kapitel beskriver vad som måste göras när lådan med inomhusenheten levererats till platsen.
Här finns information om:
Uppackning och hantering av enhetenBorttagning av tillbehör från enheten
Tänk på följande:
Enheten MÅSTE kontrolleras för skador vid leveransen. Eventuella skador SKA
omedelbart anmälas till transportbolagets skaderepresentant.
Placera den förpackade enheten så nära installationsplatsen som möjligt för att
skydda den från transportskador.
Vid skötsel av enheten beaktas nedanstående:
Ömtåligt, hantera enheten försiktigt.
Förvara alltid enheten stående upprätt för att undvika skador.
Förbered den väg där enheten ska transporteras in.

4.2 Inomhusenhet

4.2.1 Hur du packar upp inomhusenheten

4.2.2 Så här tar du bort tillbehören från inomhusenheten

Installatörens referenshandbok
18
1 Ta bort:
tillbehören i förpackningens botten,monteringsplåten som finns på inomhusenhetens baksida,den extra SSID-dekalen på frontgallret.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
4 | Om lådan
a Installationshandbok b Bruksanvisning c Allmänna försiktighetsåtgärder
d Extra SSID-dekal e1 Klass 15~42: Silverpartikelluftfilter för luftrening (utan ram) e2 Klass 50~71: Luktreducerande titanapatitfilter och silverpartikelluftfilter för borttagning av allergener (med
ram)
f Skruvar för inomhusenheten (M4×12L). Se "9.3Så här fixerar du enheten på monteringsplåten"[443]. g Batteri AAA.LR03 (alkaliska) för fjärrkontroll h Hållare för fjärrkontrollen
i Fjärrkontroll
j Monteringsplåt
Extra SSID-dekal. Kasta INTE bort extradekalen. Förvara den på en säker plats om
den skulle behövas i framtiden (t.ex. om frontgallret byts sätter du den på det nya frontgallret).
Installatörens referenshandbok
19
5 | Om enheten
d
c
f
h1 h2
g
e
b
a

5 Om enheten

5.1 Systemlayout

VARNING: NÅGOT LÄTTANTÄNDLIGT MATERIAL
Köldmediet i enheten är brandfarligt.
a Frontlucka b Servicelucka c Täta rörhålen med kitt d Köldmediumrör, dräneringsslang och kabel mellan enheter e Intelligent eye-sensor
f Isoleringstejp
g Luftfilter h1 Klass 15~42: Silverpartikelluftfilter för luftrening (utan ram) h2 Klass 50~71: Luktreducerande titanapatitfilter och silverpartikelluftfilter för borttagning av allergener (med
ram)

5.2 Driftsvillkor

Installatörens referenshandbok
20
Använd systemet vid följande temperaturer och luftfuktigheter så blir driften säker och effektiv.
I kombination med utomhusenhet RZAG
Kylning och
avfuktning
(a)(b)
Uppvärmning
Utomhustemperatur –20~52°CDB –20~24°CDB
–21~18°CWB
Inomhustemperatur 17~38°CDB
10~27°CDB
12~28°CWB
Luftfuktighet inomhus ≤80%
(a)
En skyddsenhet kan avbryta systemdriften om enheten körs utanför driftintervallet.
(b)
Kondens och droppande vatten kan uppstå om enheten körs utanför driftintervallet.
(b)
I kombination med utomhusenheter: RXM71R, 2MXM, 2AMXM, 3MXM,
3AMXM, 4MXM, 5MXM
Kylning och
avfuktning
(a)(b)
Uppvärmning
Utomhustemperatur –10~46°CDB –15~24°CDB
Inomhustemperatur 18~37°CDB
14~28°CWB
–15~18°CWB
10~30°CDB
Daikin luftkonditioneringsanläggning
4P518023-8G – 2020.06
(a)
(a)
ATXM50R2V1B
5 | Om enheten
I kombination med utomhusenheter: RXM71R, 2MXM, 2AMXM, 3MXM,
3AMXM, 4MXM, 5MXM
Kylning och
avfuktning
Luftfuktighet inomhus ≤80%
(a)
En skyddsenhet kan avbryta systemdriften om enheten körs utanför driftintervallet.
(b)
Kondens och droppande vatten kan uppstå om enheten körs utanför driftintervallet.
(a)(b)
(a)
I kombination med andra utomhusenheter
Kylning och
avfuktning
(a)(b)
Utomhustemperatur –10~50°CDB –20~24°CDB
Uppvärmning
Uppvärmning
–21~18°CWB
(a)
(a)
Inomhustemperatur 18~37°CDB
14~28°CWB
Luftfuktighet inomhus ≤80%
(a)
En skyddsenhet kan avbryta systemdriften om enheten körs utanför driftintervallet.
(b)
Kondens och droppande vatten kan uppstå om enheten körs utanför driftintervallet.
(b)

5.3 Om den trådlösa nätverksadaptern

Detaljerade specifikationer, installationsanvisningar, installationsmetoder, FAQ, konformitetsförsäkran och den senaste versionen av denna handbok finns på
http://www.onlinecontroller.daikineurope.com.
INFORMATION
Daikin Industries Czech Republic s.r.o. förklarar att radioutrustningstypen i den
här enheten följer EU-direktivet 2014/53/EU.
Denna enhet anses vara en kombinerad utrustning enligt definitionen i direktiv
2014/53/EU.

5.3.1 Försiktighetsåtgärder vid användning av det trådlösa nätverket

10~30°CDB
Använd INTE nära:
Medicinsk utrustning. Till exempel defibrillatorer eller personer med pacemaker.
Den här produkten kan orsaka elektromagnetiska störningar.
Utrustning för automatisk styrning. Till exempel automatiska dörrar eller
brandlarm. Den här produkten kan störa utrustningens funktion.
Mikrovågsugn. Den kan störa den trådlösa kommunikationen.

5.3.2 Grundläggande parametrar

Vad Värde
Frekvensomfång 2400MHz~2483,5MHz
Radioprotokoll IEEE 802.11b/g/n
Radiofrekvenskanal 1~13
Uteffekt 13dBm
Installatörens referenshandbok
21
5 | Om enheten

5.3.3 Ställa in den trådlösa adaptern

Installation av applikationen Daikin Residential Controller
Vad Värde
Effektiv utstrålad effekt 15dBm (11b) / 14dBm (11g) / 14dBm
(11n)
Strömförsörjning DC 14 V/100 mA
Kunden ansvarar för:
Smartphone eller surfplatta med den senaste understödda versionen av Android
eller iOS enligt http://www.onlinecontroller.daikineurope.com
Internet-anslutning och kommunikationsenhet, som modem, router o.s.v.Åtkomstpunkt för trådlöst nätverk.Installation av den kostnadsfria Daikin Residential Controller-appen.
1 Öppna:
Google Play för enheter som använder Android.App Store för enheter som använder iOS.
2 Sök efter Daikin Residential Controller. 3 Följ anvisningarna på skärmen för att installera.
Installatörens referenshandbok
22
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

6 Installation av enheten

I detta kapitel
6.1 Förberedelse av installationsplatsen...................................................................................................................................... 23
6.1.1 Krav på inomhusenhetens installationsplats ......................................................................................................... 23
6.2 Öppna inomhusenheten......................................................................................................................................................... 24
6.2.1 Så här tar du bort frontpanelen ............................................................................................................................. 24
6.2.2 Så här öppnar du serviceluckan ............................................................................................................................. 25
6.2.3 Så här tar du bort frontgallret................................................................................................................................ 25
6.3 Montering av inomhusenheten.............................................................................................................................................. 26
6.3.1 Så här installerar du monteringsplåten ................................................................................................................. 26
6.3.2 Borra ett hål i väggen ............................................................................................................................................. 27
6.3.3 Så här tar du bort skyddet för rördragningsporten............................................................................................... 28
6.4 Ansluta dräneringsrör............................................................................................................................................................. 28
6.4.1 Allmänna riktlinjer .................................................................................................................................................. 28
6.4.2 Så här ansluter du rör på höger sida, baktill på höger sida eller på undersidan till höger................................... 29
6.4.3 Så här ansluter du rör på vänster sida, baktill på vänster sida eller på undersidan till vänster ........................... 30
6.4.4 Så här söker du efter vattenläckor......................................................................................................................... 31

6.1 Förberedelse av installationsplatsen

6 | Installation av enheten
Installera INTE enheten på platser som ofta används som arbetsplats. Vid byggarbeten (t.ex. slipning) där mycket damm skapas MÅSTE enheten täckas över.
Välj en installationsplats med tillräckligt utrymme för att kunna bära enheten in och ut från platsen.
VARNING
Utrustningen ska förvaras i ett rum utan antändningskällor i kontinuerlig drift (t.ex. öppna lågor, en gasvärmare i drift eller en elvärmare i drift).

6.1.1 Krav på inomhusenhetens installationsplats

INFORMATION
Läs även säkerhetsföreskrifterna i kapitlet “Allmänna säkerhetsföreskrifter”.
INFORMATION
Ljudtrycksnivån understiger 70dBA.
Luftflöde. Se till att inget blockerar luftflödet.Dränering. Se till att kondensvattnet kan tömmas ordentligt.Väggisolering. Om förhållandena i väggen överstiger 30°C och relativ
luftfuktighet på 80% eller om friskluften är indragen genom taket behövs extra isolering (minst 10mm tjockt PE-skum).
Väggens bärighet. Kontrollera att väggen eller golvet har tillräcklig bärighet för
att klara enhetens vikt. Vid tveksamhet bör väggen eller golvet förstärkas innan enheten installeras.
Installera strömkablar på minst 1meters avstånd från tv- eller radioapparater för att förebygga störningar. Beroende på radiovågorna kan ett avstånd på 3meter INTE vara tillräckligt.
Installatörens referenshandbok
23
6 | Installation av enheten
≥50
≥50
≥30
(mm)
Välj en plats där driftbuller och kall-/varmluften som enheten avger inte orsakar
någon olägenhet.
Lysrör. Vid installation av ett trådlöst användargränssnitt i ett rum med lysrör ska
du beakta följande för att undvika störningar:
- Installera det trådlösa användargränssnittet så nära inomhusenheten som
möjligt.
- Installera inomhusenheten så långt bort som möjligt från lysrören.
Vi rekommenderar INTE att du installerar enheten på följande platser eftersom det kan förkorta enhetens livslängd:
Där spänningsstyrkan fluktuerar mycketI fordon eller fartygDär sura eller alkaliska ångorPlatser där mineraloljedimma, oljesprej eller ånga kan finnas i luften. Plastdelar
kan skadas och trilla av eller orsaka en vattenläcka.
På platser där enheten står i direkt solljus.I badrum.Ljudkänsliga områden (t.ex. i närheten av ett sovrum) så att driftsljudet inte stör.
VARNING
Placera INGA föremål under inomhus- och/eller utomhusenheten som kan bli fuktiga. Kondens på huvudenheten eller köldmediumrör, smuts från luftfiltret eller blockering av dräneringen kan orsaka att vätska droppar ned och orsakar nedsmutsning eller skador.
Avstånd. Installera enheten minst 1.8 meter från golvet och ha följande krav i
åtanke för avstånd från väggar och innertak:

6.2 Öppna inomhusenheten

6.2.1 Så här tar du bort frontpanelen

1 Håll frontpanelen i panelflikarna på båda sidor och öppna den.
Installatörens referenshandbok
24
2 Ta bort frontpanelen genom att skjuta den åt vänster eller åt höger och dra
den mot dig.
Resultat: Frontpanelaxeln på 1 sida lossas.
3 Koppla sedan bort frontpanelaxeln på andra sidan på samma sätt.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
a
a Frontpanelaxel
a b
1
2
3 4
b
a
a

6.2.2 Så här öppnar du serviceluckan

1 Ta bort 1 skruv från frontluckan. 2 Dra ut serviceluckan vågrätt från enheten.
a Skruv för serviceluckan b Servicelucka
6 | Installation av enheten
NOTERING
Var noga med att dra fast serviceluckan med åtdragningsmoment som INTE överstiger 1,4(±0,2)N•m.

6.2.3 Så här tar du bort frontgallret

FÖRSIKTIGT
Bär lämplig personlig skyddsutrustning (skyddshandskar, säkerhetsglasögon, etc.) under installationen, underhållet eller reparationen av systemet.
1 Ta bort frontpanelen för att ta bort luftfiltret. 2 För klass 50~71 ta klaffen (vågrätt blad). Tryck bladets vänstra sida mot mitten
och kroka av det. Tryck bladets högre sida mot mitten och kroka av det från axeln. Koppla från de 2 centrumanslutningspunkterna.
3 Ta bort 2 skruvar (klass 15~42) eller 3 skruvar (Klass 50~71) från frontgallret. 4 Tryck ned de övre 3 krokarna märkta med en symbol med 3 cirklar.
a Övre krok b Symbol med 3 cirklar
Installatörens referenshandbok
25
6 | Installation av enheten
1
2

6.3 Montering av inomhusenheten

I detta kapitel
5 Vi rekommenderar att du öppnar klaffen innan du tar bort frontgallret. 6 Placera båda händerna under frontgallrets centrum och tryck uppåt och sedan
mot dig.
6.3.1 Så här installerar du monteringsplåten ................................................................................................................. 26
6.3.2 Borra ett hål i väggen ............................................................................................................................................. 27
6.3.3 Så här tar du bort skyddet för rördragningsporten............................................................................................... 28

6.3.1 Så här installerar du monteringsplåten

1 Installera monteringsplåten tillfälligt. 2 Se till att monteringsplåten är i våg. 3 Markera centrum för borrhålen på väggen med ett måttband. Placera ena
änden av måttbandet vid symbolen " ".
4 Slutför installationen genom att fästa monteringsplåten på väggen med
M4×25L-skuvar (anskaffas lokalt).
Klass 15~42 Klass 50~71
INFORMATION
Skyddet som du tagit bort från hålen för rören kan du förvara i fickan i monteringsplåten.
Installatörens referenshandbok
26
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
6 | Installation av enheten
169
279
377.5
778
A
295
44.5
160
53
53
44.5
120
120
293.5
50
170
A
d
e
(mm)
a
a
f
h g
a
a
bac
a
c
a
d
e
A
A
998
299
170
60
170
52
52
120.5
130
53
65
469
475
PIPING HOLE CENTER:170mm TO THE LEFT
PIPING HOLE CENTER:170mm TO THE LEFT
(mm)
A
PIPING HOLE CENTER:170mm TO THE LEFT
PIPING HOLE CENTER:170mm TO THE LEFT
e
d
e
d
b
a
c
a
c
a
a
gh
f
a
B
A För klass: 15~42
B För klass: 50~71 a Rekommenderade fästpunkter för monteringsplåten f Placera måttbandet vid symbolen " " b Ficka för skyddet för rördragningsporten g Gasrör
c Flikar för placering av ett vattenpass h Vätskerör
d Genomföringshål i väggen: e Dräneringsslang
Klass 15~42 Ø65mm Klass 50~71 Ø80mm

6.3.2 Borra ett hål i väggen

FÖRSIKTIGT
Om väggen innehåller en metallram eller metallplattor använder du ett vägginbäddat rör och en skyddskåpa för hålet för att förebygga värmeutveckling, elektriska stötar och eldsvåda.
NOTERING
Var noga med att täta glappen runt rören med tätningsmaterial (anskaffas lokalt) för att förhindra vattenläckage.
Installatörens referenshandbok
27
1 Borra ett stort genomföringshål med 65mm (klass 15~42) eller 80mm (klass
50~71) diameter i väggen, med en sluttning ned mot utsidan.
2 För in ett vägginbäddat rör hålet. 3 Sätt en skyddskåpa runt röret.
6 | Installation av enheten
Ø65/80
a
b
c

6.3.3 Så här tar du bort skyddet för rördragningsporten

a Vägginbäddade rör
b Kitt
c Lock för vägghål
4 När du är färdig med kabeldragningen och rören för köldmedium och
dränering ska du INTE glömma att täta öppningen med ett tätningsmaterial.
För anslutning av rör på höger sida, baktill på höger sida, på vänster sida eller på undersidan till vänster MÅSTE skyddet för rördragningsporten tas bort.
1 Skär av locket för rördragningsporten från insidan på frontgallret med en
bågsåg.
2 Ta bort grader längs den sågade kanten med en halvrund nålfil.
NOTERING
Använd INTE avbitartång för att ta bort locket för rördragningsporten eftersom detta skadar frontgallret.

6.4 Ansluta dräneringsrör

I detta kapitel
6.4.1 Allmänna riktlinjer .................................................................................................................................................. 28
6.4.2 Så här ansluter du rör på höger sida, baktill på höger sida eller på undersidan till höger................................... 29
6.4.3 Så här ansluter du rör på vänster sida, baktill på vänster sida eller på undersidan till vänster ........................... 30
6.4.4 Så här söker du efter vattenläckor......................................................................................................................... 31

6.4.1 Allmänna riktlinjer

Rörlängd. Håll dräneringsrören så korta som möjligt.Rördimension. Om en dräneringsslangen behöver förlängas eller om infällda
Installatörens referenshandbok
28
dräneringsrör behövs ska du använda lämpliga komponenter som passar slangkopplingen.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
6 | Installation av enheten
Ø16
Ø18
a
a
b c
Ø16
Ø16
a b c
Ø18
≥50
mm
NOTERING
Installera dräneringsslangen så att den sluttar nedåt.INGA vattenlås är tillåtna.Placera INTE änden av slangen i vatten.
Förlängningsslang för dränering. Du kan förlänga dräneringsslangen med en
lokalt anskaffad slang med 16 mm innerdiameter. Glöm INTE att värmeisolera den del av förlängningsslangen som ska vara inomhus.
a Dräneringsslang som medföljer inomhusenheten b Värmeisolerande rör (anskaffas lokalt) c Förlängningsslang för dränering
Styvt vinylrör. Vid anslutning av ett styvt vinylrör (nominellt Ø13 mm) direkt till
dräneringsslangen som vid inbäddade rör ska du använda en lokalt anskaffad dräneringsfattning (nominellt Ø13mm).
a Dräneringsslang som medföljer inomhusenheten b Dräneringsfattning med nominellt Ø13mm (anskaffas lokalt) c Styvt vinylrör (anskaffas lokalt)
Kondens. Vidta åtgärder mot kondens. Isolera hela dräneringsrördragningen i
byggnaden.
1 För in dräneringsslangen i dräneringsröret som visas i följande bild så att den
INTE kan dras ut ur dräneringsröret.

6.4.2 Så här ansluter du rör på höger sida, baktill på höger sida eller på undersidan till höger

INFORMATION
Fabriksstandard är rördragning på höger sida. För rördragning på vänster sida tar du bort rör från höger sida och installerar på vänster sida.
Installatörens referenshandbok
29
6 | Installation av enheten
A
B
C
a
b
a
a
b
a
b

6.4.3 Så här ansluter du rör på vänster sida, baktill på vänster sida eller på undersidan till vänster

1 Fäst dräneringsslangen under köldmediumrören med vinyltejp. 2 Linda samman dräneringsslangen och köldmediumrören med isoleringstejp.
A Rördragning på höger sida B Rördragning på undersidan till höger
C Rördragning baktill på höger sida
a Ta bort rörportskyddet här för rördragning på höger sida
b Ta bort rörportskyddet här för rördragning på höger undersida
INFORMATION
Fabriksstandard är rördragning på höger sida. För rördragning på vänster sida tar du bort rör från höger sida och installerar på vänster sida.
1 Ta bort isoleringsfästskruven till höger och ta bort dräneringsslangen. 2 Ta bort dräneringspluggen på vänster sida och sätt dit den till höger.
NOTERING
Använd INTE smörjmedel (kylmaskinolja) vid införing av dräneringspluggen. Detta kan skada dräneringspluggen och orsaka läckage.
a 4mm sexkantsnyckel
3 Sätt in dräneringsslangen på vänster sida och glöm inte att fästa den med
fästskruven så att inget läckage uppstår.
a Isoleringsfästskruv
b Dräneringsslang
4 Fäst dräneringsslangen på undersidan av köldmediumrören med vinyltejp.
Installatörens referenshandbok
30
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
A
B
C
b
a
A Rördragning på vänster sida B Rördragning baktill på vänster sida C Rördragning på undersidan till vänster
a Ta bort rörportskyddet här för rördragning på vänster sida
b Ta bort rörportskyddet här för rördragning på vänster undersida

6.4.4 Så här söker du efter vattenläckor

1 Ta bort luftfiltret. 2 Fyll gradvis på med cirka 1liter vatten i dräneringstråget och kontrollera så att
inga vattenläckor finns.
6 | Installation av enheten
Installatörens referenshandbok
31
7 | Installation av rör
t
Ø

7 Installation av rör

I detta kapitel

7.1 Förbereda köldmedierören

7.1.1 Köldmediumrörkrav

7.1 Förbereda köldmedierören .................................................................................................................................................... 32
7.1.1 Köldmediumrörkrav ............................................................................................................................................... 32
7.1.2 Isolering av köldmedierören .................................................................................................................................. 33
7.2 Anslutning av köldmedierören ............................................................................................................................................... 33
7.2.1 Om anslutning av köldmediumrör ......................................................................................................................... 33
7.2.2 Försiktighetsåtgärder vid anslutning av köldmediumrör ...................................................................................... 33
7.2.3 Riktlinjer vid anslutning av köldmediumrör........................................................................................................... 34
7.2.4 Riktlinjer för rörbockning ....................................................................................................................................... 35
7.2.5 Flänsning av röränden............................................................................................................................................ 35
7.2.6 Hur du ansluter köldmedierören till inomhusenheten ......................................................................................... 36
INFORMATION
Läs även säkerhetsföreskrifterna i kapitlet “Allmänna säkerhetsföreskrifter”.
Främmande material i rören (inklusive oljor för tillverkning) måste vara
≤30mg/10m.
Köldmediumrördiameter
Använd samma diameter som anslutningar till utomhusenheterna:
Köldmediumrörmaterial
Rörmaterial: Sömlösa kopparrör avoxiderade med fosforsyra.Kragkopplingar: Använd anlöpt material.Rörmaterials härdningsgrad och godstjocklek:
Yttre diameter (Ø) Härdningsgrad Tjocklek (t)
NOTERING
Rör och andra tryckförande komponenter ska vara lämpliga för kylmedium. Använd sömlösa kopparrör, avoxiderade med fosforsyra, för kylmedium.
Klass Ytterdiameter på rör (mm)
Vätskerör Gasrör
15~42 Ø6,4 Ø9,5
50~60 Ø6,4 Ø12,7
71 Ø6,4 Ø15,9
(a)
6,4mm (1/4") Anlöpt (O) ≥0,8mm
9,5mm (3/8")
12,7mm (1/2")
15,9mm (5/8")
(a)
Beroende på tillämplig lagstiftning och enhetens maximala arbetstryck (se "PS High" på enhetens märkskylt) kan större rörtjocklek behövas.
Installatörens referenshandbok
32
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

7.1.2 Isolering av köldmedierören

ØiØ
i
t
ØpØ
p
Använd polyetenskum som isoleringsmaterial:
- med en värmeöverföringshastighet mellan 0,041 och 0,052W/mK (0,035 och
0,045kcal/mh°C)
- med en värmebeständighet på minst 120°C
Isoleringens tjocklek
7 | Installation av rör
Rörets yttre diameter (Øp) Isoleringens inre
6,4mm (1/4") 8~10mm ≥10mm
9,5mm (3/8") 10~14mm ≥13mm
12,7mm (1/2") 14~16mm ≥13mm
15,9mm (5/8") 16~20mm ≥13mm
Om temperaturen överstiger 30°C och fuktigheten är över RH 80% måste isoleringen vara minst 20 mm tjock för att inte kondensvatten ska bildas på tätningens yta.

7.2 Anslutning av köldmedierören

7.2.1 Om anslutning av köldmediumrör

Före anslutning av köldmediumrör
Isoleringens tjocklek (t)
diameter (Øi)
Se till att utomhusenheten och inomhusenheten är monterade.
Typiskt arbetsflöde
Anslutning av köldmedierören innebär:
Anslutning av köldmedierör till inomhusenhetenAnslutning av köldmedierör till utomhusenhetenIsolera köldmedierörenBeakta riktlinjerna för:
- Rörbockning
- Flänsning av rörändar
- Användning av stoppventilerna

7.2.2 Försiktighetsåtgärder vid anslutning av köldmediumrör

INFORMATION
Läs även säkerhetsföreskrifterna och kraven i följande kapitel:
Allmänna försiktighetsåtgärderFörberedelser
Installatörens referenshandbok
33
7 | Installation av rör
FARA: RISK FÖR BRÄNNSKADA/SKÅLLNING
FÖRSIKTIGT
Använd kragkopplingsmuttern som är fäst på enheten.Sätt lite kylmaskinolja enbart på kragmutterns inre yta för att förhindra att gas
läcker ut. Använd kylmaskinolja för R32.
Återanvänd INTE kopplingar.
FÖRSIKTIGT
Använd INTE mineralolja på den flänsade delen.Installera ALDRIG en avfuktare för denna R32-enhet för att garantera dess
livslängd. Torkningsmaterialet kan lösas upp och skada systemet.
NOTERING
Vidta följande försiktighetsåtgärder för köldmediumrören:
Utöver det avsedda köldmediumet ska du undvika allt som skulle kunna blanda
sig in i köldmediumcykeln (t.ex. luft).
Använd endast R32 när du fyller på köldmedium.Använd endast installationsverktyg (t.ex. manometerställ) som är avsedda för
R32-installationer och som klarar trycket. Se även till att inte främmande föremål (som mineralolja och fukt) blandas in i systemet.
Installera rören så att flänsen INTE utsätts för mekanisk stress.Skydda rören enligt beskrivningen i tabellen nedan för att förhindra att fukt,
smuts eller damm kommer in i rören.
Var försiktig när du för in kopparrör genom väggar (se bilden nedan).

7.2.3 Riktlinjer vid anslutning av köldmediumrör

Installatörens referenshandbok
34
Enhet Installationsperiod Skyddsmetod
Utomhusenhet >1månad Knip ihop rören
<1månad Knip eller tejpa rören
Inomhusenhet Oavsett tidsperiod
INFORMATION
Öppna INTE köldmediets stoppventil innan du kontrollerar köldmedierören. När du behöver fylla på med ytterligare köldmedium rekommenderas det att du öppnar köldmediets stoppventil efter påfyllningen.
Håll dig till följande riktlinjer när du ansluter rören:
När kragmuttern ansluts ska flänsens insida smörjas med eter- eller esterolja. Dra
åt 3 eller 4 varv för hand innan du drar åt ordentligt.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
7 | Installation av rör
a
b
c
d
R=
0.4~0.8
±2
45°
90°
±2
ØA
a b
A
När du lossar en kragmutter ska du ALLTID använda 2 skiftnycklar tillsammans.När du ansluter rören ska du ALLTID använda en rörnyckel och en momentnyckel
tillsammans vid åtdragning av flänsmuttern. Det förhindrar sprickor i muttern och läckor.
a Momentnyckel
b Rörnyckel
c Rörkoppling
d Kragkopplingsmutter
Rördimensioner
(mm)
Ø6,4 15~17 8,7~9,1
Åtdragningsmome
nt (N•m)
Kragstorlek (A)
(mm)
Flänsform (mm)
Ø9,5 33~39 12,8~13,2
Ø12,7 50~60 16,2~16,6
Ø15,9 62~75 19,3~19,7

7.2.4 Riktlinjer för rörbockning

Använd en rörböjare. Alla rörböjar bör utföras så försiktigt som möjligt (böjradien ska vara 30~40 mm eller större).

7.2.5 Flänsning av röränden

1 Kapa änden av röret med en rörkapare. 2 Avlägsna grader med snittytan nedåt så att INGA spån kommer in i röret.
FÖRSIKTIGT
Ofullständig flänsning kan orsaka att köldmediegas läcker ut.Återanvänd INTE flänsar. Använd nya flänsar för att förhindra läckage av
köldmediegasen.
Använd endast de kragmuttrar som följer med enheten. Om du använder andra
kragmuttrar kan köldmediegas läcka ut.
a Kapa i exakt rät vinkel.
b Ta bort grader.
3 Lossa kragmuttern från stoppventilen och placera kragmuttern på röret. 4 Flänsa röret. Ställ i exakt den position som visas i följande bild.
Installatörens referenshandbok
35
7 | Installation av rör
a b
c
c
a
b
f
d
g
e
Flänsverktyg för R32
(kopplingstyp)
Kopplingstyp
A 0~0,5mm 1,0~1,5mm 1,5~2,0mm
5 Kontrollera att flänsningen är rätt utförd.
a Flänsens inre yta MÅSTE vara felfri.
b Rörets ände MÅSTE vara jämnt flänsad i en perfekt cirkel.
c Se till att kragmuttern är monterad.

7.2.6 Hur du ansluter köldmedierören till inomhusenheten

VARNING: NÅGOT LÄTTANTÄNDLIGT MATERIAL
Köldmediet i enheten är brandfarligt.
Rörlängd. Håll köldmediumrören så korta som möjligt.
Vanligt flänsverktyg
(Ridgid typ)
Vingmuttertyp
(Imperial typ)
1 Anslut köldmediumrör till enheten med kragkopplingar. 2 Isolera köldmediumrör, anslutningskablar och dräneringsslangen på
inomhusenheten enligt nedan:
a Gasrör
b Isolering gasrör
c Anslutningskabel
d Vätskerör
e Isolering vätskerör
f Tejp
g Dräneringsslang
NOTERING
Se till att isolera alla köldmediumrör. Alla frilagda rör kan orsaka kondens.
Installatörens referenshandbok
36
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

8 Elinstallation

I detta kapitel
8.1 Om att ansluta elledningarna................................................................................................................................................. 37
8.1.1 Försiktighetsåtgärder vid anslutning av elledningarna ......................................................................................... 37
8.1.2 Riktlinjer vid anslutning av elledningarna.............................................................................................................. 38
8.1.3 Specifikationer för standardkablar ........................................................................................................................ 39
8.2 Så här ansluter du elkablar till inomhusenheten................................................................................................................... 39

8.1 Om att ansluta elledningarna

Innan anslutning av elledningarna
Se till att:
Köldmedierören är anslutna och kontrolleradeVattenrör är anslutna
Typiskt arbetsflöde
8 | Elinstallation
Anslutning av elkablar består vanligtvis av följande steg:
1 Kontroll av att strömförsörjningen uppfyller enheternas elspecifikationer. 2 Anslutning av elkablar till utomhusenheten. 3 Anslutning av elkablar till inomhusenheten. 4 Anslutning av nätströmmen.

8.1.1 Försiktighetsåtgärder vid anslutning av elledningarna

FARA: RISK FÖR ELCHOCK
INFORMATION
Läs även säkerhetsföreskrifterna i kapitlet “Allmänna säkerhetsföreskrifter”.
INFORMATION
Läs även "8.1.3Specifikationer för standardkablar"[439].
VARNING
All kabeldragning FÅR ENDAST utföras av en auktoriserad elektriker och MÅSTE
följa gällande bestämmelser.
Gör alla elektriska anslutningar till den fasta kabeldragningen.Alla komponenter som anskaffats lokalt och alla elektriska konstruktioner SKALL
följa gällande bestämmelser.
Installatörens referenshandbok
37
8 | Elinstallation
b a
VARNING
Om strömmatningen saknar eller har fel N-fas kan utrustningen förstöras.Upprätta korrekt jordning. Jorda INTE enheten till en vattenledning, ett
vågfrontskydd eller en jordledning för telefon. Ofullständig jordning kan leda till elektriska stötar.
Installera nödvändiga säkringar eller kretsbrytare.Säkra elkablarna med buntband så att de INTE kommer i kontakt med vassa
kanter eller rör, särskilt på högtryckssidan.
Använd INTE skarvade kablar, fåtrådiga ledare, förlängningssladdar eller
fasfördelade anslutningar. De kan orsaka överhettning, elektrisk chock eller eldsvåda.
Installera INTE en fasförskjutande kondensator, eftersom enheten är försedd med
en inverter. En fasförskjutande kondensator försämrar prestandan och kan orsaka olyckor.
VARNING
Använd ALLTID flerkärniga kablar till strömförsörjningsledningar.
VARNING
Använd en huvudbrytare med minst 3 mm mellan kontaktpunkterna, vilken ger fullständig bortkoppling enligt villkoren i överspänningsklass III.
VARNING
Om strömsladden är skadad MÅSTE den bytas ut av tillverkaren, en serviceagent eller andra kvalificerade personer för att undvika faror.
VARNING
Anslut INTE strömsladden till inomhusenheten. Detta kan leda till elektriska stötar eller brand.
VARNING
Använd INGA lokalt införskaffade elkomponenter inuti produkten.Förgrena ALDRIG ström för dräneringspumpen eller något annat från
kopplingsplinten. Detta kan leda till elektriska stötar eller brand.
VARNING
Separera alltid anslutningsledningar från kopparrör utan värmeisolering eftersom dessa rör kan bli väldigt varma.

8.1.2 Riktlinjer vid anslutning av elledningarna

Tänk på följande:
Installatörens referenshandbok
38
Om fåtrådiga ledare används ska du installera en rund vågprofilerad kontakt i
trådens ände. Placera den runda vågprofilerade kontakten på kabeln t.o.m. den täckta delen och fäst kontakten med lämpligt verktyg.
a Fåtrådig ledare
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
b Rund vågprofilerad kontakt
c b
c
aa
A
AA´
c b ba c
a
B
B
1-3
d
c
b
a
Använd följande metod när du installerar kablar:
Kabeltyp Installationsmetod
Enkelledarkabel
a Lockig enkelledarkabel b Skruv c Platt bricka
Fåtrådig ledare med rund vågprofilerad kontakt
a Uttag
8 | Elinstallation
b Skruv c Platt bricka O Tillåtet X INTE tillåtet
Jordkabeln mellan kabelklämman och terminalen måste vara längre än de andra
kablarna.

8.1.3 Specifikationer för standardkablar

Komponent
Kabel mellan enheter (inomhus↔utomhus) 4-trådig kabel 1,5mm²~2,5mm²

8.2 Så här ansluter du elkablar till inomhusenheten

och lämplig för 220~240V
H05RN-F (60245 IEC 57)
Genomför elektriska installationer i enlighet med installationshandboken samt nationella bestämmelser och vedertagna arbetssätt.
1 Placera inomhusenheten på monteringsplåtens krokar. Använd " "-
markeringarna som guide.
a Monteringsplåt (tillbehör)
b Del av förpackningsmaterialet
Installatörens referenshandbok
39
8 | Elinstallation
a
b
c
c Anslutningskabel
d Kabelledare
INFORMATION
Stöd enheten med en del av förpackningsmaterialet.
2 Öppna frontpanelen och sedan serviceluckan. Se "6.2 Öppna
inomhusenheten"[424].
3 För anslutningskablarna från utomhusenheten genom hålet i väggen och
sedan genom baksidan av inomhusenheten och till framsidan.
Obs: Om anslutningskabeln redan är skalad lindar du ändarna med isoleringstejp.
4 Böj upp kabeländen.
NOTERING
Var noga med att hålla isär ledningarna för spänningsförsörjning och
signalöverföring. Signalöverföringskablar och strömförsörjningskablar får korsas, men ALDRIG dras parallellt.
För att undvika elektriska störningar ska avståndet mellan de två kablarna ALLTID
vara minst 50mm.
VARNING
Vidta nödvändiga åtgärder för att förebygga att smådjur söker skydd i enheten. Smådjur som kommer i kontakt med strömförande delar kan orsaka fel, rökutveckling eller eldsvåda.
a Kopplingsplint
b Elkomponentplint
c Kabelklämma
5 Skala kabeländarna cirka 15mm. 6 Koppla samman de färgade kablarna med motsvarande siffror på
inomhusenhetens kopplingsplint och skruva fast kablarna ordentligt.
Installatörens referenshandbok
40
7 Anslut jordledningen till motsvarande terminal. 8 Fäst kablarna ordentligt med skruvarna på kopplingsplinten. 9 Dra i kablarna för att kontrollera att de sitter ordentligt fast och fäst sedan
kablarna med kabelklämman.
10 Forma kablarna så att serviceluckan går att stänga ordentligt och stäng sedan
luckan.
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
8 | Elinstallation
Installatörens referenshandbok
41
9 | Avsluta installationen av inomhusenheten
d
e
c
bfa
a b
c c d e

9 Avsluta installationen av inomhusenheten

9.1 Så här isolerar du dräneringsrör, köldmediumrör och anslutningskabel

1 När du är färdig med installation av dräneringsrör, köldmediumrör och
anslutningskabel. Linda samman köldmediumrör, anslutningskablar och dräneringsslangen med isoleringstejp. Överlappa minst halva tejpens bredd varje varv.
a Dräneringsslang b Anslutningskabel c Monteringsplåt (tillbehör) d Köldmediumrör e Fästskruvar för inomhusenheten M4×12L(tillbehör)
f Bottenram

9.2 Så här för du rören genom hålet i väggen

1 Anpassa köldmediumrör efter rörmarkeringarna på monteringsplåten.
a Dräneringsslang b Täta detta hål med kitt eller annat tätningsmaterial c Vinyltejp d Isoleringstejp e Monteringsplåt (tillbehör)
NOTERING
Böj INTE köldmediumrör.Tryck INTE på köldmediumrör på bottenramen eller frontgallret.
Installatörens referenshandbok
42
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
9 | Avsluta installationen av inomhusenheten
2 För dräneringsslangen och köldmediumrör genom vägghålet.

9.3 Så här fixerar du enheten på monteringsplåten

1 Placera inomhusenheten på monteringsplåtens krokar. Använd " "-
markeringarna som guide.
2 Tryck på inomhusenhetens bottenram med båda händerna för att fästa den
på monteringsplåtens krokar. Kontrollera att INGA kablar kläms någonstans.
Obs: Kontrollera att anslutningskablarna INTE kläms av inomhusenheten.
3 Tryck på inomhusenhetens bottenpanel med båda händerna tills den sitter
ordentligt fast på monteringsplåtens krokar.
4 Fäst inomhusenheten på monteringsplåten med 2 fästskruvar för
inomhusenheten, M4×12L (tillbehör).

9.4 Hur du stänger inomhusenheten

9.4.1 Så här sätter du tillbaka frontgallret

1 Installera frontgallret och se till att de 3 övre krokarna fäster ordentligt. 2 Sätt tillbaka 2 skruvar (klass 15~42) eller 3 skruvar (Klass 50~71) på
frontgallret.
3 För klass 50~71 återinstallera den lägre klaffen (vågrätt blad). Anslut de 2
centrumanslutningspunkterna. Kroka på bladets högra sida på axeln. Kroka på bladets vänstra sida.
4 Installera luftfiltret, montera frontpanelen och stäng den.

9.4.2 Så här stänger du serviceluckan

1 Sätt tillbaka serviceluckan på den ursprungliga platsen på enheten. 2 Sätt tillbaka 1 skruv på serviceluckan.
NOTERING
Var noga med att dra fast serviceluckan med åtdragningsmoment som INTE överstiger 1,4(±0,2)N•m.

9.4.3 Så här sätter du tillbaka frontpanelen

1 Sätt tillbaka frontpanelen. Justera axlarna med spåren tryck sedan in dem helt. 2 Stäng frontpanelen långsamt. Tryck på båda sidorna och mitten.
Installatörens referenshandbok
43
9 | Avsluta installationen av inomhusenheten
Installatörens referenshandbok
44
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

10 Konfiguration

a
ON/ OFF
b
a

10.1 Så här anger du en annan adress

Om 2 inomhusenheter installerats i 1 rum kan olika adresser anges för de 2 fjärrkontrollerna.
1 Ta bort luckan och ta ur batterierna ur fjärrkontrollen. 2 Klipp adressbygeln J4.
10 | Konfiguration
a Adressbygel J4
NOTERING
Var noga med att INTE skada några kringliggande komponenter när du klipper adressbygeln.
3 Sätt på strömmen.
4 Tryck samtidigt på och . 5 Tryck på , välj och tryck på .
Resultat: Driftlampan börjar blinka.
a Driftlampa
b Inomhusenhetens ON/OFF-brytare
6 Tryck på inomhusenhetens ON/OFF-brytare medan driftlampan blinkar.
Adressbygel Adress
Fabriksinställning 1
Efter klippning med avbitartång 2
Installatörens referenshandbok
45
10 | Konfiguration
INFORMATION
Om inställningen INTE kunde slutföras medan driftlampan blinkade gör du om proceduren från första steget.
7 När inställningen är klar trycker du på i minst 5sekunder.
Resultat: Fjärrkontrollen återgår till föregående skärm.
Installatörens referenshandbok
46
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

11 Driftsättning

11.1 Översikt: driftsättning

Typiskt arbetsflöde
Driftsättningen består vanligtvis av följande moment:
1 Kontrollera "Checklistan före driftsättning". 2 Utföra en testkörning av systemet.

11.2 Checklista före driftsättning

Efter installation av enheten ska följande punkter först kontrolleras. När alla kontroller är gjorda ska enheten stängas. Strömsätt enheten när den har stängts.
Läs de kompletta installationsinstruktionerna som beskrivs i Installatörens referensguide.
Inomhusenheterna är korrekt monterad.
11 | Driftsättning
Utomhusenheten är korrekt monterad.
Luftintag/luftutsläpp
Kontrollera att enhetens luftintag och luftutsläpp INTE är blockerade av pappersark, papp eller andra material.
Det finns INGA saknade faser eller motfaser.
Köldmedierören (gas och vätska) är värmeisolerade.
Dränering
Kontrollera att dräneringen flödar som den ska. Trolig konsekvens: Kondensvatten kan droppa ned.
Systemet har jordats korrekt och alla jordkontakter är ordentligt åtdragna.
Säkringarna eller lokalt installerade skyddsanordningar är installerade i enlighet med detta dokument och har INTE förbikopplats.
Matningsspänningen stämmer överens med spänningen på enhetens märkskylt.
De angivna ledningarna används för inkopplingskabeln.
Inomhusenheten får signaler från fjärrkontrollen.
Det finns INGA lösa anslutningar eller skadade elektriska komponenter i kopplingsboxen.
Kompressorns isoleringsresistans är OK.
Det finns INGA skadade komponenter eller klämda rör inne i inomhus- och utomhusenheterna.
Det finns INGA köldmedieläckor.
Korrekta rörstorlekar har installerats och rören är ordentligt isolerade.
Stoppventilerna (gas och vätska) på utomhusenheten är helt öppna.
Installatörens referenshandbok
47
11 | Driftsättning

11.3 Utföra en testkörning

11.3.1 Så här gör du en testkörning med fjärrkontrollen

Nödvändigt: Strömförsörjningen MÅSTE ha angivna specifikationer. Nödvändigt: Testkörning kan köras i kylnings- eller uppvärmningsläge. Nödvändigt: Testerna bör genomföras enligt användarhandboken för
inomhusenheten för att kontrollera att alla funktioner och komponenter fungerar som de ska.
1 I kylningsläge väljer du lägsta programmerbara temperatur. I
uppvärmningsläge väljer du högsta programmerbara temperatur. Testkörningen kan inaktiveras vid behov.
2 När testkörningen är slutför ställer du in temperaturen på normal nivå. I
kylningsläge: 26~28°C, i uppvärmningsläge: 20~24°C.
3 Systemet slutar köras 3minuter efter att enheten har stängts AV.
1 Tryck på för att starta systemet.
2 Tryck samtidigt på och . 3 Tryck på , välj och tryck på .
Resultat: Testkörningsläget stannar automatiskt efter cirka 30minuter.
4 Du kan stoppa driften tidigare genom att trycka på .
Installatörens referenshandbok
48
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

12 Överlämna till användaren

När testkörningen är klar och enheten fungerar korrekt ska du se till att användaren förstår:
Se till att användaren har den tryckta dokumentationen, samt be honom/henne
att förvara dem för framtida referensbruk. Informera användaren om att fullständig dokumentation finns på den URL som tidigare beskrivits i manualen.
Förklara för användaren hur systemet används och vad han/hon ska göra om det
uppstår något problem.
Visa användaren vilka underhållsarbeten som ska utföras på enheten.
12 | Överlämna till användaren
Installatörens referenshandbok
49
13 | Kassering

13 Kassering

NOTERING
Försök INTE att demontera systemet själv: nedmontering av systemet, hantering av köldmedium, olja och andra delar SKA ske i enlighet med gällande lagstiftning. Enheter MÅSTE behandlas på en specialiserad behandlingsanläggning för återvinning.
Installatörens referenshandbok
50
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06

14 Tekniska data

,
A
INDOOR
OUTDOOR
Delar av de senaste tekniska data är tillgängliga på den regionala Daikin-
webbplatsen (allmänt tillgänglig).
Alla de senaste tekniska data finns på Daikin Business Portal (inloggning krävs).

14.1 Kopplingsschema

14.1.1 Enhetsförklaring till kopplingschema

Information om använda komponenter och numrering finns i enhetens kopplingsschema. Komponenter numreras med siffror i stigande ordning för varje komponent och representeras i översikten nedan med "*" i komponentkoden.
Symbol Funktion Symbol Funktion
Strömbrytare Skyddsjord
14 | Tekniska data
Anslutning Skyddsjord (skruv)
Kontaktdon
Likriktare
Jord Reläkontakt
Lokal kabeldragning Kortslutningskontakt
Säkring Terminal
Inomhusenhet Kopplingslist
Utomhusenhet Kabelklämma
Överspänningsskydd
Symbol Färg Symbol Färg
BLK Svart ORG Orange
BLU Blå PNK Rosa
BRN Brun PRP, PPL Lila
GRN Grön RED Röd
GRY Grå WHT Vit
YLW Gul
Symbol Funktion
A*P Tryckt kretskort
BS* Tryckknapp PÅ/AV, driftbrytare
BZ, H*O Summer
C* Kondensator
Installatörens referenshandbok
51
14 | Tekniska data
Symbol Funktion
AC*, CN*, E*, HA*, HE*, HL*, HN*, HR*,
Kontakt, kontaktdon MR*_A, MR*_B, S*, U, V, W, X*A, K*R_*, NE
D*, V*D Diod
DB* Diodbrygga
DS* DIP-switch
E*H Värmare
FU*, F*U, (för egenskaper, se
Säkring kretskortet i din enhet)
FG* Kontakt (ramjord)
H* Kabelsele
H*P, LED*, V*L Pilotlampa, lysdiod
HAP Lysdiod (servicemonitor grön)
HIGH VOLTAGE Högspänning
IES Intelligent eye-sensor
IPM* Intelligent kraftmodul
K*R, KCR, KFR, KHuR, K*M Magnetrelä
L Spänning
L* Spole
L*R Reaktor
M* Stegmotor
M*C Kompressormotor
M*F Fläktmotor
M*P Dräneringspumpmotor
M*S Svängningsmotor
MR*, MRCW*, MRM*, MRN* Magnetrelä
N Neutral
n=*, N=* Antal varv genom ferritkärna
PAM Pulsamplitudmodulering
PCB* Tryckt kretskort
PM* Kraftmodul
PS Huvudströmbrytare
PTC* PTC-termistor
Installatörens referenshandbok
52
Q* Isolerad bipolär gate-transistor (IGBT )
Q*C Strömbrytare
Q*DI, KLM Jordfelsbrytare
Q*L Överspänningsskydd
Q*M Termobrytare
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
14 | Tekniska data
Symbol Funktion
Q*R Överspänningsskydd
R* Motstånd
R*T Termistor
RC Mottagare
S*C Begränsningsbrytare
S*L Flottörbrytare
S*NG Köldmediumläckagedetektor
S*NPH Trycksensor (hög)
S*NPL Trycksensor (låg)
S*PH, HPS* Tryckbrytare (hög)
S*PL Tryckbrytare (låg)
S*T Termostat
S*RH Luftfuktighetssensor
S*W, SW* Driftbrytare
SA*, F1S Överspänningsavledare
SR*, WLU Signalmottagare
SS* Väljare
SHEET METAL Fixerad kopplingslistplåt
T*R Transformator
TC, TRC Sändare
V*, R*V Varistor
V*R Diodbrygga, isolerad bipolär gate-
transistor (IGBT) effektmodul
WRC Trådlös fjärrkontroll
X* Terminal
X*M Kopplingslist (block)
Y*E Elektronisk expansionsventilspole
Y*R, Y*S Reverseringssolenoidventil
Z*C Ferritkärna
ZF, Z*F Brusfilter
Installatörens referenshandbok
53
15 | Ordlista

15 Ordlista

Återförsäljare
Återförsäljare av produkten.
Behörig installatör
Tekniskt kunnig person som är behörig för att installera produkten.
Användare
Person som äger och/eller använder produkten.
Gällande lagstiftning
Alla internationella, europeiska, nationella och lokala direktiv, lagar, förordningar och/eller koder som är relevanta och gäller för en särskild produkt eller domän.
Serviceföretag
Behörigt företag som kan utföra eller samordna nödvändig service på enheten.
Installationshandbok
Installationshandbok för en särskild produkt eller applikation, förklarar hur du installerar, konfigurerar och underhåller den.
Bruksanvisning
Bruksanvisning för en specifik produkt eller applikation som beskriver hur man använder produkten.
Underhållsanvisningar
Bruksanvisning för en specifik produkt eller applikation som beskriver (om det är relevant) hur produkten eller applikationen installeras, konfigureras, används och/eller underhålls.
Tillbehör
Etiketter, handböcker, informationsblad och utrustning som levereras med produkten och som ska installeras i enlighet med instruktionerna i den medföljande dokumentationen.
Extrautrustning
Utrustning som tillverkats eller godkänts av Daikin kan kombineras med produkten i enlighet med instruktionerna i den medföljande dokumentationen.
Anskaffas lokalt
Utrustning som INTE tillverkats Daikin men som kan kombineras med produkten i enlighet med instruktionerna i den medföljande dokumentationen.
Installatörens referenshandbok
54
Daikin luftkonditioneringsanläggning
ATXM50R2V1B
4P518023-8G – 2020.06
DAIKIN ISITMA VE SOĞUTMA SİSTEMLERİ SAN.TİC. A.Ş.
İSTANBUL / TÜRKİYE Tel: 0216 453 27 00 Faks: 0216 671 06 00 Çağrı Merkezi: 444 999 0 Web: www.daikin.com.tr
G
ülsuyu Mahallesi, Fevzi Çakmak Caddesi, Burçak Sokak, No:20, 34848 Maltepe
Copyright 2020 Daikin
Verantwortung für Energie und Umwelt
4P518023-8G 2020.06
Loading...