Daikin 2MXS40G2V1B, 2MKS40G2V1B, 2MXS50G2V1B, 2MKS50G2V1B, 2MXS40H2V1B Installation manuals

...
INSTALLATION MANUAL
R410A Split Series
Models 2MXS40G2V1B 2MKS40G2V1B 2MXS40H2V1B 2MKS40H2V1B 2MXS40H3V1B 2MKS50G2V1B 2MXS50G2V1B 2MKS50H2V1B 2MXS50H2V1B 2MXS50H3V1B 2AMX40F2V1B 2AMX40G2V1B
Installation manual
R410A Split series
Installationsanleitung
Split-Baureihe R410A
Manuel d’installation
Série split R410A
Montagehandleiding
R410A Split-systeem
Manual de instalación
Serie Split R410A
Manuale d’installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Série split R410A
English
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой
Montaj kýlavuzlarý
R410A Split serisi
Рóссêий
Türkçe
DAIKIN.TCF.015 M1/07-2008
KEMA Quality B.V.
74736-KRQ/EMC97-4957
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
*
Low Voltage 2006/95/EC
Electromagnetic Compatibility 2004/108/EC
Noboru Murata
Manager Quality Control Department
1st of Nov. 2008
DAIKIN INDUSTRIES, LTD.
2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B
2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B
3SB64417-5A
DAIKIN.TCF.015 P6/07-2012
DEKRA Certification B.V. (NB0344)
74736-KRQ/EMC97-4957
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Machinery 2006/42/EC **
Low Voltage 2006/95/EC
Electromagnetic Compatibility 2004/108/EC *
Shinri Sada
Manager Quality Control Department
, ,
DAIKIN INDUSTRIES, LTD.
2MXS40H3V1B, 2MXS50H3V1B, 2AMX40G3V1B, 2AMX50G3V1B
EN60335-2-40,
3SB65451-10D

Safety Precautions

• The precautions described herein are classified as WARNING and CAUTION. They both contain important informa­tion regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING .... Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .....Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal con­nections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pres­sure in the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Imperfect earthing may result in electric shocks.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
Toxic gas may be produced if the refrigerant gas leaks
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insu­late piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
1 English

Accessories

Accessories supplied with the outdoor unit:
A B
Installation Manual
Refrigerant charge label
1
There is on the bottom packing case.
C D
Drain plug (heat pump models)
1
There is on the bottom packing case.
E
Screw bag (for fixing the wire retainer)
1
There is on the bottom packing case.
There is on the bottom packing case.
Multilingual fluorinated greenhouse gases label
There is on the bottom packing case.
F
Reducer assembly (only 50 class)
There is on the bottom packing case.
1
1
1

Precautions for Selecting the Location

1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise, will not cause a nuisance to the neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place. Locate the unit so that the noise and the discharged hot air will not annoy the neighbors.
7) Install units, power cords and inter-unit wires at least 3m away from television and radio sets. This is to prevent interfer­ence to images and sounds. (Noises may be heard even if they are more than 3m away depending on radio wave con­ditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air condi­tioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE:
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient temper­ature, be sure to follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its suc­tion side facing the wall.
• Never install the outdoor unit at a site where the suction side may be exposed directly to wind.
• To prevent exposure to wind, it is recommended to install a baffle plate on the air discharge side of the outdoor unit.
• In heavy snowfall areas, select an installation site where the snow will not affect the unit.
Construct a large canopy. Construct a pedestal.
Install the unit high enough off the ground to prevent burying in snow.