-20-
Hardware Troubleshooting : SMPS
2) FEL-4247UL : DLA-42C7LABD
'CHECKING FLOW ABOUT INFERIOR SMPS' (MODEL NAME : FEL-4247UL)
PAGE : 1/2
1. Stand-by 5V is working out.
A. Can you check In-put voltage(DC) of the capacitor(Location No. : C23)?
YES
YES 1.1 Checking open and short of Out-put side wire cable.
NO
1.2. Checking open and short of the around parts that was connected IC3(STR-A6252).
(Location No. : R4, R5, D4, D5, D7)
1.3. Checking open and short of IC3's each pins.
1.4. Checking open and short of 5V's Out-put diode.
(Location No. : D13)
NO
1.5. Can you check the Fuse(F1) condition(open and short)?
YES : Checking 1.2 item after changing FUSE. NO : Checking 1.6 item.
1.6. Checking open and short of BD1, BD2.
YES : Changing BD1, BD2.
NO : Checking open and short of Z1,LF1,LF2 ,C1,C2
A. Can you check that Vcc voltage of IC3 was supplied from DC15V to DC27V?
YES
NO
2.1. Can you check the IC9's condition(open and short)?
YES : Changing IC9. NO : Checking 2.2 item.
2.2. Can check the voltage(AC 400V) of AC rectifying side C23?
YES : Checking 2.5 item.
NO : Checking 2.5 item after checking the conditions(open and short) of the around parts that was
connected IC1. (Location No. :R14,R51,Q1,Q5,D1,D23,D12, IC1)
YES 2.3. changing Q4.
NO
B. Can you check the Q4's condition(open and short)?
C. Can you check that Vcc voltage of IC2's No.12pin was supplied from DC10V to DC12V?
NO
2.4. Can you see the square wave(400mV, 40kH) of Q2's source side when DC 13V was supplied to
IC2's No.12pin from DC POWER SUPPLY?
(CAUTION : Test do it after AC Power Off)
YES : Checking 2.1 item after checking diode's condition(open and short) of MainOut-put side.
(Location No. :D14,D15,D16,D17,D18)
NO : Checking open and short of the around parts that was connected IC2.
(Location No. :Q2,Q3,D9,D10,D19,D20,F2)
YES 2.5. Checking open and short of MAIN BOARD.
2.6. Checking open and short of MAIN BOARD.
2. MAIN Out-put voltage is working out but Stand-by 5V is working.
A. Can you check that it is working normal at Power On after dischanging for 1 minute from Power Off?
YES : It's protection due to out-put short of the moment through worker's carelessness.
NO : Checking 2.1 item.
A. Is Power On signal(3.3V) supplied to Base of Q4?