Dacor RNHP3018S Installation manual

Installation Instructions
Renaissance® Wall Mount Range Hoods
Models RNHP30, RNHP36, and RNHP48
Part No. 109172 Rev. A
APPROVED FOR USE WITH ALL DACOR® RANGES AND COOKTOPS.
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD FOR FANS AND VENTILATORS.
Table of Contents
Important Safety Instructions .......................................... 1
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
Product Specifications .................................................... 3
General Specifications ..................................................... 3
Weight Specifications ....................................................... 3
Dimensions ...................................................................... 4
Preparation and Setup ...................................................... 6
Parts List .......................................................................... 6
Necessary Tools and Hardware ....................................... 6
Meeting Electrical Codes ................................................. 7
Installing the Electrical Source ......................................... 7
Meeting Installation Requirements ................................... 8
Planning the Ductwork ..................................................... 9
Preparing the Mounting Location ....................................11
Installation Instructions .................................................. 12
Marking the Centerlines ................................................ 12
Installing the Holding Brackets ....................................... 13
Rotating the Blower(s) for Rear Exhaust ....................... 14
Assembling the Filters .................................................... 18
Using the Dual to Single Transition Kit# AHT10 ............ 19
Hanging the Range Hood .............................................. 21
Hardwiring the Hood ...................................................... 22
Verifying the Setup ......................................................... 24
The Installation Checklist ............................................... 25
Wiring Diagrams .............................................................. 26
Before You Begin...
Important:
Installer: In the interest of safety and to minimize problems, read these Installation Instructions completely and
carefully before you begin the installation process. Leave these installation instructions with the consumer.
Write the Data Plate Information in the Use and Care Manual before installing the unit.
Customer: Keep these Installation Instructions for future reference and the local electrical inspector’s use.
If You Need Help...
If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under war­ranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready. The model and serial number are printed on the appliance data plate.
Dacor Customer Service Team
Phone: (800) 793-0093 ex. 2813 (U.S.A. and Canada) Monday — Friday 6:00
Web site: www.dacor.com
Dacor Distinctive Service (for repairs under warranty only)
Phone: (800) 793-0093 ex. 2822 (U.S.A. and Canada) Monday — Friday 6:00
a.m. to 5:00 p.m. Pacific Time
a.m. to 5:00 p.m. Pacific Time
Appliance Data Plate
The appliance data plate is a label that:
has the model and serial number information and electrical requirements.
is located inside the hood, above the filters on the back wall of the chassis. Remove the filters to view it.
All specifications subject to change without notice. Dacor assumes no liability for changes to specifications.
© 2008 Dacor, all rights reserved.

Important Safety Instructions

Important Information About Safety Instructions

The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper­ating this or any other appliance.
Always contact the Dacor Customer Service Team about problems and conditions that you don’t under­stand.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that MIGHT result in minor personal injury or property damage.
DANGER
To avoid the possibility of explosion or fire, do not store or use combustible, flammable or explosive vapors and liquids (such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans away from cooktop burners, ovens and range hoods. Do not store flammable or explosive materials in adjacent cabinets or areas.
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means
to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue(chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
READ AND SAVE THESE INSTRUCTIONS
1
Important Safety Instructions
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

General Safety Precautions

To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following:
WARNING
• Do not install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
• This range hood must be installed and grounded by a qualified installer according to these installation instructions.
• Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service, or maintenance can cause serious personal injury or property damage.
• The user should not install, repair, or replace any part of the range hood unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor authorized service representative at (800) 793-0093, or at www.dacor.com for examination, repair or adjustment.
• Keep all packaging materials away from children. Plastic bags can cause suffocation.
• Do not use an extension cord or adapter plug with this appliance.
• The installer must show the user the fuse box or circuit breaker panel box and how to turn the power on/off.
• Before installing or servicing the range hood, switch the power OFF at the fuse box circuit breaker and lock the elec­trical panel door to prevent power from being switched on accidentally. When the electrical panel cannot be locked, securely fasten a prominent warning device, such as a tag, to the electrical panel.
• Read the Use and Care Manual completely before using the appliance. Clean the appliance only as instructed in the Use and Care Manual. Use only the cleaners specified.
• Do not tamper with the controls.
• Never allow the filters to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the hood.
• Clean the filters, channels, and all grease-laden surfaces often to prevent grease fires and to maintain performance.
• If the cooktop and range hood are near a window, use an appropriate window treatment; Avoid long drapes or win­dow coverings that could blow over the cooktop and hood and create a fire hazard.
• Always run the blower(s) whenever the cooktop is operating.
• Never leave the range or cooktop unattended when a burner (or element) is in use. Boil-overs and greasy spills may smoke and/or ignite.
• Do not leave children alone or unattended in the area where the cooktop and range hood are in use. Never allow children to sit or stand on an appliance. Do not let children play with a range, cooktop, or range hood. Do not store items of interest to children above or around the cooktop, range, or range hood.
• The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less than 30” (76.2 cm). The vertical distance may be longer for the range or cooktop being used. Consult the range or cooktop Installation Instructions for the minimum and maximum vertical distance from the appliance being used.
• TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
• PROLONGED POWER FAILURE Do not attempt to use this appliance during a continuous power failure.
2

Product Specifications

General Specifications

All Models
Features Description
Blower
Speeds
Filters Baffle style, dishwasher safe
Exhaust(s) 8-inch duct diameter
Total Connect
Load
Lights
Individual Models
Model
Number
Lights 4 3 2
Filters 4 3 2
Blowers 2 1 1
Exhaust
Vents
Blower
Rating
Four (4)
120V, 60 Hz, 9 Amp. Max. (10.0 Amp Max. surge)
Dimmable LED: PAR16 E26/27 120V, 7.5W (75W Max. other bulbs)
RNHP48 RNHP36 RNHP30
2 1 1
1200 CFM 600 CFM 600 CFM

Weight Specifications

Individual Models
Model Weight
RNHP3012 51 lbs. (23 kg)
RNHP3018 RNHP3612
RNHP3618 57 lbs. (26 kg)
RNHP4812 70 lbs. (32 kg)
RNHP4818 77 lbs. (35 kg)
Individual Models
Model
Number
RNHP3012 x x x
RNHP3018 x x x
RNHP3612 x x x
RNHP3618 x x x
RNHP4812 x x x
Top Vent Rear Vent
53 lbs. (24 kg)
Rotatable
Fan
RNHP4818 x x x
3
Product Specifications

Dimensions

Electrical and Ductwork Connections
Connect electrical wires and ductwork through the top or rear of the hood. Before installing the hood, mark the access holes according to the diagrams below.
Top Connections: Electrical and Duct Dimensions
Single Exhaust Models**
Electrical access holes
7/8 in dia. (5.1 cm)
A
B
See Top Access Holes table on right page.
Rear Connections: Electrical and Duct Dimensions
Standard 8-inch duct
C
C
L
9 7/8 in
(25.1 cm)
19 3/4 in
(50.2 cm)
Dual Exhaust Models*
Standard 8-inch duct
Tolerances: +1/16” -0”, unless otherwise stated.
Back of
hood
5 3/4 in
(14.61 cm)
See Rear Access Holes table on right page.
B
A
Electrical access holes
7/8 in (5.1 cm) (diameter)
Bottom of
hood
4
C
Dual Exhaust Models*
Standard 8-inch duct
19 3/4 in
(50.2 cm)
9 7/8 in
(25.1 cm)
C
L
Single Exhaust Models**
Standard 8-inch duct
5 3/4”
(14.61 cm)
Models RNHP48
*
Models RNHP36 &
**
RNHP30
Product Specifications
Dimensions
Single Blower: RNHP30 & RNHP36 Series
D
A
C
B
Tolerances: +1/16” -0” unless otherwise stated.
Dual Blower: Model RNHP48 Series
D
A
C
B
Hood Dimensions
Model A B C D
RNHP3012 29 7/8” (75.9 cm)
RNHP3612 35 7/8” (91.1 cm)
RNHP4812 47 7/8” (121.6 cm)
RNHP3018 29 7/8” (75.9 cm)
RNHP3618 35 7/8” (91.1 cm)
RNHP4818 47 7/8” (121.6 cm)
24”
(61 cm)
24”
(61 cm)
12”
(30.48 cm)
18”
(45.7 cm)
(30.2 cm)
(30.2 cm)
Page 4: Electical Access Dimensions
Top Access Holes A B C
RNHP48 RNHP36 RNHP30
1 1/2” (3.81 cm) 5” (12.7 cm) 3” (7.62 cm)
1 1/2” (3.81 cm) 4 1/2” (11.43 cm) 3” (7.62 cm)
1 1/2” (3.81 cm) 5 1/2” (13.97 cm) 3” (7.62 cm)
Rear Access Holes A B C
RNHP48 RNHP36 RNHP30
1” (2.54 cm) 5” (12.7 cm) 3” (7.62 cm)
1” (2.54 cm) 4 1/2” (11.43 cm) 3” (7.62 cm)
1” (2.54 cm) 5 1/2” (13.97 cm) 3” (7.62 cm)
11 7/8”
11 7/8”
5
Preparation and Setup
Parts List
Hood (1)
A
Grease channel (1)
B
Baffle-style filter with knobs
C
(ready-to-assemble kit) (2-4)
D
Holding brackets and hardware (2)
E
Dimmable LED light bulbs (2-4)
F
Light replacement tool (1)
G
Literature (2)
Dacor Cleaning Creme (1)
I
E
Hood
Model
LED Lights 4 3 2
Bafle-Style
Filters
RNHP48 RNHP36 RNHP30
4 3 2
pictures vary by model
A
C
D
F
G
B
I

Necessary Tools and Hardware

Please make sure these tools and hardware are within reach before beginning the installation.
Hood Installation
Phillips screwdriver Drill + bits Jigsaw
Flathead screwdriver
Pencil or marking tool
Wire connector caps Level
Wire stripper Junction box
Tape measure 8” Ducting
Stud finder Foil tape
Sheet metal screws
STAINLESS
STEEL
CLEANER
Blower Rotation (optional)
Phillips screwdriver 5/16” Nut driver
Dual to Single Vent
Transition Kit (optional accessory)
Dacor Kit #AHT10 Drill Foil tape
10” Ducts and
ducting materials
Sheet metal
screws
6
Preparation and Setup

Meeting Electrical Codes

Installing the Electrical Source

WARNING
Make sure electrical service to the range hood is installed by a licensed electrician.
It is the owner’s responsibility to confirm that all electrical requirements are met by a qualified electrician who is is servicing this appliance.
The electrical installation, including the minimum supply­wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA* (or latest revision), local codes, and ordinances.
*A copy of this standard can be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
The ground terminal on the hood must be connected to a grounded, metallic, permanent wiring system, or a grounding conductor installed by a licensed electrician.
Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral (white) power supply wire.
Do not install a fuse in the neutral or ground circuit.
Connect the hood directly to an electrical junction box. Hard-wire the hood according to local code direct-
ly to a dedicated three-wire grounded, single phase circuit rated at 120 Vac 60 Hz, 15 Amp.
See the diagram below: Top or Rear Electrical Access Holes for wire hole locations inside the hood.
See Wiring Diagrams at the end of this document.
Install an electrical junction box near the hood’s electrical access holes according to local codes.
See image below: Suggested Area of Junction Box.
1. Drill 7/8” holes in the wall or cabinet (as needed) to act as a passageway for the electrical wiring.
2. See the last pages of this Installation Guide for wire diagrams.
Junction Box Area
Top Access
Rear Access
Top or Rear Electrical Access Holes
Hood
Suggested Area of Junction Box
7
E
30” min.*
(76.2 cm)
Electrical
access
* From cooking surface
top
rear
E
Preparation and Setup

Meeting Installation Requirements

WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Use only ductwork deemed acceptable by state, municipal and local codes.
WARNING
To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the range should be avoided.
IMPORTANT
See the diagram for minimum installed distance from the hood to the cooktop surface. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.
The hood must be as wide as the cooktop surface or wider.
Plan the installation so that all minimum dimensions are met or exceeded.
Dimensions given are minimum clearances, unless oth­erwise noted.
All contact surfaces between the hood and any cabine­try or walls must be sturdy, solid, and at right angles.
Install the hood and cooking appliance(s) so that they can be removed if service is required.
Cabinet Layout Dimensions
Minimum Width of E:
Upper Cabinet Cutout & Appliance Width
Models E
RNHP3012, RNHP3018 30 inches (76.2 cm)
RNHP3612, RNHP3618 36 inches (91.5 cm)
RNHP4812, RNHP4818 48 inches (121.9 cm)
All tolerances: +1/16” -0”, unless otherwise stated.
8
Preparation and Setup

Planning the Ductwork

WARNING
• To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely.
• Range hoods may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heat­ers, and fireplaces. To avoid drawing lethal gases into the home, follow the manufacturer’s recommendation for these devices and consult NFPA and ASHRAE rec­ommendations.
• Failure to install a remote blower or proper ductwork may result in a backdraft and/or insufficient venting of smoke and fumes.
DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small dif­ferences between blower air flow rates can greatly reduce the air draw by the hood.
CAUTION
To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
WARNING
During duct installation, make sure there are no obstructions that keep the damper flaps on the top of the hood from opening.
Local building codes may require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate (CFM). The specified rate varies based on locale. Consult a qualified HVAC specialist when designing the system for the require­ments in your area and to assure optimal performance.
All ductwork materials (including screws and foil tape) must be purchased separately by the customer.
Make sure ductwork does not interfere with floor joists or wall studs.
On dual exhaust models, the two 8-inch exhausts may be merged into one 10-inch duct using Dacor transition kit AHT10. See page 19 for details.
Fasten all joints with sheet metal screws and seal with certified duct tape or foil tape.
A B
Vent Direction Options
The blower direction is through top A of the hood. However, the blower can be rotated to vent through the rear B of the hood.
When planning new ductwork, always find the shortest, most direct route to the outside.
Duct Length Calculation Table
The maximum straight duct length for the hood is deter­mined by the type of duct used. See the chart below.
Duct Size Maximum Duct Run
8-inch Round 60 feet
10-inch Round 50 feet
3 1/4-in x 10-in Rectangular 50 feet
For each elbow and transition added, “equivalent lengths” must be subtracted from your total maximum duct run length to compensate for wind resistance.
To determine your maximum length:
1. Start with the total max. length of your duct run, then
2. Subtract all of the ductwork equivalent lengths (see chart below).
Ductwork Equivalent Lengths
Piece Subtract Piece Subtract
8-inch
90° Elbow
8-inch
45° Elbow
3-in x 10-inch to Round 90°
Transition
Roof Cap *
* The equivalent lengths of roof and wall caps vary with model and configuration.
7 feet 10-inch 90° Elbow 5 feet
3 feet 10-inch 45° Elbow 2 feet
3¼ in x 10 in to 8
25 feet
in / 10 in Round Transition
Wall Cap with
Damper
4 feet
*
9
Preparation and Setup
Ductwork Tips
Wherever possible, reduce the number of transitions, turns, and sharp angles. Two staggered 45° angles are better than one sharp 90° angle.
Keep turns as far away from the hood exhaust as possible, and keep as much space between any bends as possible.
For best performance: use round duct instead of rectangu­lar, especially when elbows are required.
If multiple elbows are used, try to keep at least 24 inches of straight duct between each elbow.
Avoid using “S” or back-to-back adjacent elbows.
In extremely cold weather regions, use thermal breaks, i.e., short sections of non-metallic duct, to avoid indoor heat loss. Locate the break as close as possible to the outside pass-through point.
Do not use flexible metal duct. Do not use ductwork that is smaller than what is advised in the tables.
The hood exhaust connects to an 8-inch round duct. You can increase the duct size over the duct run if desired.
To prevent a backdraft, never decrease the duct size over the run. If existing ductwork is smaller than 8 inches in diameter, remove it and replace it with 8-inch ductwork.
Do not rely on tape alone to seal duct joints. Fasten all connections with sheet metal screws, and tape all joints with certified duct tape or foil tape.
Use sheet metal screws as needed to support the weight of the ducting.
To prevent backdrafts, a damper at the duct outlet may also be required.
10
Preparation and Setup
WARNING
• The electricity to the range hood should be installed only by a licensed electrician.
• Observe all governing codes and ordinances during site preparation and installation. Contact your local building department for further information.
• Failure to properly anchor the hood to the wall may result in personal injury due to the unit falling off the wall.
• To avoid an electric shock hazard and property dam­age, locate electric wires and water pipes and avoid drilling or cutting in the vicinity.
• Use the temporary holding brackets only to hold the hood in place until permanent anchoring is secured.

Preparing the Mounting Location

Holding brackets and hardware are provided to temporarily hold the hood in place while you permanently fasten the hood to the wall.
The illustrations below show the purpose of the holding brackets and the support behind the wall.
1. If mounting the hood to brick or masonry, select anchors capable of holding the full weight of the hood.
2. Make sure the mounting surface is properly reinforced to support the full weight of the unit.
If mounting the unit to drywall or a plastered surface, install a reinforced mounting block between the studs.
Attach screws directly to the studs and cabinets if they align with the mounting holes in the back and top of the hood.
Model Weight
RNHP3012 51 lbs. (23 kg)
RNHP3018 RNHP3612
53 lbs. (24 kg)
Holding Brackets
(Enlarged for Detail)
RNHP3618 57 lbs. (26 kg)
RNHP4812 70 lbs. (32 kg)
RNHP4818 77 lbs. (35 kg)
Stud
Support Block
Holding Brackets
Stud
Support Structures Behind the Wall
11
Installation Instructions

Marking the Centerlines

These measurements and marks are for centering and leveling the hood, marking the duct cutouts, and installing the holding brackets.
The holding brackets temporarily hold the hood while you mount it permanently into place.
Have a marking tool, tape measure, and level ready.
1. Position the hood in the same orientation as it will be when installed. (For example, if it is a top vent installa­tion, set the hood with the vents on top.)
2. Measure the distance from the edge of the hood to the center of the exhaust port.
3. Transfer that measurement to the wall (for a rear vent), or overhead (for top vent). Measure the X and Y axis to find the centerline.
4. Extend the line down 10 inches (25.4 cm).
5. Cut a hole that is 1 inch larger than the duct. Dual exhaust models require two (2) holes.
Top Exhaust
C
L
48” (121.92 cm)
RNHP48 Top and Rear Exhaust Centerline
C
L
9 7/8”
(25.08 cm)
14 1/8”
(35.88 cm)
Top Exhaust Centerline
Rear Exhaust
C
L
12
Rear Exhaust Centerline
Installation Instructions
Installing the Holding Brackets
IMPORTANT: Placing the holding brackets above, below, or off the centerline will cause alignment problems during final installation.
1. Mark the holding bracket’s horizontal centerline 2 1/8 inches (54 cm) below the top of the hood.
2. Next, mark the holding bracket’s two vertical center­lines. Refer to the table and image on right.
3. Measure and mark the “F” distance.
4. Lay the bracket against the wall, and align the screwholes with the horizontal centerline.
• Make sure the anchors and/or screws being used are
strong enough to support the hood.
• Make sure drywall installations are properly
reinforced.
5. Mark the two holes in the bracket.
6. Drill those two holes for screws or anchors.
7. Attach the brackets securely to the wall.
Holding Bracket Cenerline Distance
Models F
RNHP3012, RNHP3018 12 1/2 in (31.75 cm)
RNHP3612, RNHP3618 7 1/8 in (18.1 cm)
RNHP4812, RNHP4818 17 in (43.18 cm)
Hood
2 1/8”
Bracket location
location
C
L
F F
Bracket location
Marking the Centerlines and Brackets
Step 4
Mounting
block
C
L
location
Hood
C
L
Attaching the Brackets to the Wall
13
Installation Instructions

Rotating the Blower(s) for Rear Exhaust

WARNING
• Do not install the range hood unless the electrical service provided meets the range hood specifications.
• Observe all governing codes and ordinances during installation. Contact your local building department for further information.
• A qualified technician must complete the installation of this built-in appliance. More than one person is required to raise the hood into place. The owner is responsible to make sure the hood is properly installed.
Top Exhaust
Rear Exhaust
The blowers (also called fans) can be rotated so that the air is vented out the back of the hood.
If the hood will be installed in a top exhaust configuration, your hood is already in the default top exhaust position.
If the hood will be installed in a rear exhaust configuration, the blowers must be rotated so the exhaust vents through the rear of the hood and to the outside.
This must be done before hanging the hood.
Tools Needed
5/16” Nut driver Phillips screwdriver
AHT10 Transition Kit (optional) plus metal
Cable ties
screws and foil tape
10” Ducts and ducting materials
8” Duct and ducting materials
14
Installation Instructions
Rotating the Blower(s) for Rear Exhaust
Various models illustrate these instructions, so the images presented might not be an exact replication of the hood being installed.
However, the best illustrations were chosen to help communicate the intended information.
Instructions:
Disassembling Parts
1. Unhook and remove the grease channel.
2. Place the hood assembly on a large, flat surface.
Take special care not to scratch the hood.
3. Remove the duct collar from the top of the unit. Save the collar and screws.
Removing the Blower(s)
4. Tip the hood up, so that it lays on its back.
You are now facing inside the hood.
5. Find the end of the cable assembly plugged into the bottom left of the blower.
6. Squeeze the connector, and unplug it.
Do not pull directly on the cable assembly. Doing so will damage the contacts and wires; always pull from the connectors.
7. Unscrew the cable clamp(s) and remove the hardware that holds the blower and L-bracket.
8. Detach the blower and plate, and place them nearby.
Step 1
Back of Hood
Grease Channel
Steps 2-3
Duct Collar
Back of Hood
Steps 4-8
continued...
blower
plate
Front of Hood
L-Bracket
15
Installation Instructions
Rotating the Blower(s) for Rear Exhaust
Orientating the Blower/Vent L-Brackets
9. Unscrew and remove the L-bracket that is in the default top-venting orientation.
10. Turn and align the L-bracket so the hole is in back of the hood, allowing a rear-venting configuration.
continued...
Step 9
Top of Hood
Back of Hood
Default Orientation:
Blower/Vent L-Bracket
Step 10
Top Vent Open
Rear Vent Closed
Top of Hood
Back of Hood
16
Blower/Vent L-Bracket
Rotated Blower Orientation:
Top Vent Closed
Rear Vent Open
Installation Instructions
Rotating the Blower(s) for Rear Exhaust
Orientating the Blower(s)
It is imperative that the blower(s) are installed in the correct orientation.
To do this, make sure the bower I/O port is against the back of the hood. Confirm the placemet is correct by comparing it with the figures on the right.
11. Roll the hood on its top so the tip of the blower can
extend beyond the exit vent.
12. Insert the blower into the exit vent with this specific
placement:
When standing at the back of the hood and looking down at the blower:
• The blower I/O port must be on the right, and
• The blower I/O port must be against the back of
the hood.
Finalizing the Rear Vent Setup
Steps 11-12
Blower tip extends here
Back of Hood
Blower I/O port
13. Refasten the cable clamps and assembly to the hood.
14. Connect the cable assembly to the blower’s I/O port.
15. Attach the duct collars to the back of the hood.
16. Place the hood in a safe, upright position.
Back of Hood
Step 15
Front of Hood
Top of Hood
17
Installation Instructions

Assembling the Filters

Filters are boxed separately and must be assembled during installation. All knobs and hardware that is needed is included with the filters.
To ensure the correct orientation, make sure the top of the filter lays face-up.
The face of the filter has:
• plastic peel-away coating
• beveled lip on the inside frame
• screw holes up on the ridge (not down in the trough)
Instructions
1. Remove the plastic coating and confirm that the inside lip is beveled. If this is true, proceed. If not, flip the frame.
2. Align the screw, lock washer, and knob with the filter. Make sure the knob is on the ridge and the screw and lock washer are in the trough.
3. Twist and secure until tight.
4. Proceed with the Installation Instructions and install the filters after hanging the hood.
beveled lip
2
Parts
Filter (baffle style)
1
Knob
2
Screw M8
3
Lock washer #10
4
1
4
3
RNHP Baffle-Style Filter
18
Replacement Part Number Replacement Part Description
702579 Baffle Filter Kit (1 pc + hardware)
702580 Baffle Filter Kit (2 pc + hardware)
Installation Instructions
32”
(81.3 cm)
13 3/4”
(34.9 cm)
3/4”
(1.9 cm)
9”
(22.9 cm)
2” (5.1 cm)
Using the Dual to Single Transition Kit# AHT10
On dual exhaust models, the two 8-inch duct exhausts can be transitioned into one 10-inch duct.
Assemble the Dacor transition kit # AHT10 before hanging the hood. This transition kit fits over the top or rear ventila­tion exits.
Preparing the AHT10
1. Create a lip around the transition kit by bending the bottom edges backward at right angles to create a 3/4”
flange around the base.
Bending the Flange for:
Top Vent Configuration: None. Rear Only
Rear Vent Configuration On models 3012, 3612, 4812
Notes: 12” hood height requirement
Keep one of the long edges straight!
Leave a long edge straight and unbent.
This lip will act as a bracket.
One (1) edge remains straight and unbent.
IMPORTANT: Rear vent, 12-inch tall hood configurations, keep one of the long edges straight.
12-inch tall hoods are models: 3012, 3612, 4812
12-inch
height
18-inch
height
Bending the Flange for:
Top Vent Configuration: 3012, 3612, 4812
3018, 3618, 4818
Rear Vent Configuration
On Models: 3018, 3618, 4818
Notes: 18” hood height requirement
• If your hood model ends in “12” see above
Four (4) corners are bent backward 90 degrees.
19
Installation Instructions
Installing the AHT10
Top Vent: 3012, 3612, 4812
3018, 3618, 4818
1. Drill holes on the flanges for metal screws. Make sure the holes pierce the top of the hood (see right).
2. Center the transition kit over the duct collars.
3. Fasten the kit into place using sheet metal screws (not included).
4. Seal the base of the transition kit with foil tape or duct tape.
Rear Vent: 3018, 3618, 4818
(18-inch height requirement)
1. Drill holes for screws in the flanges. Make sure the
holes pierce the rear of the hood (see right).
2. Center the AHT10 transition kit over the duct collars.
3. Fasten the AHT10 into place using sheet metal screws
(not included).
4. Seal the base of the AHT10 with foil or duct tape.
Top Vent: 3012, 3612, 4812
3018, 3618, 4818
Rear Vent: 3018, 3618, 4818
Rear Vent: 3012, 3612, 4812
(12-inch height requirement)
1. Drill holes for screws in the flanges. Make sure the
holes pierce the top of the hood (see right).
2. Center the AHT10 transition kit over the duct collars.
3. Lay the long edge of the AHT10 over the top of the
hood.
4. Fasten the AHT10 into place using sheet metal screws
(not included).
5. Seal the base of the AHT10 with foil or duct tape.
20
Rear Vent: 3012, 3612, 4812
Long edge on top of kit is straight and unbent. It overlaps the top of the hood and works like a bracket.
Installation Instructions

Hanging the Range Hood

WARNING
Hanging the range hood requires two people. Do not attempt to lift the hood without assistance.
When hanging the hood, be careful not to scratch or dam­age the hood.
1. Remove the plastic film from the hood.
There are hanging slots in the back of the hood a few inches from the top. The holding brackets on the wall engage here and temporarily hold the hood in place.
2. Lift the hood up and catch holding brackets in the hanging slots in the back of the hood (see figure Hanging the Hood).
3. Adjust the hood into its final position.
4. Mark the spot by drawing in a mounting hole in the back of the hood (see figure Hanging and Mounting Slots ). This is where a screw will hold the hood to the wall stud or (concrete) anchor.
5. Mark the top of the hood if the configuration calls for the hood to be secured at the top.
6. Remove the hood from the wall.
7. Drill the pilot or anchor holes. If using anchors, insert them into the anchor holes.
8. Reattach the hood to the holding brackets.
9. Adjust the hood into its final position and fasten it into place:
Insert the fasteners through the mounting slots in the back and top of the hood and into the studs, mounting blocks, or anchors.
Hanging the Hood
Holding brackets
Hanging slots in the back of the hood
Mounting slots
Hanging and Mounting Slots
21
Installation Instructions

Hardwiring the Hood

WARNING
• To avoid electric shock or fire hazard, prior to connecting the electrical wiring to the hood, make sure that power to the hood power supply line is turned off at the fuse box or circuit breaker panel.
• Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in dam­age to the hood’s electrical system. See page 7 for specifications.
• Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, prop­erly grounded wire installed by a licensed electrician.
• Make sure all wire used is capable of handling the total connected load. See page 3.
1. Shut power OFF at the circuit breaker or fuse box.
2. Feed the cable assembly through the hood.
3. Connect the cable assembly to the blower.
4. Connect the hood wiring to an electrical junction box on a dedicated circuit. See Wire Diagrams.
To Junction
Box
Control Panel Wire Diagram
Neutral (white)
Ground (green)
Hot (black)
Power
Terminals
inside Hood
Not used N1
Gnd
L1
To house circuit breaker
or fuse box
Wire nut,
3 places
GREEN GREEN
UL/CSA approved
NEMA strain relief
Junction Box Wire Diagram
Junction box
WHITE WHITE
BLACK BLACK
To Range Hood
22
Installation Instructions
WARNING
• Do not ground the circuit to a gas line.
• Do not ground the circuit to a hot water pipe.
• Water lines that are insulated must be jumped to assure continuity to ground. See below.
To house circuit breaker
panel or fuse box
Wire nut,
3 places
GREEN GREEN
UL/CSA approved
NEMA strain relief
WHITE WHITE
BLACK BLACK
To Range Hood
Grounding by External Cold Water Pipe
Separate No. 10 (minimum)
copper ground wire
Fasten clamp tightly
on metal pipe
Junction box
Meter
No. 4 copper
wire
Clamps
Bare metal
Insulated Pipe Jumper
(if necessary)
Inserting Light Bulbs
Make sure dimmable bulbs are used. The electronic board was designed for dimmable lights and using non-dimmable types will cause damage and faulty performance.
Shut the main circuit breaker OFF while inserting new or while changing bulbs. If an electrical short occurs while the
main power circuit is ON, significant damage can occur.
Follow the diagram to the right for instructions.
1. Attach the suction cup to the lens of a dimmable light bulb. (Both are supplied parts.)
Make sure the bulb faces are clean so the suction cup can stick.
2. Insert the bulb into one of the light fixtures.
3. Screw it into place and remove the suction cup.
4. Repeat for the remaining light fixtures.
5. Switch the main circuit power ON.
Replacement Part Number Replacement Part Description
702666 Dimmable LED Bulb Replacement Kit (1 bulb + 1 suction cup tool)
3
2
1
Inserting Light Bulbs with the Suction Cup Tool
23
Verifying the Setup
Installation Instructions
FAN
button
LIGHTS
button
TIMER
button
Feature Button Panel
1. Make sure the main power switch is OFF. (Refer to the figures at right.)
2. Turn power ON at the circuit panel or fuse box.
3. Then turn the main power switch ON. The control panel will flash several times during startup.
4. Insert the filters gently:
Be careful not to scratch the back of the grease channel!
Raise the front edge into the clip, and press forward.
Lift the rear edge up and above the grease channel.
Use care not to scratch the grease channel or other parts of the hood or filters.
Set the rear edge onto the grease channel.
5. Press the LIGHTS button. Verify that all the lights illuminate.
6. Press the LIGHTS button again to turn the lights to the low setting.
7. Press the LIGHTS button again to turn the lights off.
8. Press the FA N button once and release. Verify that one light is showing on the fan speed indicator and that the fan is on at low speed.
9. Slowly touch and release the FA N button three times. Verify that with each touch, the number of lights rises and that the fan speed increases.
10. Press the FAN button again to turn the fan OFF
Grease channel
Detail of main power switch
OFF
ON
Main Power Switch
FRONT
Feature button pamel
Light
Filter
Detail of front filter clip
FRONT
If the Hood Fails to Function Correctly:
1. Verify that power is supplied to the hood.
2. Remove the right filter, find main power switch behind the front panel, and confirm the main power switch is ON.
3. Check the electrical connections to ensure that the installation has been completed correctly.
4. Repeat the above steps.
If the hood still does not work, contact Dacor Distinctive Service at (800) 793-0093 ex. 2822. Do not attempt to repair the appliance yourself. Do not attempt to repair the appliance yourself. Dacor is not responsible for ser­vice required to correct a faulty installation.
24
REAR
FRONT
Location of
Main Power Switch
Installation Instructions
The Installation Checklist
WARNING
• To ensure a safe and correct installation, the follow-
ing checklist should be completed by the installer to ensure that no part of the installation has been over­looked.
• Proper installation is the responsibility of the home-
owner. The importance of proper installation of your Dacor range hood cannot be overemphasized.
□ Is the hood properly attached to the wall according to
the instructions on page 13 and 21?
□ Is the ductwork completely installed? Are all joints
attached with sheet metal screws and wrapped with foil tape? See page 19.
□ Is the range hood wired and grounded according to
these instructions and in accordance with all applicable electric codes? See page 7 and 22.
□ Are the filters properly assembled according to page
18?
□ Has setup been verified? □ Have any problems been noted on the warranty card
or during the on-line warranty activation? Has the war­ranty been activated on-line or the warranty card filled out completely and mailed?
25
Wiring Diagrams
NOCOM
COIL
B
BL
W
R
YYW W
POWER
SWITCH
CONNECT TO 120V, 60Hz, 15A SINGLE PHASE POWER SUPPLY
B
B
B
B
G
W
W G
CHASSIS GROUND
BLOWER
455W, 115V
Y
B
W
R
O
B
BLWW
MICROPROCESSOR PROGRAMMING HEADER
P3
2 4 6 8 10
1 3 5 7 9
HOOD POWER
and
CONTROL BOARD
K4 K3 K2
K1
11 10 9 8 7 6 5 4 3 2 1
P2
P1
10 9 8 7 6 5 4 3 2 1
HOOD
LIGHT 75W
HOOD
LIGHT 75W
"CLEAN FILTER"
LED
INDICATOR
RESISTOR
620
1/4W
2
3
4
FAN
SPEED
LED
INDICATOR
RESISTOR
3.6K
,
1/4W
3 4
FAN
SW
43 43
LIGHT
SW
TIMER
SW
CAUTION:DISCONNECT POWER SUPPLY AT THE
FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
WIRING DIAGRAM:
RNHP 3012, 3018
RESISTOR
3.6K 1/4W
RESISTOR
3.6K
1/4W
RESISTOR
3.6K
1/4W
RELAY
BR
W
W W
WWW
W
W
W
R
RESISTOR
3.6K
1/4W
1
,
,
,
,
,
WIRE COLOR CODE
W -WHITE
B -BLACK Y -YELLOW O -ORANGE R -RED BL -BLUE BR -BROWN
G -GREEN
V -VIOLET

RNHP3012, RNHP3018

Wiring Diagram: 1-Blower, 2-Light Models
26
Wiring Diagrams
RNHP3612, RNHP3618
WIRING DIAGRAM:
RNHP 3612,
3618
B
BLOWER
455W, 115V
RESISTOR
,
620 1/4W
COIL
HOOD
LIGHT 75W
Y
W W
HOOD
LIGHT 75W
Y
HOOD
LIGHT 75W
Y
W
WIRE COLOR CODE
W -WHITE
B -BLACK Y -YELLOW O -ORANGE R -RED BL -BLUE BR -BROWN
G -GREEN
V -VIOLET
O
B
R
W
B
R
W
MICROPROCESSOR PROGRAMMING HEADER
NOCOM
RELAY
Y
10 9 8 7 6 5 4 3 2 1
K4 K3 K2
2 4 6 8 10
1 3 5 7 9
BLWW
CONTROL BOARD
P3
11 10 9 8 7 6 5 4 3 2 1
BR
P2
K1
HOOD POWER
and
WWW
W
W
W
W W
W
B
POWER SWITCH
B
CHASSIS GROUND
G
W
W G
B
B
P1
R
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
3 4
FAN
SW
FAN
SPEED
LED
INDICATOR
4
3
2
1
CAUTION:DISCONNECT POWER SUPPLY AT THE
FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
Wiring Diagram: 1-Blower, 3-Light Models
LIGHT
SW
43 43
TIMER
SW
RESISTOR
3.6K
,
1/4W
"CLEAN FILTER"
LED
INDICATOR
CONNECT TO 120V, 60Hz, 15A SINGLE PHASE POWER SUPPLY
27
Wiring Diagrams
RNHP4812, RNHP4818
WIRING DIAGRAM:
RNHP
4812 & 4818
BBLO
R
W
BLOWER
455W, 115V
BLOWER
455W, 115V
RESISTOR
,
620 1/4W
HOOD
LIGHT 75W
Y
W W
HOOD
LIGHT 75W
Y
HOOD
LIGHT 75W
Y
W
HOOD
LIGHT 75W
Y W
WIRE COLOR CODE
W -WHITE
B -BLACK
Y -YELLOW O -ORANGE R -RED
BL -BLUE BR -BROWN
G -GREEN
P1
W
R
V -VIOLET
G
W
W G
B
POWER
SWITCH
B
CHASSIS GROUND
B
B
BL
O
B
R
W
O
R
COIL
NOCOM
W
RELAY
K4 K3 K2
MICROPROCESSOR PROGRAMMING HEADER
2 4 6 8 10
1 3 5 7 9
O
B
R
W
B
Y
10 9 8 7 6 5 4 3 2 1
BLWW
CONTROL BOARD
P3
11 10 9 8 7 6 5 4 3 2 1
BR
K1
HOOD POWER
W W
W
P2
and
WWW
W
W
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
RESISTOR
,
3.6K
1/4W
3 4
FAN
SW
FAN
SPEED
LED
INDICATOR
4
3
2
1
CAUTION:DISCONNECT POWER SUPPLY AT THE
FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
Wiring Diagram: 2-Blower, 4-Light Models
LIGHT
SW
43 43
TIMER
SW
RESISTOR
3.6K
,
1/4W
"CLEAN FILTER"
LED
INDICATOR
CONNECT TO
120V, 60Hz, 15A
SINGLE PHASE POWER SUPPLY
28
Notes
29
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com
Loading...