RNF241WCL, RNF241WCR,
Document # PG11-014
RNF242WCL, RNF242WCR
Renaissance® 24” Wide Wine Cellars
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
Operating Temperature Requirements
Room Temperature requirements
for proper operation
60°F to 90°F (16°C to 32°C)
Power Supply Requirements
■ This appliance should have its own separate, 110-120 Vac, 15 Amp.
grounded circuit controlled by a circuit breaker or fuse.
■ Do not connect to a circuit that is turned on and off by a switch.
■ Follow the National Electrical Code and local codes and ordinances
when installing the electrical outlet. The electrical outlet must be
installed by a licensed electrician.
■ The electrical outlet must accept a grounded three prong power cord.
A ground fault circuit interrupter (GFCI) type is not recommended
because it may cause interruption of operation. See Location
Requirements for guidelines.
Total Connected Load Circuit Required
1.0 Amp.
@ 115 Vac, 60 Hz.
3-Wire, Grounded, Dedicated
Circuit 115 Vac @ 15 Amp. 60 Hz.
Revised 07/17/14 Page 1/1
PLANNING
GUIDE
24” min.
(61.0 cm)
67” max. (170 cm)
47” max. (120 cm)
34 1/4” min.*
CABINET CUTOUT AND PRODUCT DIMENSIONS
24” min.
(61.0 cm)
(87.0 cm)
23 1/2”
34 - 36 1/2”
(86.4 - 92.8 cm)
3 7/8 - 6 3/8”
20 3/4”
(52.7 cm)
(59.5 cm)
(9.8 - 16.2 cm)
2 7/8”
(7.3 cm)
1 5/8”
(4.1 cm)
Location Requirements
■ Operate the appliance only on a solid, stable and level surface. Do
not operate on top of carpeting, or other soft surface.
■ Locate the wine cellar in a convenient location, away from extreme
heat and cold. Locate it away from direct sunlight. It should not
be located next to ovens, grills or other sources of high heat. It is
suggested that it be located in the coolest area of the room.
■ Place your appliance on a floor that is strong enough to support it
when it is fully loaded. It weighs 100 lbs (45 kG) unloaded.
■ To ensure proper ventilation, the front of the unit must be completely
unobstructed. Choose a well ventilated area with temperatures
between those stated above. This unit must be installed in an area
protected from the elements, such as wind, rain, water spray or drips.
■ Optimal spacing for ventilation around the appliance (for maximum
efficiency) is 5 inches (12.7cm) in back, at the sides and above. The
Dacor wine cellar may be recessed in an opening between cabinets
or installed at the end of a cabinet run using a side panel to enclose
it. When installing in an enclosed space, the absolute minimum space
is 1/4” (5.0 mm) of space on both sides, 1/4” (5.0 mm) of space at the
top and 2 1/4” (5.7 cm) in back. See diagram, right.
■ The overall height of the appliance can be increased by 2 1/2” (6.4
cm) by adjusting the feet.
■ The electrical outlet must be accessible after installation so that the
user can unplug the appliance.
■ It is advisable to install the appliance with sufficient ventilation in a dry
and/or an air-conditioned place to avoid condensation build up on the
door during period of high humidity.
All specications subject to change without notice.