MANUAL
CONGRATULATIONS
Congratulations on purchasing your new CTEK professional 24V DC/DC switch mode battery
charger, 12V converter and battery equalizer. This charger is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest technology in battery charging with
charging and analysis in 4 steps with temperature compensation.
Read this User Manual and follow the instructions carefully before using your new charger.
SAFETY
• The charger is designed for 24V lead-acid batteries mounted into vehicles.
Do not use the charger for any other purpose
• Use safety glasses when connecting or disconnecting a battery.
• Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin
or eyes. Seek medical advice.
• Make sure that the cables are not being pinched or in contact with warm surfaces
or sharp edges.
• While charging, a battery can emit explosive gases, avoid sparks in the immediate area.
• Always provide for proper ventilation during charging.
• Avoid covering the charger.
D250TS
The D250TS has one 24V input and two alternating outputs. One output charge a 24V
battery and the other provides 50% of the input voltage to the midpoint of a 24V system. This
enables connection of 12V consumers to the battery string and also equalizing this battery
string, for longer battery life.
D250TS
FEATURES:
• Multi-step10A temperature compensated battery charging and battery maintenance.
• Battery separation of Starter and Service batteries.
• Equalization of Service batteries
• Makes connection of 12V consumers directly to 24V Service battery possible.
• When the charger is correctly connected the charger will output 24V on the status signal wire.
Connection of a 24V lamp (max 2W) to the status signal wire will indicate a correctly connected charger.
• The charger will maintain the starter battery untill the supply is below 14V. To avoid draining the
service battery always connect a charger to the service battery when the vehicle is not used for
a longer period.
Service ground
+IN +OUT
Service Battery
24V+
Service Battery Midpoint
D250TS
Starter Battery
24V+
Status signal wire
EQU
Temperature sensor
EN
EN • 3
20015884C D250TS, Manual, Print file 002.indd 3 2011-12-20 13:27:12
INSTALLATION OF UNIT
1. Attach the temperature sensor holder on a flat surface on one Starter battery. Position it as close
as possible to a positive post.
2. Use the included drill template. Wiring is simplified if the units are installed according to the drill
template, but other setups are possible.
3. Install the unit(s) on a flat surface where it can be properly fixed and where the unit is not
exposed to fuels, oils or splashes of dirt.
4. Mount the unit with screws intended for the surface and attach it with one screw in each of the
four holes in the corners of the unit. See picture 1. Mount the unit with M4 or ST4.2 screws. The
required torque depends on the surface for mounting.
DRILL TEMPLATE
Ø 5mm
168
mm
Figure 1
Service ground
mm
90,6
Service Battery Midpoint
Status signal wire
Service Battery
24V+
Starter Battery
24V+
2Nm
Temp sensor