CTEK MXS 3.6 User Manual

0 (0)
CTEK MXS 3.6 User Manual

MANUAL

CONGRATULATIONS

to the purchase of your new professional switch mode battery charger.

This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging.

SUPPLY PLUG*

MAINS CABLE

CTEK COMFORT CONNECT

CHARGE CABLE

MXS 3.6

 

MODE

 

12V/3.6A

CTEK COMFORT CONNECT – clamp

CTEK COMFORT CONNECT – eyelet M6

* Supply plugs may differ to suit your wall socket.

20015449F Manual MXS 3.6, EU. Print file 006.indd 3

CHARGING

1. Connect the charger to the battery.

2.

Connect the charger to the wall socket. The Standby lamp will indicate that the mains

 

 

cable is connected to the wall socket. The error lamp will indicate if the battery clamps

 

 

are incorrectly connected. The reverse polarity protection will ensure that the battery

EN

 

or charger will not be damaged.

 

 

 

 

3.

Press the MODE-button to select charging program.

 

4. Follow the indication lamps through the charging process.

 

 

The battery is fully charged when

is lit.

 

5.

Stop charging at any time by disconnecting the mains cable from the wall socket or by

 

 

setting the charger on Standby.

 

 

DESULPHATION

FULLY CHARGED

BULK

ABSORPTION

PULSE , MAINTENANCE CHARGING

ERROR LAMP

MODE-

BUTTON MODE

 

 

 

 

 

 

STANDBY

SMALL

NORMAL

COLD

 

BATTERY

BATTERY

WEATHER

 

PROGRAM

PROGRAM

PROGRAM

EN • 3

2011-10-10 16:36:19

CHARGING PROGRAMS

Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program.

The table explains the different Charging Programs:

Program

Battery

Explanation

Temp range

Size (Ah)

 

 

 

 

 

7–14Ah

Small battery program

-20°C–+50°C

 

14.4V/0.8A

(-4ºF–122ºF)

 

 

Use for smaller batteries.

 

 

 

 

 

 

 

Normal battery program

+5°C–+50°C

 

14–120Ah

14.4V/3.6A

(41ºF–122ºF)

 

Use for WET batteries, Ca/Ca,

 

 

 

MF, GEL batteries and many

 

 

 

AGM batteries.

 

 

 

 

 

 

 

Cold weather program

-20°C–+5°C

 

 

14.7V/3.6A

(-4ºF–41ºF)

 

14–120Ah

Use for charging at low tempera-

 

 

 

tures and for power AGM batter-

 

 

 

ies like Optima and Odyssey.

 

 

 

 

 

ERROR LAMP

If the error lamp is lit, check the following:

Is the chargers positive lead connected to the batterys positive pole?

Connect the charger according to page 5.

READY TO USE

The table shows the estimated time for empty battery to 80% charge

BATTERY SIZE (Ah)

TIME TO 80% CHARGED

7Ah

7h

20Ah

5h

60Ah

13h

75Ah

17h

4 • EN

CHARGING PROGRAM

DESULPHATION

BULK

ABSORPTION

PULSE

VOLTAGE (V)

 

 

 

1

2

3

4

CURRENT (A)

 

 

 

14.4V

Increasing voltage

14.4V

12.9V‒14.4V

 

to 14.4V

Declining current

0.8‒0.4A

 

0.8A

 

 

14.4V

Increasing voltage

14.4V

12.9V‒14.4V

 

to 14.4V

Declining current

3.6A

 

3.6A

 

 

14.7V

Increasing voltage

14.7V

12.9V‒14.7V

 

to 14.7V

Declining current

3.6A

 

3.6A

 

 

Charge cycle restarts if voltage drops

STEP 1 DESULPHATION

Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead plates of the battery restoring the battery capacity.

STEP 2 BULK

Charging with maximum current until approximately 80% battery capacity.

STEP 3 ABSORPTION

Charging with declining current to maximize up to 100% battery capacity.

STEP 4 PULSE

Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and gives a pulse when necessary to keep the battery fully charged.

20015449F Manual MXS 3.6, EU. Print file 006.indd 4

2011-10-10 16:36:20

Loading...